- PRODUCT SPECIFICATION
- Application
- Quality
- Appearance and Characteristics
- Overall Service Scenario
- General Features
- Absolute Maximum Rating
- Electrical Specification
- Mechanical Information
- User Quick Manual
- Disclaimers
- FCC STATEMENT
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
ATEC IOT TWZT-S001D-P Pole Zigbee Module
PRODUCT SPECIFICATION
Model | Part Number | Customer P/N |
---|
Pole Zigbee Module
| ****
TWZT-S001D-P
| ****
–
DESIGNED | CHECKED | APPROVED |
---|---|---|
2023.01.26 | 2023.01.26 | 2023.01.26 |
J.B.KIM | J.S.YEON | I.U.KIM |
SPECIFICATION
MODEL| TWZT-S001D-P| REV. No.| Rev. 0.1
REG. DATE| 2023.04.01| PAGE| 31
REV. DATE| –| –| –
Revision History
Revision | Date | Contents of Revision Change | Remark |
---|---|---|---|
0.0 | 2023.04.01 | Initial Release | J.B. Kim |
Application
This Specification is applied to ATEC IoT Pole Zigbee Module(TWZT-S001D-P). TWZT-S001D-P is a Common Zigbee Module solution for IEEE 802.15.4(6LoWPAN) applications. The robust network with PA(Power Amplifier) and diverse interface(SPI, UART, I2C) make it possible to be used as various kinds of applications. In particular, it is suitable for Gen2 Gateway and RTLS Anchor. TWZT-S001D-P is composed of RF IC and necessary external components including the Dipole Ant.
Quality
Quality should meet each condition which mentioned on this specification. However, the items which are not mentioned on this specification follow the inspection agreements and standards that are agreed upon with both companies.
Appearance and Characteristics
Appearance
Appearance should not be contaminated by harmful materials and should not have
cracks, etc. Mechanical dimensions should meet the contents of clause 8.
Characteristic
Electrical Characteristics should meet the contents of clause 7.
Overall Service Scenario
General Features
Description
Item | Description |
---|---|
Size | 42.3 x 28.0 x 9.8 (mm) |
Weight | Typ. 6g |
Memory
| Internal Flash : 512KB SRAM : 32KB
Power
|
Operating Voltage : Typ. 3.3V (2.3V~3.6V)
RF
| Tx Power| Max.10dBm
Data Rate| 250kbps
Antenna| Dipole Antenna
Network
| 20pin Interface| UART for FW Downloading SPI for Communication
Wireless| 2.4GHz IEEE802.15.4 compliant RF Transceiver Range Extender (PA/LNA)
Security| Robust wireless network (ATEC IoT own protocol)
Protocol| Compatible with ATEC IoT protocol communication devices
Comm. Range| Max. 30m (under LoS) (1)
- LoS (Line of Sight) : Without any sort of an obstacle between a gateway and end devices
Absolute Maximum Rating
Environmental Conditions
The normal operating environmental conditions are those as below. In such
conditions, ESL must conform with the present specification. The conformity to
such requirements must be certified by the manufacturer.
Parameter | Condition | Min. | Typ. | Max. | Unit |
---|
Operating Environment
| Temperature| -20| –| 85| ℃
Humidity| –| 35| 80| %RH
Storage Environment
| Temperature| -30| –| 85| ℃
Humidity| –| 35| 80| %RH
[Notice]
- TWZT-S001D-P is designed to be used indoors/Ceiling. It does not guarantee outdoor conditions.
Electrical Conditions
The operating electrical conditions are those as below. In such conditions,
the ESL must conform with the present specification. All devices can be
damaged or non-operated over the specification as below. The conformity to
such requirements must be certified by the manufacturer.
Parameter | Condition | Min | Typ. | Max | Unit |
---|---|---|---|---|---|
Supply Voltage | DC Power Supply | 2.3 | 3.3 | 3.6 | V |
Power Consumption
| @ 3.0~3.3V (Active Tx)| –| –| 200| mA
@ 3.0~3.3V(Active Rx)| –| –| 15| mA
ESD Protection
| HBM(150pF/330Ω) (1)
Air Condition @Soft Fail
|
-8
|
–
|
+8
|
kV
[Notice]
- TWZT-S001D-P is ESD ESD-sensitive device. Precaution should be used when handling the device to prevent permanent damage.
Electrical Specification
IEEE802.15.4
The TWZT-S001D-P supports IEEE802.15.4.
General Specification
- Standard : Only IEEE802.15.4 PHY
- Frequency : 2405 ~ 2480MHz
- Channel : 16CH. (5MHz Spacing)
- Modulation : DSSS/O-QPSK
- Max. Data Rate: 250Kbps
Electrical Specification
- Channel power depends on each country’s regulations (EX. KC, etc)
- The electrical specification which is shown below is ATEC IoT internal specification.
- All values depend on the surrounding environment and the current statement of an access point
RF Performance
Parameter| Condition| Min| Typ| Max| Unit
Output Power| | –| –| 10| dBm
Receiver Sensitivity| PER=1% (Required -85dBm)| -85| –| –| dBm
Maximum Input Level| PER=1% (Required -20dBm)| –| –| -20| dBm
Frequency Tolerance| Required Max. ±75kHz| -75| –| 75| kHz
Error Vector Magnitude| Required Max. 35%| –| –| 35| %
Antenna Performance
Antenna
The TWZT-S001D-P supports IEEE802.15.4.
Radiation Pattern and Gain
[Notice]
- This data is measured when TWZT-S001D-P is connected to the 4th Slot of Gen2 Gateway Board. Gen2 Gateway has 7 slots for diverse modules. The 4th Slot is the middle slot of whole 7 slots of it.
Antenna Performance
Gen2 Gateway Slot Information
Interface Information
# | Name | I/O | Description |
---|---|---|---|
1 | GND | G | Common ground |
2 | SPI_CS | O | Enable input for SPI interface |
3 | SPI_MISO | I | SPI data input |
4 | WAKE UP | O | wake up signal |
5 | UART_TX | I | NC |
6 | UART_RX | O | NC |
7 | VDD | P | 3.3V external DC supply |
8 | VDD | P | 3.3V external DC supply |
9 | GND | G | Common ground |
10 | GND | G | Common ground |
11 | GND | G | Common ground |
12 | NC | – | NC |
13 | TEST_PIN | O | Firmware Download Enable Pin |
14 | GND | G | Common ground |
15 | RESET | I | Reset input/output(active low) |
16 | IRQ | I | Interrupt output to the host processor |
17 | GND | G | Common ground |
18 | SPI_CLK | I | SPI interface clock |
19 | SPI_MOSI | O | SPI data input |
20 | GND | G | Common ground |
Mechanical Information
Mechanical Dimension
Size | 42.3 x 28.0 x 9.8 mm |
---|---|
Weight | Typ. 6g |
Assembly
User Quick Manual
Pole Zigbee Module User Manual
Pole Zigbee Module is suitable for Gen2 Gateway. 3 Slots of Gen2 Gateway can be used for Zigbee. To fulfill the ESL System, at least 3 Pole Zigbee Modules should be inserted to the Gateway. Likewise, this picture, when you insert modules, be careful with the directions. Modules will not be able to be put in when the inserting direction is opposite.
LED Alarming
When Modules are working abnormally, three LEDs(Power, Status, Ethernet)
would blink to alarm the unusual state.
- The abnormal phenomenon could happen when you force pull out the modules or module malfunctions.
Disclaimers
- ATEC IoT is not responsible for any damages caused by any accidents or operational environments exceeding the absolute maximum ratings.
- Consultation with ATEC IoT is recommended for unassured environments or operations to avoid any possible malfunctions or damages to the products or risk to life or health.
- Any unauthorized, without prior written consent from ATEC IoT, disassembly is prohibited if purposed for reverse-engineering. All defective devices must be reported to ATEC IoT and not to be disassembled or analyzed.
- The product information can be modified and upgraded without prior notice.
- Rule Part 15.19(a)(3): This device complies with part 15 of the FCC Rules.
Operation is subject to the following two conditions:
- This device may not cause harmful interference, and
- this device must accept any interference received, including interference that may cause undesired operation.
Rule Part 15.21: The user’s manual or instruction manual for an intentional or unintentional radiator shall caution the user that changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
FCC STATEMENT
Note: This equipment has been tested and found to comply with the limits for a Class B digital
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, according to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used under the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and the receiver.
- Connect the equipment to an outlet on a circuit different from that to which the receiver is connected.