MTI 2 Keyed Alike Tubular Cam Lock 5/8 Inch Camper User Manual
- June 15, 2024
- MTI
Table of Contents
- MTI 2 Keyed Alike Tubular Cam Lock 5/8 Inch Camper
- WHAT IN THE BOX
- Not included
- BATTERY
- KEY REGISTRATION (Standard Mode) – Complete Before Installation
- NETWORK MODE – Versa EX or Managed Access
- CAM Lock Installation and Use
- ATTACHING CAM
- Using CamLock
- Powering lock with a dead battery
- FCC Statement
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
MTI 2 Keyed Alike Tubular Cam Lock 5/8 Inch Camper
WHAT IN THE BOX
Not included
BATTERY
Battery Caution
Do not ingest the battery, Chemical Burn Hazard. Keep new and used batteries
away from children. The product contains a lithium coin/button cell battery.
If the coin/button cell battery is swallowed, it can cause severe internal
burns in just 2 hours and can lead to death. If you think batteries might have
been swallowed or placed inside any part of the body, seek immediate medical
attention. If the battery compartment does not close securely, stop using the
product and keep it away from children.
CAUTION
Risk of fire or explosion if the battery is replaced by an incorrect type.
- battery type: CR 2477 (non-rechargeable)
- chemical system of the battery: Lithium
KEY REGISTRATION (Standard Mode) – Complete Before Installation
- Swipe the Authorization card to enter enrollment mode. You will hear a double beep tone, indicating enrollment mode has been entered.
- Swipe each User card to lock. A double-beep tone indicates a card is now enrolled. Repeat for each user card, up to 250 user cards. If a card fails to be recognized, the lock will emit 4 fast beeps.
- Swipe the Authorization card again to close enrollment mode. Enrollment mode times out after 3 minutes of no activity. The lock will emit 4 fast beeps when enrollment has timed out.
NETWORK MODE – Versa EX or Managed Access
- Insert Intellikey into Connect® hub. After 10 seconds, the System Status LED will be flashing blue, indicating it is in pairing mode. It will automatically time out after 15 minutes.
- Swipe Pairing card to lock. Lock will start slowly beeping confirming it is looking for the Connect® network. Upon successfully pairing the lock will emit a double beep. Lock will automatically download key whitelist from network.
Full Connect Hub programming can be found in guide 063-00210
- Place Pairing Card over the RFID icon to place Versa EX in pairing mode. LED will be flashing blue.
- Swipe Pairing card to lock. Lock will start slowly beeping confirming it is looking for Versa EX network. Upon successfully pairing the lock will emit a double beep. Lock will automatically download key whitelist from Versa EX.
CAM Lock Installation and Use
- Determine if the lock will be mounted vertically or horizontally. Now is time to determine if CAM will contact the edge, or the top of the fixture when in the locked position. Steps assume horizontal mounting.
- Measure setback from side and top edge based on where the selected cam will engage with the fixture. Cam may extend past the edge of the door or sit even. Some fixtures may have a pocket cam engaged into, or it may engage with an internal bracket. Once location is determined, mark the center location for the hole.
- Drill 3/4 inch (19m) hole. Ensure hole is drilled square to the surface of the door.
- Clean the surface of the door with an alcohol wipe, in the area where lock will contact. Allow to dry thoroughly.
- Peel red liner from VHB tape
- Apply lock to door, ensuring it is straight. Apply pressure to VHB for 10 seconds to ensure complete adhesion.
- Attach large nut to threaded bushing on inside of door.
- Tighten nut with wrench until nut is firmly in place.
Do Not overtighten nut to avoid damaging door surface
ATTACHING CAM
- Pocket location for Cam is determined by max distance vs door thickness. Door thickness may determine pocket depth (C) Straight or offset Cams may be used to accommodate different engagement depths. If there is no pocket, a small metal bracket (not included) can be installed to the correct depth.
- Slide the Cam adapter onto the CamLock shaft. It will engage with the mating square “keyway”.
- Attach CAM to Camshaft with phillips screw and serrated washer with No 2 screwdriver. Check to ensure Cam is oriented in the correct lock/unlocked position before tightening screw.
Using CamLock
- Swipe Versa User Card on lock. The lock will emit a double beep if the card is accepted. The motor will cycle to unlock the state.
- User manually unlocks the lock by twisting knob.
- When finished, close door and twist lock to the locked position. The lock will emit a single beep when it is locked. If lock is not returned to locked position, it will start alarming after 5 minutes of being unlocked
Correct Disposal of Product
This marking indicates that this product should not be disposed with other
household wastes throughout the EU. To prevent harm to the environment or
human health from uncontrolled waste disposal, recycle it responsibly to
promote the sustainable reuse of material resources. To dispose of used
devices contact MTI Global Services Contact Center at
503-648-6500 or contact local recycling
company for proper recycling instructions for electronic devices.
Powering lock with a dead battery
- Flip up the dust cover on the power port.
- Insert USB-C from 5V USB-C power supply or external battery pack. We recommend MTI P/N 400-00186.
- Upon powering up, wait 10 seconds to initialize lock. Swipe RFID card. Twist lock to unlock normally.
- Leave battery plugged in until you have re-locked the door. Replace the battery as soon as possible.
FCC Statement
- FCC ID: 2AA2X-15000333
- Model: CamLock
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. Caution: If any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. The grantee is not responsible for any changes or modifications not expressly approved by the party responsible for compliance. Such modifications could void the user’s authority to operate the equipment. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. This equipment should be installed and operated with a minimum distance of 2 centimeters between the radiator and your body.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, under part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used following the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
IC: 24439-15000333
Model: Camlock
ISED Statement
This device contains licence-exempt transmitter(s)/receiver(s) that comply
with Innovation, Science and Economic Development Canada’s license-exempt
RSS(s). Operation is subject to the following two conditions:
- This device may not cause interference.
- This device must accept any interference, including interference that may cause undesired operation of the device.
CAN ICES-3(B)/NMB-3(B)
The device meets the exemption from the routine evaluation limits in section
2.5 of RSS 102 and compliance with RSS-102 RF exposure, users can obtain
Canadian information on RF exposure and compliance.
- www.mobiletechinc.com
- T:800.426.6844
- MTI P/N 063-00431 rev A ©2023 MTI All Rights Reserved
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>