YougetTech EH22 Evaporative Humidifiers for Large Living Space Instructions

June 15, 2024
YougetTech

**YougetTech EH22 Evaporative Humidifiers for Large Living Space Instructions

**

IMPORTANT SAFEGUARDS

General Safety Instructions

READ BEFORE USING YOUR HUMIDIFIER

DANGER: means if the safety information is not followed someone will be seriously injured or killed.
WARNING: means if the safety information is not followed someone could be seriously injured or killed.
CAUTION: means if the safety information is not followed someone may be injured.

  1. To reduce the risk of fire or shock hazard, this humidifier has a polarized plug (one blade is wider than the other). Plug humidifier directly into a 110VAC electrical outlet. Do not use extension cords. If the plug does not fully fit into the outlet, reverse plug. If it still does not fit, contact a qualified electrician to install the proper outlet. Do not change the plug in any way.
  2. Keep the electric cord out of traffic areas. To reduce the risk of fire hazard, never put the electric cord under rugs, near heat registers, radiators, stoves or heaters.
  3. Always unplug the unit before moving, cleaning or removing the fan assembly section from the humidifier, or whenever it is not in service.
  4. Keep the humidifier clean. To reduce the risk of injury, fire or damage to humidifier, use only cleaners specifically recommended for humidifiers. Never use flammable, combustible or poisonous materials to clean your humidifier.
  5. Do not put foreign objects inside the humidifier.
  6. Do not allow the unit to be used as a toy, Close attention is necessary when used by or near children.
  7. To reduce the risk of electrical hazard or damage to humidifier, do not tilt, jolt or tip humidifier while the unit is running.
  8. To reduce the risk of accidental electrical shock, do not touch the cord or control with wet hands.
  9. To reduce the risk of fire, do not use near an open flame such as a candle or other flame source.

WARNING: For your own safety, do not use humidifier if any parts are damaged or missing.
WARNING: To reduce risk of fire, electric shock, or injury always unplug before cleaning.
WARNING: To reduce the risk of fire or shock hazard, do not pour or spill liquid into control or motor area. If control get wet, let it dry completely and have the unit checked before plugging in.

TECHNICAL PARAMETERS

Product: Evaporative humidifier
Voltage: 110VAC 60Hz
Model: EH22
Water capacity: 1.8 Gallons
Watts: 30W
Dimensions: 10.8″x10.8″x19″
Net weight: 10.2 lb
Mo del: EH22T
Water capacity: 3.9 Gallons
Watts: 60W
Dimensions: 21.2″x10.8″x19″
Net weight: 18.4 lb

CONTROL PANEL

  • Power key
    Plug in the power after the water tank is filled, touch the power key to turn on the humidifier. touch the power key to turn off

  • Humidification key
    Touch this key and cooperate with SET-or SET to change the speed from 1 to 7.1 sleeping mode, 7 is super strong mode. 2 and 6 are recommended for daily use.

  • Timer key
    Touch this key and cooperate with SET-or SET to change the Timer from 1h to 24h

  • SET-key
    Minus 1 with every touch.
    Humidification speed can set from 1 to 7; Humidity can set from 40% to 99%; Timer can set form Ih to 24h

  • SFT + key
    Plus 1 with every touch.
    Humidification speed can set from 1 to 7; Humidity can set from 40% to 99%, Timer can set from 1h to 24h

  • Lights off key
    After touch this key all the other indicators lights are turned off except this key and power

  • Water shortage indicator
    When the water level is low, the water shortage indicator lights up and alarms. The alarming lasts for 5 seconds then the machine will stop working.

Automatic Humidifying: The machine works at automatic humidifying mode. When the environment humidity degree reaches or exceeds the set humidity degree, the machine will stop working automatically, the present humidity degree flashes on the display screen; when the humidity degree comes 5 degree under the set humidity degree, the machine will start working again. Press” to change the set humidity degree from 40%-99% Defauct set degree is 65%

Keep humidifying: Press Key an”-“key simultaneously and” 99 “displays on the sereen, you can make the humidifier keep working. Under this mode, the machine is not controlled by the set humidity degree. Press either” “key or”-“key twice, the machine will return the automatic humidifying mode and the original set humidity degree

OPERATION

WARNING : To protect against fire, electric shock and injury do not immerse cord or plugs in to water or other liquid. Please place the product on a flat surface.
WARNING: To reduce risk of fire, electric shock, or injury always unplug before working or cleaning.

Adding Water

Suitable water: Daily Use Water, Mineral Water, Purified Water Adding Water from the mesh on the top cover with water bag or other cans, minding to keep the water level under the overflow hole.avoiding water adding onto the control panel.

The machine must be unplugged before adding water.

Drain Water

  • To prevent the water tank gets polluted and gives out odor, user can wipe the inside of the main body after it shows the water shortage. Do not pour out the water from the main body in order not to cause the machine damage.
  1. Move the humidifier to the bathroom or kitchen sink then remove drain plug.

  2. When the drain plug is removed, the water will flow out of the drain. hole. Be careful not to wet the floor.

UNINSTALL AND CLEAN THE DISHWATER FILM

Cleaning work cannot be operated until the machine fully stop and be unplugged.

  • The dishwater film should be cleaned if the machine is smelly or not used for long time.
  1. Press and unlock the top cover

  2. Turn up and remove the top cover

  3. Take out the film frame

  4. Take off the waterish film
    Take off the waterish film from the film frame, wash it weekly or when there is odor. Clean it with room temperature water and neutral clean lotion, dry it naturally, do not dry it by electrical drier or heavy sunshine, which will shorten the life span and affect the humidification performance.

TROUBLE SHOOTING

Problem Cause/Solution
I.Humidifier fails to work at all, no display in the control panel. 1.1 Check

that the Unit is plugged properly.
1.2 Check the power key and turn ON the unit.
2.Fan fails to work.| 2.1 Check that the Unit is plugged properly.
2.2 Water level is low and the water shortage protection works. Please add water and restart the humidifier.
2.3 Environment humidity degree reaches or exceeds the setting humidity degree. Please set the degree again or wait until the environment degree drop down.
3. Leakage of water.| 3.1 water tank damage.
3.2 overflow of filling water.
3.3 Adding water on Incorrect installed top cover.
3.4 Pour water from the main body directly.
4. E2,E3 error code displayed in the control panel.| Humidity sensor damaged or dropped off. Please change the humidity sensor or check the connector.

CLEANING AND MAINTANANCE

  • -The humidifier must be unplugged before cleaning or maintenance.
  • Do not clean it with chemicals, iron or wooden brushes or any similar materials.
  • CLEANING the outside surface with wet soft cloth and dry cloth.
  • CLEANING inside: remove the top cover, take out the waterish film and wash it clean.
  • CLEANING the water tank with wet soft cloth and wipe it clean with dry cloth.
  • The waterish film and water tank are suggested to clean once a week to prevent bacteria or bad odor..

PRECAUTION AND WARNING

Before installing and using the product, please read the manual carefully and follow the instructions hereunder:

  • The humidifier must be placed on a flat surface of floor or table.
  • The product must be unplugged off before moving or maintenance,
  • Do not block the air inlet and the air vent with any objects.
  • Do not put finger or any objects in the protective piece, the movable parts, the air inlet and the air outlet.
  • Do not let objects like hair or fabric near the unit, as these objects may get caught in and block the air inlets and outlets.
  • In case the cord wire damaged, maintenance must be operated by professional person.
  • Put the humidifier in the safe place too avoid children touching or pushing it.
  • The instrument is only applicable with power source of 110V~60Hz.
  • Connect the power plug with correct socket.
  • Do not pull the wire or touch the plug with wet hand.
  • Tilting the humidifier may cause water overflow. In this case, the humidifier must be unplugged to prevent electric shock, fire or other damage.
  • The humidifier must be unplugged if there is noise, odour, overheat or water leakage.
  • This appliance should not be used by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
  • Children shall not play with the appliance.
  • Cleaning and user maintenance shall not be operated by children without supervision.
  • Do not put the humidifier in water.

WARNING:

STOP USING THE HUMIDIFIER UNDER FOLLOWING CASES TO PREVENT ELECTRIC SHOCK, FIRE OR OTHER DAMAGE:

  • The humidifier is tilting or fallen.
  • There is water leakage.
  • The unit body is broken or with crack.
  • The instrument gives out noise, odour or high heat.