EU-C-8 Manufactured Tech Sterowniki User Manual

June 15, 2024
TECH STEROWNIKI

EU-C-8 Manufactured Tech Sterowniki User

Specifications

  • Model: EU-C-8f
  • Intended Use: Installation in heating zones
  • Function: Sends current floor temperature readings to the main controller
  • Color Versions: White and Black

Installation

  1. Before installing the sensor, plug the floor temperature sensor NTC into the EU-C-8f sensor. Polarity does not matter.
  2. Ensure that the floor sensor is properly connected to the EU-C-8f sensor.

Registering a EU-C-8f Sensor in a Zone

  1. Access the main controller menu and navigate to Zones/Floor heating/Registration.
  2. Select Registration and press the communication button on the EU-C-8f temperature sensor you want to register.
  3. If the registration attempt is successful, a confirmation message will be displayed on the screen, and the control light on the EU-C-8f sensor will flash twice.

Rules for Registering Sensors:

  • Only one temperature sensor can be registered in each zone.
  • If you attempt to register a sensor in a zone where another sensor is already registered, the first sensor will be unregistered and replaced by the second one.

Setting Maximum Temperature
For each temperature sensor assigned to a zone, you can set the maximum temperature above which the main controller will disable the floor heating to protect the floor.

Note: Only one room sensor should be assigned to each zone.

Safety

Before installation, ensure that the sensor and its cables are in good condition. Additionally, check if the controller is properly mounted and clean it if dusty or dirty.

Technical Data
Provided technical data is not available in the given text-extract.

Description

The EU-C-8f sensor is intended to be installed in heating zones. It sends current floor temperature readings to the main controller.

Color versions: white and black.

How to install

Before installing the sensor, plug the floor temperature sensor NTC to the EU-C-8f sensor. Polarity does not matter

How to register a EU-C-8f sensor in a given zone

  • Each sensor should be registered in the main controller in a particular zone – Zones/Floor heating/Registration. After selecting Registration, press the communication button on the selected temperature sensor EU-C-8f.
  • If the registration attempt has been successful, the screen will display a message to confirm and the control light on the EU-C-8f sensor will flash twice.

Bear in mind the following rules:

  • A maximum of one temperature sensor may be registered in each zone;
  • if the user attempts to register a sensor in the zone in which another sensor has already been registered, the first sensor becomes unregistered and it is replaced by the second one.

For each temperature sensor assigned to a zone, the user may set the maximum temperature above which the main controller will disable the floor heating to protect the floor.

NOTE: Only one room sensor should be assigned to each zone.
The pictures and diagrams are for illustration purposes only. The manufacturer reserves the right to introduce some changes.

Safety

Before using the device for the first time the user should read the following regulations carefully. Not obeying the rules included in this manual may lead to personal injuries or controller damage. The user’s manual should be stored in a safe place for further reference. To avoid accidents and errors it should be ensured that every person using the device has familiarized themselves with the principle of operation as well as security functions of the controller. If the device is to be sold or put in a different place, make sure that the user’s manual is there with the device so that any potential user has access to essential information about the device. The manufacturer does not accept responsibility for any injuries or damage resulting from negligence; therefore, users are obliged to take the necessary safety measures listed in this manual to protect their lives and property.

WARNING

  • The device should be installed by a qualified electrician.
  • The sensor should not be operated by children.
  • Before and during the heating season, the controller should be checked for condition of its cables. The user should also check if the controller is properly mounted and clean it if dusty or dirty.

Technical data

  • Sensor type. …………………………………………………………………..NTC
  • Temperature measurement range ………………………………….-30÷500C
  • Communication frequency …………………………………………….868 MHz
  • Power supply …………………………………………….2xbatteries 1,5V AAA
  • Measurement accuracy. ………………………………………………..+/-0,50C

We are committed to protecting the environment. Manufacturing electronic devices imposes an obligation of providing for environmentally safe disposal of used electronic components and devices. Hence, we have been entered into a register kept by the Inspection For Environmental Protection. The crossed-out bin symbol on a product means that the product may not be disposed of to household waste containers. Recycling of wastes helps to protect the environment. The user is obliged to transfer their used equipment to a collection point where all electric and electronic components will be recycled.

WARRANTY CARD

TECH STEROWNIKI II Sp. z o.o. company ensures to the Buyer proper operation of the device for 24 months from the date of sale. The Guarantor undertakes to repair the device free of charge if the defects occurred through the manufacturer’s fault. The device should be delivered to its manufacturer. Principles of conduct in the case of a complaint are determined by the Act on specific terms and conditions of consumer sale and amendments of the Civil Code (Journal of Laws of 5 September 2002).

CAUTION! THE TEMPERATURE SENSOR CANNOT BE IMMERSED IN ANY LIQUID (OIL ETC.). THIS MAY RESULT IN DAMAGE TO THE CONTROLLER AND LOSS OF WARRANTY! THE ACCEPTABLE RELATIVE HUMIDITY OF THE CONTROLLER’S ENVIRONMENT IS 5÷85% REL.H. WITHOUT THE STEAM CONDENSATION EFFECT. THE DEVICE IS NOT INTENDED TO BE OPERATED BY CHILDREN.

Activities related to setting and regulation of the controller parameters described in the Instruction Manual and parts wearing out during normal operation, such as fuses, are not covered by warranty repairs. The warranty does not cover damages arising as a result of improper operation or through the user’s fault, mechanical damage or damage created as a result of fire, flood, atmospheric discharges, overvoltage or short-circuit. The interference of an unauthorized service, wilful repairs, modifications, and construction changes cause the loss of the Warranty. TECH controllers have protective seals. Removing a seal results in the loss of Warranty.

The costs of an unjustifiable service call to a defect will be borne exclusively by the buyer. An unjustifiable service call is defined as a call to remove damages not resulting from the Guarantor’s fault as well as a call considered unjustifiable by the service after diagnosing the device (e.g. damage of the equipment through the fault of the client or not subject to Warranty), or if the device defect occurred for reasons lying beyond the device. To execute the rights arising from this Warranty, the user is obliged, at his own cost and risk, to deliver the device to the Guarantor along with a correctly filled-in warranty card (containing, in particular, the sale date, the seller’s signature, and a description of the defect) and sales proof (receipt, VAT invoice, etc.). The Warranty Card is the only basis for repair free of charge. The complaint repair time is 14 days. When the Warranty Card is lost or damaged, the manufacturer does not issue a duplicate.

EU Declaration of conformity
Hereby, we declare under our sole responsibility that EU-C-8f manufactured by TECH STEROWNIKI II Sp. z o.o., head-quartered in Wieprz Biała Droga 31, 34-122 Wieprz, is compliant with Directive 2014/53/EU of the European parliament and of the Council of 16 April 2014 on the harmonization of the laws of the Member States relating to the making available on the market of radio equipment, Directive 2009/125/ EC establishing a framework for the setting of ecodesign requirements for energy-related products as well as the regulation by the MINISTRY OF ENTREPRENEURSHIP AND TECHNOLOGY of 24 June 2019 amending the regulation concerning the essential requirements as regards the restriction of the use of certain hazardous substances in electrical and electronic equipment, implementing provisions of Directive (EU) 2017/2102 of the European Parliament and of the Council of 15 November 2017 amending Directive 2011/65/EU on the restriction of the use of certain hazardous substances in electrical and electronic equipment (OJ L 305, 21.11.2017, p. 8).

For compliance assessment, harmonized standards were used:

  • PN-EN IEC 60730-2-9 :2019-06 art. 3.1a Safety of use
  • PN-EN 62479:2011 art. 3.1 Safety of use
  • ETSI EN 301 489-1 V2.2.3 (2019-11) art.3.1b Electromagnetic compatibility
  • ETSI EN 301 489-3 V2.1.1:2019-03 art.3.1 b Electromagnetic compatibility
  • ETSI EN 300 220-2 V3.2.1 (2018-06) art.3.2 Effective and coherent use of radio spectrum
  • ETSI EN 300 220-1 V3.1.1 (2017-02) art.3.2 Effective and coherent use of radio spectrum
  • EN IEC 63000:2018 RoHS.

FAQ

  • Q: Can I install multiple temperature sensors in a single zone?
  • A: No, only one temperature sensor can be registered in each zone.
  • Q: What happens if I try to register a sensor in a zone where another sensor is already registered?
  • A: The first sensor will be unregistered, and the second sensor will replace it.
  • Q: How do I set the maximum temperature for floor heating?
  • A: For each temperature sensor assigned to a zone, you can set the maximum temperature above which the main controller will disable the floor heating to protect the floor.
  • Q: Can I assign multiple room sensors to a single zone?
  • A: No, only one room sensor should be assigned to each zone.

MORE INFORMATION

  • Central headquarters:
    ul. Biata Droga 31, 34-122 Wieprz

  • Service:
    ul. Skotnica 120, 32-652 Bulowice

  • phone: +48 33 875 93 80

  • e-mail: serwis@techsterowniki.pl

Read User Manual Online (PDF format)