COMMON SPECIFICATIONS FOR ALL UNITS
  • Calibration Reference Conditions
    • Accuracy (LH &R):± 0.25%, Best Straight Line (BSL) @ 75°F
    • Long Term Stability: Will repeat within ± 0.25% FSO of original calibration curve for 1 year
    • Proof Pressure: 2 times rated pressure range, or 13,000 psi, whichever is less
    • Life, Cycling: Full scale pressure cycles: 108 to 300 psi,107 to 1,000 psi, 106 to 7,500 psi
    • Vibration: 15 g’s, 10 to 2000 Hz (MIL-STD-202, M204, Cond . B)
    • Shock: 50 g’s, 11 ms (MIL-STD-202, M213, Cond.
    • Wetted Material: 300 series and 17- 4 PH stainless steel.
    • Electrical Connection: 1 meter jacketed cable, standard
    • Pressure Cavity Volume: 0.075 inches maximum
    • Enclosure Rating: NEMA 4 (Except 420 & 422 – NEMA 3)
  • MILLIVOLT OUTPUT MODELS 420 & 422
    • Excitation: 10 VDC (Nominal)
    • Output: 0 to 30 mV (420) 0 to 100 mV (422
    • Zero Output: 0 mV ± 2 mV
    • Full Scale Output: 30 mV ± 1 mV (420) (3 mV/V Ratiometric with Excitation Voltage) 100 mV ±1 mV (422) (10 mV/V Ratiometric with Excitation Voltage)
    • Resistance: 5000 ohms (nominal)
    • Temperature Range: Compensated: +30o to +160oF (-1o to 71oC) Operating: -40o to 185oF (-40o to 85oC) standard
    • Temperature Error: ±3.0% of FSO max over compensated range (420) ±1.0% of FSO max over compensated range (422)
    • Weight: 4.6 oz (131 grams)
    • Wiring: Red (+Excite) Bendix Pin A/Pin 1 Green (+Output) Bendix Pin B/Pin 3 White (-Output) Bendix Pin C/Pin 2 Black (-Excite) Bendix Pin D/Pin 4
    • VOLTAGE OUTPUT MODELS 423 (5 VDC OUTPUT) 426 (10 VDC OUTPUT)
    • Excitation: 9 to 30 VDC operating (423) 14 to 30 VDC operating (426)
    • Output: 0.5 to 5.5 VDC (423) 1 to 11 VDC (426)
    • Zero Output: 0.5 VDC, ± 2.0% of FSO (423) 1.0 VDC, ± 2.0% of FSO (426)
    • Full Scale Output: 5.5 VDC, ± 1.0% (423) 11 VDC, ± 1.0% (426)
    • Protection: Reverse polarity protected Minimum Load
    • Resistance: 2000 ohms
    • Temperature Range: Compensated: +30o to +130oF (-1o to 54oC) Operating: -40o to 185oF (-40o to 85oC)
    • Temperature Error: ±1.0% of FSO max over compensated range
    • Weight: 5.8 oz (166 grams)
    • Wiring: Red (+Excite) Bendix Pin A/Pin 1 White (+Output) Bendix Pin B/Pin 3 Black (Common) Bendix Pin C/Pin 2 Drain (Case Gnd)Bendix Pin D/Pin 4
  • CURRENT OUTPUT MODEL 425
    • Excitation: 12 to 30 VDC
    • Output: 4 to 20 mA
    • Zero Output: 4 mA, ± 2.0% of FSO @ 75°F
    • Full Scale Output: 20 mA, ± 1.0% @ 75°F
    • Protection: Reverse polarity protected
    • Loop Resistance: See loop resistance chart on back page
    • Temperature Range: Compensated: 0o to +160oF (-18o to 71oC) Operating: -40o to 185oF (-40o to 85oC)
    • Temperature Error: ±1.0% of FSO max over compensated range
    • Weight: 5.9 oz (167.5 grams)
    • Wiring: Red (+Excite) Bendix Pin A/Pin 1 Black (-Excite) Bendix Pin B/Pin 2 Drain (Case Gnd)Bendix Pin D/Pin 4
  • CALIBRATION
    All models are tested to meet or exceed the published specifications. The calibration and testing were done using instrumentation and standards traceable to the National Institute of Standards and Technology (NIST). Also tested in accordance with MIL-STD-45662A.

