hama WS-200 Weather Station Instruction Manual

June 15, 2024
Hama

hama WS-200 Weather Station

Specifications

  • Product Name: Weather Station Wetterstation
  • Model Number: EWS-200
  • Power Supply (Base Station): 2 x AAA batteries (3.0 V)
  • Power Supply (Measuring Station): 2 x AAA batteries (3.0 V)
  • Measuring Range (Temperature): –
  • Measuring Range (Humidity): –
  • Max. Number of Measuring Stations: 3
  • Range: 30 m
  • Frequency Band(s): –
  • Maximum Radio-Frequency Power Transmitted: –

Product Usage Instructions

Getting Started

  • Before use, ensure you insert the batteries in the measuring station first and then in the base station.

Installation

  • Warning: Only mount the weather station on a wall or any other surface intended for this purpose.

Operation

  • Hold down the UP button (23) or the DOWN/MEM button (24) to select values faster.
  • The device will automatically search for a connection to the measuring station and perform the initial setup.

Basic and Manual Settings

Controls and Displays (Base Station)

  • Alarm Symbol (1)
  • Battery Symbol (Base Station) (2)
  • Summer Time (3)
  • Weather Forecast Symbol (4)
  • Room Temperature (5)
  • Comfort Range (6)
  • Channel Display (7)
  • Outdoor Temperature (8)
  • Radio Symbol (9)
  • Time (10)
  • Day (11)
  • Month (12)
  • Weekday (13)
  • Moon Phase (14)
  • Room Temperature Trend (15)
  • Room Humidity (16)
  • Measuring Station Radio Symbol (17)
  • Outdoor Humidity (18)
  • Outdoor Temperature Trend (19)
  • Outdoor Temperature Alarm (20)
  • Battery Symbol (Measuring Station) (21)
  • MODE Button (22) – Used for settings, confirming the setting, and alarm setting
  • UP Button (23) – Used to increase the current setting or activate/deactivate manual radio signal reception
  • DOWN/MEM Button (24) – Reduces the current setting and accesses the saved maximum/minimum values
  • CH Button (25) – Channel selection and manual search for a signal from the measuring station
  • ALERT Button (26) – Used for setting, activating, and deactivating the outdoor temperature alarm
  • SNZ/LIGHT Button (27) – Stops the alarm and activates the backlight for approximately 10 seconds
  • Battery Compartment (28)

Controls and Displays (Measuring Station)

  • Display (on front side) (29) – Displays temperature, humidity, and current channel
  • LED Indicator (on front side) (30) – Flashes when signals are transmitted
  • Opening for Wall Mounting (31)
  • Set the Transmission CHANNEL (1-3) (32) – Input channel for the weather station. Set the channel before inserting the batteries.
  • Battery Compartment (33)

Warranty Disclaimer

Hama GmbH & Co KG assumes no liability and provides no warranty for damage resulting from improper installation/mounting, improper use of the product, or failure to observe the operating instructions and/or safety notes.

Technical Data

Base Station:

  • Power Supply: 2 x AAA batteries (3.0 V)
  • Measuring Range (Temperature): –
  • Measuring Range (Humidity): –
  • Max. Number of Measuring Stations: 3
  • Range: 30 m

Measuring Station:

  • Power Supply: 2 x AAA batteries (3.0 V)

FAQ

Q: What are the package contents?

  • A: The package includes [insert package contents here].

Q: How do I select values faster?

  • A: Hold down the UP button (23) or the DOWN/MEM button (24) to select values faster.

Q: How many measuring stations can be connected to the base station?

  • A: You can connect up to 3 measuring stations to the base station.

Q: What is the range of the weather station?

  • A: The range of the weather station is 30 meters.

Q: Where can I find the full text of the EU declaration of conformity?

  • A: The full text of the EU declaration of conformity is available at the following internet address: https://de.hama.com

Operating instruction

Controls and Displays

A) Base station

  1. Alarm symbol
  2. Battery symbol (base station)
  3. Summer time
  4. Weather forecast symbol
  5. Room temperature
  6. Comfort range
  7. Channel display
  8. Outdoor temperature
  9. Radio symbol
  10. Time
  11. Day
  12. Month
  13. Weekday
  14. Moon phase
  15. Room temperaturetrend
  16. Room humidity
  17. Measuring station radio symbol
  18. Outdoor humidity
  19. Outdoor temperaturetrend
  20. Outdoor temperaturealarm
  21. Battery symbol (measuring station)
  22. MODE button settings/confirm the setting/alarm setting
  23. UP button increase the current setting/activate or deactivate manual radio signal reception
  24. DOWN/MEM button reduces the current setting/accessing the saved maximum/minimum values
  25. CH button channel selection/manual searchfor asignal from the measuring station
  26. ALERT button setting/activating/deactivating the outdoor temperature alarm
  27. SNZ/LIGHT button stops the alarm/activates the backlight (approx. 10 seconds)
  28. Battery compartment BMeasuring station
  29. Display (on front side) Displays temperature, humidity and current channel.
  30. LED indicator (on front side) Flashes when signals aretransmitted.
  31. Opening for wallmounting
  32. Set the transmission CHANNEL (1-3) Input channel for the weather station. Set the channel beforeinserting the batteries.
  33. Battery compartment

Important information -Quick guide

  • This quick-reference guide containsthe most importantbasic information,such as safety instructions andthe stepsnecessary to operate the product.
  • To help protect theenvironment and conserve valuable rawmaterials, Hama does not issue a printed manual andinstead makesthis available exclusively as aPDF download.
  • Thefulltext of the manual is available at the followinginternet address: www.hama.com- >00186310->Downloads
  • Save the manual on your computer for reference and print it out if possible.
Explanation of Warning Symbolsand Notes

Warning

  • This symbol is used to indicate safety instructionsortodraw your attention to specifichazards and risks.

Note

  • This symbol is used to indicate additional information or important notes.

Package Contents

  • EWS-200 weather station (base station for indoors/measuring station for outdoors)
  • 4AAA batteries
  • These operating instructions

Safety Notes

  • The product is intended for private, non-commercial use only.
  • Do not operate the product outside the power limits given in the specifications.
  • Do not use the product in moist environments and avoid splashes.
  • Do not use the product in the immediate vicinity of heaters or other heat sources or in direct sunlight.
  • Do not use the product in areas wherethe use of electronic devices is not permitted.
  • Only connect the product to asocket that has been approved for the device. The socket must be installed close to the product and easily accessible.
  • Do not drop the product and do not expose it to any major shocks.
  • Do not open the device or continue to operate it if it becomes damaged.
  • Do not attempt to service or repair the product yourself.Leave any and allservice work to qualified experts.
  • Keep the packaging material out of the reach of children due to the risk of suffocation.
  • Dispose of packaging material immediately according to locally applicable regulations.
  • Do not modify the product in any way.Doing so voids the warranty.
  • Use the product for its intended purpose only.

Warning –Batteries

  • When inserting batteries, note the correct polarity (+ and – markings) and insert the batteries accordingly.Failureto do so could result in the batteries leaking or exploding.
  • Only use batteries that match the specified type. Keep the instructions for the correct choice of batteries included with the operating instructions of devices safe for future reference.
  • Beforeyou insert the batteries, clean the battery contacts and the polarity contacts.
  • Do not allow children to change batteries without supervision.
  • Replace allthe batteries in aset at the same time.
  • Do not mix old and new batteries, or batteries of different types or from different manufacturers.
  • Remove the batteries from products that arenot being used for an extended period (unless these arebeing kept ready for an emergency).
  • Do not short-circuit batteries.
  • Do not charge batteries.
  • Do not burn batteries or heat them up.
  • Never open, damage or swallow batteries or allow them to enter the environment. They can contain toxic, environmentally harmful heavy metals.
  • Remove spent batteries from the product and dispose of them without delay.
  • Avoid storing, charging andusing in extreme temperatures and at extremely low atmospheric pressures (such as at high altitudes).
  • Ensurethat batteries with damaged housings do not come into contact with water.
  • Keep batteries out of the reach of children.

Getting Started

Note

  • Beforeuse, ensureyou insert the batteries in the measuring station first and then in the base station.

