BLUETTI AC70P Portable Power Station User Manual
- June 15, 2024
- Bluetti
Table of Contents
BLUETTI AC70P Portable Power Station
Warning
- Charge the unit before first use.
- Do not use solar panels with open circuit voltage higher than 58V. Solar input voltage range for the unit is 12V-58VDC.
- Charge the unit immediately when the SoC drops below 5%. If the SoC drops to 0, power off the unit and charge it for at least 30 minutes before restarting.
- The unit is for off-grid use only. Do not connect its AC output to the grid.
- If not used for more than 3 months, charge the unit to 40%-60% SoC and store it with the power off. For optimum battery life, discharge and charge the unit every 3 months.
Safety Instructions
Read this manual for instructions on the proper use and safety information for the product. The safety instructions provided herein are for illustrative purposes that include but are not limited to those listed in this manual. Actual operation shall comply with all applicable safety standards. If you have any questions, feel free to contact BLUETTI support or your local BLUETTI dealers.
Statement
To ensure a safe operation, it’s crucial to observe and adhere to the following conditions:
- Always operate or store the product in the conditions specified in this manual.
- Avoid unauthorized disassembly, component replacement, or modification of software codes.
BLUETTI shall not be liable for damages resulting from the following circumstances:
- Force majeure events such as earthquakes, fires, storms, floods, or mudslides.
- Damage caused by the customer’s own transportation.
- Damage resulting from inadequate storage conditions as specified in the manual.
- Damage caused by customer negligence, improper operation, or intentional actions.
- System or hardware damage caused by third parties or customers, including but not limited to improper handling and installation not in accordance with the instructions in this manual.
- Usage of the product with devices that require a high-performance Uninterruptible
Power Supply (UPS), including but not limited to data servers, workstations, medical equipment, and other similar devices.
General Requirements
INSTRUCTIONS PERTAINING TO RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS IMPORTANT SAFETY INSTRUCTIONS
WARNING – When using this product, basic precautions should always be
followed, including the following:
a. Read all the instructions before using the product.
b. To reduce the risk of injury, close supervision is necessary when the
product is used near children.
c. Do not put fingers or hands into the product. And do not insert
foreign objects into any ports of the product.
d. Use of an attachment not recommended or sold by the manufacturer may
result in a risk of fire, electric shock, or injury to persons.
e. To reduce the risk of damage to the electric plug and cord, pull the
plug rather than the cord when disconnecting the product.
f. Do not use a battery pack or appliance that is damaged or modified, as
they may exhibit unpredictable behavior resulting in fire, explosion, or
personal injury.
g. Do not operate the product with a damaged cord or plug, or a damaged
output cable.
h. DO NOT attempt to replace the internal battery or any other component
of the product by anyone other than authorized personnel. There are no end-
user serviceable components. Do not disassemble the product, take it to a
qualified service person when service or repair is required. Incorrect
reassembly may result in a risk of fire or electric shock.
i. To reduce the risk of electric shock, unplug the product from the
outlet before attempting any instructed servicing.
j. WARNING – RISK OF EXPLOSIVE GASES. To reduce the risk of battery
explosion, follow these instructions and those published by the battery
manufacturer and manufacturer of any equipment you intend to use in the
vicinity of the battery. Review cautionary markings on these products and
engines.
k. PERSONAL PRECAUTIONS
1) Wear complete eye protection and clothing protection. Avoid touching
eyes while working near the battery.
2) NEVER smoke or allow a spark or flame in the vicinity of the battery
or engine.
3) Be extra cautious to reduce the risk of dropping a metal tool onto the
battery. It might spark or short-circuit the battery or other electrical parts
which may cause an explosion.
l. When charging the internal battery, work in a well ventilated area and
do not restrict ventilation in any way.
m. Under abusive conditions, liquid may be ejected from the battery;
avoid contact. If contact accidentally occurs, flush with water. If liquid
contacts eyes, additionally seek medical help. Liquid ejected from the battery
may cause irritation or burns.
n. Do not expose the product to fire or excessive temperature. Exposure
to fire or temperature above 130°C may cause an explosion.
o. Have servicing performed by a qualified repair person using only
identical replacement parts. This will ensure that safety is maintained.
p. DO NOT operate in wet conditions. If the product becomes wet, please
thoroughly dry it before using.
q. Please ensure proper ventilation while in use and do not obstruct fan
openings.
Inadequate ventilation may cause permanent damage to the product.
r. DO NOT stack anything on top of the product while in storage or use.
DO NOT move
the product while operating as vibrations and sudden impacts may lead to poor
connections to the hardware inside.
s. In case of fire, use only a dry powder fire extinguisher appropriate
for the product.
t. WARNING – RISK OF ELECTRIC SHOCK. Never use the product to supply
power tools to cut or access live parts or live wirings, or materials that may
contain live parts or live wirings inside, such as building walls, etc.
u. To avoid contact with any liquids, do not use this product in the rain
or high humidity.
Grounding Instructions
This product must be grounded. If it should malfunction or break down,
grounding provides a path of least resistance for electric current to reduce
the risk of electric shock.
This product is equipped with a cord having an equipment-grounding conductor
and a grounding plug. The plug must be plugged into an outlet that is properly
installed and grounded in accordance with all local codes and ordinances.
WARNING
Improper connection of the equipment-grounding conductor can result in a risk of electric shock. Check with a qualified electrician if you are in doubt as to whether the product is properly grounded. Do not modify the plug provided with the product – if it does not fit the outlet, have a proper outlet installed by a qualified electrician.
Storage Instructions
a. When the SoC drops to 5%, please charge the product immediately.
b. Before storing the product, charge it to 40% to 60% SoC to keep it in
optimal condition.
In addition, power off the unit and disconnect all electrical connections from
it.
c. Store the product in a cool and dry place, keeping it away from
flammable or combustible materials and gases.
d. The product can be safely stored within a temperature range of -20˫ to
40˫ (-4˭ to 104˭). However, if the storage duration exceeds one month, it’s
recommended to maintain an ideal storage temperature of around 30℃ (86˭).
e. Fully cycle the product every 3 months to maintain the battery’s
health.
It’s NOT
recommended to store the unit for extended periods of time, as it may affect
its performance and overall lifespan.
If the SoC drops to 0 (during storage or upon startup), take the following actions to safely restart the product:
- Shut down immediately.
- Charge within 48 hours.
- Keep it at an ambient temperature of 5˫ to 35˫ (41˭ to 95˭) for 24 hours before charging. It’s recommended to charge the product via an AC source. If charging via solar energy, ensure that your solar system provides an output of more than 100W.
BLUETTI shall not be liable for any equipment damage caused by the violation of the above instructions
SAVE THESE INSTRUCTIONS
The symbol displayed is intended to remind you to read the instructions in the literature accompanying the product before operation and maintenance.
- Connect the product to a socket-outlet that has an earthing connection using the power cord provided.
- The socket-outlet should be installed near the product and easily accessible for safety purposes.
- NEVER dispose of a battery by throwing it into fire or a hot oven, or by mechanically crushing or cutting it, as these may cause it to explode.
- Avoid leaving batteries in extremely high-temperature environments, as this can result in an explosion or the leakage of flammable liquid or gas.
- The battery subjected to extremely low air pressure may result in an explosion or the leakage of flammable liquid or gas.
- Attention should be drawn to the environmental aspects of battery disposal.
- Please refer to the information on the exterior bottom enclosure for electrical and safety information before installing or operating the apparatus.
Packing List
Standard Packaging
Item
|
Picture
|
Qty
---|---|---
Portable Power Station
| |
1
AC Charging Cable
| |
1
Car Charging Cable
| |
1
Solar Charging Cable
| |
1
Grounding Screw (M5×10)
| |
1
User Manual
| |
1
Warranty Card
| |
1
Optional Accessories
(Available on official BLUETTI website)
Item
|
Picture
---|---
USB-C to USB-C Cable (Output)|
Cigarette Lighter to DC5521 Cable (For 12V devices with DC5521 port, such as
routers, cameras, etc.)|
Lead-acid Battery Charger (Charge a 12V/10A lead-acid battery via AC70P. For
gasoline vehicle batteries only.)|
Lead-acid Battery Charging Cable Kit (Charge the AC70P via a lead-acid
battery.)|
Battery Connection Cable Kit (Charge the AC70P via an expansion battery in
Power Bank mode.)|
Product Overview
Meet the AC70P portable power station – the ultimate companion for your travel
and adventure needs. With a 1000W pure sine wave inverter and 864Wh LiFePO4
battery, it offers ample power for all your outing gadgets like phones,
laptops, car refrigerators, and air conditioners. When you require even more
power, it boasts the innovative Power Lifting mode to tackle higher resistive
demands of up to 2000W, perfect for hairdryers, kettles, and other heating
appliances. Thanks to Turbo Charging technology, you can enjoy the convenience
of an 80% charge in just 45 minutes, and a full charge in 1.5 hours.
