Coopers OF STORTFORD LDSSQ6C 6 Inch Shallow Square New Construction Downlight User Guide

June 15, 2024
Coopers OF STORTFORD

Coopers OF STORTFORD LDSSQ6C 6 Inch Shallow Square New Construction

Downlight

Top Product Features

  • 250-4000 lumens; Offered in 90 and 97 CRI; ENERGY STAR® qualified
  • Easy disconnect for LED engine replacement and installation
  • Optional snap in driver for ease of replacement
  • Standard 0-10V driver dims to 1%
  • 2400K, 2700K, 3000K, 3500K, 4000K, 5000K; D2W™ option from 3000K to 1850K
  •  Available W2N tunable white CCT range 2700K to 6500K or 2000K to 5000K

Dimensional and Mounting Details

Single Line Order Information

SAMPLE ORDER NUMBER: LDSSQ6C109030D010SQ1LI

The invoice will indicate separate fixture components (housing, trim, module) which will ship complete from a single CLS facility in separate cartons. To receive separate components (housing, trim, module) shipment, click on the “Multi-Line Ordering Information Option” button to the right.

| | |
---|---|---|---
Housing| Lumen (1)| Color Control| CCT (11)
LDSSQ6C =LED Shallow Square Downlight 6” Nominal Aperture| 02 = 250 lumens, IC rated| 20 = 2000 Lumens| 90 =90 CRI Minimum| 90 CRY __

24 =2400K

27 =2700K

30 =3000K

35 =3500K

40 =4000K

50 =5000K

| 97 CRI __

27 =2700K

30 =3000K

LDSSQ6CCP =LED Shallow Square Downlight 6” Nominal Aperture,| 05 = 500 lumens, IC rated| 25 = 2500 lumens| 97 =97 CRI Minimum
Chicago Plenum| 08 = 800 lumens, IC rated| 30 = 3000 Lumens|
| 10 = 1000 Lumens| 35 = 3500 lumens|
| 10IC = 1000 Lumens, IC rated| 40 = 4000 lumens|
| 15 = 1500 Lumens| |
| 15IC = 1500 Lumens, IC rated| |

| |
---|---|---
Driver| Driver Options| Hanger Bars
D010 = 0-10V Dimming, 1% to 100%, 120V-277V up to 4000 lumens

3D010 =0-10V Dimming, 1% to 100%, 347V dedicated drivers for 800 to 4000 lumens; 250 and 500 use step down transformer

| Blank = Standard mount driver

PD = Plug in Driver (17)

| Blank = Without hanger bars B26 = C-channel Bar Hanger, 26” Long, Pair
D010TR =0-10V (120-277V) or Line Voltage (120V) dimming, 5-100%, 250- 4000 lumens (up to 3000 lumens for remote driver)

3D010TR =0-10V Dimming, 5% to 100%, 347V step down transformer 250-4,000

DE010 = 0-10V Dimming, 0% to 100%, 120V-277V 500-4000 lumens

3DE010 =0-10V Dimming, 0% to 100%, 347V step down transformer 500-4000 lumens

D5LT = Fifth Light® (DALI T6) Logarithmic Dimming, 0% to 100%, 120V-277V, 500-4000 lumens

3D5LT =Fifth Light® (DALI T6) Logarithmic Dimming, 0% to 100% 347V step down transformer, 500-4000 lumens

DMX = DMX/RDM Logarithmic Dimming, 0% to 100%, 120V-277V 800-4000 lumens (6)

3DMX =DMX/RDM Logarithmic Dimming, 0% to 100%, 347V step down transformer, 800-4000 (6)

DMXC5 = DMX/RDM Logarithmic Dimming, 0% to 100%, 120V-277V, 800-4000 lumens, RJ45 Connection (6)

3DMXC5 =DMX/RDM Logarithmic Dimming, 0% to 100%, 347V step down transformer, 800-4000, RJ45 Connection (6)

DLE = Lutron Ecosystem dimming 1% to 100%, 120V-277V, 800-3500 lumens

3DLE =Lutron Ecosystem dimming 1% to 100%, 120V-277V, step down transformer, 800-3500 lumens

DLV = Low voltage dimming driver (1-100%) for use with DLVP system 800-3000 lumens (3)
| | |
---|---|---|---
Trim Distribution (5)| Trim Flange| Trim Finish| Options (3) **(8)
CSSQ =Cast Shallow Square, Die Cast Aluminum| 1** =Self-flanged (5)

2 =White Painted Self-flanged

3 = Flangeless for use with plaster lathing ring

4 =Knife edge rimless use with die-cast only (13)

| MW =Matte White (Antimicrobial)

MB =Matte Black

MMS =Matte Metallic Silver

| EM6 =6W Emergency Module with Remote Test Switch

WPN = WaveLinx PRO Wireless Node without sensor (11)

PSSQMW1 =Non-Conductive Shallow (dead front), Self Flanged, White (16)


Accessories ( Sold separately ) (18)
LGSKT6SQIP66 =IP66 Gasket Kit

PRSQ6 = Rimless Plaster Ring (2) RPMSQ6MW =Rimless Millwork Ring, Matte White (2)  RPMSQ6MB =Rimless Millwork Ring, Matte Black (2) RKPSQ6 = Knife Edge plaster Ring (14)

RKMSQ6MW =Knife Edge Millwork Ring, Matte White (14)

RKMSW6MB =Knife Edge Millwork Ring, Matte Black (14)

| Bar Hangers

HB50 =C-channel Bar Hanger, 50” Long, Pair

RMB22 =Wood Joist Bar Hanger, 22” Long, Pair

__

Connected Lighting Systems (3) **(7)**

WPST = Field installed WaveLinx Sensor Kit (9)

WLST = Field installed WaveLinx LITE Sensor Kit (10)

Notes:

  1. Nominal Lumens will vary depending on the selected color, CRI, driver, and reflector finish. Reference Multiplier tables.
  2. Order trim with flange type 3.
  3. Not available with Chicago Plenum.
  4. ULus listed only
  5. The flange is the same finish as the reflector
  6. DMX fixtures default to full-on upon loss of DMX signal
  7. Refer to system specifications for additional information, features, and benefits. Use with 0-10V driver.
  8. Non-IC
  9. WLST = WaveLinx LITE tile mount sensor kit for daylight dimming, PIR motion sensing, use with D010 only (Refer to WaveLinx LITE system specifications)
  10. WPST = WaveLinx wireless sensor kit for daylight dimming, PIR motion sensing, and optional RLTS – Real Time Location Services, use with 0-10V only.
  11.  WPN = WaveLinx PRO wireless node provides luminaire-level control with scene and zone configuration without an integrated sensor; Connects wirelessly with daylight dimming sensor and PIR motion sensor if desired. Use with 0-10V driver only.
  12. Accessory (Requires knife edge accessory ring)
  13. Order die-cast trim with flange type 4
  14. Limited to 2000 lumens
  15. Not available with DLVP
  16.  Accessories sold separately will be separately analyzed under domestic preference.

Product Specifications

Lower Shielding Reflector

  • Painted die-cast aluminum lower reflector with medium beam or medium beam 45° cutoff with a lensed upper optical chamber providing superior lumen output with minimal source brightness.
  • The reflector is retained with two torsion springs holding the flange tight to the finished ceiling surface.
  • Plaster lathing ring, knife edge and millwork ring accessory for flush reflector transition

Trim Retention

  • Two torsion springs hold the reflector flange tightly to the finished ceiling surface

Plaster Frame/Collar

  • Galvanized steel plaster frame with adjustable collar adjusts for up to 2” thick ceilings and rotates+/- 7.5

Universal Mounting Bracket

  • Accepts 1/2” Electric Metallic Tube (EMT), C-channel and bar hangers
  • Adjusts 5” vertically from above and below the ceiling

Junction box

  • Four 1/2” and two 3/4” trade size pry outs positioned to allow straight conduit runs
  • Lever connectors for simple push-in wiring
  • Listed for (4) #12 AWG (two in, two out) 90°C conductors and feed thru branch wiring for type IC and Plug-in drivers for 120/277V only. For all other cases (8) #12 AWG (four in, four out)
    90°C conductors and feed thru branch wiring for 120/277V only

Thermal

  • The aluminum heat sink conducts heat away from the LED module for improved performance and longer life

LED System

  • Contains a plurality of high brightness white LED’s combined with a high reflectance upper reflector and convex transitional lens producing even distribution without pixilation
  • Auto resetting, thermally protected, LEDs are turned off when safe operating temperatures are exceeded
  • Quick disconnect allows for tool-less replacement of LED engine from below the ceiling
  • 90 and 97 CRI
  • 90 & 97CRI: L78 55,000 hours for 1000-2000 lumens, L90 55,000 for all other lumen output
  • Color variation within 2-step MacAdam ellipses
  • Available in 2400K, 2700K, 3000K, 3500K, 4000K and 5000K correlated color temperature (CCT)

Vividtune and High CRI

  • 98 CRI and W2N: L70 55,000 hours
  • D2W™ – dim-to-warm shifts CCT from 3000K to 1850K as fixture dims mimicking halogen sources.
  • W2N – Tunable white CCT range 2700K to 6500K or 2000K to 5000K, 90 CRI. Standard
  • 98 CRI With a full-spectrum approach using broad blue chip technology and special phosphor blends, Thrive is able to closely match the spectrum of the sun across all color temperatures. Benefits of the natural spectrum of the sun using Thrive include superior accurate color rendering, reduced eye strain, and a higher sense of emotional well-being.
  • See the dedicated specification sheet for more details.

Driver

  • Standard 120-277V 0-10V dimming driver provides flicker-free dimming from 100% to 1%
  • Optional 120V leading edge/0-10V, <1% 0-10V, Fifth Light, DMX or Lutron® Ecosystem
  • The driver can be serviced from above or through the aperture
  • Distributed low-voltage power system combines power, lighting, and controls with ease of installation.
  • Optional magnetically guided snap in the driver for ease of maintenance.

Emergency Option

  • 6W battery provides 90 mi notes of standby lighting, meeting most life safety codes for egress lighting
  • UL 924 listed

Connected Lighting System

Two WaveLinx connected solutions to choose rom. Refer to WaveLinx system specifications and application guides for details.
WaveLinx PRO Tilemount Sensor Kit

  • WaveLinx WPST tile mount sensor kit offers daylight dimming, PIR motion sensing, scene and zone configuration, automatic commissioning; and optional RLTS – Real-Time Location Services available.

WaveLinx PRO Wireless Node

  • WaveLinx PRO wireless node provides luminaire level control with scene and zone configuration without an integrated sensor; Connects wirelessly with daylight dimming sensor and PIR motion sensor if desired. Use with 0-10V driver only.

WaveLinx LITE Tilemount Sensor Kit

  • WaveLinx LITE WLST tile mount sensor kit offers daylight dimming and PIR motion sensing, scene, and grouping configuration.

WaveLinx Tilemount Kits Application

  • The WPST and WLST tile mount kits include a control module mounted on the luminaire junction box via 1/2” knock-out and a tile mount sensor on a 54-inch whip; for ceiling installation by direct-mount spring clips or via mounting bracket in the octagon ceiling boxes.
  • The WPST and WLST tile mount kits may be ordered as factory-installed on the luminaire or order

Code Compliance

  • Thermally protected
  • cULus Certified to UL 1598 / C22.2 No. 250.0 suitable for wet locations with downlight; damp location with wall wash and hyperbolic with covered ceiling
  • IP66 rated when used with IP66 gasket kit accessory
  • Use IP66 gasket with nonconductive reflector for sauna or steam room applications up to 2000 lumens and 40°C.
  • Optional City of Chicago environmental air (CCEA) marking for plenum applications
  • FCC CFR Title 47 Part 15 Class B at 120VAC and Class A at 277VAC
  • Insulated ceiling (IC) rated up to 1,500 lumens (90 and 97CRI). All others are non-IC rated (insulation must be kept 3” from top and sides of housing).
  • Can be used for the State of California Title 24 high efficacy LED compliance under JA8, reference Modernized Appliance Efficiency Database System (MAEDBS) for 2016 JA8 High Efficacy Lighting
  • RoHS compliant
  • Photometric testing completed in accordance with IES LM-79
  •  LED life testing was completed in accordance with IES LM-80-08 and TM-21-11 standards

Warranty

Energy and Performance Data

D010 DRIVER ENERGY DATA

Series| 250 lumen| 500 lumen| 800 lumen| 1000 lumen| 1500 lumen| 2000 lumen
---|---|---|---|---|---|---
Input Voltage 120-277VAC| 120V| 277V| 120V| 277V| 120V| 277V| 120V| 277V| 120V| 277V| 120V| 277V
Input Current (A)| 0.029| 0.017| 0.061| 0.032| 0.085| 0.041| 0.084| 0.042| 0.135| 0.063| 0.189| 0.084
Input Power (W)| 3.45| 3.87| 7.33| 7.78| 10.15| 10.52| 10.04| 10.43| 16.17| 16.56| 22.58| 22.63
In-rush (A)| 2.1| 8.5| 3.7| 8.5| 3.6| 8.3| 3.6| 8.4| 2.3| 9.5| 2.1| 9.7
Inrush duration (µs)| 250| 131| 190| 136| 220| 135| 226| 136| 230| 125| 243| 132
THDi (%)| 7.21| 16.92| 7.82| 10.78| 5.57| 9.63| 7.78| 9.24| 4.75| 9.93| 8.03| 7.44
PF| ≥ 0.98| ≥ 0.9| ≥ 0.99| ≥ 0.93| ≥ 0.99| ≥ 0.95| ≥ 0.99| ≥ 0.95| ≥ 0.99| ≥ 0.94| ≥ 0.99| ≥ 0.96
Series| 2500 lumen| 3000 lumen| 3500 lumen| 4000 lumen
---|---|---|---|---
Input Voltage 120-277VAC| 120V| 277V| 120V| 277V| 120V| 277V| 120V| 277V
Input Current (A)| 0.276| 0.121| 0.276| 0.121| 0.333| 0.152| 0.404| 0.181
Input Power (W)| 32.98| 32.57| 32| 32.57| 39.83| 39.84| 48.38| 47.94
In-rush (A)| 2.5| 11.8| 3.6| 11.8| 3.1| 14.3| 3.1| 14.5
Inrush duration (µs)| 215| 111| 220| 111| 200| 94| 197| 95
THDi (%)| 9.86| 6.57| 5.57| 6.57| 4.25| 10.05| 5.02| 7.97
PF| ≥ 0.99| ≥ 0.97| ≥ 0.99| ≥ 0.99| ≥ 0.99| ≥ 0.94| ≥ 0.99| ≥ 0.95

Minimum starting temperature -30°C (-22°F)*  (Nominal input 120-277VAC & 100% of rated output power) Sound Rating: Class A standards

Notes:
Emergency Battery packs are rated for a minimum starting temperature of 0°C.

COLOR METRICS – TM-30-15 & CRI/CIE

  • 90 CRI Color Metric Summary – 3500K

  • 97 CRI Color Metric Summary – 2700K

  • 97 CRI Color Metric Summary – 3000K

  • Color values are based on haze reflector, other finishes and field results may vary

Photometric Data

Photometric Multipliers (Nominal Lumen Values)

250 Lumen| 500 Lumen| 800 Lumen| 1000 Lumen| 1500 Lumen| 2000 Lumen| 2500 Lumen| 3000 Lumen| 3500 Lumen| 4000 Lumen
---|---|---|---|---|---|---|---|---|---
0.224| 0.423| 0.569| 0.653| 1.00| 1.29| 1.62| 1.902| 1.74| 2.02

  • Multipliers for relative lumen values with other series models

CCT Multipliers – 90CRI

2400K 2700K 3000K 3500K 4000K 5000K
0.912 0.949 0.986 1 1.001 1.022
  • Multipliers for relative lumen values with other series color temperatures

CCT Multipliers – 97CRI

2700K 3000K 3500K 4000K 5000K
0.889 0.955 1 1.016 1.07
  • Multipliers for relative lumen values with other series color temperatures.

Connected Solutions

WaveLinx LITE – WLST Tilemount Sensor

  • Intuitive Android™ or Apple® iOS® app for basic system code compliant set up and configuration via Bluetooth
  • Up to 28 unique areas per project site (WaveLinx LITE Bluetooth network)
  • Up to 50 devices for an area, any one of 16 control zones, up to 6 occupancy sets, and custom lighting scenes
  • Automatic occupancy or vacancy, sensor sensitivity, daylight dimming, etc. configurable through the app
  • Refer to the WaveLinx system specifications for details

WaveLinx LITE WLST Tilemount Wiring Diagram

WaveLinx LITE Bluetooth Enabled System

WaveLinx PRO Wireless – WPST Tilemount Sensor

  • WaveLinx PRO Wireless functionality configures zones and customizes settings from one secure mobile app
  • Automatic code commissioning that meets the strictest codes
  • Fixtures and sensors integrate with Wireless Area Controllers, Wall Stations, and Control Devices
  • Stand-alone offices or Entire Building Network Installations

WaveLinx mobile app settings

WaveLinx PRO WPST Tilemount Wiring Diagram

WaveLinx CORE Building Management Integration

WaveLinx PRO Wireless Node – WPN

  • WaveLinx Wireless functionality configures zones and customizes settings from one secure mobile app
  • Automatic code commissioning that meets the strictest codes
  • Fixtures and sensors integrate with WaveLinx Area Controller, Wall Stations, and Control Devices
  •  Stand-alone offices or Entire Building Network Installations

WaveLinx mobile app settings

WaveLinx PRO Wireless Node (WPN) Wiring Diagram

WaveLinx CORE Building Management Integration

Multi-line Order Information
SAMPLE ORDER NUMBER: LDSSQ6C10D010TRIEM14
The invoice will indicate separate fixture components (housing, trim, module) and may ship from multiple CLS facilities in separate cartons.

|
---|---
Housing| Lumens (2)
LDSSQ6C =LED Square Downlight 6” Nominal Aperture

LDSSQ6CCP =LED Square Downlight 6” Nominal Aperture, Chicago Plenum

| 02 =250 lumens

05 =500 lumens

08 =800 lumens

10 =1000 lumens

15 =1500 lumens

| 20 =2000 lumens

25 =2500 lumens

30 =3000 lumens

35 = 3500 lumens

40 = 4000 lumens

| Specify from the  Driver column.   The information   below is  for reference only.|
---|---|---
Driver|
Remote driver & plug-in driver|
D010 = 0-10V Dimming, 1% to 100%, 120V-277V up to 4000 lumens (up to 3000 lumens for the remote driver)

1D010 =0-10V Dimming, 1% to 100%, 120V, 3500 to 4000 lumens for remote driver only

2D010 =0-10V Dimming, 1% to 100%, 277V, 3500 to 4000 lumens for remote driver only

3D010 =0-10V Dimming, 1% to 100%, 347V dedicated drivers for 800 to 4000 lumens; 250, and 500 use step down transformers

| __

250-4000 with 90 & 97 CRI

|
D010TR =0-10V (120-277V) or Line Voltage (120V) dimming, 5-100%, 250- 4000 lumens (up to 3000 lumens for remote driver)

1DE010 =0-10V or Line Voltage Dimming, 0% to 100%, 120V, 3500 to 4000 lumens for remote driver only

2DE010 =0-10V Dimming, 0% to 100%, 277V, 3500 to 4000 lumens for remote driver only

3D010TR =0-10V Dimming, 5% to 100%, 347V step down transformer 250-4,000

| __

250-4000 with 90 & 97 CRI

|
DE010 = 0-10V Dimming, 0% to 100%, 120V-277V 500-4000 lumens (up to 3000 lumens for remote driver)

1D010TR =0-10V Dimming, 5% to 100%, 120V, 3500 to 4000 lumens for remote driver only 2D010TR =0-10V Dimming, 5% to 100%, 277V, 3500 to 4000 lumens for remote driver only 3DE010 =0-10V Dimming, 0% to 100%, 347V step down transformer 500-4000 lumens

| __

500-4000 with 90 & 97 CRI

|
D5LT = Fifth Light® (DALI T6) Logarithmic Dimming, 0% to 100%, 120V-277V, 500-4000 lumens (up to 3000 lumens for remote driver)

1D5LT =Fifth Light® (DALI T6) Logarithmic Dimming, 0% to 100%, 120V, 3500 to 4000 lumens for remote driver only 2D5LT =Fifth Light® (DALI T6) Logarithmic Dimming, 0% to 100%, 277V, 3500 to 4000 lumens for remote driver only 3D5LT =Fifth Light® (DALI T6) Logarithmic Dimming, 0% to 100% 347V step down transformer, 500-4000 lumens

| __

500-4000 with 90 & 97 CRI

|
DMX = DMX/RDM Logarithmic Dimming, 0% to 100%, 120V-277V 800-4000 lumens (up to 3000 lumens for remote driver) (5)  1DMX = DMX/RDM Logarithmic Dimming, 0% to 100%, 120V, 3500 to 4000 lumens for remote driver only (5) 2DMX =DMX/RDM Logarithmic Dimming, 0% to 100%, 277V, 3500 to 4000 lumens for remote driver only (5)

3DMX =DMX/RDM Logarithmic Dimming, 0% to 100%, 347V step down transformer, 800-4000 (5)

| __

800-4000 with 90 & 97 CRI

|
DMXC5 = DMX/RDM Logarithmic Dimming, 0% to 100%, 120V-277V, 800-4000 lumens, RJ45 Connection (up to 3000 lumens for remote driver) (5)  1DMXC5 =DMX/RDM Logarithmic Dimming, 0% to 100%, 120V, 3500 to 4000 lumens for remote driver only, RJ45 Connection (5)  2DMXC5 =DMX/RDM Logarithmic Dimming, 0% to 100%, 277V, 3500 to 4000 lumens for remote driver only, RJ45 Connection (5) 3DMXC5 =DMX/RDM Logarithmic Dimming, 0% to 100%, 347V step down transformer, 800-4000, RJ45 Connection (5)| __

800-4000 with 90 & 97 CRI

|
DLE = Lutron Ecosystem dimming 1% to 100%, 120V-277V, 800-3500 lumens (up to 3000 lumens for the remote driver)

1DLE =Lutron Ecosystem dimming 1% to 100%, 120V, 3500 lumens for remote driver only 2DLE =Lutron Ecosystem dimming 1% to 100%, 277V, 3500 lumens for remote driver only 3DLE =Lutron Ecosystem dimming 1% to 100%, 347, step down transformer, 800-3500 lumens

| __

800-3500 with 90 & 97 CRI

|
DLV = Low voltage dimming driver (1-100%) for use with DLVP system 800-3000 lumens (6)| 800-4000 with 90 & 97 CRI (Not offered with plug-in driver)|
|
---|---
__

Driver Options

| __

Options (6) (19) (20) (21)

Blank =Integral driver

R =Remote driver (order remote driver separately)

PD =Plug in Driver (8)

| EM6 =6W Emergency Module with Remote Test Switch

WPN = WaveLinx PRO Wireless Node without sensor (24)

SAMPLE ORDER NUMBER: EU6C10259035

| | |
---|---|---|---
Power Module| Lumen Levels (2)| CRI (2)| Color
EU6C =6-inch Universal LED Module| 0208IC =250, 500, 800 lumens, IC Rated (For use with all drivers, min 500 lumens with DE010 and D5LT, min 800 lumens| 90 =90 CRI Minimum| 90 CRY

24 =2400K

27 =2700K

30 =3000K

35 =3500K

40 =4000K

50 =5000K

| 97 CRY
| with DLVP, Lutron, and DMX)| 97 =97 CRI Minimum| 27 =2700K
| 1025 = 1000, 1500, 2000, 2500 lumens| | 30 =3000K
| 1015IC =1000, 1500 lumens IC Rated| |
| 3040 =3000, 3500, 4000 lumens (For use with Lutron 3000-3500, DLVP 3000 lumens, DMX, D010, D010TR, D5LT and| |
| DE010 3000-4000)| |

SAMPLE ORDER NUMBER: 6LBM2H

| | |
---|---|---|---


Trim

| ****

Reflector

| ****

Flange

| ****

Finish

6LB =6” Reflector| CSSQ =Cast Shallow Square, Die Cast Aluminum| 1 =Self flanged (14)

2 =White painted self flanged

4 =Knife edge rimless use with die-cast only (15)

| MW =Matte White MB =Matte Black MMS =Matte Metallic Silver
PSSQMW1 =Non-Conductive Shallow (dead front), Self Flanged, White (23)

REQUIRED i f Remote Driver (R) is specified SAMPLE ORDER NUMBER: RC10010D010TREM7

|
---|---
Remote Drivers (6)| Lumens (2) (4)
RC100 =Remote 100ft| RC15 =Remote 15ft| 02 =250 lumens| 20 =2000 lumens
RC75 =Remote 75ft| RC5 =Remote 5ft| 05 =500 lumens| 25 =2500 lumens
RC50 =Remote 50ft| RC2 =Remote 2ft| 08 =800 lumens| 30 =3000 lumens
RC25 =Remote 25ft| | 10 =1000 lumens| 35 =3500 lumens
| | 15 =1500 lumens| 40 =4000 lumens


Driver
D010 = 0-10V Dimming, 1% to 100%, 120V-277V, 250-3,000 lumens

1D010 = 0-10V Dimming, 1% to 100%, 120V, 3500-4000 lumens

2D010 = 0-10V Dimming, 1% to 100%, 277V, 3500-4000 lumens

3D010 = 0-10V Dimming, 1% to 100%, 347V dedicated drivers for 800 to 4000 lumens; 250 and 500 lumens use step down transformer

D010TR = 0-10V (120-277V) or Line Voltage (120V) dimming, 5-100%, 250- 3000 lumens 1D010TR = 0-10V or Line Voltage Dimming, 5% to 100%, 120V, 3,500-4,000 lumens 2D010TR = 0-10V Dimming, 5% to 100%, 277V, 3,500-4,000 lumens

3D010TR = 0-10V Dimming, 5% to 100% 347V step down transformer, 250-4,000 lumens

DE010 = 0-10V Dimming, 0% to 100%, 120V-277V, 500-3,000 lumens

1DE010 = 0-10V Dimming, 0% to 100%, 120V, 3,500-4,000 lumens

2DE010 = 0-10V Dimming, 0% to 100%, 277V, 3,500-4,000 lumens

3DE010 = 0-10V Dimming, 0% to 100%0-10V Dimming 347V step down transformer, 500-4,000 lumens

D5LT = Fifth Light® (DALI T6) Logarithmic Dimming, 0% to 100%, 120V-277V, 500-3,000 lumens 1D5LT = Fifth Light® (DALI T6) Logarithmic Dimming, 0% to 100%, 120V, 3,500-4,000 lumens 2D5LT =Fifth Light® (DALI T6) Logarithmic Dimming, 0% to 100%, 277V, 3,500-4,000 lumens

3D5LT =Fifth Light® (DALI T6) Logarithmic Dimming, 0% to 100% 347V step down transformer, 500-4,000 lumens

DMX = DMX/RDM Logarithmic Dimming, 0% to 100%, 120V-277V, 800-3,000 lumens (5)

1DMX =DMX/RDM Logarithmic Dimming, 0% to 100%, 120V, 3,500-4,000 (5)

2DMX =DMX/RDM Logarithmic Dimming, 0% to 100%, 277V, 3,500-4,000 (5)

3DMX =DMX/RDM Logarithmic Dimming, 0% to 100%, 347V step down transformer, 800-4,000 (5)

DMXC5 = DMX/RDM Logarithmic Dimming, 0% to 100%, 120V-277V up to 800-3,000 lumens, RJ45 Connection (5)

1DMXC5 =DMX/RDM Logarithmic Dimming, 0% to 100%, 120V, 3,500-4,000 lumens, RJ45 Connection (5)

2DMXC5 =DMX/RDM Logarithmic Dimming, 0% to 100%, 277V, 3,500-4,000 lumens, RJ45 Connection (5)

3DMXCF =DMX/RDM Logarithmic Dimming, 0% to 100%, 347V step down transformer, 800-4,000 lumens, RJ45 Connection (5)

DLE = Lutron Ecosystem dimming 1% to 100%, 120V-277V, 800-3,000 lumens

1DLE =Lutron Ecosystem dimming 1% to 100%, 120V, 3,500 lumens

2DLE =Lutron Ecosystem dimming 1% to 100%, 277V, 3,500 lumens

3DLE =Lutron Ecosystem dimming 1% to 100%, 347V, step down transformer, 800-3,500 lumens

DLV = Low voltage dimming driver (1-100%) for use with DLVP system, 800-3000 lumens (6)
|
---|---


Options **(6) (19) (20) (21)**

| ****

Controls

EMBOD =Bodine® Emergency Module with Remote Test Switch EMBOD6ST =Bodine® 6W Self Test Emergency Module with Remote Test Switch EM7 =7W Emergency Module with Remote Test Switch

EM14 =14W Emergency Module with Remote Test Switch

| EMBOD7ST =Bodine® Self Test Emergency Module

EMV7 =7W Low Voltage Emergency Module with Remote Test Switch (7) EMV14 =14W Low Voltage Emergency Module with Remote Test Switch (7) ETRD =Emergency transfer device (22)

| WPST =Factory installed Wavelinx (includes a control module, sensor, cable, tile mount and ceiling mount sensor) (11) (13) WLST =Factory installed WaveLinx LITE Sensor Kit (11) (12)

WPN = WaveLinx PRO Wireless Node without sensor (24)


Accessories ( Sold separately ) (16)
LGSKT6SQIP66 =IP66 Gasket Kit| RPMSQ6MW =Rimless Millwork Ring, Matte White (17)| Bar Hangers| Connected Lighting Systems (6) **(11)
|
RPMSQ6MB =Rimless Millwork Ring, Matte Black (17)| HB26 =C-channel Bar Hanger, 26” Long, Pair| WPST = Field installed WaveLinx sensor Kit (13)
PRSQ6 = Rimless Plaster Ring (17)| RKMSQ6MW =Knife Edge Millwork Ring, Matte White (18)| HB50 =C-channel Bar Hanger, 50” Long, Pair| WLST = Field installed WaveLinx LITE Sensor Kit (12)
RKPSQ6 = Knife Edge plaster Ring (18)| RKMSW6MB =Knife Edge Millwork Ring, Matte Black (18)| RMB22** =Wood Joist Bar Hanger, 22” Long, Pair|

Notes

  1. Nominal Lumens will vary depending on the selected color, CRI, driver, and reflector finish. Reference Multiplier tables.
  2. IC rated up to 3000 lumens for 90 & 97 CRI
  3. DMX fixtures default to full-on upon loss of DMX signal.
  4. Not available with Chicago Plenum.
  5. ULus listed only
  6. Not available with DLVP
  7. Refer to system specifications for additional information, features, and benefits. Order either factory factory-installed option or an accessory. Use with 0-10V driver.
  8. WLST = WaveLinx LITE tile mount sensor kit for daylight dimming, PIR motion sensing, use with D010 only (Refer to WaveLinx LITE system specifications)
  9.  WPST = WaveLinx wireless sensor kit for daylight dimming, PIR motion sensing, and optional RLTS – Real Time Location Services, use with 0-10V only.
  10. The flange is the same finish as the reflector
  11. Requires knife edge ring
  12. Accessories sold separately will be separately analyzed under domestic preference.
  13. Order trim with flange type 3.
  14. Order die-cast trim with flange type 4
  15.  For the remote driver order an emergency module with the remote driver.
  16. 120V-277V
  17.  Non-IC
  18. Used to bypass local control during outage. Must be used in conjunction with UL 1008 device (provided by others)
  19. Limited to 2000 lumens
  20. WPN = WaveLinx PRO wireless node provides luminaire-level control with scene and zone configuration without an integrated sensor; Connects wirelessly with daylight dimming sensor and PIR motion sensor if desired. Use with 0-10V driver only.

Dimensional and Mounting Details

CONTACT

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Coopers OF STORTFORD User Manuals

Related Manuals