Installation

Note – Installation

  • We recommend initially placing the base and measuring stations in the intended locations without installing them and making all the settings described in 6. Operation – to do.
  • Only install the stations once the appropriate settings have been made and a stable wireless connection is established.

Note

  • The wireless transmission range between the measuring and base stations is up to 30 m in open spaces.
  • Before installation, ensure that wireless transmission will not be disrupted by interference or obstacles like buildings, trees, vehicles, high-voltage lines, etc.
  • Before the final installation, ensure that there is sufficient reception between the intended installation locations.
  • When installing the measuring station, ensure that it is protected from direct sunlight and rain.
  • The international standard height for measuring air temperature is 1.25 m (4 ft) above ground.

Warning

  • Buy special or suitable installation material from a specialised dealer for wall-mounting.
  • Ensure that no faulty or damaged parts are installed.
  • Never apply force during installation. This could damage the product.
  • Before installation, ensure that the chosen wall is suitable for the weight to be mounted, and make sure that there are no electrical wires, water, gas or other lines at the installation site on the wall.
  • Do not mount the product above locations where persons might linger.

Base station

  • Use the base to position the base station on a level surface.

Measuring station

  • You can also position the measuring station on a level outdoor surface.
  • We recommend installing the measuring station securely on an outdoor wall using the opening (31).
  • Install an anchor, screw, nail, etc. in the wall of your choice.
  • Hang up the base/measuring station using the opening intended for this purpose.

Operation

Note – Input

  • Hold down the UP button (23) or the DOWN/MEM button (24) to select the values faster.
Connection to the measuring station
  • After you insert the batteries, the base station automatically searches for a connection to the measuring station and performs initial setup.

Note

  • Initial setup takes approx. 3 minutes.
  • During connection, the wireless symbol on the measuring station will flash (17).
  • Do not press any buttons during setup. Otherwise, values may not be transmitted correctly and there is a risk of value errors and inaccuracies.
  • The setup process is completed when the indoor (5, 16) and outdoor (8, 18) measurement data is displayed.
Basic and manual settings

Automatic setting using the DCF signal

  • After the first time the base station is switched on and successful transmission is established between the base station and the measuring station, the clock will automatically search for a DCF signal. During the search, the wireless symbol (9) will flash.
  • Following successful signal reception, the radio symbol appears permanently and stops flashing.

Note – Time settings

  • The search process takes about 7 minutes. If it fails, the search ends.The radio symbol (9) disappears.
  • In the meantime, however, you can set the time and the date manually.
  • The clock automatically continues to search for the DCF signal on a daily basis (1:00, 2:00, 3:00, 4:00 and 5:00 a.m.). If the signal is received successfully, the manually set time and date are overwritten.

Note

  • Language and time zone are preset to Germany. You can find instructions and information on making changes in our detailed operating instructions at www.hama.com

Care and Maintenance

  • Only clean this product with a slightly damp, lint-free cloth and do not use aggressive cleaning agents. Make sure that water does not get into the product.

Warranty Disclaimer

  • Hama GmbH & Co KG assumes no liability and provides no warranty for damage resulting from improper installation/ mounting, improper use of the product or from failure to observe the operating instructions and/or safety notes.

Technical Data

**** Base station Measuring station
Power supply 3.0 V

2 x AAA batteries

| 3.0 V

2 x AAA batteries

Measuring range Temperature Humidity| 0°C – +50°C/ 32°F

– 122°F 20% – 95%

| -40°C – +60°C/

-40°F – 140°F 20% – 95%

Max. number of measuring stations|  3| ****

Range| ≤ 30 m

Declaration of Conformity

  • Hereby, Hama GmbH & Co KG declares that the radio equipment type [00186310] is in compliance with Directive 2014/53/EU. The full text of the EU declaration of conformity is available at the following internet address: https://de.hama.com00186310Downloads.
Frequency band(s) 433 MHz
Maximum radio-frequency power transmitted 4,932 mW
  • Service & Support
  • www.hama.com
  • +49 9091 502-0
  • All listed brands are trademarks of the corresponding companies.
  • Errors and omissions excepted, and subject to technical changes.
  • Our general terms of delivery and payment are applied.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals