GoKWh 12V and 24VLifepo4 Battery Smart Bluetooth User Manual
- June 15, 2024
- GoKWh
Table of Contents
- Important Safety Instructions
- Product Overview
- Specification
- Battery Connection
- Preparation
- Inspection
- Cable Sizing
- Battery Terminal
- Connecting Batteries in Banks
- Battery Charging
- Battery Storage
- Troubleshooting
- Bluetooth Setting
- Function Introduction
- APP User Guide
- My Interface
- Warranty
- 5-Year Warranty for After-Sales Service
- Customer Support
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
GoKWh 12V and 24VLifepo4 Battery Smart Bluetooth
Important Safety Instructions
DISCLAIMER
Please read all specifications, usage, storage conditions, and warnings on
this document before use. Always adhere to our handling and usage directions
for this battery pack. Misuse of batteries can cause the battery to
malfunction, degrade and reduce its capacity or life expectancy, overheat,
explode, or become a fire hazard. Customers are responsible for the proper use
and storage of this battery pack which is outlined on this document. If at any
point, the battery excessively overheats, leaks, etc, or does not function as
stated, or is visibly damaged; DO NOT USE.
Please contact our support team for further assistance.
We do not bear responsibility for any damages caused by the misuse of this
battery accidental or otherwise
WARNINGS
- DO NOT immerse the battery in water or allow it to get wet.
- DO NOT use or store the battery near sources of heat such as a fire or heater.
- DO NOT reverse the positive (+) and negative (-) terminals.
- DO NOT connect the battery directly to wall outlets or car cigarette-lighter sockets without proper charging equipment. DO NOT allow exposed ends of cables connected to opposite terminals to touch.
- DO NOT put the battery into a fire or apply direct heat.
- DO NOT use the battery if the battery casing has been pierced, broken, cracked, or otherwise visibly damaged. DO NOT forcibly open the battery casing for any reason.
- Avoid severe physical shock. Do not throw the battery or heavily strike the battery in any way. Do not put excessive pressure or step on the battery.
- Never solder anything directly to the battery terminals.
- DO NOT attempt to disassemble or modify the battery in any way.
- DO NOT place the battery in a microwave oven or pressurized container.
Product Overview
Battery Dimensions:
Terminal Size:
M8 (1.25 mm Metric Thread)
Post Bolts :
M8 (1.25 mm Metric Thread ” 16mm Bolt Length)
( The bolts can be replaced with M8 bolts of other lengths based on actual
needs)
Specification
Model|
12V100AH
|
12V200AH
|
24V100AH
---|---|---|---
Basial|
Cell Type| Life PO4( LFP)
Dimensions| L13.19 W7.28 H8.46 L335 W185 H215mm| L20.55 W9.45 H8.46
L522 W240 H215mm| L20.55 W9.45 H.46 L522 W240* H215mm
Terminal Type Case Material| M8
| A BS ( Flame Retardant Plastic)
LCD Display| No
Warranty| 5 Year
Electrical
Nominal Voltage| 12.8 V| 25.6 V
Nominal Capacity Nominal Energy| 100 A h| 200 A h| 100 A h
Charge Method| 1280 Wh| 2560 Wh| 2560 Wh
| CC/CV
Recommend Charge Voltage| ≤ 14.6V| ≤ 29.2
Recommend Charge Current| ≤ 50A| ≤ 100A| ≤ 50A
Recommend Discharge Cut-off Voltage| ≥ 10V| ≥ 20V
Recommend Discharge Current| ≤ 100 A| ≤ 200 A| ≤ 100 A
Internal Resistance| ≤ 30 mΩ
Performance
Cycle Life| ≥ 4000 Cycles
Service Life| 10 Years
Protection| IP65, Built- in Bluetooth BMS
Temperature Range
Charge| 0~45°C (32~113°F)
Discharge| -20~60°C (-4~140°F)
Storage| -10~45°C (14~113°F)
Scalability
Parallel Connection| Up to 4P 12.8V 400 Ah | 5.12 kWh| Up to 4P 12.8V 800 Ah |
10.24kWh| Up to 4P 25.6V 400 Ah | 10.24 kWh
Series Connection| Up to 4S 51.2V 100 Ah | 5.12kWh| Up to 4S 51.2V 200 Ah |
10.24 kWh| Up to 4S 102.4V 100 Ah | 10.24 kWh
Battery Connection
Safe and reliable installation requires trained and certified technicians. Therefore, the purpose of this section is only to serve as a guideline as all scenarios cannot be covered.
Preparation
Before the installation and operation of the battery, it is recommended to have the following equipment or tools available:
- Proper Protective Equipment
- Insulated Tool(s)
- Multimeter
- Battery Cable
- Battery Charger / Charge Controller
Inspection
Please check for visible damage including cracks, dents, deformation, and other visible abnormalities. The top of the battery and terminal connections should be clean, free of dirt and corrosion, and dry. If any problems are detected with the battery, please contact us for assistance. Refer to the last page of the manual for contact information.
Cable Sizing
Battery cables (sold separately) should be appropriately sized to handle the
expected load.
Please refer to the following table for the ampacities of copper cables with
different gauge sizes.
Copper Cable Gauge Size (AWG/mm2) | Ampacity (A) |
---|---|
14 (2.08) | 20 |
12 (3.31) | 25 |
10 (5.25) | 35 |
8 (8.36) | 50 |
6 (13.3) | 65 |
4 (21.1) | 85 |
2 (33.6) | 115 |
1 (42.4) | 130 |
1/0 (53.5) | 150 |
2/0 (67.4) | 175 |
4/0 (107) | 230 |
The above values are from the NEC Table 310.15(B)16 for copper cables rated at 75°C (197°F), operating at an ambient temperature of no more than 30°C (86°F). Lengths in excess of 6 feet (1829 mm) may require heavier gauge cable to avoid excess voltage drop in undersized wiring.
Battery Terminal
The depths of the female battery terminal threads are no more than 12 mm. Consider this when determining the proper bolt length to secure bus bars, cable lugs, and any washers that will be affixed to the terminal connection pad. If too much torque is applied to a bolt, the female threads of the battery terminal will be stripped and the damage will not be covered under warranty due to misuse of the product. Consider the 12 mm thread depth when selecting your bolts so that they do not bottom-out. Conversely, a minimum of 3 threads must be engaged before applying 8 lb-ft of torque so as to not damage the threads.
Connecting Batteries in Banks
CAUTION
The batteries pack support max 4S or 4P, but in practical applications, consumers need to calculate based on their own load situation.
The maximum voltage after series and parallel connection of battery packs should less load voltage.
The load current should be less than the recommended current of the battery pack after series and parallel connection.
It is recommended to balance the voltage before using it in series or
parallel.
DO NOT string batteries with different chemistries, brands, models, rated
capacities, or nominal voltages in parallel.
In parallel battery banks, the cables between each battery should be of equal length to ensure that all batteries in the system can work equally together
The built-in BMS of the battery pack only protect and balance the internal battery cells. If the battery pack is connected in series or parallel, if you want to achieve better protection and balance, you can additionally install an external BMS control.
Connection In Series
- (Maximum of 4 Batteries)
- 12V50AH:48V(51.2V) 50Ah
- 12V100AH:48V(51.2V) 100Ah
- 12V200AH:48V(51.2V) 200Ah
- 24V100AH:96V(102.4V) 100Ah
Connection In Parallel
- (Maximum of 4 Batteries)
- 12V50AH:12V(12.8V) 200Ah
- 12V100AH:12V(12.8V) 400Ah
- 12V200AH:12V(12.8V) 800Ah
- 24V100AH:24V(25.6V) 400Ah
Battery Charging
LiFePO4 Batteries perform a 4-stage charging algorithm called “Constant
Current/Constant Voltage” (CC/CV).
The standard LiFePO4 profile is 0.2C CC charge to 14.2V, and then, CV at 14.4V
charge until the charge current declines to <=0.05C.
The recommended max. charging current for a 100Ah LiFePO4 battery is 50A
(0.5C). A faster charge of 100A (1C) may be used as necessary, however,
regularly charging your battery this way may shorten its life and subsequently
its total capacity due to the extra heat generated during this process.
We do not recommend using any other types of chargers for LiFePO4 batteries,
such as SLA and Gel chargers.
Battery Storage
Temperature
The battery can be operated at temperatures of -10~45°C (14~133°F), and a temperature between 10℃ to 35℃(50℉ to 95℉) is ideal for long-term storage. Store in a fireproof container and away from children.
Capacity
For a longer-lasting product, it is best to store your battery at a 50% charge level and recharge every three months if it is not going to be used for a long time.
Troubleshooting
If any problems occur during the battery operation, please refer to the following instructions or contact us for assistance.
Bluetooth Setting
Supports Android and IOS systems
Scan the code to jump to the download address, and follow the instructions to complete the download and installation.
Scan to download Xiaoxiang Electric App
Function Introduction
Module | Function | Describe | Example |
---|---|---|---|
History | Voltage , current , remaining capacity , temperature | Display |
the battery maximum , minimum average voltage , battery current , remaining
capacity , BMS board temperature change curve| The last 100 pieces of data ,
one per minute , Graph
| Charging switch , discharge| Issue commands through| Control switch
Control| Switch , automatic equalization switch , clear alarm , reset
capacity| the APP to control the BUS board : clear alarm data : reset
remaining capacity : open equalization| on / off : automatic equalization
switch ,clear alarm . reset capacity ls not displayed in some BMS versions
Real time| SOC display diagram , Estimated filling time , Estimated
release time , charging switch , Discharge switch , Equilibrium , Protection
status . total voltage , current , power , Maximum voltage ( single string
) , Minimum voltage single string ) , Average voltage , differential pressure
, Cycles , temperature ,humidity , Single String Voltage Information|
Dashboard , displaying battery voltage ,current , temperature ,SOC ,
protection status differential pressure cycle times and other data| Real-time
data of battery static ,charging and charging
Parameter| Basic information . initial settings| Display the basic
information of the protection board| Display BMS basic information ; initial
settings are not displayed in some BMS versions
Mine| Complete information unbundle equipment , use instructions for
lithium batteries , use instructions for BMS . about us , log out of account|
Display personal information and settings , Instructions for use . and
introduction to our Company , purchase channels . etc| Account information
manufacturer information , etc
APP User Guide
Operating Environment
Android version 5.0 / 10S version 10.0 or above , it can be used on devices that support Bluetooth 4.0 , and after obtaining the permission to use Bluetooth and GPS , it can run .
Login connection
Registering an Account
After the Xiaoxiang Electric APP is successfully installed , open the APP ,
allow Bluetooth to be turned on , and obtain location information , the APP
will automatic the account registration page pops up , please enter the mobile
phone number as required , set the password , and click Confirm when finished
APP physical display Figure 1
Bluetooth connect / disconnect
- Connect to Bluetooth : After successful login , the APP will jump to the Bluetooth list , select the Bluetooth that needs to be connected to connect
- Switch battery : When there are multiple batteries , you can check multiple Bluetooth names in the list , and quickly switch the battery to be connected on the real-time interface
- Scan code connection : In the upper right corner of the real-time interface , click the scan code button to connect directly by scanning the barcode of the Bluetooth module
- Search for Bluetooth : On the device list page , when there are multiple batteries , you can quickly find the battery that needs to be connected by searching for the Bluetooth name
- Disconnect Bluetooth : On the device list page , click Disconnect .
APP physical display Figure
Guest mode
when the mobile phone signal in the users environment is poor or the user needs to skip the account registration , they can choose to use the guest mode . Note that this mode cannot obtain the setting perms because the relogging account . To obtain the setting permission , you must log in to the account . Operation steps : Open the APP , enter the login interface , choose to log in later , and the APP will directly.
Real-time interface
- Capacity information: In static mode, only the percentage of battery SOC and remaining capacity are displayed: estimated battery level displayed during charging: estimated battery level displayed during discharge.
- Switch and protection status: The current status display of the charging and discharging switch: When the switch is open, it is open, otherwise it is closed: The balance status display shows that the balance is open, it is open, and vice versa: The protection status display shows that when the protection board triggers the protection threshold or manual control when charging and discharging, the protection status displays the corresponding protection status. When the protection status is not triggered, the status display is closed
- Battery information: total voltage, current, power, maximum voltage of a single battery, minimum voltage of a single battery, average voltage, voltage difference, number of cycles, read or calculated through the protection board, and the above data is displayed on the APP
- Temperature and humidity: The MOS temperature is the ambient temperature of the protective board, while the other temperatures are the external NIC temperature, and the temperature of the battery is detected. Humidity is the ambient humidity, which needs to be measured with a humidity probe to display.
- Single string voltage: Single string battery voltage, information collected by the detection board, high voltage displayed in green, middle value displayed as the highest voltage
Control interface
- Charging and discharging switch: Through the APP, you can directly control the opening or closing of the charging and discharging switch, and control the charging and discharging of the battery.
- Automatic balancing: Force the balancing function to be enabled. After successful switching, the real-time interface balance status will be displayed.
- Clear alarm: Clear alarm data
- Re s et capacity: Reassess the remaining capacity based on the current voltage value.
Guest mode
primary information | secondary information | Example |
---|---|---|
bluetooth name | Xiaoxiang Bms , modifiable | |
Basic Information | Serial number | Can be modified according to customer |
needs
Bar-code| Can be modified according to customer needs
battery model| Can be modified according to customer needs
battery manufacturer| DG , IBD , can be modified
BMS version number| 30 . read the BMS version . cannot be modified
BMS model| SP17S003 , read cannot be modified
Production Date| 2022-1-18 , read unmodifiable
BMS address| 24 digits , read and cannot be modified
Rated charging current| 20.0A . read cannot be modified
Rated discharge current| 19.0A . read unmodifiable
Rated shop power| 492W . read unmodifiable
Default setting| Nominal capacity| 10000mAH , can be modified
Cycle capacity| 8000mAH , can be modified
My Interface
Interface introduction
primary information | secondary information | Example |
---|---|---|
Complete material Device bound | Phone number | Phone number |
eman address | ||
Lithium battery notice | Bluetooth list | Unbind the device |
instructions for using BMS | Web Inks | Web links |
Web links | Web links | |
About Us Logout | Company Profile | company profiles |
The way of buying | Albaba . Taobao service hotline | |
Contact us | Official website link service hotline manufacturer address | |
Log out of current account | quit |
Bind / Unbind Device
When you forget your login password , You can reset a new password through your email . The steps are as follows :
- Open the login interface , find the forgotten password , click it , and the reset password interface will pop up ;
- Enter the corresponding binding email and click Send Verification Code . Generally , you will receive the verification code within 60S , pay attention to open the mailbox to check
- Enter the verification code , set a new password , and finally click OK
Warranty
All GoKWh 12V and 24V series LiFePO4 batteries come with 5-year manufacturer’s
defect warranty from the date of battery purchase.
This warranty covers the following 12V and 24V Series LiFePO4 battery models:
- Note : All batteries are fully tested before being shipped.
5-Year Warranty for After-Sales Service
Warranty is a guarantee against manufacturer defects only.
GoKWh warrants this battery to be free from manufacturer defects for 5 years. lf for some improbable circumstance the battery is defective, we will replace the battery. The following situation is not covered by the warranty:
- Batteries that have been poorly maintained, incorrectly charged, reversed polarity, improperly installed, stored and used in excessive heat, physical damage, fire, freezing, water damage, tampering, damage to terminals, failure to maintain proper battery charge or use in excess of rated charge/discharge cycles.
- Loss or damage due to force majeure or external causes, misuse, accident, negligence, unauthorized modification or repair.
- Warranties apply only to the original owner and are not transferable. We will verify your purchase before processing any warranty claims or returns.
- The buyer intentionally conceals or fails to cooperate in providing usage information. GoKWh has a team of technicians to provide technical support if needed. Proof of purchase and your usage will be requested. The customer is responsible for shipping costs. If we deem the product manufacturer defective, we will cover the replacement shipping costs.
Customer Support
hi@gokwh.com
+86-18566184618
gokwh.com
Puxin Road, Tangxia Town,Dongguan, Guangdong, China
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>