Nicwell DE-TENS-A Tens Unit Muscle Stimulator Machine User Guide

June 15, 2024
Nicwell

Nicwell DE-TENS-A Tens Unit Muscle Stimulator Machine User Guide

QUICK START GUIDE

  1. Connect electrode pads to respective electrode  wire, ensure no bare metal of the pins is exposed.

  2. Insert one electrode wire into each desired channel.
    Installation

  3. Remove electrode pads from plastic film and place on skin. Ensure the applicable skin is clean and dry. Pads should be replaced ‘when they lose their ad-hessite quality or after using 10-15 times or you sense a change in stimulation sensation. If you’re in doubt about the integrity of the pads, replace with new electrode pads.

  4. Power on by pressing “ ” button
    Installation

  5. Press the [ M ] button to select treat mode ( TENS – EMS – MASS )
    Installation

  6. Press the ” ” button to select current treat
    Installation
    program.
    TENS: 9 programs (P1-P9)
    EMS : 8 programs (P1-P8)
    MASSAGE : 5 programs (P1-P5)

  7. Pressthe “ ” button to select treatment minutes. (10-20-30-40-50-60-70-80-90 change in cycle) .
    Installation

  8. To adjust the intensity level, press” to increase, or” “to decrease until the desired intensity level you got. (1-40 levels) When output intensity decreased 10 00, the treatment will end.

Safety Lock :

The safety Lock activate automatically when no button pressed for 20 seconds while in treating mode. The indicator ” will display . This is a safety feature to prevent accidental touches.

Unlock: Press*  “button to unlock.

Pause Treatment and Stop Treatment :
Atthe treating mode, pressthe” ” to pause, the ” ” will display on the screen.
At the treating mode, press “ button to stop treatment. “to stop treatment and select At the treating mode, if you don’t like the current program, please press ” other program.

Electrode detection function:

When the electrode wire is not properly connected to the machine, the electrode wire is not properly connected to the electrode pad or the electrode pad is not completely attached to the skin, the instrument determines that the circuit is short-circuited, the electric current level will be reset to 0 mA and shows ER on  the display. Please recheck the wire and pads are properly connected, or replace some new pads and stick on the skin.

Charging :

The ” signals when the battery i low. Turn off the device and charge the battery. When s charging, the indicator light will be red. When charging is completed, the indicator ight will be green. 5V /1A Wall Charger Recommended (wall charger not include in this product).

Automatic shut off :

The device turns off automatically when the treatment minutes has elapsed or when no button is pressed for 60 seconds.

Memory :

The most recently set is stored. The last treatment program you used and the therapy time you set will appear on the display, when you turn on the device.