ATEC IOT TWZT-S001D-P Pole Zigbee Module User Manual

June 15, 2024
ATEC IOT

ATEC IOT TWZT-S001D-P Pole Zigbee Module

ATEC-IOT-TWZT-S001D-P-Pole-Zigbee-Module-PRODUCT

PRODUCT SPECIFICATION

Model Part Number Customer P/N

Pole Zigbee Module

| ****

TWZT-S001D-P

| ****

DESIGNED CHECKED APPROVED
2023.01.26 2023.01.26 2023.01.26
J.B.KIM J.S.YEON I.U.KIM

SPECIFICATION

MODEL| TWZT-S001D-P| REV. No.| Rev. 0.1
REG. DATE| 2023.04.01| PAGE| 31
REV. DATE| –| –| –

Revision History

Revision Date Contents of Revision Change Remark
0.0 2023.04.01 Initial Release J.B. Kim

Application

This Specification is applied to ATEC IoT Pole Zigbee Module(TWZT-S001D-P). TWZT-S001D-P is a Common Zigbee Module solution for IEEE 802.15.4(6LoWPAN) applications. The robust network with PA(Power Amplifier) and diverse interface(SPI, UART, I2C) make it possible to be used as various kinds of applications. In particular, it is suitable for Gen2 Gateway and RTLS Anchor. TWZT-S001D-P is composed of RF IC and necessary external components including the Dipole Ant.

Quality

Quality should meet each condition which mentioned on this specification. However, the items which are not mentioned on this specification follow the inspection agreements and standards that are agreed upon with both companies.

Appearance and Characteristics

Appearance
Appearance should not be contaminated by harmful materials and should not have cracks, etc. Mechanical dimensions should meet the contents of clause 8.

Characteristic
Electrical Characteristics should meet the contents of clause 7.

Overall Service Scenario

ATEC-IOT-TWZT-S001D-P-Pole-Zigbee-Module-fig-1

General Features

Description

Item Description
Size 42.3 x 28.0 x 9.8 (mm)
Weight Typ. 6g

Memory

| Internal Flash : 512KB SRAM : 32KB

Power

|

Operating Voltage : Typ. 3.3V (2.3V~3.6V)

RF

| Tx Power| Max.10dBm
Data Rate| 250kbps
Antenna| Dipole Antenna

Network

| 20pin Interface| UART for FW Downloading SPI for Communication
Wireless| 2.4GHz IEEE802.15.4 compliant RF Transceiver Range Extender (PA/LNA)
Security| Robust wireless network (ATEC IoT own protocol)
Protocol| Compatible with ATEC IoT protocol communication devices
Comm. Range| Max. 30m (under LoS) (1)

  1. LoS (Line of Sight) : Without any sort of an obstacle between a gateway and end devices

Absolute Maximum Rating

Environmental Conditions
The normal operating environmental conditions are those as below. In such conditions, ESL must conform with the present specification. The conformity to such requirements must be certified by the manufacturer.

Parameter Condition Min. Typ. Max. Unit

Operating Environment

| Temperature| -20| –| 85| ℃
Humidity| –| 35| 80| %RH

Storage Environment

| Temperature| -30| –| 85| ℃
Humidity| –| 35| 80| %RH

[Notice]

  • TWZT-S001D-P is designed to be used indoors/Ceiling. It does not guarantee outdoor conditions.

Electrical Conditions
The operating electrical conditions are those as below. In such conditions, the ESL must conform with the present specification. All devices can be damaged or non-operated over the specification as below. The conformity to such requirements must be certified by the manufacturer.

Parameter Condition Min Typ. Max Unit
Supply Voltage DC Power Supply 2.3 3.3 3.6 V

Power Consumption

| @ 3.0~3.3V (Active Tx)| –| –| 200| mA
@ 3.0~3.3V(Active Rx)| –| –| 15| mA

ESD Protection

| HBM(150pF/330Ω) (1)

Air Condition @Soft Fail

|

-8

|

|

+8

|

kV

[Notice]

  1. TWZT-S001D-P is ESD ESD-sensitive device. Precaution should be used when handling the device to prevent permanent damage.

Electrical Specification

IEEE802.15.4
The TWZT-S001D-P supports IEEE802.15.4.

General Specification

  • Standard : Only IEEE802.15.4 PHY
  • Frequency : 2405 ~ 2480MHz
  • Channel : 16CH. (5MHz Spacing)
  • Modulation : DSSS/O-QPSK
  • Max. Data Rate: 250Kbps

Electrical Specification

  • Channel power depends on each country’s regulations (EX. KC, etc)
  • The electrical specification which is shown below is ATEC IoT internal specification.
  • All values depend on the surrounding environment and the current statement of an access point

RF Performance

Parameter| Condition| Min| Typ| Max| Unit
Output Power| | –| –| 10| dBm
Receiver Sensitivity| PER=1% (Required -85dBm)| -85| –| –| dBm
Maximum Input Level| PER=1% (Required -20dBm)| –| –| -20| dBm
Frequency Tolerance| Required Max. ±75kHz| -75| –| 75| kHz
Error Vector Magnitude| Required Max. 35%| –| –| 35| %

Antenna Performance

Antenna
The TWZT-S001D-P supports IEEE802.15.4.

Radiation Pattern and Gain

ATEC-IOT-TWZT-S001D-P-Pole-Zigbee-Module-fig-2

[Notice]

  • This data is measured when TWZT-S001D-P is connected to the 4th Slot of Gen2 Gateway Board. Gen2 Gateway has 7 slots for diverse modules. The 4th Slot is the middle slot of whole 7 slots of it.
Antenna Performance

Gen2 Gateway Slot Information

ATEC-IOT-TWZT-S001D-P-Pole-Zigbee-Module-fig-3

Interface Information

# Name I/O Description
1 GND G Common ground
2 SPI_CS O Enable input for SPI interface
3 SPI_MISO I SPI data input
4 WAKE UP O wake up signal
5 UART_TX I NC
6 UART_RX O NC
7 VDD P 3.3V external DC supply
8 VDD P 3.3V external DC supply
9 GND G Common ground
10 GND G Common ground
11 GND G Common ground
12 NC NC
13 TEST_PIN O Firmware Download Enable Pin
14 GND G Common ground
15 RESET I Reset input/output(active low)
16 IRQ I Interrupt output to the host processor
17 GND G Common ground
18 SPI_CLK I SPI interface clock
19 SPI_MOSI O SPI data input
20 GND G Common ground

Mechanical Information

Mechanical Dimension

Size 42.3 x 28.0 x 9.8 mm
Weight Typ. 6g

ATEC-IOT-TWZT-S001D-P-Pole-Zigbee-Module-fig-5

Assembly

ATEC-IOT-TWZT-S001D-P-Pole-Zigbee-Module-fig-6

User Quick Manual

Pole Zigbee Module User Manual

Pole Zigbee Module is suitable for Gen2 Gateway. 3 Slots of Gen2 Gateway can be used for Zigbee. To fulfill the ESL System, at least 3 Pole Zigbee Modules should be inserted to the Gateway. Likewise, this picture, when you insert modules, be careful with the directions. Modules will not be able to be put in when the inserting direction is opposite.

LED Alarming
When Modules are working abnormally, three LEDs(Power, Status, Ethernet) would blink to alarm the unusual state.ATEC-IOT-TWZT-S001D-P-Pole-Zigbee-
Module-fig-8

  • The abnormal phenomenon could happen when you force pull out the modules or module malfunctions.

Disclaimers

  • ATEC IoT is not responsible for any damages caused by any accidents or operational environments exceeding the absolute maximum ratings.
  • Consultation with ATEC IoT is recommended for unassured environments or operations to avoid any possible malfunctions or damages to the products or risk to life or health.
  • Any unauthorized, without prior written consent from ATEC IoT, disassembly is prohibited if purposed for reverse-engineering. All defective devices must be reported to ATEC IoT and not to be disassembled or analyzed.
  • The product information can be modified and upgraded without prior notice.
    • Rule Part 15.19(a)(3): This device complies with part 15 of the FCC Rules.

Operation is subject to the following two conditions:

  1. This device may not cause harmful interference, and
  2. this device must accept any interference received, including interference that may cause undesired operation.

Rule Part 15.21: The user’s manual or instruction manual for an intentional or unintentional radiator shall caution the user that changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

FCC STATEMENT

Note: This equipment has been tested and found to comply with the limits for a Class B digital

NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, according to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used under the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and the receiver.
  • Connect the equipment to an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.