MClimate T-Valve Lorawan Instruction Manual
- June 15, 2024
- MClimate
Table of Contents
MClimate T-Valve LoRaWAN®
User manual
T-Valve Lorawan
Scan the QR Code to access MClimate T-Valve LoRaWAN® extended documentation
Need some help?
For more product information and issues related to it, visit: mclimate.eu
/lorawan-resources
or write us to: lorawan-support@mclimate.eu
00359 800 3 1010
Monday-Friday 09:00 – 18:00
Sofia, Bulgaria
Aleksandar Malinov Boulevard 31, Campus X, Building 2, floor 1, office 1-2
What’s inside the box?
Technical specifications
T-Valve is a smart LoRaWAN® water valve used in residential or commercial buildings. 3/4″ and 1″1/4 versions available, certified for Drinking Water. It has 10 years of battery life calculated with daily on/offs. It also measures water and environment temperature. It has multiple tamper protection mechanisms – tracking magnetic interference and if the device is being physically abused. Optionally a wired flood sensor and external power supply can be installed. T-Valve gives you the opportunity to stop potential water damage from happening, by being able to control the main water supply in your property from a distance. No more floods and damages.
Description: Smart LoRaWAN® water valve
Model: MC-LW-T-VALVE-01
Dimensions: 105 x 117 x 98mm
Weight: 600gr
Frequency range: 863÷870MHz
LoRaWAN® Device type: Class A End-device
Power supply: built-in battery: LiSOCl2 ER26500 3.6V 9000mAh
External power supply: 9VDC
Sensors: 1xWater Temperature Sensor, 1xAmbient Temperature sensor,
1xMagnetic field sensor, 1xWired flood sensor (optional)
Work temperature: 0°С to +60°С
IP protection: IP68
Material: PC/ABS; Valve PPE/PS
Environmental conditions, in which the device is intended to operate:
- Indoor using;
- for altitude up to 2000m;
- for an ambient temperature:0°С to +60°С;
- for maximum relative humidity of 80% for temperature up to 31°С, decreasing linearly to 25% relative humidity at temperature 50°С;
- for environment with a degree of contamination 2 (PD2).
Storage and transportation conditions:
- for an ambient temperature :-40°С to +85°С;
- for relative humidity 5% to 90% without condensation
Manufacturer
Melissa Climate Jsc
Gen. Gurko 4 street
1000 Sofia,Bulgaria
Safety Instructions
Failure to follow the recommended instructions in this manual may be dangerous or be in violation of the law. The manufacturer Melissa Climate Plc., Is not responsible for any loss or damage caused by failure to follow the instructions in the operating instructions. The installation and connection of the device to the power supply must be carried out in accordance with the national electrical installation legislation.
Legal Notices
All information, including but not limited to, features, functionality, and / or other product specifications are subject to change without notice. MClimate retains all rights to review or update its products, software or documentation without being required to notify any natural or legal person.
The MClimate and MClimate logo are trademarks of Melissa Climate Jsc. All other brands and product names mentioned herein are trademarks of their respective owners.
EU Declaration of Conformity
This device complies with the essential requirements and other applicable
provisions of the following EU directives:
2014/53/ЕС
EN 50491-3:2009
EEU 300 220-1 V3.1.1:2017
EEU 300 220-2 V3.1.1:2017
EN 60950-1:2006+A11:2009 +A1:2010+A12:2011+ А2:2013 + AC:2015
EN 301 489-1 V2.1.1:2017
Compliance with the WEEE Directive
The appliance marked with this symbol should not be disposed of with other
household waste. It must be handed over to the relevant collection point for
the recycling of waste electrical and electronic equipment.
Compatibility
In order to operate MCllimate T-Valve
LoRaWAN®, you will need:
LoRaWAN® network
Battery type: built-in battery: LiSOCl2
ER26500 3.6V 9000mAh
Device operating voltage: 2.7 – 3.6VDC
Device parts
Commissioning
-
Open your LoRaWAN® Network provider access panel and add the device using the supplied Serial Number, DevEUI, AppEUI (JoinEUI) and AppKey. **** The data is example. Do not use.
-
Continue the Installation with the instructions of your LoRaWAN® Network provider. You can get DevEUI, AppEUI (JoinEUI) & AppKey information from the LoRaWAN® credentials .csv file we sent you with the fulfillment confirmation.
-
Out of the factory, T-Valve comes in deep-sleep mode and it has to be initially activated in order to start normal operation. In deep-sleep mode the device is not transmitting or receiving any data in order to preserve the battery before being installed.
In order to activate T-Valve, press the OK button 5 times quickly. -
If T-Valve is NOT connected to a network, when one presses the OK button, an alternating animation of the Flood, Leak, CLOSE & OPEN LEDs will be shown. Once the device has received Join Accept from the LoRaWAN® Network, it will not show the above-described animation. Instead, if one presses the OK button, the LED of the corresponding valve state will be activated shortly – e.g. OPEN LED or CLOSE LED.
LEDs and behaviour
On the side, you can see an illustration of T-Valve’s LEDs and buttons. The LEDs have the following purpose:
# | Name | Purpose |
---|---|---|
1 | OPEN | Activates when one presses the OPEN button or the OK button and the |
valve is currently open.
2| CLOSE| Activates when one presses the CLOSE button or the OK button and the
valve is currently closed.
3| Leak| Activated through a downlink command indicating the customer there’s
a small leakage detected in the system. T-Valve DOES NOT detect small leakages
itself.
4| Flood| Activated in case a wired flood sensor is installed and a flood is
detected.
Warning: Opening and closing the valve uses a lot of current. If you press the buttons OPEN and CLOSE fast consecutively, T-Valve may indicate that there’s not enough to perform the desired action. Inside, a large capacitor is charged, which takes approx 1s to recharge. If you try to OPEN or CLOSE the T-Valve and this capacitor is not yet fully charged, the OPEN or CLOSE LED will blink 3 times.
Optional installation of external accessories
T-Valve offers optional installation of a wired flood sensor, which can close
the water supply immediately after sensing a flood. T-Valve also offers
optional external power supply installation. The power supply DOES NOT charge
the battery inside T-Valve. In order to install an accessory, you will need
an appropriately IP-rated cable-gland, which can be supplied by MClimate.
In order to install a cable-gland, one has to first press with a screw-driver
the openings on the bottom of T-Valve and remove the excess plastic. Whichever
cut-hole can be used for the installation of the cable-gland. If required, two
cable-glands can be used.
In order to install the cable-gland, one must disassemble the device using the four Phillips screws. If the device is connected to a network, the anti-tamper protection will be activated and the device will signal in the uplink that the device is opened.
Optional installation of external accessories
a. Installation of a wired flood sensor
The wired flood sensor can detect whether a cable is broken or cut. Feed the
connector through the cable-gland and install it on T-Valve PCB as described
in the picture below.
Optional installation of external accessories
a. Installation of external power supply
The external power supply is also fed through a cable-gland and installed on the T-Valve PCB according to the picture below.
Pwr and GND pins from P10 connector.
Pwr pin voltage range: 5-9Vdc
www.mclimate.eu
Designed & Manufactured by MClimate in Europe.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>