Culligan WH-HD200-C Whole House Water Filter System Instruction Manual

June 15, 2024
Culligan

Culligan WH-HD200-C Whole House Water Filter System Instruction Manual
Culligan WH-HD200-C Whole House Water Filter System

PARTS

INCLUDED:

  • Filter Housing
  • WR-HD Housing Wrench
  • BR-C Mounting Bracket
  • Filter Life Monitor
  • Timer Battery (Pre-Installed)

NOT INCLUDED:

  • Installation Fittings
  • Teflon® Tape

NOTE: Galvanized fittings must be used for installation on galvanized pipe.

SPECIFICATIONS

Pressure Range: 30–100 psi (2.1–6.9 bar)
Temperature Range: 40–100°F (4.4–37.7°C)

TOOLS REQUIRED

  • Pipe Cutter or Hacksaw

  • 2 Adjustable Wrenches

  • File

  • Pencil

OPTIONAL MATERIALS

SOLD SEPARATELY:

  • OR-250 Replacement O-Ring

PRECAUTIONS

WARNING: Do not use with water that is microbiologically unsafe or of unknown source/quality without adequate disinfection before or after the system.

CAUTION: Filter housing must be protected against freezing temperatures, frost, snow, sleet, and ice. Exposure to these elements can produce cracks and product failures.

CAUTION: The rubber O-Ring provides the water-tight seal between the filter head and the housing. It is important that the O-Ring be properly seated in the O-Ring groove or a water leak will occur.

CAUTION: This product has a limited service life. We recommend that a record be kept regarding the date of install and any other performed maintenance. In addition, the entire filter housing should be routinely inspected for signs of stress marks, cracking, chipping, warping, and discoloration. If this filtration system shows any of these signs of wear, the entire unit should be replaced immediately.

CAUTION: Clear housings may crack or warp over time causing failure and leakage if exposed to organic solvents, such as those found in aerosol sprays for cleaning products and insecticides.

  • For cold water use only. Do not use on hot water line or in areas where the temperature surrounding the unit exceeds 100°F.
  • Keep out of direct sunlight. UV rays can weaken the integrity of the filter housing, and also promotes ziological growth within the unit.
  • Make certain that installation complies with all state and local laws and regulations.
  • The contaminants or other substances removed or reduced by the selected cartridge are not necessarily in your water. Ask your local water municipality for a copy of their water analysis, or have your water tested by a reputable water testing lab.
  • After prolonged periods of non-use (such as during a vacation) it is recommended that the system be flushed thoroughly. Let water run for 5–6 minutes before using.
  • All filter cartridges recommended for use with this system carry a limited service life. Changes in taste, odor, color, and/or flow of the water being filtered indicate that the cartridge should be replaced.
  • Some harmless bacteria may attack cellulose media cartridges. If your cartridge seems to disintegrate or develops a musty or moldy odor, switch to a synthetic media cartridge or consult the manufacturer.

PARTS INCLUDED

PARTS INCLUDED
PARTS INCLUDED

INSTALLATION

  • Install filter after water meter or pressure tank.
  • Only Teflon® tape is recommended for fitting connections.
  • Instructions are for installing 1˝ compression fittings (separate fittings required for other sizes and non-copper pipe).
  1. Turn off water supply (A) and open nearest faucet to drain pipes before installation. Apply about 6˝ of Teflon® tape (B) in clockwise direction to pipe threads of each adapter.
    IMPORTANT: When choosing location allow 1-1/2˝– 2˝ clearance below housing to allow for filter changes.
    INSTALLATION

  2. If using optional BR-C mounting bracket, start by making sure the arrows facing you on the system are consistent with the direction of your water flow. If necessary, remove filter life indicator holder if on the back side of the unit, and move it to the front. Align the holes of the bracket withthe holes on the back of the filter head. Insert four mounting screws through the bracket and into the filter head until tight. Otherwise skip to step 3.
    INSTALLATION

  3. Assemble all fittings. Start adapters (not included) into filter head by hand. Use a wrench to tighten firmly.
    DO NOT OVER-TIGHTEN.
    INSTALLATION

  4. Measure overall length of configured system with adapters attached.
    Reduce this measurement enough to allow for full engagement of the pipe into the adapters and determine how much pipe to remove (X). Mark section of pipe to be removed.
    INSTALLATION

  5. Using a pipe cutter or hacksaw, cut and remove marked section of pipe. File or sand sharp edges on remaining pipe.
    INSTALLATION

  6. Slip brass compression nut and ferrule onto each end of 1˝ pipe.
    INSTALLATION

  7. Align filter assembly with ends of pipe, making certain your water flow is in the same direction as the arrows on your filter head. It will be necessary to spread ends of pipe apart to install filter assembly. Using two adjustable wrenches, hold incoming fitting securely with one wrench and tighten nut with second wrench. Repeat process for outgoing fitting.INSTALLATION

  8. CAUTION: If water pipes are used to ground electrical systems, appliances or phones, be certain to install a jumper wire
    INSTALLATION

  9. If using optional mounting bracket attach it to the wall using four mounting screws (not included)
    INSTALLATION

  10. Ensure the filter housing has been properly tightened using the housing wrench provided.
    Turn bypass valve to “Filter” mode using wrench, then slowly turn on main water supply.
    Slowly press red pressure-relief button on top of filter to release trapped air. Check for leaks.
    Open nearest faucet and flush filter cartridge for 10 minutes.
    Reset filter life indicator (hold reset button for 2 seconds).
    INSTALLATION

FILTER CARTRIDGE REPLACEMENT

  1. Turn water off by rotating bypass valve to “Off” or “Bypass.”
    NOTE: Turning bypass to “Off” will shut off all water flow within the household.
    Press red pressure-relief button to relieve pressure. Unscrew bottom of housing. Remove O-Ring from groove in housing and wipe clean and set aside. Discard used cartridge. Rinse out housing and fill 1/3 with water.
    Add 2 tablespoons of bleach and scrub with nonabrasive brush or sponge. Rinse thoroughly.
    INSTALLATION

  2. Lubricate O-Ring with a coating of clean food-grade silicone grease. Insert O-Ring back into groove and smooth into place with finger.
    NOTE: This step is important to ensure proper housing seal. Make certain O-Ring is seated level in the groove.
    Insert new cartridge into housing. Make certain it slips over the standpipe at the bottom of the housing.
    INSTALLATION

  3. Screw the bottom of housing onto the cap until tight. DO NOT OVER-TIGHTEN. Make certain standpipe in filter head slips into cartridge.
    Slowly turn bypass valve to “Filter” to allow system to fill with water. Slowly press red pressure-relief button to release trapped air. Check for leaks. Reset filter life indicator (hold reset button for 2 seconds).
    NOTE: Flush filter cartridge for 10 minutes before use.
    INSTALLATION

TIMER APPLICATION INSTRUCTIONS AND BATTERY REPLACEMENT

APPLICATION AND RESET

After new battery is installed or filter is changed, push and hold the filter life reset button for approximately 2 seconds until green light flashes. The light will flash red in 90 days to remind you that it is time to change the filter.

BATTERY REPLACEMENT

  1. Insert small screwdriver on the base of the indicator holder to remove it from the housing.
  2. Insert small screwdriver on the bottom flat side of the filter life indicator. Gently pry open and separate timer base from cap.
  3. Carefully remove the circuit board and slide old battery out of holder. Change battery (#2032).
  4. Carefully line up and place circuit board back into housing.
  5. Line up the base and cap and snap back together. Place indicator back into housing.
  6. Reset filter life indicator to start timer (hold reset button for 2 seconds). It is recommended that you change the battery every year to ensure your indicator works properly

TROUBLESHOOTING

LEAKS BETWEEN FILTER HEAD AND HOUSING:

  1. Turn off water supply and press the red pressure-relief button. Remove bottom of housing.
  2. Clean O-Ring and O-Ring groove (located directly beneath threads of housing). Lubricate O-Ring with clean silicone grease and replace securely into groove. Screw housing into filter head and hand-tighten. DO NOT OVER-TIGHTEN.

LEAKS FROM INLET/OUTLET CONNECTIONS:

  1. Turn off water supply. For brass fittings, tighten nut snugly about 1/2-turn with a wrench.
  2. Turn on water supply. If leaks persist, or if there are other leaks on system, turn off water supply. Call Technical Support at 1-800-721-7360.

