trulifi 912500102095 6002.2 Access Point Instruction Manual

June 4, 2024
Trulifi

trulifi logo 912500102095 6002.2 Access Point
Instruction Manualtrulifi 912500102095 6002.2 Access
Point

912500102095 6002.2 Access Point

| 12NC order code| System Power (W)| Power factor| Voltage (V)| Rel. humidity (%)
---|---|---|---|---|---
Trulifi Controller Unit EU 6002.0| 9.125E+11| | | |
Trulifi Controller Unit NA 6002.0| 9.125E+11| | | |
Trulifi Controller Unit EU 6800.00| 9.125E+11| | | |
Trulifi Controller Unit NA 6800.01| 9.125E+11| | | |
Trulifi Controller Unit Application 6800.20| 9.125E+11| | | |
Trulifi License 6800 ROAMING | 9.125E+11| | | |
Trulifi License 6800 NMC
| 9.125E+11| | | |
Trulifi Access Point 6002.2| 9.125E+11| 4.2 (idle) / 38 (full load)| 0.3 (idle) / 0.5 (full load)| 100-240 V AC| 20 – 90
Trulifi transceiver 6002.1| 9.125E+11| 4.6 (Access Point)| | 24 V DC (Access Point)
Truly USB Key 6002.1| 9.125E+11| 3.5| | 5 V DC (USB)|
Truly USB Key 6002.22| 9.125E+11| 3.5| | 5 V DC (USB)|
Trulifi POF cable EU 10 m| 9.125E+11| | | |
Trulifi POF cable NA 10 m| 9.125E+11| | | |

  • For Trulifi License 6800 ROAMING and Trulifi License 6800 NMC license key please contact your local Signify representative

Access Point

trulifi 912500102095 6002.2 Access Point - Figure 1trulifi 912500102095 6002.2 Access Point - Figure
2trulifi 912500102095 6002.2 Access Point - Figure
3

United States of America
Note with regards to the installation of the Truli 6002 Access Point (in short: ‘Access Point’) and the Truli 6002 Transceiver (in short: ‘Transceiver’) in the United States of America:

  • The Access Point and Transceiver pass the acceptance criteria for the flame test as defined in UL standard 2043, 4th edition. Compliance with UL2043 implies that the Access Point and Transceiver can be installed in building plenums in most US regions. Please refer to your local installer for installation options in accordance with local regulations.
  • The Transceiver RJ12 cable (7 m/23 ft, white) and POF cable (10 m/33 ft) are both plenum-rated and can therefore be installed without the need for additional metal conduits.

The LiFi system shall be installed by a qualied electrician and wired in accordance with the latest IEEE electrical regulations or national requirements.

  • Access points and Controller shall be disconnected from mains power during installation and wiring.
  • To avoid damaging the POF cable, a bend radius of at least 25 mm/1 in shall be observed during installation
  • For Canada only: Canada ICES-003 (B) / NMB-003 (B)

ATTENTION
OBSERVE PRECAUTIONS FOR HANDLING  ELECTROSTATIC SENSITIVE DEVICES

trulifi 912500102095 6002.2 Access Point - Figure 4trulifi 912500102095 6002.2 Access Point - Figure
5

Trulifi 6002.2 system – Installation instructions
4422 947 86223_460/C
Printed in The Netherlands
Data subject to change without notice
Keep for future reference: www.signify.com

trulifi logo

© 2022 Signify Holding. All rights reserved. The information provided herein is subject to change, without notice. Signify does not give any representation or warranty as to the accuracy or completeness of the information included herein and shall not be liable for any action in reliance thereon. The information presented in this document is not intended as any commercial offer and does not form part of any quotation or contract unless otherwise agreed by Signify.
All trademarks are owned by Signify Holding or their respective owners.