ASD Lighting ASD-OLCLS-1D9CC-BZ LED Square Cylinder Wall Light Fixture Instruction Manual
- June 15, 2024
- ASD Lighting
Table of Contents
ASD Lighting ASD-OLCLS-1D9CC-BZ LED Square Cylinder Wall Light Fixture
Product Description
- DESIGN – LED ROUND OUTDOOR WALL CYLINDER has a modern design with effective up/down illumination. This fixture has a tempered glass cover and a durable die-cast aluminum body. It is designed to operate on 120V circuits and provides smooth triac dimming capabilities ranging from 10% to 100%.
- COLOR SELECTABLE – You can choose either a 3,000K warm white, 4,000K cool white or 5,000K daylight color temperature.
- PHOTOCELL – The built-in Dusk to Dawn Photocell will automatically turn the fixture on/off depending on the time of day.
- Durable waterproof housing resistant to rust and impact can be used outdoors in all weather conditions.
- APPLICATION – The fixture is rated for Wet Locations, making it perfect for indoor and outdoor projects such as decks, front doors, porches, patios, corridors, walkways, or any other common areas.
- ADVANTAGES – With a lifespan of 50,000 hours, these fixtures
are made to last decades under normal operation! ASD provides a 5-year limited warranty along with ETL certification to guarantee top quality products and safety!
Features
Model| Light direction| Watts| Voltage| Dimmable| Lumens| CCT| Finish|
Dimensions (LxWxH)| Option
---|---|---|---|---|---|---|---|---|---
ASD-OLCLS-1D9CC-BZ| 1| 9W| 120 V| TRIAC| 878/983/900 lm| 3CCT
(3,000/4,000/5,000 K)| Oil rubbed bronze| 5-13/16″ x 4-3/8″ x 7-7/8″| –
ASD-OLCLS-1D9CC-BK| 1| 9W| 120 V| TRIAC| 878/983/900 lm| 3CCT
(3,000/4,000/5,000 K)| Black| 5-13/16″ x 4-3/8″ x 7-7/8″| –
ASD-OLCLS-2D18CC-BZ| 2| 18W| 120 V| TRIAC| 1,737/1,974/1,807 lm| 3CCT
(3,000/4,000/5,000 K)| Oil rubbed bronze| 5-13/16″ x 4-3/8″ x 10-1/4″| –
ASD-OLCLS-2D18CC-BK| 2| 18W| 120 V| TRIAC| 1,737/1,974/1,807 lm| 3CCT
(3,000/4,000/5,000 K)| Black| 5-13/16″ x 4-3/8″ x 10-1/4″| –
OLCLS-PC WITH PHOTOCELL
ASD-OLCLS-1N9CC-PC-BK| 1| 9W| 120 V| –| 878/983/900 lm| 3CCT
(3,000/4,000/5,000 K)| Black| 5-13/16″ x 4-3/8″ x 7-7/8″| Photocell
ASD-OLCLS-2N18CC-PC-BK| 2| 18W| 120 V| –| 1,737/1,974/1,807 lm| 3CCT
(3,000/4,000/5,000 K)| Black| 5-13/16″ x 4-3/8″ x 10-1/4″| Photocell
ORDERING INFORMATION
Model | UPC | Pcs. per carton | Carton size | Carton weight | GTIN 14 |
---|---|---|---|---|---|
ASD-OLCLS-1D9CC-BZ | 810050736503 | 6 | 16.7″ x 15.4″ x 9.8″ | 15.3 lbs |
30810050736504
ASD-OLCLS-1D9CC-BK| 810050736497| 6| 16.7″ x 15.4″ x 9.8″| 15.3 lbs|
30810050736498
ASD-OLCLS-2D18CC-BZ| 810050736527| 6| 16.7″ x 15.4″ x 12.2″| 19.7 lbs|
30810050736528
ASD-OLCLS-2D18CC-BK| 810050736510| 6| 16.7″ x 15.4″ x 12.2″| 19.7 lbs|
30810050736511
OLCLS-PC WITH PHOTOCELL
ASD-OLCLS-1N9CC-PC-BK| 810050736817| 6| 16.7″ x 15.4″ x 9.8″| 15.3 lbs|
30810050736818
ASD-OLCLS-2N18CC-PC-BK| 810050736824| 6| 16.7″ x 15.4″ x 12.2″| 17.4 lbs|
30810050736825
PRODUCT SPECIFICATIONS
Construction & Materials
Housing| Aluminum
Lens| Glass
Finish| Oil rubbed bronze, Black
Weight| ASD-OLCLS-1D9CC-BZ| 2 lbs (0.9 kg)
ASD-OLCLS-1D9CC-BK
ASD-OLCLS-2D18CC-BZ| 2.5 lbs (1.1 kg)
ASD-OLCLS-2D18CC-BK
ASD-OLCLS-1N9CC-PC-BK| 1.9 lbs (0.9 kg)
ASD-OLCLS-2N18CC-PC-BK| 2.6 lbs (1.2 kg)
Environmental system
Work environment| Suitable for Wet Locations
Operating temperature| -40℉ to 113℉ (-40℃ to 45℃)
for PC models: -4℉ to 113℉ (-20℃ to 45℃)
L-70 Life| > 50,000 hrs
Optical system
Luminous flux| 1 light direction| 878/983/900 lm
2 light direction| 1,737/1,974/1,807 lm
Color temperature| 3CCT switch (3,000/4,000/5,000 K), 3,000 K by default
CRI| > 80
Electrical system
Input voltage| 120 V
Max input current| 1 light direction| 0.1 A
2 light direction| 0.2 A
Inrush current (Action time)| 1 light direction| 0.07 A (0.1 S)
2 light direction| 0.15 A (0.1 S)
Off state power| 0W
Power consumption| 1 light direction| 9W
2 light direction| 18W
Power factor| > 0.9
Max output current| 1 light direction| 0.25 A
2 light direction| 0.45 A
Surge protection DM/CM| 1.25 kV / 1.25 kV
Dimming compatible controls
Brand| Lutron| Leviton
Models| MACL-153MLH-WH| DVCL-153PR| R02-DW6HD-2RW| DSL06
STCL-153PH-WH| P PKG1W| R00-RNL06-0TW|
PD-6WCL-WH-R| | R68-06674-P0T
Regular and voluntary certifications
5-year limited warranty
cETLus certified 4001256
PACKAGE CONTENTS
Description | Q-ty |
---|---|
LED Square Outdoor Wall Cylinder | 1 |
Mounting plate (A) | 1 |
Mounting screw (B) | 2 |
Outlet box screw (C) | 2 |
Wire nut (D) | 3 |
Decorative nut (E) | 2 |
Waterproof gasket (F) | 2 |
Photocell cap (G) only for PC models | 1 |
Box | 1 |
BUILT-IN PHOTOCELL INFORMATION
The dusk-to-dawn sensor automatically turns the fixture off during daylight hours.
Specifications | Model: MD.EP-120R |
---|---|
Input power | 120 Vac, 60HZ |
Light level to turn ON | 30 ~ 150 lux (2.8 -14 fc) |
Light level to turn OFF | 200 ~ 800 lux (18.6-74.4 fc) |
Operating temperature | -4°F to 122°F (-20°C to 50°C) |
INSTALLATION GUIDE
IMPORTANT SAFETY INFORMATION:
Please read all the instructions below before installation.
- Make sure that the supply voltage corresponds to the rated product voltage.
- The product must be installed by a qualified electrician in accordance with the National Electrical Code and corresponding local codes.
- If the product is damaged, do not use it.
WARNING
RISK OF PERSONAL INJURY – READ and follow all WARNINGS and installation instructions. Keep or give to the owner for future reference
Risk of cuts: Wear gloves to prevent cuts or abrasions when removing from carton, handling, installing, and maintaining this product.
Risk of electric shock: This product must be installed in accordance with the applicable installation code by a person familiar with the construction and operation of the product and the hazards involved.
Risk of Fire : Minimum 194°F supply conductors. Consult a qualified electrician to ensure correct branch circuit conductor.
ASD® assumes no responsibility for claims arising out of improper or careless Installation or handling of this product.
ELECTRICAL SCHEMATIC DIAGRAM
INSTALLATION STEPS
-
Screw the two mounting screws onto the mounting plate. Attach the mounting plate to the outlet box using screws. Make sure the threads of the mounting screws are facing outside when the mounting plate is attached to the outlet box. In models with photocell option remove the photocell cap to make the dusk-to dawn sensor operate.
-
Choose needed color temperature by adjusting switch position. Connect the wires: Black to Black, White to White, Ground to Ground. Secure the connection with wire nuts.
-
Place the fixture base on the wall by aligning the protruding mounting screws through the holes on the wall plate. Put the waterproof gasket on each mounting screw. Tighten the fixture to the wall using two decorative nuts. For outdoor locations please use silicone (not included) shown in the picture below.
- The fixture must be mounted vertically with the photocell sensor facing up.
Customer Support
For most up-to-date spec sheets please refer to asd-lighting.com
ASD LIGHTING CORP
E-mail: orders@asd-lighting.com
Web site: www.asd-lighting.com
Read User Manual Online (PDF format)