FILTER CARTRIDGE SELECTION GUIDE

FILTER SELECTION GUIDE

**** Select the right cartridge for your water| R50-BBSA1| CW25-BBS1| CP5-BBS1| CW5-BBS1| *RFC-BBS1A
PROBLEMS| | | | |
Sediment †| | | | |
Rust †|
| | | |
Scale †| | | | |
Dirt †|
| | | |
Coarse Sand †| | | | |
Sand †| |
| | |
Fine Sand †| | |
| |
Silt †| | | | |
Bad Taste & Odor †| | | | |

Aesthetic Chlorine Taste & Odor †| | | | | ***
Cartridge Life
†| 6 months24,000 gallons| 5 months20,000 gallons| 3 months12,000 gallons| 4 months16,000 gallons| 6 months10,000 gallons
Micron Rating
†| 50| 25| 5| 5| 25
Cartridge Material| Pleated Polyester| Wound Polypropylene| Pleated Cellulose| Wound Polypropylene| Granular-Activated Carbon
Recommended for Well Water| | | | |

  • Cartridge life varies depending on filter type, usage and water conditions (one month = approximately 4000 gallons).b
  • The smaller the micron rating, the smaller the size particle thecartridge will filter. For comparison purposes, the human hair has a diameter of approximately 70 microns. Particles smaller than 40 microns are not visible to the human eye.
  1. R50-BBSA, CW25-BBS, CP5-BBS, CW5-BBS and RFC-BBSA are not certified by WQA.
  2. Not Performance Tested or Certified by WQA.

TWO-YEAR LIMITED WARRANTY: WH-HD200-C

This warranty applies to the Filter Housing. It does NOT apply to any disposable filter cartridge where life expectancy varies with the water being filtered. This warranty covers defects in material and workmanship only for 2 full years from the original date of delivery. Culligan will replace any part which in Mulligan’s opinion is defective, unless: (1) any part of the unit has been subjected to any type of tampering, alteration, or improper use after delivery, or (2) it has been repaired by anyone not approved by Mulligan. Mulligan is not responsible for damage in transit, and claims for such damage should be presented to the carrier by the customer. This warranty does not cover any labor, transportation, or shipping expenses incurred. The hiring of any individual or service to install or maintain this product is done at the discretion and expense of the purchaser.

This product has been designed solely for use as a housing for a disposable filter cartridge. It is NOT warranted against freezing, and neither this product nor its parts is warranted against defects or deterioration caused by uses for which this product was not expressly intended.

THE FOREGOING WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED, WHETHER ORAL OR ARISING BY USAGE OF TRADE OR COURSE OF DEALING, INCLUDING, WITHOUT LIMITATION, ANY WARRANTIES OF FITNESS OR MERCHANTABILITY. THIS WARRANTY IS THE PURCHASER’S SOLE AND EXCLUSIVE REMEDY, IN NO EVENT SHALL CULLIGAN BE LIABLE FOR ANY ANTICIPATED OR LOST PROFITS, INCIDENTAL DAMAGES, CONSEQUENTIAL DAMAGES, COSTS, TIME CHARGES OR OTHER LOSSES, WHETHER BASED ON BREACH OF CONTRACT, TORTIOUS CONDUCT OR
ANY OTHER THEORY, INCURRED IN CONNECTION WITH THE PURCHASE, INSTALLATION, REPAIR OR
OPERATION OF THIS PRODUCT. CULLIGAN DOES NOT AUTHORIZE ANYONE TO ASSUME FOR IT ANY LIABILITY OR TO MAKE ON ITS BEHALF ANY ADDITIONAL WARRANTIES IN CONNECTION WITH THE FILTER HOUSING OR ANY PART THEREOF.

For servicing under this warranty, return any defective part to YOUR RETAILER within the 2 year period referred to above. Be sure that you complete the online warranty registration within 30 days of purchase and keep your original receipt, order form, or bill of sale to serve as a proof of purchase before returning.

PRODUCT REGISTRATION

Please be sure to go online within 30 days of purchase and register your product at www.register.culligan.com

THE WH-HD200-C HOUSING HAS BEEN TESTED AND CERTIFIED BY WQA AGAINST NSF/ ANSI 372 FOR LOW LEAD COMPLIANCE, CSA B483.1 AND NSF/ANSI 42 FOR MATERIAL SAFETY AND STRUCTURAL INTEGRITY. NOT CERTIFIED FOR CONTAMINANT REDUCTION.

Culligan International Company
Rosemont, Illinois 60018
www.culligan.com

Technical Support M–F 8:00AM–4:30PM (CST)
Servicio de soporte técnico disponible de lunes a viernes, de 8:00 A.M. a 4:30 P.M. (CST)
Soutien technique L–V 8 H à 16 H 30 (HNC)

1-800-721-7360

©2020 Culligan International Company
Rev. B 02/20 01028006/01027421-01027422

Company logo

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals