Madeira 10 L Air Dehumidifier User Manual

June 15, 2024
Madeira

Madeira 10 L Air Dehumidifier

Madeira-10-L-Air-Dehumidifier-PRODUCT

Product Information

Specifications

  • Model: Notos 10 L / Tanimara 20 L
  • Voltage: 220-240 V~
  • Frequency: 50Hz
  • Power Consumption: Notos 10 L – 175 W, Tanimara 20 L – 390 W
  • Water Tank Capacity: 2 liters
  • Refrigerant: Notos 10 L – R290/40g, Tanimara 20 L – R290/75g
  • Coverage Area: Notos 10 L – 15-18 m2, Tanimara 20 L – 20-25 m2
  • Noise Level: Notos 10 L – 42 dB(A), Tanimara 20 L – 48 dB(A)
  • Dimensions: 292 x 501 x 190 mm

Product Usage Instructions

Safety Instructions

  1. Before using the product, carefully read and follow all safety instructions provided in this manual.
  2. This product should not be used by children without adult supervision.
  3. The product should only be used in accordance with national regulations and guidelines.

Cleaning and User Maintenance

  1. To clean the air intake grille, make sure there is no dirt or debris blocking it.
  2. Empty the water tank every two weeks to prevent overflow.

Operation

  1. Connect the power cable to a suitable power outlet.
  2. To turn on the dehumidifier, press the power button (E) on the control panel.
  3. Use the UP (B) and DOWN (H) buttons to adjust the desired humidity level.
  4. The dehumidifier can be set to automatic or continuous mode using the MODE button (G).

Emptying the Water Tank

  1. When the water level warning light (F) illuminates and “FL” is displayed, it is time to empty the water tank.
  2. Carefully remove the water tank (7) and empty it.
  3. Make sure the tank is securely reinserted before resuming operation.

Using a Drainage Hose

  1. The dehumidifier can be continuously drained using a drainage hose.
  2. Make sure the hose is securely attached and that water can flow freely.

FAQs

How often should I clean the air intake grille?
The air intake grille should be cleaned regularly to maintain optimal performance. We recommend checking for dirt or debris every month and cleaning as necessary.

Can I use this dehumidifier in my basement?
Yes, this dehumidifier is suitable for use in basements.

How do I switch between automatic and continuous mode?
To switch between automatic and continuous mode, press the MODE button (G) on the control panel.

Thank you!
We are convinced that this appliance will exceed your expectations and wish you joy while using it. Please read this user manual completely and observe the safety instructions.

Scope of delivery

  • 1x Air dehumidifier
  • 1x HoseMadeira-10-L-Air-Dehumidifier-FIG- \(1\)

If any parts are missing or damaged, please contact your HORNBACH Store.

Symbols
The appliance contains the refrigerant R290, which is a flammable product. It shall be installed, operated, and stored in a room with a floor area larger than 4.0 m2.

Please read this user manual carefully and keep it for further reference.
Service personnel should handle the equipment according to the installation manual.

Safety Instructions
Important safety instruc-tions. Please read these safety instructions carefully before using the appliance. Keep this manual in a convenient place so you can always refer to it for the safe and proper use of the application. Please make sure to pass it on to any new owner of this appliance so he can become familiar with it and the safety warnings.

Always observe the safety instructions. Failure to follow the warnings and instructions may result in electric shock, fire, and/or serious injury. The producer is not responsible for any damage or injuries that may result of it.

  1. This appliance can be used by children aged 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Cleaning and user maintenance shall not be made by children without supervision. Children shall not play with the appliance.
  2. Ensure to always transport the appliance in an upright position.
  3. Before using for the first time, ensure that the appliance has been positioned upright on its final position for at least 4 hours. Not doing so will void your warranty claim.
  4. The appliance is not intended for commercial use.
  5. This appliance fulfills all current safety standards and must be treated with care.
  6. Always use the appliance as described in the intended use. Do not use the application in the following cases:
    • near a fire
    • with defective main plugs
    • outdoors or in direct sunlight
    • near water and spraying water like bathtubs, showers, or pools.
    • with extension cords or frame connectors
    • when the appliance is defective
    • as construction dryer or in rooms with strong particulate pollution
  7. Always plug the appliance into a mains outlet meeting the requirements described in the technical data or the rating plate on the back of the appliance.
  8. Ensure to connect the appliance only to a grounded mains plug.
  9. Do not use the appliance in an altitude of more than 2000 m above sea level.
  10. Compliance with national gas regulations shall be observed.
  11. The appliance shall only be stored in rooms without a permanent ignition source.
  12. Escaping refrigerant can cause frostbite, irritate the respiratory passages or lead to a loss of consciousness and to suffocation.
    • Avoid contact with the refrigerant.
    • Prevent damage to refrigerant lines.
  13. The appliances are provided with the refrigerant R290. This refrigerant is an ecologically friendly, but flammable product. The appliance is only to be operated or stored in a room with a floor area of min. 4.0 m2. The appliance must only be operated within the temperature range of 5 ° to 32 °C. Additionally, the following indications concerning appliances containing refrigerant R290 need to be followed:
    • Do not damage the refrigerant circuit. Escaping refrigerant can catch fire.
    • In case of escaping refrigerant, keep any kind of open fire sources well away and ventilate the room thoroughly.
    • Turn off the appliance immediately.
    • Do not pull the plug out of the mains, as this can become a source of ignition.
  14. The system contains refrigerant under high pressure and shall only be maintained by the manufacturer or similarly qualified persons.
  15. Warning: Refrigerants can be odorless!
  16. Before cleaning or maintaining the appliance, please turn it off and pull the power plug.
  17. Always clean the appliance with cleaning agents recom-mended by the manufacturer. Do not use any means or substances other than those recommended by the manufacturer to speed up the defrost process.
  18. Do not insert or pull out the power plug with wet hands.
  19. If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similarly qualified person in order to avoid a hazard. Never operate the appliance with a defective supply cord.
  20. Never cover the appliance with a towel or anything similar. Keep air inlet and air outlet clear of obstacles.
  21. Keep children from playing or climbing on the appliance.
  22. Do not repair or disassemble the air conditioner by yourself.
  23. Always keep the appliance in an upright and stable position. Do not place any objects on the appliance.
  24. Prohibit inserting any fingers or objects into the appliance. Take special care with children. The functionality of the appliance could be damaged.
  25. Children and disabled people are not allowed to use the unit without supervision.
  26. Close doors and windows when operating the appliance, so that it can work effectively.
  27. Empty the water tank renat Please observe high humidity can cause the water tank to fill quickly.
  28. The filter on the backside of the appliance must be cleaned regularly to guarantee an optimal air inlet.

Cabling

Check that cabling will not be subject to wear, corrosion, excessive pressure, vibration, sharp edges, or any other adverse environmental effects. The check shall also take into account the effects of aging or continual vibration from sources such as compressors or fans. Removal and evacuation When breaking into the refrigerant circuit to make repairs – or for any other purpose – conventional procedures shall be used. However, it is important that best practice is followed since flammability is a consideration.

The following procedure shall be adhered to:

  • remove refrigerant;
  • purge the circuit with inert gas;
  • evacuate;
  • purge again with inert gas;
  • open the circuit by cutting or brazing.

The refrigerant charge shall be recovered into the correct recovery cylinders. The system shall be “flushed” with OFN to render the unit safe. This process may need to be repeated several times. Compressed air or oxygen shall not be used for this task.

Flushing shall be achieved by breaking the vacuum in the system with OFN and continuing to fill until the working pressure is achieved, then venting to the atmosphere, and finally pulling down to a vacuum. This process shall be repeated until no refrigerant is within the system. When the final OFN charge is used, the system shall be vented down to atmospheric pressure to enable work to take place. This operation is absolutely vital if brazing operations on the pipe-work are to take place.

Charging procedures
In addition to conventional charging procedures, the following requirements shall be followed.

  • Ensure that contamination of different refrigerants does not occur when using charging equipment. Hoses or lines shall be as short as possible to minimize the amount of refrigerant contained in them.
  • Cylinders shall be kept upright.
  • Ensure that the refrigeration system is earthed prior to charging the system with refrigerant.
  • Label the system when charging is complete (if not already).
  • Extreme care shall be taken not to overfill the refrigeration system.

Prior to recharging the system, it shall be pressure tested with OFN. The system shall be leak tested on completion of charging but prior to commissioning. A follow-up leak test shall be carried out prior to leaving the site.

  • Only set up the device in a room in which there is no source of ignition present (e.g. open flames, a gas appliance or an electric heater).
  • Do not pierce or burn.
  • Every person working with or at the refrigerant circuit must be able to provide a certificate of qualification issued by a body accredited by the industry, demonstrating their competence in the safe use of refrigerants based on a procedure well-known in the industry.
  • Service work may only be carried out in accordance with the manufacturer’s specifications. If maintenance and repair work requires the support of additional persons, the person trained in handling flammable refrigerants shall continuously supervise the work carried out.

Product Overview

Air dehumidifier

  1. Control panel
  2. Air outlet grille
  3. Handle
  4. Housing
  5. Rolls
  6. Power supply cord
  7. Water tank
  8. Condensation drain
  9. Intake grille

Control panel

  • Display
  • Control UP
  • Fan speed
  • Timer
  • On/ off button
  • Water level control
  • Mode button
  • Control DOWN

Setup

  • Use the handles 3. to carry the dehumidifier
    Note : Close all doors, windows and other openings for efficient usage.

  • The dehumidifier can also be rolled by its rolls 5.
    Caution! Make sure that the dehumidifier stands on a flat and even floor.

Intended Use

This tool is:

  • used to prevent moisture damage to objects or dwellings;
  • used to support drying wet laundry;
  • only allowed to be used indoors, e.g. in living rooms, cellars, bathrooms, laundry rooms etc.;
  • to be operated at temperatures from 5 °C to 32 °C;
  • to use according to the descriptions and safety instructions indicated in this operating manual.

The appliance is not intended for commercial use. Any other use or modification to the appliance is considered improper use and could cause considerable dangers.

Empty the water tank

  1. Carefully pull out the water tank 7 to avoid spilling water.
    Caution! If water appears to be inside the appliance, empty the water tank and let the appliance dry.

  2. Empty and reinstall the water tank 7. Make sure it is installed properly.

Remove intake grille

  1. For cleaning the intake grille 9 (see “Care and Maintenance”), push the two flaps holding it and remove it.
  2. Install intake grille
    Push the intake grille 9 gently onto the housing until it clicks into place.

Open the air outlet grille

  1. When putting the appliance into operation, open the flap of the air outlet grille 2 by pushing it open at the mark labeled with PUSH.
  2. Close the air outlet grille
    Close the air outlet grille 2 by pushing down the flap.

Switch on

  1. Insert the power supply cord 6 into a suitable wall socket.
    Caution! Do not plug the appliance into a multiple socket with other devices.

  2. Switch off
    Press the on/ off button E to switch off the appliance.
    Note : Wait 3 minutes until switching on the appliance again.

Use the condensation drain

  1. Condensation water can permanently be derived with a drainage hose.
  2. Make sure that the hose is attached firmly and ensure an unhindered water drain.

Using the appliance

Warning! Never cover the appliance during operation. This could lead to heat accumulation or fire and damage to your appliance. Make sure no water can drop into the appliance.

  • Switch On/Off
    Press ON/OFF button (E). The current humidity level in the room is shown in the display (A).

  • Mode
    Press MODE (G) to switch between automatic and continuous dehumidi-fi cation.

  • Setting humidity level
    Ensure that the appliance is in Auto mode. Press UP (B) or DOWN (H) to set the desired humidity level. The appliance will start to work until the desired level is reached.

  • Fan speed
    Press WIND (C) to switch between highly efficient (hi efficient) and silent (Silent) fan speed.Madeira-10-L-Air-Dehumidifier-FIG-
\(10\)

  • Set timer
    To run the dehumidifier for a pre-set amount of hours, press TIMER (D).”0″ blinks on the display. Set the time you wish the appliance to operate between 1 and 24 hours.

  • Empty the container
    If “Water full” lights up and the display shows “FL”, the water tank needs to be emptied (see “Empty the water tank”) After reinstalling the emptied water tank, the dehumidi-fi er restarts automatically after three minutes.

  • Placement guidelines
    The dehumidifier should be used in closed rooms for efficient work. When operating the appliance, keep doors, windows and other openings closed. Make sure to maintain distances of 40 cm upwards and 50 cm side-swards for free air circulation The dehumidifier can support dry-ing laundry. Make sure to maintain distances of ≥50 cm on all sides to the wet laundry. Do not operate the dehumidifier near dryers, heaters, or radiators.Madeira-10-L-Air-
Dehumidifier-FIG- \(11\)

Care & Maintenance

Warning! Make sure the appliance is switched off and unplugged.

Cleaning the housing

  • Clean the housing regularly with a moist cloth and a mild cleaning detergent.
  • Check and clean the grille monthly to avoid performance reduction due to dust and dirt.
  • Never use solvents; these could attack the plastic parts of the equipment.
  • Ensure that no water can seep into the device.

Cleaning the filter

  • Make sure that no dirt gets into the appliance: Clean the supply air grille once a month using a soft brush.
  • Ensure that the grille is completely dry before inserting it into the dehumidifier.
  • Do not put the grille into the dishwasher.

Cleaning the water tank

  • Clean the water tank every 2 weeks to avoid deposits of algae, mold or bacteria.
  • Gently pull out the water tank from the dehumidifier and fill the tank partly with water and a mild cleaning detergent. Clean, empty and rinse the water tank thoroughly.
  • Do not put the water tank into the dishwasher.

Technical Data

Noise
The values given in these instructions have been measured in accordance with a standardized measurement procedure and can be used to compare appliances. It may be used for a preliminary  assessment of exposure.

Storage

  1. Clean the appliance, the water tank, and the grilles before covering it with plastic foil.
  2. Store the appliance in a dry and frost-proof place.
  3. Ensure to store the appliance in a room with a dimension of min. 25 – 30 m3.
  4. The appliance shall only be stored in rooms without a permanent ignition source.

Replacement Parts

Warning! Replacement parts must conform with the requirements specified by the manufacturer. Therefore use original replacement parts only or spare parts authorised by the manufacturer.

In case of service requests or spare parts, please contact your local HORNBACH store or write an email to: service@hornbach.com

Troubleshooting

Madeira-10-L-Air-Dehumidifier-FIG- \(16\)

Error and safety codes

Madeira-10-L-Air-Dehumidifier-FIG- \(17\)

In case of service requests please contact your local HORNBACH store or write an email to: service@hornbach.com

Disposal
The crossed-out wheeled bin symbol requires separate disposal for waste electrical and electronic equipment (WEEE). Such equipment may contain valuable, but dangerous and hazardous substances. You are required by law to return these products to a designated collection point for the recycling of WEEE and must not under any circumstances dispose of them as unsorted municipal waste. In this way, you can help to conserve resources and protect the environment.

In Germany, HORNBACH is obliged:

  • to take back old appliances of the same type free of charge in HORNBACH stores when you purchase a new electrical or electronic appliance.
  • to take back up to 3 WEEE of the same type (up to max. 25 cm edge length) free of charge in HORNBACH stores, even if you do not purchase a new appliance.
  • when delivering a new electrical or electronic appliance to a private household, to collect an old appliance of the same type free of charge or to enable you to return it in your immediate vicinity.

For further details, please consult www.hornbach.com or your local authorities. The dismantling and disposal, especially the disposal of the refrigerant, are to be carried out exclusively by the manufacturer or by similarly qualified persons.

Children must not play with plastic bags and packaging material, due to the risk of injury and suffocation. Store such material safely or dispose of it in an environmentally friendly way.

Manufactured for HORNBACH Baumarkt AG Hornbachstraße 11 76879 Bornheim / Germany

Notos-10L_Tanimara-20L_2023/07_V2.6