VATION LIGHTING 12 Pack 6 Inch 5CCT Ultra Thin Dimmable LED Recessed Light User Manual

June 15, 2024
VATION LIGHTING

VATION LIGHTING 12 Pack 6 Inch 5CCT Ultra Thin Dimmable LED Recessed

Light

VATION-LIGHTING-12-Pack-6-Inch-5CCT-Ultra-Thin-Dimmable-LED-Recessed-Light-
product

Product Information

Specifications

  • Model No: VDL4-1050D, VDL6-1250D, VDL6-1550D-FR
  • AC Input Voltage: 120V/60Hz
  • Light Output: 850lm, 1200lm, 1400lm
  • Watts: 10W, 12W, 15W
  • Lumens Per Watt Efficacy: 85, 100, 93
  • CRI: 80
  • Beam Angle:
  • Color Temperature: 2700/3000/3500/4000/5000K
  • Warranty: 5 Years

Product Usage Instructions

Installation Steps

Step 1: Turning off the Power

  1. Turn the power OFF from the electrical panel before starting installation.

Step 2: Mounting the Fixture

  1. Locate a suitable position to place the fixture and open by the cut-hole dimensions (refer to Hole Cut Table for appropriate size).
  2. Run electrical wire from the switch (power supply) through the mounting hole – use NMD90 Romex or BX cable.

Step 3: Connecting the Electrical Supply Cable

  1. Open the hardwire box swing cover and remove the appropriate knockout(s).
  2. Insert the electrical supply cable through the knockout and secure it with a cable connector (sold separately).
  3. Using wire nuts, connect the green ground wire of the cable to the green wire on the box. Connect the white wire of the cable to the white wire of the box. Connect the black wire of the cable to the black wire of the box.
  4. Place all wiring and connections back into the box and close the cover.

Step 4: Inserting the Hardwire Box
Insert the hardwire box through the mounting hole. For new construction applications, the hardwire box should be firmly secured to studs, joists, or similar fixed structural units. For remodel applications, the hardwire box does not need to be firmly secured after the mounting plates, studs, joists, or structural units have been concealed.

Step 5: Connecting the Fixture

  1. Connect the fixture to the hardwire box by inserting and twisting the male/female connectors.

Important Precautions

  • To avoid early failure due to improper installation, shut off power at the circuit breaker or fuse panel before removing the old fixture or installing the new one.
  • This lamp is suitable for use in damp locations.
  • Use only on 120-volt AC, 60Hz circuits.

FAQ

Q: How do I contact Customer Support?
In the event of any problems with the operation of any of our products, you can contact our Customer Support directly through an Amazon order, or you can send your inquiry to our official Customer Support:

Q: How do I confirm if the fixture is working properly?
Once assembly is complete, turn on the power to confirm the fixture is working properly.

Q: Can I use a dimmer with this product?
Yes, this product is compatible with dimmers from the following brands and models:

  • Lutron: SKYLARK, CONTOUR, CASETA, DIVA, TOGGLER, ARIADNI, MAESTRO, ILLUMATECH, SURESLIDE, SMART DIMMER, HARMONY ROCKER, TOGGLE
  • LEVITON: LECL-153P, CTCL-150H, LGCL-153PLH, CTCL-153P, SCL-153P, S-600P, PD-6WCL, PD-5NE, PD-10NXD, DVCL-153P, TGCL-153P, AYCL-153P, MACL-153M
  • EATON: IPL06, 6672, 6674, AAL06
  • PASS & SEYMOUR: DCL453PTCCCV6
  • GE: 10464, 18027

Q: Where can I get assistance?
If you need further assistance, please consult the dealer or an experienced radio/TV technician for help. You can also reach out to our official Customer Support.

INSTALLATION STEPS

  1. Turn the power OFF from the electrical panel before starting installation.

  2. Locate a suitable position to plate the fixture and open it by the cut-hole dimensions (refer to Hole CutTable for appropriate size) .

  3. Run electrical wire from the switch (power supply) through the mounting hole-use NMD90 Romex or BX cable.

  4. Open the hardwire box swing cover and remove the appropriate knockout(s)

  5. Insert the electrical supply cable through the knockout and secure it with a cable connector (sold separately).

  6. Using wire nuts, connect the green ground wire of the cable to the green wire on the box. Connect the white wire of the cable to the white wire of the box. Connect the black wire of the cable to the black wire of the box. (Fig.2)

  7. Place all wiring and connections back into the box and close the cover.

Insert the hardwire box through the mounting hole.

  • New construction applications: Hardwire box shall be firmly secured to studs, joists, or similar fixed structural units.
  • Remodel applications: Do not require the hardwire box to be fully secured after the mounting plates, studs, joists, or structural units have been concealed.

Connect the fixture to the hardwire box by inserting and twisting the male/female connectors.

  1. Push spring-loaded clips on the fixture upwards and insert the fixture base into the mounting hole. Release the clips and the fixture will be pulled flush to the ceiling.
  2. Once assembly is complete, turn on the power to confirm the fixture is working properly

CAUTION

To avoid early failure due to improper installation, please observe the following precautions: Shut off power at the circuit breaker or fuse panel before removing the old fixture or installing the new one. This lamp is suitable for use in damp locations. Use only on 120-volt AC, 60Hz circuits.

FCC WARNING

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:

  1. This device may not cause harmful interference, and
  2. This device must accept any interference received, including interference that may cause undesired operation.

Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

NOTE:
This equipment has been tested and found to comply with the limits for a Class B digital device, under Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used per the instructions, may cause harmful interference to radio communications.

However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and the receiver.
  • Connect the equipment to an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer-experienced radio/ TV technician for help.

SPECIFICATIONS

VATION-LIGHTING-12-Pack-6-Inch-5CCT-Ultra-Thin-Dimmable-LED-Recessed-Light-
fig- \(6\)

Hole Cut Size

  • 3 inch round Φ3″(78mm)
  • 4 inch round Φ4-1/4″(108mm)
  • 4-inch square Φ4-1/4″(108mm) *Φ4-1/4″(108mm)
  • 6 inch round Φ6-1/4″(158mm)
  • 6-inch square Φ6-1/4″(158mm) *Φ6-1/4″(158mm)
  • 8 inch round Φ8-1/4″(210mm)

Dimmer Compatible List

BRAND SERIES MODEL LOAD
LECL-153P 150W
CTCL-150H 150W
SKYLARK LGCL-153PLH 150W
CONTOUR
CTCL-153P 150W
LUTRON SCL-153P 150W
S-600P 600W
PD-6WCL 150W
CASETA PD-5NE 150W
PD-10NXD 250W
DIVA DVCL-153P 150W
TOGGLER TGCL-153P 150W
LUTRON ARIADNI AYCL-153P 150W
MAESTRO MACL-153M 600W
ILLUMATECH IPL06

6672

6674

AAL06 DCL453PTCCCV6 10464

18027

| 150W
LEVITON| | 150W
| SURESLIDE|
| | 150W
EATON| SMART DIMMER| 300W
PASS &| |

150W

SEYMOUR| HARMONY
| ROCKER| 150W
GE| |
| TOGGLE| 150W

In the event of any problems with the operation of any of our products, you can contact our Customer Support directly through an Amazon order, or you can send your enquiry to our official Customer Support:

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals