GENERAL SPECIFICATIONS.
ELECTRICAL
MODEL NO.:
| PS-3KX| X PS-4KX| PX-7KX|
PS·8KX
---|---|---|---|---
(A-l) INPUT RATING.|
INPUT VOLTAGE: 10S·125VAC(11SV NORMAL).| YES| YES| YES| YES
INPUT LINE FREQUENCY: 60Hz.| YES| YES| YES| YES
INPUT POWER: MAX.| SOW| SOW| 70W| l00W
(A-2) OUTPUT RATING.|
OUTPUT VOLTAGE 13.8VDC ± O.3V| OUTPUT VOLTAGE 13.8VDC ± O.3V| YES| YES| YES
OUTPUT CURRENT: CONT/MAX| 2/3A| 3/4| 517A| 6/S
OUTPUT CURRENT: CONT/MAX| | | |
LOAD REGULATION: 2.S%(280mV P.P)MAX| YES·| YES·| YES·| YES·
(A-4) PROTECTION| | | |
PROTECTION. INPUT LINE PROTECTION: GLASS TUBE FUSE 1.5A12S0V 1.0Al2S0V
15A/250V 1.SAl250V OVER-LOAD PROTECTION: + 10% -15% (AUTO
RESET| 3A| 4A| 7A| SA
Ov’ER TEMPERATURE PROTECTIO| YES| | YES| YES
( A-6) DESIGN: LINEAR TYPE.
(A-7) OPERATING TEMPERATURE: 0 TO +40 DEG C.
(A-8) STORAGE TEMPERATURE : – 2S TO + 70 DEG C .
NOTE ·: INPUT AT 115VAC AND OUTPUT AT CONT. CURRENT
MECHANICAL:
DIMENSIONS 19Omm)( 125mm)( 76mm. (l x W x H)
B-2) WEIGHT KGS| I. 7 KGS| 18KGS| 2lKGS| 2.5KGS
(B-3) ENCLOSURE 8LACK| YES| YES| YES| YES
(B-4) INPUT CABLE 18AWGx2C W/l·15P PLUG| SPT-26FT| SPT·2 6FT| SPT-2 6FT| SPT·2
6FT
(B-S) OUTPUT TERMINAL: BINDING POST, 10Al125V| YES| YES| YES| YES
(8-6) POWER SWITCH ILLUMINATED, 1 5A112SVAC| YES| YES| YES| YES
CIRCUIT DIAGRAM PS·3KX/4KX/7KX/8KX
CIRCUIT ARE Subject TO CHANGE WITHOUT NOTICE
OPE RATION:
- INSERT AC POWER Pug INTO A IIOV VOLT AC OUTLET.
- CONNECT THE POWER CORD OF YOUR EQUIPMENT (13.5V – 14 1VDC) TO THE OUTPUT BINDING POST TERMINALS ON THE FRONT OF THE UNIT BE SURE THAT POLARITY IS CORRECT. THE RED POSITIVE (+) TERMINAL AND BLACK NEGATIVE (-) TERMINAL ARE MARKED. REVERSAL OF POLARITY. MAY DAMAGE YOUR EQUIPMENT.
- TURN SWITCH TO “ON”. RED LIGHT IN SWITCH WILL ILLUMINAfE
- THE INPUT POWER IS PROTECTED BY THE FUSE WHICH IS LOCATED AT THE REAR OF THE UNIT AND CAN BE REPLACED BY UNSCREWING THE FUSE HOLDER IF THE FUSE IS BURNT OUT. DO NOT USE A FUSE LARGER THAN •• AMPS USE OF HEAVIER FUSE MAY RESULT IN DAMAGING TO THIS UNIT ( •• SEE NOTE)
- THIS UNIT HAS ELECTRONIC OVERLOAD PROTECTION WITH INSTANT AUTOMATIC RESET FUNCTION IF OUTPUT IS OVERLOADED. THE OUTPUT POWER WILL AUTOMATICALLY SHUT OFF. RELEASE POWER CORD Of YOUR EQUIPMENT FROM THE OUTPUT TERMINALS AND CHECK THE ACTUAL POWER RATING OF YOUR EQUIPMENT. THIS UNIT WILL AUTOMATICALLY RESET INSTANTLY
- OVER TEM PERATURE PROTECTI ON CIRCUITRY IS USED IN PS-7KX/BKX TO PREVENT OVER HEAT DAMAGE UNIT WI LL BE SHUT DOWN MINUTES AFTER 15 MINUTES( M IN. ) AT 100% RATED LOAD.
NOTE
- PS-3KX: 1. 5 AM P
- PS-4KX : 1 0 AMP
- PS-7KX: 1-5 AMP
- PS-SKX : 1.5 AM
CAUTIONS
- DO NOT USE WITH EQUIPMENT REQUIRING MORE THAN RATING AMPS
- DO NOT USE OUTDOORS. DO NOT EXPOSE UNIT TO RAIN. MOISTURE. WATER OR ANY OTHER LIQUIDS
- DO NOT REMOVE COVER IN ANY CASE. RETURN TO DEALER FOR REPAIR IF DAMAGED.
- THIS UNIT HAS A SPECIAL BUILT-IN FEATURE THAT WILL SHUT THE UNIT OOWN IF MARKED AMPERAGE IS EXCEEDED. THIS WILL AVOID BURN-OUT OF YOUR EQUIPMENT AND OF UNIT. IF UNIT DOES CONSISTENTLY SHUTDOWN. THIS MEANS YOU ARE DRAWING TOO MUCH AMPERAGE. RETURN UNIT TO PLACE OF PURCHASE AND UPGRADE TO NEXT AVAILABLE UNIT OFFERING HIGHER AMPERAGE. PLEASE DO NOT BYPASS OR ALTER THIS CIRCUIT AS IT IS THERE TO PROTECT YOU. ANY ALTERATION OR MISUSE WILL VOID YOUR WARRANTY.
DANGER”
HIGH VOLTAGE
REFER TO QUALIFIED TECHNICIAN FOR SERVICE.