INSTALLATION GUIDE

F-ROOF Slate Roof Mounting System

Fastensol F-ROOF Slate Roof Mounting System - Fig

Natural & Aitificial Slate

Fastensol F-ROOF Slate Roof Mounting System -
Aitificial INSTALLATION GUIDE

Allow a maximum of 1.2m between tile brackets depending on site conditions.
6.3*100mm wooden screw with the washer

Top:
Bottom:
EDPM Washer CT! Sealant

RAFTER PSN CENTRAL
Sealed with CT1. See above
Fastensol F-ROOF Slate Roof Mounting System - Pre
drill

Pre drill the base plate with a 7mm drill.
Pre drill the slate covering with a 10mm drill.
Apply CT1 Sealant to the 7mm holes, bottom of the base.
Ensure slate surface is clean of dirt, dust, alge and moss etc.
Apply CT! Sealant. po Not USE ANY OTHER SEALANT

SCREW/ COLLAR SPACER INSTALLATION

Prevents pressure being applied by the screw fixing to the tile/slate covering Fastensol F-ROOF Slate Roof Mounting System - Collar

DRAWING AND BOM OF A-SLATE AS FOLLOW:

Fastensol F-ROOF Slate Roof Mounting System - DRAWING AND
BOM

BOM

Name| Spec| Material| QtY
Base| 16426560mm| Material Aluminum 6005-15| 1 pcs
L- Bracket| 607080mm|  Aluminum 6005-15| 1 pcs
Rubber Pad| 164265mm| EPDM| 1 pcs
 Screw| St6.3
100| Steel 10B21| 2 pcs

THE INFORMATION OF SPACER AS FOLLOWS:

10mm X 8.2mm X 20mm Spacers – Black Nylon Technical Specification

Fastensol F-ROOF Slate Roof Mounting System - SPACER

Finish Black
Inside diameter (B) 8.2mm
Length (1.) 20mm
Manufacturing Standard Not Standardised
Material Nylon
Material Specification UL94 HB Nylon 6,25% Glass Filled PMS-173
Metric or Imperial? Metric
Outside Diameter (D) 10mm

PROCEED WITH INSTALL OF A-SLATE AS FOLLOWS:

  1. After locating the battens, B1 & B2 and rafter R positions. Mark the test hole position X as shown, away from the battens B1 and B2
  2. Drill out a 7mm test ho Using a screw driver, gently. confirm the rafters central position.
  3. Place aluminum bases in the fixing position as shown. Hold and drill through the 2 marked fixing points X using a 7mm tile drill enough to mark the slate surfaces.Fastensol F-ROOF Slate Roof Mounting System - two marked
  4. Drill out the two marked fixing hole positions with a 7 mm drill.Fastensol F-ROOF Slate Roof Mounting System - Drill out 01
  5. Drill out the 7mm fixing holes to 10mm. Not the test hole.Fastensol F-ROOF Slate Roof Mounting System - Apply CT1
  6. Apply CT1 sealant into and around the fixing holes and test hole
  7. Insert spacers supplied intoboth fixing holes to be the level with the slates surface.
  8. Apply CT1 sealant around the bottom of two fixing holes of thealuminum bases.Fastensol F-ROOF Slate Roof Mounting System - rubber pad
  9. Put the rubber pad under the aluminum bases and fix the aluminum brackets into place using 2 x 6.3*100mm wooden screw, then Apply CT1 sealant around the top of 2 wooden screws again.