WARNING ! READ BEFORE INSTALLATION

Fluid hammer and surges can destroy any pressure transducer and must always be avoided. A pressure snubber should be installed to eliminate the damaging hammer effects. Fluid hammer occurs when a liquid flow is suddenly stopped, as with quick closing solenoid valves. Surges occur when flow is suddenly begun, as when a pump is turned on at full power or a valve is quickly opened.
Barksdale pressure transducers having a pressure range 2,000 psi and higher have a built in pressure surge protection in the input port. The design is such that an orifice is made an integral part of the pressure port. Designed with the upstream side of the orifice as a sharp corner, it acts as a very effective protection. Other orifice devices can be installed upstream of the pressure transducer in the piping system for extra protection where the system engineer requires it. Liquid surges are particularly damaging to pressure transducers if the pipe is originally empty. To avoid damaging surges, fluid lines should remain full (if possible), pumps should be brought up to power slowly, and valves opened slowly. To avoid damage from both fluid hammer and surges, a surge chamber should be installed, and a pressure snubber should be installed on every transducer. Symptoms of fluid hammer and surge’s damaging effects:

  1. Pressure transducer exhibits an output at zero pressure (large zero offset). If zero offset is less than 10% FS, user can usually re-zero meter, install proper snubber and continue monitoring pressures.
  2. Pressure transducer output remains constant regardless of pressure.
  3. In severe cases, there will be no output.

TORQUE REQUIREMENTS
Apply pipe compound sparingly to male pipe threads only. Avoid pipe strain on Transducer housing by properly supporting and aligning piping. Apply wrench to the hex flats of fittings only, then tighten the connection. Adequate support of piping and proper mounting of the pressure transducer should be made to avoid excessive shock and vibration.
TORQUE TO 125 – 150 pound inches.
CAUTION: For steam service, install a condensate loop (pigtail or steam siphon tube) between the steam line and the pressure transducer.

DIMENSIONS MILLIVOLT OUTPUT

PRESSURE RANGES 2000 TO 7500 PSI

AMPLIFIED OUTPUT

Barksdale 420 Series Pressure Transducers-fig4

WIRING MILLIVOLT OUTPUT

VOLTAGE OUTPUT

CURRENT OUTPUT

TYPICAL APPLICATION SCHEMATIC FOR 425 TRANSDUCER

Barksdale 420 Series Pressure Transducers-fig8

LOOP RESISTANCE CHART

ELECTRICAL CONNECTIONS

ADDITIONAL OPTIONS

(420, 422, 423, 425, 426 MODELS)

Bendix Connector
NEMA 3 4 Pin (PT02A-8-4P)
To order: replace H3 in catalog number with T2 Mating Connector (not provided) T2: Bendix PT06E-8-4S(SR)

NEMA 3 Mating Connector Hirschman model ELWIKA 4012 PG7

NEMA 3 Hirschman Connector model ELST 412 PG9
To order: replace H3 in catalog number with T4

PRESSURE PORT OPTION

7/16-20 UNF INTERNAL PORT To order: add -P1 suffix to catalog number

RETURN REQUESTS / INQUIRIES

  • Direct all warranty and repair requests/inquiries to Barksdale, Inc. Customer Service Department. Call 323-589-6181, FAX: 323-589-3463
  • BEFORE RETURNING ANY PRODUCT(S) TO BARKSDALE, YOU MUST OBTAIN A RETURNED MERCHANDISE AUTHORIZATION FROM OUR CUSTOMER SERVICE DEPARTMENT (IN ORDER TO AVOID PROCESSING DELAYS).
  • FOR WARRANTY RETURNS, please have the following information available BEFORE contacting Barksdale:
    • P.O. number under which the product was PURCHASED.
    •  Model number of the product under warranty.
    • Repair instructions and/or specific problems you are having with the product.
    • Application information.
  • FOR NON-WARRANTY REPAIRS OR CALIBRATION, consult Barksdale for current repair/calibration charges. Have the following information available BEFORE contacting Barksdale:
    • Your P.O. number to cover the COST of the repair/calibration.
    • Model number of product.
    • Repair instructions and/or specific problems you are having with the product.

Buy: www.valinOnline.com| Phone 844-385-3099| Email:CustomerService@valin.com

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals