MASTERPLUG EVCM22135-MP-PKS Charger User Guide

June 15, 2024
masterplug

MASTERPLUG EVCM22135-MP-PKS Charger

MASTERPLUG-EVCM22135-MP-PKS-Charger-product

Mode 2 EV Charger
This Masterplug Mode 2 charger is intended for use with electric and hybrid vehicles. Please read and use these safety instructions. Please retain instructions for reference.

Safety Instructions

  • Always inspect before use, do not use if the Electric Vehicle Supply Equipment (EVSE) plug, or cable is damaged.
  • Do not use an extension lead or adaptor.
  • Connect the charging cable to a correctly functioning and suitable socket outlet.
  • Protect the plug and cable from moisture.
  • The user is responsible for any personal injury or vehicle or property damage arising from inappropriate use.
  • Operating Instructions & Indicator Status

Follow the instructions on the charger screen

  1. Insert a 3-pin plug into a wall socket (and switch it on) – The charger starts self-test mode, and the Masterplug logo will appear on the screen.
  2. After a couple of seconds, the LED will flash Blue, ready to connect, if it is red, check the fault guide.
  3. Connect to EV – the charger will then start communication with the car, indicated by a Yellow LED.
  4. Charging – Green indicator streams from top to bottom. Once charged indicator will turn solid Green.
  5. To end charging disconnect (turn off) from the wall socket and remove the charger from EV.MASTERPLUG-EVCM22135-MP-PKS-Charger-fig-1

Fault Guide & Trouble Shooting

The charger includes many safety features to protect your electric vehicle, a fault is indicated by illumination of the Red indicator.

MASTERPLUG-EVCM22135-MP-PKS-Charger-fig-2

  • To reset and clear the fault follow the instructions.
  • Unplug the charging cable from the vehicle.
  • Unplug (or turn off) the charging cable from the wall socket.
  • Keep unplugged for 30 seconds.
  • Repeat the connection process.
  • If the faults are not reset, the charging cable may be faulty. Please contact the retailer, or Masterplug via our helpdesk support team – 03300 249 279 / technical.support@masterplug.com

Technical Data

  • Rated CurrenWoltage/Frequency: 1 0A/230V/50Hz
  • Output: 2.3kW Max
  • Rated Residual Operating Current: Ian: 30mA, 6mA DC
  • Operating Temperature: -25°C to +40°C
  • IP Rating: IP66(Control Box)
  • Standards: EN 62752; EN 61851-1

Care
Masterplug recommend the use of a soft dry or slightly damp cloth periodically to clean the cable and charger body. Do not use cleaning agents.

Batch Code Explanation
Manufacturing date code, year of manufacture (yy) and week of manufacture (Wxx)

Environmental Protection
This symbol is known as the”Crossed-outWheelie Bin Symbol”.When this symbol is marked on a product or battery, it means that it should not be disposed of with your general household waste. Some chemicals contained within electrical/electronic products or batteries can be harmful to health and the environment. Only dispose of electrical/electronic battery items in separate collection schemes, which cater for the recovery and recycling of materials contained within. Your co-operation is vital to ensure the success of these schemes and for the protection of the environment.

Address/Helpline
Luceco PLC Stafford Park 1 Telford TF3 3BD ENGLAND
(EU) Luceco SE C/ Bobinadora 1-5 08302 Matar6 SPAIN
If you have further technical assistance you can get in touch with our Technical Helpline at: