unicore UM220-IV L Single Frequency Multi GNSS Timing Module User Manual
- June 15, 2024
- unicore
Table of Contents
INSTALLATION AND OPERATION
USER MANUAL
WWW.UNICORECOMM.COM
UM220-IV L
Single Frequency Multi-GNSS
Timing Module
UM220-IV L Single Frequency Multi GNSS Timing Module
Copyright© 2009-2023, Unicore Communications, Inc.
Data subject to change without notice.
Revision History
Version | Revision History | Date |
---|---|---|
R1 | Initial version | 2020-01-06 |
R1.1 | Update the range of VCC and V_BCKP | 2021-08-31 |
R1.2 | Add notes in Section 4.2 | 2021-11-17 |
R1.3 | If hot start is not used, connect V_BCKP to VCC. | |
Revise the VSWR in Table 1-2 | 2022-11-29 | |
R1.4 | Optimize Chapter 4.2 Antenna Design; | |
Optimize Chapter 4.1 Power Supply | 2023-04 |
Legal right notice
This manual provides information and details on the products of Unicore
Communication, Inc. (“Unicore”) referred to herein.
All rights, title and interest to this document and the information such as
data, designs, layouts contained in this manual are fully reserved, including
but not limited to the copyrights, patents, trademarks and other proprietary
rights as relevant governing laws may grant, and such rights may evolve and be
approved, registered or granted from the whole information aforesaid or any
part(s) of it or any combination of those parts.
Unicore holds the trademarks of “, “UNICORECOMM” and other trade name,
trademark, icon, logo, brand name and/or service mark of Unicore products or
their product serial referred to in this manual (collectively “Unicore
Trademarks”). This manual or any part of it, shall not be deemed as, either
expressly, implied, by estoppel or any other form, the granting or
transferring of Unicore rights and/or interests (including but not limited to
the aforementioned trademark rights), in whole or in part.
Disclaimer
The information contained in this manual is provided “as is” and is believed
to be true and correct at the time of its publication or revision. This manual
does not represent, and in any case, shall not be construed as a commitments
or warranty on the part of Unicore with respect to the fitness for a
particular purpose/use, the accuracy, reliability and correctness of the
information contained herein.
Information, such as product specifications, descriptions, features and user
guide in this manual, are subject to change by Unicore at any time without
prior notice, which may not be completely consistent with such information of
the specific product you purchase.
Should you purchase our product and encounter any inconsistency, please
contact us or our local authorized distributor for the most up-to-date version
of this manual along with any addenda or corrigenda.
Foreword
This document describes the product features and information of the hardware
design, installation, specification and the use of UNICORECOMM UM220-IV L
module.
Audience
This manual is created for the technical personnel, who possess the expertise
of GNSS receivers.
Product Introduction
1.1 Overview
UM220-IV L is a GNSS multisystem, high-precision timing module, based on the
low power, multisystem, high-performance SoC-UFirebird independently developed
by UNICORECOMM. It supports GPS, BDS, GLONASS and Galileo, etc. Moreover, it
is capable to receive and process data of two or three systems concurrently,
or work on a single system.
UM220-IV L module supports SBAS, QZSS and DGNSS input function, and provides
the advanced AGNSS function. It can improve the positioning speed through the
assistant data service of UNICORECOMM in the scenario of networking.
With the combined function of filter, linear amplifier and antenna protection,
and optimized RF architecture and interference rejection capability, UM220-IV
L module provides the reliable performance in complex electromagnetic
environments.
UM220-IV L module supports various timing modes including fixed-location
timing, optimized-location timing and positioning timing, which ensure the
good timing accuracy even in complex signal environmental conditions.
UM220-IV L module features compact dimensions, SMT PADS, full-automatic
integration of standard pick-and-place and reflow soldering, and is especially
suitable for low-cost, low-power applications. 1.2 Features
Table 1- 1 Product Feature
Grade | Size | GNSS | Supply | Interfaces | Features |
---|---|---|---|---|---|
Professional | Automotive | GPS/QZSS | BDS | GLONASS | Galileo |
Antenna Detection | 1PPS | Antenna Feed | Built-in flash | Update Rate | AGNSS |
DGNSS
●| | 17x22mm| ●| ●| ●| ●| ●| ●| ●| ●| ●| ●| ●| 1 Hz| ●| ●
1.3 Block Diagram
1.4 Performance
Table 1- 2 Specifications
Power
Voltage| 3.0~3.6VDC
Power Consumption1| 62mW @3.3V
RF Input
VSWR| ≤2.5
Input Impedance| 50Ω
Antenna Gain| 5~35dB
Physical Characters
Dimensions| 17.0mm22.4mm2.4mm
Weight| 1.7g
Environment
Operating Temperature| -40℃ ~ +85℃
Storage Temperature| -40℃ ~ +85℃
RoHS2.0| Compliant
Input/ Output Data Interface
UART| UART*2, LVTTL.
Baud Rate: 4800~115200 bps
GNSS Performance
Constellations| BDS B1: 1561.098MHZ GPS L1: 1575.42MHZ GLONASS L1OF: 1602MHZ
Galileo E1-B/C: 1575.42MHZ
TTFF2 (Time to First Fix)| Cold Start: 28s
Hot Start: 1s
Reacquisition: 1s
AGNSS3: 4s
Positioning Accuracy (CEP)4| 2.0m (Horizontal)
3.5m (Vertical)
Velocity Accuracy (RMS)5| 0.1m/s (Horizontal)
Sensitivity6| | GPS| BDS| GLONASS| Galileo
Cold Start| -147dBm| -144dBm| -142dBm| -135dBm
Tracking| -160dBm| -160dBm| -158dBm| -154dBm
Continuous positioning, typical value
All satellites C/N0 at 41
Assisted data injection in time| All satellites C/N0 at 41
All satellites C/N0 at 41
Tested with a good external LNA
---|---
| Hot Start| -155dBm| -151dBm| -150dBm| -143dBm
---|---|---|---|---|---
Reacquisition| -155dBm| -151dBm| -150dBm| -140dBm
1PPS (RMS)7| 20ns
Data Update Rate| 1Hz
Format| NMEA 0183,Unicore Protocol,RTCM3.2
1.5 Precision Timing and Raw Data Output
UM220-IV L module supports three timing modes: fixed-location timing,
optimizedlocation timing and positioning timing. Switch or query the above
timing modes throuCFGTM. It can also track all four GNSS systems including
GPS, BDS, GLONASS and Galileo, and switch back and forth between these four
systems using CFGGNSS.
UM220-IV L module is set to optimized-location timing mode by default, and
outputs information of real-time position and site-specific position, which
can be queried by TIMPPOS. Refer to UM220-IV L_Protocol Specification for more
details.
-
Fixed-location Timing
Fixed-location timing mode is applied to static scenes. In this mode, users are required to input the exact position of receiver antenna center through CFGTM manually, which are used by UM220-IV L module to calculate the distance between the antenna and the satellite, and calculate time to perform timing service. -
Optimized-location Timing
Optimized-location timing mode is another application used in static scenes. In this mode, the receiver collects a set number of positioning points (within observation time) and calculates the exact position of the antenna. After that, the exact position is locked down, and the timing mode is switched to the fixed-location timing mode.
The observation time and accuracy are configured through CFGTM, but only when both above-mentioned conditions are met to use fixed-location timing mode. Query the observation status through TPFINFO.
The position estimation process is only required once after the UM220-IV L is installed.
When the position optimization is completed, the timing mode set in the receiver automatically switches to the fixed-location timing mode.
7 Open sky
If the position of UM220-IV L antenna changes, the command CFGTM must be sent again to switch the timing mode back to the optimized position mode to recalibrate the antenna position.
Refer to UM220-IV L_ Protocol Specification for more details. -
Positioning Timing
Positioning timing is the only timing mode that supports dynamic timing. In this mode, UM220-IV L calculates the antenna position and time in real time. The timing quality depends on the satellite environment, and it is difficult to guarantee the timing accuracy.
1.6 Pulses per Second (1PPS)
UM220-IV L module provides a pulse width output and 1PPS signal of which the
pulse polarity is adjustable, and can be configured and queried through CFGTP.
TIMTP is used to describe the related 1PPS information including the
corresponding time and time accuracy indicators.
1.7 UART
Two UART interfaces are integrated in the UM220-IV L module. UART1 is the
master serial port, supports data transmission and firmware upgrade, the I/O
signal type is LVTTL. The default baud rate varies according to the version of
firmware and the baud rate can be configured by users 8 . Please ensure that
UART1 is connected to a PC or external processor to support firmware upgrade.
Serial 2 only supports data transmission and is unavailable for firmware
upgrade, only for backup.
1.8 Protocol
Table 1- 3 Supported Interface Protocols
Protocol | Type |
---|---|
NMEA0183 | I/O, ASCII, NMEA3.0, NMEA4.1(Default output) |
Unicore Protocol | I/O, ASCII, Unicore Protocol |
RTCM⁹ | Input, RTCM3.2 |
8-9 Refer to UM220-IV L_Protocol Specification for more details
1.9 Clock
The industrial TCXO is built into the UM220-IV L module to ensure the
stability of the clock system and the ability to capture signals quickly in
weak signal environments. UM220-IV L also integrates the 32k crystal to
maintain the RTC clock. When the main power supply is removed, the normal
operation of the RTC can be maintained by providing V_BCKP.
1.10 Antenna
The filter and linear amplifier are built in the UM220-IV L module. They
support active antennas and passive antennas, and the former provides better
performance.
Installation
2.1 Prerequisites
Most components on the UM220-IV L module are static sensitive devices (SSD)
and require ESD protection for IC circuits and other devices. Perform the
following protection measures before opening antistatic plastic boxes.
- Perform the steps in section 2.2 Installation in the correct order;
- Electrostatic discharge (ESD) may cause a damage to the device. All operations referred to in this section should be performed on an ESD workbench using wrist straps and conductive foam pads. If there is no anti-static workbench, wear wrist straps and connect their other ends to the metal frame to avoid electrostatic damages;
- Hold the edge of the module, do NOT touch the components directly;
- Carefully check the module for any apparent loose or damaged components. If there are any questions, please contact Unicore or the local distributors.
Figure 2- 1 Typical Installation of UM220-IV L shows the typical installation
of the UM220-IV L EVK.
Have the following accessories ready before starting the installation:
- UM220-IV L EVK (including a power supply)
- UM220-IV L User Manual
- uSTAR_L executable file
- Qualified GNSS antennas
- Antenna cable
- Straight-through cable
- Desktop or laptop computer with serial port and installed with uSTAR_L
Please keep the packing box and anti-static box for storage and handling.
2.2 Installation
Follow the below steps to install UM220-IV L and EVK.
Step 1. Ensure adequate anti-static measures, such as wrist straps,
workbench grounding, etc.
Step 2. Open UM220-IV L EVK suite, and take out the evaluation board.
Step 3. Select the GNSS antenna with the appropriate gain (the system
frequency supported by the antenna should be consistent with the module), fix
it in the non-occluded area, and use the appropriate cable to connect the
antenna and the UM220-IV L EB (evaluation board);
Step 4. Connect the PC to the EVK serial port using a straight-through
cable.
Step 5. Power on the evaluation board and initialize UM220-IV L.
Step 6. Open the uSTAR_L software.
Step 7. Configure the receiver through uSTAR to display constellations
view, messages, and receiver status, etc.
Technical Specifications
3.1 Electrical Specifications
Table 3- 1 Absolute Maximum Ratings
Parameter | Symbol | Min | Max | Units | Condition |
---|---|---|---|---|---|
Power Supply Voltage | VCC | -0.5 | 3.6 | V | |
VCC Maximum Ripple | Vrpp | 0 | 50 | mV | |
Backup Power Supply Voltage | V_BCKP | -0.5 | 3.6 | V | |
Antenna Bias Voltage | V_ANT | 6 | V | ||
VCC_RF Voltage | VCC_RF | 3.6 | V | ||
Input Pin Voltage | Vin | -0.5 | VCC+0.2 | V | |
Storage Temperature | Tstg | -40 | 85 | ℃ | |
Maximum ESD Stress | VESD (HBM) | 500 | V |
3.2 Operating Conditions
Table 3- 2 Operating Conditions
Parameter| Symbol| Min| Typical Value| Max|
Units| Condition
---|---|---|---|---|---|---
Power Supply Voltage| VCC| 3.0| 3.3| 3.6| V|
Peak Current| Iccp| | | 100| mA| VCC=3.0V
Backup Power Supply Voltage| V_BCKP| 1.65| | 3.6| V|
Antenna Bias Voltage| V_ANT| 2.8| | 5.5| V|
VCC_RF Voltage| VCC_RF| | VCC-0.1| | V|
Low Level Input Voltage| Vin_low| | | 0.2VCC| V|
High Level Input Voltage| Vin_high| 0.7VCC| | | V|
Low Level Output Voltage| Vout_low| | | 0.4| V| Iout=8mA
High Level Output Voltage| Vout_high| VCC–0.4| | | V| Iout=8mA
Antenna Gain| Gant| 5| | 35| dB|
Noise Figure| Nftot| | 4| | dB|
Operating Temperature| Topr| -40| | 85| ℃|
3.3 Mechanical Specifications
Table 3- 3 Dimensions
Parameter | Min (mm) | Typical Value (mm) | Max (mm) |
---|---|---|---|
A | 22.1 | 22.4 | 23.0 |
B | 16.9 | 17.0 | 17.1 |
C | 2.1 | 2.4 | 2.7 |
D | 2.45 | 2.55 | 2.85 |
E | 1.0 | 1.1 | 1.2 |
F | 3.7 | 3.8 | 3.9 |
G | 2.75 | 2.85 | 3.15 |
H | 0.82 | ||
K | 0.7 | 0.8 | 0.9 |
M | 0.9 | 1.0 | 1.1 |
N | 0.4 | 0.5 | 0.6 |
3.4 Pin Definition
Table 3- 4 Pin Definition
No | Name | I/O | Electrical Level | Description |
---|---|---|---|---|
1 | TXD2 | O | LVTTL | COM2 is for data transmission. Firmware upgrade is not |
supported.
Leave this pin floating if idle.
2| RXD2| I| LVTTL| COM2 is for data transmission. Firmware upgrade is not
supported.
Leave this pin floating if idle.
3| TXD1| O| LVTTL| COM1 is for data transmission. Firmware upgrade is
supported.
4| RXD1| I| LVTTL| COM1 is for data transmission. Firmware upgrade is
supported.
5| NC| | |
6| VCC| I| 3.0V~3.6V| Power supply
7| GND| | | Ground
8| VCC_OUT| O| 3.0V~3.6V| Power supply output, leave this pin floating if idle
9| NC| | |
10| nRESET| I| LVTTL| External Reset Pin, low active
11| V_BCKP| I| | When the main power supply VCC of the module is cut off,
V_BCKP supplies power to RTC and SRAM;
Current value is about 50μA.
V_BCKP is necessary for hot start. If you do not use the hot start function,
connect V_BCKP to VCC. Do NOT leave it floating or connect it to ground.
12| NC| | |
13| GND| —| | Ground
14| GND| —| | Ground
15| GND| —| | Ground
16| RF_IN| I| | GNSS signal input
17| GND| —| | Ground
18| VCC_RF| O| | RF power supply output, leave this pin
floating if idle
19| V_ANT| I| | Antenna bias voltage, ground this pin if idle
20| ANT_DET_N| I| | Open circuit detection of the active antenna
21| NC| | |
22| NC| | |
23| NC| | |
24| NC| | |
25| NC| | |
26| NC| | |
27| NC| | |
28| TIME PULSE| LVTTL| | 1PPS, leave this pin floating if idle
3.5 PCB Packaging
When designing PCB solder mask, make sure that the area under UM220-IV l module is completely coated with solder mask.
Hardware Design
4.1 Power Supply
4.1.1 Main Supply (VCC)
The voltage range of VCC is 3.0 V ~ 3.6 V.
Notes:
- The VCC initial level when power-on should be less than 0.4 V.
- The VCC ramp when power-on should be monotonic, without plateaus.
- The voltages of undershoot and ringing should be within 5% VCC.
- VCC power-on waveform: The time interval from 10% rising to 90% must be within 100 μs ~ 10 ms.
- Power-on time interval: The time interval between the power-off (VCC < 0.4 V) to the next power-on is recommended to be larger than 500 ms.
4.1.2 Backup Supply (V_BCKP)
If the hot start function is needed, users should supply backup power to the
module. The voltage range of V_BCKP is 1.65 V ~ 3.6 V.
Notes:
- The V_BCKP initial level when power-on should be less than 0.4 V.
- The V_BCKP ramp when power-on should be monotonic, without plateaus.
- The voltages of undershoot and ringing should be within 5% V_BCKP.
- V_BCKP power-on waveform: The time interval from 10% rising to 90% must be within 100 μs ~ 10 ms.
- Power-on time interval: The time interval between the power-off (V_BCKP < 0.4 V) to the next power-on is recommended to be larger than 500 ms.
- The V_BCKP pin cannot be floating or connected to ground. When V_BCKP is not used, it should be connected to VCC or connected to backup power.
4.2 Antenna Design
4.2.1 Passive Antenna
The RF input port of the module can be connected directly to the RF_IN without
providing a DC voltage. There are a few things to note when using a passive
antenna:
- Select a proper installation position of the antenna to reduce the interference of electromagnetic noise, so as to enable the optimum performance of the antenna;
- A 50 impedance match of RF link is needed;
To improve the performance of RF analog front-end, a low noise amplifier (LNA)
can be added behind the passive antenna. UM220-IV L module provides a 3.3V
power supply (VCC_RF) for LNA.
Note: If the user has a high requirement for ESD (higher than the maximum
specification in User Manual), the user should consider other method to power
the LNA rather than using the VCC_RF pin. In this case, it is recommended to
choose a power supply chip with high ESD protection level. Gas discharge tube,
varistor, TVS tube and other high-power protective devices may also be used in
the power supply circuit to further protect the module from ESD damage or
other Electrical Over-Stress (EOS). 4.2.2 Active Antenna
The active antenna increases the system power consumption when improving the
system performance. The 3.3V Power Supply (VCC_RF) provided by the UM220-IV l
module can be used to power the antenna directly if the function of detecting
the state of the antenna inside the module is not used and the working voltage
of the antenna is 3.3V. If the user has a high requirement for ESD (higher
than the maximum specification in User Manual), the user should consider other
method to feed the antenna rather than using the VCC_RF pin. In this case, it
is recommended to choose a power supply chip with high ESD protection level.
Gas discharge tube, varistor, TVS tube and other high-power protective devices
may also be used in the power supply circuit to further protect the module
from ESD damage or other Electrical Over-Stress (EOS).
When the working voltage of the active antenna is not 3.3V, the antenna can be
powered by the external power supply.
If the antenna power supply and the module’s main supply VCC use the same
power rail, the ESD, surge and overvoltage from the antenna will have an
effect on VCC, which may cause damage to the module. Therefore, it’s
recommended to design an independent power rail for the antenna to reduce the
possibility of damage to the module. 4.2.3 Active Antenna State Detection
UM220-IV L module can detect the active antenna state including open-circuit,
shortcircuit and normal state. The host computer enables or disables the
antenna state detection function by transmitting commands via serial ports,
and receives the detected antenna state via serial ports. The module cuts off
the power supply automatically when detecting the short-circuit state of
antenna.
-
Antenna Short-circuit Detection
If the antenna short-circuit detection function is required, connect the antenna power supply to the module’s V_ANT Pin after cascading an appropriate value of resistance, and feed the antenna through the internal switch. If the V_ANT pin is directly connected without a serial resistor, the module will be damaged when the antenna is shortcircuited. The internal switch is turned off by default, which can be switched with the CFGANT command. When the module detects an antenna short-circuit, the antenna feed is cut off immediately through the internal switch, periodically feeds the antenna and detects the state. Use ANTSTAT for the query.
If the working voltage of the antenna is 3.3V, the 3.3V power supply (VCC_RF) provided by the module can be connected in series with a 10Ω resistor to the VANT pin, and turn on the internal switch through CFGANT to power the antenna. If an antenna short circuit is detected at this time, the module will automatically turn off the switch. When there is a need to save the power consumption, turn off the switch through CFGANT.
Refer to UM220-IV L Protocol Specification for more details When the working voltage of the antenna is 5V, the antenna can be powered by connecting an external power supply with a 10Ω serial resistor to the V_ANT pin. Since this power supply is directly connected to the RF_IN pin of the module, this power
supply cannot introduce noise. It’s recommended to use the power supply from analog network. -
Antenna Short-circuit and Open-circuit Detection
If the short-circuit and open-circuit detection functions of the module are required concurrently, use the ANT_DET_N pin to cooperate with an external circuit. The threshold current for open circuit detection can be calculated by formula (4-1). When the antenna working current is less than the calculated value, the module determines that the antenna is open-circuit. The resistance of the series resistor R1 can be adjusted according to the antenna working current.
If an external power supply is used to power the antenna, the maximum power
supply voltage cannot exceed 5.5V to protect the ANT_DET_N pin.
Use ANTSTAT to query the antenna state.
4.3 UART
The two serial ports of UM220-IV L are LVTTL levels, which need to be
converted through RS232 level if connected to PC. It is recommended that users
reserve a test point for serial port 2 as the debug port.
If there is data input on the module input ports (RXD, GPIO) when the module
is not powered on, it will form power leakage on the module VCC. When the
leakage voltage is higher than 1.6V, it may cause a start failure when the
module is powered on. To prevent the leakage power, ensure that the IO port
connected to the module is in high impedance or low level when the module is
not powered on.
4.4 RESET Time Sequence
There is a reset chip inside the module. When VCC is lower than 2.63V (typical
value of ambient temperature) or nRESET is at low level, the module is in
reset state. After VCC rises to 2.63V or nRESET changes from low to high, the
reset state of the chip will continue to remain for 200ms.
It is recommended to keep the reset signal of the nRESET pin for 10ms after
VCC is valid at power-up. During normal operation, the minimum valid time of
the reset signal for the nRESET pin is 500ns.
4.5 TIME PULSE Output
The period of the TIME PULSE output signal is 1s, the peak-to-peak value is
VCC, and the default duty cycle is 10%.
4.6 Layout Recommendation
-
Power supply: Stable and low ripple power is necessary for good performance.
Make sure the peak-to-peak voltage ripple does not exceed 50mV.
− Use LDO to ensure the purity of power supply;
− Place LDO to the module as close as possible in layout;
− Widen the power circuit wiring or use split copper surface to transmit current;
− Avoid the high–power or high inductance devices such as magnetic coil. -
Antenna interface: note with the antenna impedance matching, and the circuit is short and smooth, try to avoid acute angles.
-
Connect the RF signal to the antenna and make sure the 50 Ω impedance match on the circuit.
-
Antenna location: to obtain a good signal-to-noise ratio, ensure that the antenna is well isolated from electromagnetic radiation sources, especially electromagnetic radiation in the frequency range of 1559 to 1605 MHz.
-
Try to avoid circuits below the UM220-IV L module.
-
UM220-IV L module is a temperature sensitive device, rapid temperature changes will result in reduced performance. Keep it as far away from the highpower high-temperature air and heating devices as possible.
Packaging
5.1 Product Labeling
5.2 Packaging Description
UM220-IV L modules use carrier tape and reel (suitable for mainstream surface
mount equipment), packaged in vacuum-sealed aluminum foil antistatic bags,
with a desiccant inside to prevent moisture. When using reflow welding process
to weld modules, please strictly comply with IPC standard to conduct humidity
control on modules. As packaging materials such as carrier belt can only
withstand the temperature of 65 degrees Celsius, modules shall be removed from
the packaging during baking.
Table 5- 1 Package Instructions
Item | Description |
---|---|
Module | 500 pics/reel |
Reel size | Tray: 13″ external diameter: 330mm, internal diameter: 100mm, |
width: 24mm thickness: 2.0mm
Carrier tape| Space between: 20mm
UM220-IV L module is rated at MSL level 3, refer to the relevant IPC/JEDEC
standards for baking requirements. Please access to the website www.jedec.org
to download for details.
The shelf life of UM220-IV L module is one year.
Soldering and Disassembly
6.1 Disassembly
When it is necessary to remove the module, it is recommended to melt the
soldering tin of the pins on both sides of the module with an electric
soldering iron and remove the module with tweezers. Do NOT use other means to
remove the module (for example, the module is blown off by a hot air gun),
which may lead to module damage.
6.2 Clean
Do NOT use alcohol or other organic solvents to clean, it may lead to flux
residues into the shielding shell, causing mildew and other problems
6.3 Reflow Soldering
In order to avoid component falling off, the module should be placed on the
upper part of the motherboard when soldering. The reflow temperature curve is
recommended as shown in figure 6-1 below (M705-GRN360 is recommended for
solder paste).
Note: The module can only be soldered once.
Unicore Communications, Inc.
F3, No.7, Fengxian East Road, Haidian, Beijing, P.R.China,
100094
www.unicorecomm.com
Phone: 86-10-69939800
Fax: 86-10-69939888
info@unicorecomm.com
Documents / Resources
|
unicore UM220-IV L Single Frequency Multi GNSS Timing
Module
[pdf] User Manual
UM220-IV L Single Frequency Multi GNSS Timing Module, UM220-IV L, Single
Frequency Multi GNSS Timing Module, Multi GNSS Timing Module, GNSS Timing
Module, Timing Module
---|---
References
- Home | JEDEC
- 和芯星通北斗导航芯片-北斗导航模块北斗高精度定位板卡国内外领先的芯片、OEM板卡和产品解决方案提供商
- 和芯星通北斗导航芯片-北斗导航模块北斗高精度定位板卡国内外领先的芯片、OEM板卡和产品解决方案提供商
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>