APTOOK OL-R190B Commercial Dehumidifier with Pump Instruction Manual

June 15, 2024
APTOOK

APTOOK OL-R190B Commercial Dehumidifier with Pump

Specifications

  • Model No.: OL-R190B
  • Dehumidifier Voltage & Hertz: AC115V / 60Hz
  • Power Consumption & Current: 735W/6.8A @80, 60% RH, 900W/8.4A @86, 80% RH
  • Refrigerant Charge Dehumidify Capacity: R410a/19.8oz
  • Dehumidify Capacity: 90 Pints/Day @80, 60% RH, 190 Pints/Day @95, 80% RH
  • Maximum Design Pressure: High Side: 522psig (3.6MPa), Low Side: 240psig (1.65MPa)
  • BCSC Compressor Input Fan Motor Power: 15A RLA: 7.3A LRA:36.4A, 0.107HP

INSTRUCTIONS

Thank you for choosing the dehumidifier by APTOOK!

  • We hope it will bring great convenience to your work and life. We recommend that you save the user manual properly for future reference. Before using this product, please read the user manual carefully to ensure that this product functions at its best.
  • The APTOOK’s dehumidifier adopts an upgraded design, compact structure, easy to operate, and other characteristics, widely used in scientific research, sanitation, commodity storage, underground engineering, and dehumidification in high humidity places such as kitchens, bathrooms, archives, warehouses, etc. Can be effectively avoided if telecommunications equipment, materials, etc, are damaged due to dampness or rust.
  • A dehumidifier reduces humidity in enclosed environments by removing water vapor from the air. The APTOOK R190B is ideal for crawlspace drying, humidity control, and other applications.

Transportation and Custody

  • During transportation, this product should be handled preciously to prevent violent vibration. Generally, the packaged product should not be stored in the open air for a long time. It should be placed in a well-ventilated, non-corrosive gas warehouse.
  • It should not be placed upside down. Set the unit upright, Always store, transport, and use the unit in a horizontal position. If the unit is ever placed in a vertical position, return it to the horizontal position and let it stand for at least 24 hours before turning it on. Rainproof measures should be adopted when stored temporarily.
  • For best results, operate your dehumidifiers in an enclosed area.
  • Place your dehumidifier away from obstructions, and keep it away from anything that could block airflow into and out of the unit.
  • We also kindly ask you to take a few minutes to register your product at: www.aptook.com for more efficient support.

We are always just an email away
To access customer support, please email support@aptook.com with your purchase order ID to help us address the problem further and serve you better.

BEFORE YOU BEGIN

  • The information contained herein is subject to change without notice.
  • The user manual contains instructions and notes on the operation and use of this unit.
  • APTOOK recommends that you use genuine accessories from APTOOK.
  • APTOOK shall not be responsible for any damage or expense that might result from the use of parts other than genuine parts from the APTOOK.
  • Do not use unofficial components or accessories that may result in a risk of fire, electric shock, or injury to persons. If you need to replace any components or accessories, please visit official APTOOK channels to check relevant information.
  • For your safety and benefit, please read carefully before using and keep it handy for future reference.

IMPORTANT SAFETY TIPS

Before using the product, for safe and correct operation and maintenance, please read and understand the following safety tips

  1. Unplug the power supply before cleaning or storing the machine.
  2. Never immerse the machine in water or other liquids.
  3. Do not put the machine close to heat-generating devices, including flammable or dangerous materials.
  4. Do not put fingers or other items into the air inlet or air outlet.
  5. Do not sit, stand or put heavy objects on the machine.
  6. Never operate the machine when the power cord or plug is damaged. This may cause damage or injury. Please contact your local distributor for service issues.
  7. This appliance should only be used by adults who have read the manual and understand the operating procedure of the unit.
  8. The appliance is not to be used by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge unless they have been given supervision or instruction by an adult.
  9. Install the machine on a flat surface to minimize vibration and or noise.
  10. Never insert any other objects into the machine body.
  11. If the supply cord is damaged, it must be replaced by the distributor or qualified electrician.

warning: Never repair or remove the plug and or power cord. Any repairs should be completed by a qualified electrician or distributor.

SPECIFICATIONS

FEATURES

  • Hot Gas Valve system for fast defrost
  • Easy to assemble and disassemble the housing for repair
  • With a fast connector of hose, convenient for assembly and disassembling
  • Foldable handle,easy to operate
  • Quick pump access in front for easy servicing
  • Tough semi-pneumatic wheel

PRODUCT OVERVIEW

Parts Diagram

OPERATION

Control Panel Guide

Power Button: When the machine is in standby mode, the display screen will be displayed in a low-light LED. To start the dehumidifier, press the power button. Concurrently, the display screen will light up and the unit will run in Auto mode, the default humidity setting data is 10% RH, and the machine will start if the humidity condition meets the requirement of compressor operation.

Timing Button: Press the timing button, and the display screen will show the current timing data, and then press the Add button to increase the timing data or press the Minus button to decrease the timing data. Press one time to increase or decrease one hour. The timing indicator will light up after setting. When the machine is in standby mode, press the timing button to set the start-up time; when the machine is running, press it to set the shutdown time. The timing setting range is from 0 to 24 hours. If you set the timing data as “00”, it will cancel the timing function, and the timing indicator will turn off.

Add Button: Press the Add button to increase humidity data or increase timing data. When setting the humidity data, press the button one time to increase 5% RH, you can set the humidity range from 10%-90% RH, and 5% RH for one step , Add Button: Press the Add button to increase humidity data or increase timing data. When setting the humidity data, press the button one time to increase 5%RH, you can set the humidity range from 10%-90% RH, and 5% RH for one step,

Minus Button: Press the Minus button to decrease humidity data or decrease timing data. When setting the humidity data, press the button one time to decrease 5% RH, you can set the humidity range from 90%-10% RH, and 5% RH for one step, it will cycle as below 90%-85%-80%-75%-70%-65%-60%-55%-50%-45%-40%-35%-30%- 25%-20%-15%-10%-90% …When setting the timing data, press the button for one time to decrease 1 hour, it will cycle as below:24-23-22-21-20…-02-01-00-24-23…

Purge Button (Manual Drainage): Press and hold the purge button for 3 seconds, the machine will drain the water automatically by the built-in pump. After 30 seconds, the pump stops draining, then the indicator will turn off.

Defrosting Indicator: When the machine is defrosting, this indicator turns on. After defrosting, it turns off.
Water Full Indicator: When the water pump is full of water, the indicator light turns on to remind the user to drain.

Display Screen: T he default temperature display is Fahrenheit temperature. When the machine is in standby mode, press the power button for 5 seconds to switch to Celsius temperature. When the machine is running, it shows the temperature and humidity of the inlet air and outlet air.

It displays the running time when it is in running mode; and displays the setting timing and setting humidity data when users set.
Memory Function: If there is a power outage or the unit shuts off, it will auto restart to its original settings except timing, once power is restored.

Note: When the humidity of the air inlet ≥ setting humidity data +3%RH, and the compressor is out of 3 minutes delay start protection, the fan will start immediately and the compressor will start in 3 seconds later. When the humidity of the air inlet ≤ setting humidity data -3%RH, the compressor will stop working immediately, and the fan will stop working in 1 minute later.

AUTO DRAINAGE &MAINTENANCE

warning: Please disconnect the power supply before cleaning or conducting maintenance.

Cleaning: Clean the unit body with a soft damp cloth. Do not submerse or place water on the unit or control panel. Water may damage the electronic components of the unit.
Do not use chemical solvents such as benzene, alcohol, gasoline, or other heavy-duty cleaner. The surface may become damaged or deformed.

Cleaning the Air Filter:

  • Step 1: Pull out the air filter gently.
  • Step 2: Use a vacuum cleaner to remove the dirt on the surface of the air filter. If the air filter is exceptionally dirty, immerse it gently into warm water (about 40℃) with a neutral detergent, rinse and dry it thoroughly.
  • Step 3: Insert the filter back into the unit.

Dehumidifier Storage:

  1. Push the purge button to empty the water before transportation or storage.
  2. Transport and store the machine upright.
  3. Stack machines in the warehouse to save space.

Cautions: If the unit malfunctions turn off the unit and unplug it immediately. Please contact your distributor for service issues.
Do not dispose of electrical appliances in local landfills or municipal waste locations. Many parts are recyclable. Contact your local government for information regarding the collection systems available in your area.

PARTS LIST

TROUBLE SHOOTING GUIDE

Error prompt and code running status

  1. “E1” code: This code appears when the copper head sensor is damaged. The machine will keep running, but every 30 minutes, the compressor will stop for about 10 minutes, and then continue to run. After that, the machine will repeat the cycle like this.

  2. “E2” code: This code appears when the temperature and humidity sensor is damaged.
    The machine will keep running, but every 30 minutes, the compressor will stop for about 10 minutes, and then continue to run. After that, the machine will repeat the cycle like this.

  3. “E4” code: This code appears when the water tank of the water pump is full or failure of the water pump, the machine will stop running.

SAFETY PRECAUTIONS

  1. When using, do not place the dehumidifier on soft, uneven ground to avoid vibration or movement.
  2. Do not use thin rods or hard
  3. When using, please keep the objects to insert into the fuselage to dehumidifier away from heat sources avoid malfunction or danger. such as heaters and electric kettles to save electricity.
  4. When using, please close the doors and windows to achieve the host dehumidification effect
  5. Do not place items before and after the
  6. In case of power failure or dehumidifier. if the ventilation is blocked, the dehumidification effect will be affected long-term non-use, please unplug the power cord.
  7. When cleaning the dehumidifier, gently
  8. Do not place any objects on the
  9. Please clean the filter every two wipe it with a damp cloth, do not directly dehumidifier. weeks (do not use hot water above spray water to clean it. 104°F/40°C, alcohol, gasoline, or toluene).
  10. During continuous drainage, the
  11. After the filter is cleaned, please do
  12. Before moving or carrying the drainage pipe must be placed horizontally not place it in direct sunlight to dry it dehumidifier, please pour out the or downwards, and must not be uneven to avoid deformation. accumulated water in the water or entangled. tank

CUSTOMER SERVICE

APTOOK offers a limited 1-year free warranty on this OL-R190B dehumidifier, with original proof of purchase(typically you may only request to offer the order number or other information to prove a genuine purchase, instead of an invoice) and where a defect has arisen, wholly or substantially, as a result of faulty manufacture, parts or workmanship during the warranty period. During the warranty period, for the damaged part, we will provide a replacement part if it can be restored to normal use by replacing parts.
The warranty does not apply where damage is caused by other factors, including without limitation:

  • Normal wear and tear;
  • Abuse, mishandling, accident, or failure to follow operating instructions;
  • Exposure to liquid or infiltration of foreign particles;
  • Servicing or modifications of the product other than by APTOOK.

We will try our best to inspect the dehumidifier through photos or videos to troubleshoot and ensure that we can better solve the problem for you.
These are our general terms for warranty service, but we always urge our customers to reach out to us with any issue, regardless of warranty terms.

If you have an issue with a Lienuis product, please contact us at support@aptook.com, and we will do our best to resolve it for you.
Email: support@aptook.com

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals