Test Instrument TISUSB1 USB Socket Tester User Guide
- June 15, 2024
- Test Instrument
Table of Contents
Test Instrument TISUSB1 USB Socket Tester User Guide
TISUSBI1 – USB Tester
Introduction:
The TISUSBI tests and inspects USB chargers / ports, portable power sources,
load of connected USB appliances / devices.
The TISUSBI tests the output voltage , current, energy, capacity, circuit
equivalent resistance.
Safety Regulations
TISUSB Internal load test will stop if the voltage exceeds 13V
TISUSBI Overheat protection — If the internal load functioning temperature fossil exceeds the “HOT” warning message will be displayed. Load measurements will then stop, until the internal temperature drops below
Input Voltage Verification
Input USB male contactor to USB charger / port or power source Check voltage displayed is within the devices manufactures specifications.
If the voltage exceeds 24V the “OL” warning message will be displayed, please disconnect the tester.
The “LO” warning symbol will be displayed if the voltage is less than 4V.
INPUT VOLTAGE MUST NOT EXCEED 25V.
Electronic Load Testing
After confirming the output voltage is correct, users can then test the load of USB powered electronic devices & device charging loads by inserting the USB cable into the output socket. The load & output voltage will then be displayed automatically.
Operational Instructions
Short press the “Mode” button to switch between / view different parameters.
Long press the “Mode” button to reset test parameters / clear data.
Short press the “Load” button to start & change load test parameter. Test
Sequence 5.0.50A —1.00A—2.00A—3.00A
Specifications
F unction | Range | Resolution | Tolerance |
---|---|---|---|
Current Measurements | 0.05A – 3.00A | 0.01A | +(1%+2) |
Voltage Measurements | 4.00V – 24.00V | 0.01v | +(1%+2) |
Capacity | 0mAh — 99999mAh | 1mAh | |
Energy | OWh — 1000Wh | 1Wh | |
Circuit equivalent resistance Measurement | 1Q – 480Q | 1Q | |
Electronic Load | 0.50A,1.00A,2.00A,3.00A | +0.03A, £0.04A, £0.05A, £0.06A | |
Maximum Timing | 99Hours, 59 Minutes, 59 Seconds | 1 | 1 Second |
WARRANTY
NEW INSTRUMENTS HAVE A WARRANTY PERIOD OF: 1 YEAR FROM THE DATE OF PURCHASE
BY THE USER (A copy of the original purchase invoice may be requested to
validate the purchase date). This warranty period includes parts and labour
only.
Any damage to either the case, input cable or any unauthorized repair /
adjustment will void the warranty.
Test Instrument Solutions LTD Units 12/14
Luddite Way Business Park
Rawfolds Way Cleckheaton BD19 5DQ
TEL : 01274 752407
Email : support@tis-tic.co.uk
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>