NICE B07JPZ171H Ankle Wrap
VIDEO INSTRUCTIONS
Please Visit
nicerecovery.com/how-to-videos
WRAP GUIDE SIZING
Small/Medium
Fits average body types ~up to 5’10 170lbs; up to shoe size 10M/12W Shoe Size
Large/XL
Fits average body types above 5’10 170lbs; shoe size above 10M+/Size 12W+
WRAP CARE
To clean inside, use anti-bacterial isopropyl alcohol wipe, to wipe down blue
material. For the outside, feel free to use a lint roller for removing any pet
hair, dander, or debris. Do NOT machine wash or dry clean.
WARRANTY INFO
Please Visit nicerecovery.com/warranty
HOW TO USE
Construct the footbed by adhering the bottom of the wrap as shown
Slide heel into footbed and secure fit with Velcro tabs
Fit should be comfortably snug with no creases or folds
NICE1 COLD + COMPRESSION THERAPY SYSTEM
CONSULT A HEALTHCARE PROFESSIONAL BEFORE USING NICE1
-
Connect the power cord to the external power supply.
-
Plug the circular connector into the back of the Cooling Unit. You will hear a click when properly connected.
-
Plug the power cord into the wall outlet.
-
Connect the hose to the control unit. You will hear a click when properly connected.
-
Place the wrap on the appropriate body part. Secure with Velcro strips.
-
Connect the hose to the wrap. You will hear a click when properly connected.
STEP 1
Turn on the power switch on the back of the device. The touch screen will
illuminate and display the “Nice” logo. Press Start. Review the checklist on
the touch screen. Confirm and press NEXT.
STEP 2
Select desired COLD LEVEL and press NEXT.
(level 5 is the coldest setting).
Cold settings are as follows:
- Level 1 = 58F (14.4C)
- Level 2 = 54F (12.4C)
- Level 3 = 50F (10C
- Level 4 46F (7.7C)
- Level 5= 42F (5.5C)
STEP 3
Select desired COMPRESSION LEVEL and COMPRESSION TYPE and press NEXT.
STEP 4
Choose a MANUAL time setting of 5 – 40 minutes for a single therapy session OR
choose a PRESET PROGRAM for multiple sessions and press NEXT. Note: Preset
timing programs are on a 10-cycle memory.
STEP 5
Review and confirm your settings by pressing START or press BACK to change the
settings.
STEP 6
During your therapy session you can change the cold or compression settings
simply by pressing 1 – 5 or HIGH, MED or LOW. To Dim, Press Dim switch, to
brighten — touch screen.
SYMBOL
- Caution: Consult accompanying documents
- Refer to User Manual and Labels. Follow instructions for use.
- Lot or Batch Number
- Serial Number
- Caution: Federal law restricts this device to sale by or on the order of a physician
- Warning: It is Mandatory to fully read and understand the instructions for use before using the device. Failure to follow operating instructions could result in serious injury.
- Type BF applied parts
- Manufacturer
- Medical Device
- -25°C to +5°C, and +5°C to 35°C at RH up to 90% non- condensing, and>+35°C to 70°C at water vapor pressure 50h Pa
For more information:
Call a customer repres entative at
888-815-9907 or emai l
info@nicerecovery.com
Location: Boulder, CO 80301
PROUDLY MADE IN COLORADO
Visit: nicerecovery.com