trulifi 912500103432 6002.1 Access Point Instruction Manual
- June 4, 2024
- Trulifi
Table of Contents
Trulifi 6002
6002.1 Access Point
912500103432 6002.1 Access Point
12NC order code | System Power (W) | Power factor | Voltage (V) | Rel.humidity (%) |
---|---|---|---|---|
Trulifi Controller Unit EU 6800.00 | 9.13E+11 | |||
Trulifi Controller Unit NA 6800.01 | 9.13E+11 | |||
Trulifi Controller Unit Application 6800.20 | 9.13E+11 | |||
Trulifi License 6800 NMC * | 9.13E+11 | |||
Trulifi Access Point 6002.1 | 9.13E+11 | 3 | 0.9 | 100-40 VAC |
Trulifi Transceiver 6002.1 | 9.13E+11 | 7(AccessPoint) | 24 V D (Access Point) | |
Trulifi USB Key 6002.1 | 9.13E+11 | 3.5 | 5 V DC (USB) | |
Trulifi USB Key 6002.22 | 9.13E+11 | 3.5 | 5 V DC (USB) |
* Trulifi License 6800 NMC license to be obtained from your local Signify representative
Access Point
Dimensions in mm/in
Transkei ver
USB Key
Operational distance LiFi connectivity connectivity spread
Trulifi 6800 Controller Unit supports up to 16 Access Points. Refer to Trulifi
6800 Controller User Guide
Ceiling holder (sold separately)
United States of America
Note with regards to installation of the Truli 6002 Access Point (in short:
‘Access Point’)
and the Truli 6002 Transceiver (in short: ‘Transceiver’) in the United States
of America:
- The Access Point and Transceiver pass the acceptance criteria for the flame test as defined in UL standard 2043, 4th edition. Compliance with UL2043 implies that the Acces Point and Transceiver can be installed in building plenums in most US regions. Please refer to your local installer for installation options in accordance with local regulations.
- The Transceiver RJ12 cable (7 mtr, white) and POF cable (10 mtr) are both plenum-rated and can therefore be installed without the need for additional metal conduits.
- **** The LiFi system shall be installed by a qualified electrician and wired in accordance with the latest IEEE electrical regulations or national requirements.
- Access points and Controller shall be disconnected from mains power during installation and wiring.
- To avoid damaging the POF cable, a bend radius of at least 25 mm shall be observed during installation
- For Canada only: Canada ICES-003 (B) / NMB-003 (B)
ATTENTION OBSERVE PRECAUTIONS FOR HANDLING ELECTROSTATIC SENSITIVE DEVICES
Trulifi 6002.1 system – Installation instructions
4422-947-86394_460_C
Printed in The Netherlands
Data subject to change without notice
Keep for future reference: www.signify.com
© 2022 Signify Holding. All rights reserved. The information provided herein
is subject to change, without notice. Signify does not give any representation
or warranty as to the accuracy or completeness of the information included
herein and shall not be liable for any action in reliance thereon. The
information presented in this document is not intended as any commercial offer
and does not form part of any quotation or contract unless otherwise agreed by
Signify.
All trademarks are owned by Signify Holding or their respective owners.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>