Whether you’re embarking on outdoor adventures, road trips, or camping trips
with friends, the AC70P is built to accompany you every step of the way. So,
go ahead and embrace your travel plans with confidence, knowing that the AC70P
will provide reliable power whenever you need it.
- DC Input
- DC Power Button
- LCD Screen
- Power Button
- Wireless Charging Pad
- AC Power Button
- AC Output
- Grounding Pole
- AC Input
- USB-A Port
- USB-C Port
- Cigarette Lighter Port
Power ON/OFF
- Power ON: Press and hold the for about 2 seconds to turn AC70P on. When the AC70P is on, press the again to turn on / off the LCD screen.
- Power OFF: Press and hold the for 2 seconds to turn off the unit.
- AC ON / OFF: When the AC70P is on, press the AC power button to turn it on / off.
- DC ON / OFF: When the AC70P is on, press the DC power button to turn it on / off
LCD Screen
- ECO Mode
- Turbo Charging
- Battery Capacity (SoC)
- Silent Charging
- DC Input
- Bluetooth Connection
- Fan
- AC Input Power
- AC Output Power
- Grid Connection
- DC Output
- AC Output
- Power Lifting Mode
- Charge / Discharge Remaining Time
- Charge / Discharge Status
- Low Temperature Alert
- High Temperature Alert
- Overload Alert
- Overcurrent Alert
- Fault Alert
- DC Output Power
- Low Voltage Alert
- DC Input Power
LCD Instructions
Startup| LCD lights up
Shutdown| LCD lights off
ECO Mode enabled| displays
Turbo Charging enabled| displays
State of Charge|
Silent Charging enabled| displays
DC input| displays
DC input| displays
Fan on or abnormal| displays or flashes
AC input power|
AC output power|
AC input| displays
DC output enabled| displays
AC output enabled| displays
Power Lifting Mode enabled| displays
Remaining charge / discharge time (hour)| displays
Charging or discharging| displays
Abnormal temperature| displays
Connected device(s) overheating| displays
Overload| displays
Overcurrent| displays
Error code report| displays
DC output power|
Battery low (below 5%)| displays
DC input power| displays
Charging
AC70P supports four charging methods: AC, solar, car, and generator.
AC Charging
Plug the AC70P into a standard wall outlet and start charging. Once it’s fully charged, the AC70P automatically stops charging to prevent overcharging. For a fast charge, you can enable Turbo Charging in the BLUETTI App, which allows for an 80% capacity in just 45 minutes at an ambient temperature of 25°C)(77°F)
Solar Charging
Connect the solar panels (in series or parallel) to AC70P via the solar
charging cable.
When receiving a continuous input of 500W, the AC70P will automatically stop
charging within 2 hours. However, please be aware that the charging time may
vary based on weather conditions, sunlight intensity, panel orientation, and
other variables.
Note: Make sure your solar panels meet the following requirements:
Voc: 12V-58V Current: 10A Max. Power: 500W Max.
Car Charging
Connect the AC70P to the vehicle’s 12V / 24V cigarette lighter port via the
car charging cable.
The AC70P also automatically stops charging when it’s fully charged. On
average, it takes about 7-9 hours to refill the AC70P using a 12V port and 4-5
hours with a 24V port at an ambient temperature of 25 °C(77°F).
Note: Make sure your vehicle meets the following conditions for charging:
- The vehicle is capable of supplying power.
- The vehicle’s engine is running during the charging process.
Generator Charging
Connect the AC70P to a generator via the AC charging cable. Under optimal
conditions, it takes approximately 2 hours to reach a full charge at an
ambient temperature of 25 °C(77°F).
Note: Make sure your generator meets the following conditions for
charging:
- The generator boasts a stable power output that exceeds the charging requirement of the AC70P.
- The generator delivers a pure sine wave AC output with voltage and frequency that meet AC70P’s specifications.
For stable and efficient charging, avoid using unreliable power sources like
wind turbines. Also, it’s not recommended to run your devices with AC70P while
it’s charging
with a generator.
Discharging
AC Discharging
Item
|
Specifications
|
Compatible Loads
---|---|---
2 × AC Outlet| 120V 50Hz / 60Hz| Appliances up to 1000W power.
e.g., air conditioners, refrigerators
Note: Do not apply AC70P to loads higher than 1000W, as this may cause damage to AC70P and yourdevices.
DC Discharging
Item
|
Specifications
|
Compatible Loads
---|---|---
Cigarette Lighter Por| 12V / 10A| 12V DC appliances up to 120W power. e.g.,
car refrigerator, air conditioner
2 × USB-A Port| 5V / 2.4A| Mobile phones and other small loads
2 × USB-C Port| 5 / 9 / 12 / 15 / 20V, 3A; 20V, 5A| Mobile phones, laptops,
etc.
Note: To ensure optimal performance, avoid short-circuiting the ports and keep them dry during use or storage. Additionally, do not block or cover the ports while ensuring proper ventilation.
Settings
The AC70P offers the convenience of adjusting its settings either via physical buttons or BLUETTI App. With the buttons located on the device itself, you have direct control over various settings such as ECO Mode, output frequency, charging modes, and other functionalities. Additionally, by using the BLUETTI App, you can access a user-friendly interface on your phone to conveniently monitor and control the AC70P.
Setting Mode
When the AC70 is powered on, press and hold the AC and DC power buttons for
about 2 seconds till the frequency indicator flashes to enter Setting Mode.
Press and hold the AC and DC power buttons at the same time to exit Setting
Mode.
Note: If you do not perform any operation in 1 minute, the AC70P will
automatically exit Setting Mode and no changes will be saved.
ECO Mode
ECO Mode is a power-saving mode that is enabled by default. When operating on
ECO Mode, the AC / DC output will automatically turn off if the AC70P is
bearing low (less than 40W or the set power) or no load for a while.
Note: When connecting a small power device, disable the ECO Mode for a
successful and uninterrupted charge experience.
In the Setting Mode, use the DC power button to navigate until the ECO icon
starts flashing on the screen. Then, press the AC power button to enable or
disable the mode.
Frequency Switching
The current output frequency (50Hz / 60Hz) is displayed in the lower right
corner of the screen. To change the frequency, access the Setting Mode, press
the DC power button and the frequency starts flashing. Then, press the AC
power button to switch between the available frequency options.
Power Lifting Mode
Power Lifting Mode allows AC70P to handle high-power resistive loads up to
2000W, which is disabled by default. In the Setting Mode, use the DC power
button to navigate until the icon starts flashing on the screen. Then, press
the AC power button to enable or disable the mode.
This mode is particularly useful when using the AC70P with demanding heating
devices such as kettles, electric blankets, and hairdryers. If the screen
reads “OVERLOAD” while operating such devices, activating Power Lifting mode
allows the AC70P to tackle these tasks effectively.
Note: The resistive loads should have a power rating between 1000W and
2000W.
Although the AC70P can handle higher power demands, its actual operating power
remains at 1000W.
Bluetooth On/Off
In the Setting Mode, use the DC power button to navigate until the icon starts
flashing on the screen. Then, press the AC power button to turn the Bluetooth
on or off.
AC Charging Mode
The AC70 supports three AC charging modes – Standard, Turbo, and Silent to fit
your specific needs. In the Setting Mode, use the DC power button to navigate
until the or icon starts flashing on the screen. Then, press the AC power
button to enable or disable these two modes.
AC Charging Instructions
Icon
|
Mode
|
Recharging Time
|
Note
---|---|---|---
None
|
Standard
|
2 hours
|
Reduces battery wear and tear
for long battery life.
|
Turbo
|
1.5 hours
0-80% in 45 mins
|
Convenient when recharging
time is a priority
|
Silent
|
4 hours
|
Offers a quiet, low-power operation.
BLUETTI App
Scan the QR code below or search “BLUETTI” in the App Store or Google Play to download the BLUETTI App.
For more details, please refer to BLUETTI APP INSTRUCTIONS.
Specifications
Model
|
AC70P
---|---
Country / Region
|
JP
|
US
|
CN
| EU / UK / AU
Battery Capacity
|
864Wh
Cell Type
|
LiFePO4
AC + DC Input
|
1000W Max.
Net Weight
|
10.2kg / 22.5lbs
Dimensions (LWH)
|
314mm × 209.5mm × 255.8mm / 12.4in × 8.2in × 10.1in
Charging Temperature
|
0°C-40°C / 32°F-104°F
Discharging Temperature
|
-20°C-40°C / -4°F-104°F
---|---
Storage Temperature
|
-20°C-40°C /-4°F-104°F
Working Humidity
|
10%-90%
Country/ Region
|
jp
|
US
|
CN
|
EU/UK/AU
---|---|---|---|---
AC Output
Power
|
10:0W in total
Voltage
|
100VAC
|
120VAC
|
22C/VAC
|
230VAC
Current
|
no,
|
83A
|
45A
|
4.3A
Frequency
|
SOHz /60Hz
CC Outrat
ci g a rette Lighter Port
|
12VDC /10A
USB-A ‘2
|
SVDC / 2.4A each port
USB-C –2
|
S/9/12 /15/ 20VDC. 3A; 20VDC. SA each port
Wireless Charging
|
SVV/7.SW/10W/1SW
AC Input
Voltage
|
100VAC
|
12 0VAC
|
122WAC
|
23 C/V AC
Max Current
|
9A
|
9A
|
6A
|
6A
Frequency
|
50Hz 60Hz
UPS
|
Switching time s20ms
Power
|
BSOW Max. (0%-80% in 45 minutes gtoot-4ot/sooF-Icwn
DC Input
interface
|
XTEOPM-M
Power
|
500W Max
Current
|
10A Max
Voltage
|
12V-S8VDC
Bluetooth S.0
Aax Transmission Frequency
|
lZkbps
Max RF Transmission Power
|
+12dBm
Receiver Sensitivity
|
-99:18m/1Mbps
Wireless Charging
Transmission Frequency Range
|
1105k-20SkHz
Max RF Transgression Power
|
15W
---|---
Troubleshooting
In the Setting Mode, press and hold the DC power button until an error code appears on the screen. Please refer to the table below for helpful guidance.
Error Code| Error Description|
Troubleshooting
---|---|---
E001| Inverter overload| Check if the power consumption of your devices is too
high. Reduce the load if necessary
E002| Temperature protection| Check if any of your devices are overheating.
Allow them to cool down before use.
E003| Inverter short circuit| Check if any of your electrical devices are
causing a short circuit. Disconnect and resolve the issue.
E004| Output failure| The output voltage is abnormal. Inspect the machine for
any malfunctions or irregularities.
E016| Fan failure| Check if the fan is blocked, unplugged, or not functioning
properly. Ensure proper ventilation.
E033| PV overvoltage| Make sure the PV input voltage is within the range of
12V-58VDC.
E065| Cigarette lighter output short circuit| Check if the power consumption
of your devices is too high. Reduce the load if necessary.
E068| Cigarette lighter output overtemperature| Wait for the device connected
to the cigarette lighter port to cool down.
E085| Charging temperature too low| Wait for the unit to cool down before
charging.
E086| Charging temperature too low| Make sure the unit is placed in an ambient
temperature of 0˫-40˫ (32°F-104°F).
E087| Grid under frequency| Wait for the unit to cool down before
discharging.
E088| Grid underfrequency| Make sure the unit is placed in an ambient
temperature of 0˫-40˫ (32°F-104°F).
E113| Grid under frequency| Check if the grid voltage is too high. Contact
your local power provider if necessary
E114| Grid under frequency| Check if the grid voltage is too low. Contact your
local power provider if necessary
E115| Grid under frequency| Check if the grid frequency is too high. Contact
your local power provider if necessary
E116| Grid under frequency| Check if the grid frequency is too low. Contact
your local power provider if necessary.
E117| Grid oscillation| Disconnect the grid input and contact BLUETTI support
for further assistance.
Others|
/
| Please contact BLUETTI support for assistance.
Appx. 1 Estimating Operation Time
To estimate the operation time of the AC70P, consider the load you’re applying:
- For high-power loads (above 300W): Operation time = Battery Capacity (Wh) x DoD x ę ÷ Load Power
- For small-power loads (below 300W):
Operation time = Battery Capacity (Wh) x DoD x ę ÷ (Load Power + Self- consumption of AC70P)
Note: DoD refers to depth of discharge. AC70P works at 90% DoD for longer battery life.
ę is the conversion efficiency of the inverter, typically over 85% for AC70P.
The self-consumption of AC70P is approximately 15W.
E.g. If you have a 40W refrigerator, you can run it for about 12 hours.
Operation time = 864Wh × 90% × 85% ÷ (40W + 15W) ≈ 12 hours.
Please keep in mind that the estimated operation time provided is for only purposes and may vary based on actual usage conditions. Factors such as low temperature and excessive loads can significantly affect the battery capacity, leading to a reduction in the average operation time.
Appx. 2 FAQs
Q1: How do I know whether my devices will work well with this product?
A: Please evaluate the total constant load of your devices. If it doesn’t exceed the Max. output power of AC70P (1000W), you can use this power station to run your devices. Note: Some devices with built-in motor or compressor may start at 2-4 times the rated power, which can easily overload the AC70P.
Q2:Can I use third-party solar panels to charge this product?
A; Yes, you can. However, make sure your solar panels have an open circuit voltage of 12V-58V and are equipped with MC4 connectors. It’s also important not to mix different types of solar panels.
Q3:Can it charge and discharge at the same time?
A:Yes. It supports pass-through charging. The AC70P comes with the premium LiFePO4 battery and proprietary Battery Management System to ensure that it can charge and discharge at the same time.
Q4:What is ECO Mode and can I turn it off?
A:ECO Mode helps save power, and you can turn it on or off on the screen. When operating on ECO Mode, the AC / DC output will automatically turn off if the AC70P is bearing low or no load for a while. You can set the power threshold of AC output and DC output to 10W-30W / 5W-10W, respectively, for 1, 2, 3, or 4 hours.
Q5:Why is the charging power often too low?
A:AC70P has a built-in intelligent BMS that automatically adjusts the charging power in response to the battery temperature and SoC, thus protecting the battery and extending its service life.
Appx. 3 FCC Statement
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
-
This device may not cause harmful interference.
-
This device must accept any interference received, including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio / TV technician for help.
FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment.
IMPORTANT NOTE: FCC Radiation Exposure Statement
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20cm between the radiator & your body
Appx. 4 IC Caution
This device contains licence-exempt transmitter(s) / receiver(s) that comply
with Innovation, Science and Economic Development Canada’s licence-exempt
RSS(s).
Operation is subject to the following two conditions:
- This device may not cause interference.
- This device must accept any interference, including interference that may cause undesired operation of the device.
RF exposure statement(WPT) : The equipment complies with IC Radiation exposure limits set forth for uncontrolled environments. This equipment should be installed and
operated with a minimum distance of 10cm between the radiator and your body.
RF exposure statement(BT): The equipment complies with IC Radiation exposure limits set forth for uncontrolled environments. This equipment should be installed and operated with a minimum distance of 20cm between the radiator and your body.
CAN ICES-3 (B)/NMB-3(B) (Canada)
This Class B digital apparatus complies with Canadian ICES-003.
Thank You!
Thank you for making BLUETTI a part of your family.
From the very beginning, BLUETTI has tried to stay true to a sustainable
future through green energy storage solutions while delivering an exceptional
eco-friendly experience for our homes and our world.
That’s why BLUETTI makes its presence in 100+ countries and is trusted by
millions of customers across the globe.
Copyright © Shenzhen PowerOak Newener Co., Ltd. All rights reserved.
No part of this document may be reproduced or transmitted in any form or by
any means without the prior written consent of Shenzhen PowerOak Newener Co.,
Ltd.
Notice
BLUETTI’s products, services, and features are subject to the agreed-upon
terms and conditions during purchase. Please note that some products,
services, or features described in this manual may not be available under your
purchase contract. Unless otherwise specified in the contract, BLUETTI makes
no representations or warranties of any kind, express or implied, with respect
to the contents of this manual.
The contents of this manual are subject to change without notice. Please get
the latest version from: https://www.bluettipower.com/pages/user-guides If
you have any questions or concerns about this manual, please contact BLUETTI
support for further assistance.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>