Operational Precaution
IM 01R01A01-91E
R3.04 Mobile Device Management Tool
PART A
This document supplements information regarding Operational Precaution before
use on IM 01R01A01-01E.
OPERATE THE PRODUCT CAREFULLY BASED ON THE FOLLOWING CAUTION, IMPORTANT,
NOTES, AND RESTRICTIONS.
Caution
-
Modem (F9197UF)
The modem connection is applied in non-hazardous areas only.
And the modem should not be connected to cables with over 75VDC/50VAC.
EMC Conformity Standards -
CE
EN61326-1 Class A, Table1
RoHS directive: EN IEC 63000 -
KC Mark
Registration No: MSIP-REM-YHQ-EEN441 -
RCM
EN61326-1 Class A, Table1 -
EACH
TP TC 020/2011 -
WEEK
Waste Electrical and Electronic Equipment (WEEE), Directive
(This directive is only valid in the EU.)
This product complies with the WEEE Directive marking requirement.
The following marking indicates that you must not discard this electrical/electronic product in domestic household waste.
Product Category
With reference to the equipment types in the WEEE directive, this product is classified as a “Monitoring and control instrument”.
Do not dispose of this product in domestic household waste.
When disposing of products in the EU, contact your local Yokogawa Europe B. V. office. -
Manufacturer
Yokogawa Electric Corporation (2-9-32 Nakacho, Musashino-shi, Tokyo 180-8750, Japan) -
Authorized Representative in the EEA
Yokogawa Europe BV. (Address: Euroweg 2, 3825 HD Amersfoort, The Netherlands) is the Authorized Representative of Yokogawa Electric Corporation for this Product in the EEA.
Important
-
Connection
The FieldMate should not be connected to the terminal box or the field devices when the control system is in operation. (i.e. CENTUM system or other venders’ control system) -
USB FieldMate Modem
Analog output may change temporally in connecting with USB FieldMate Modem due to an Initial current flowing to it. Also, the communication signal is superimposed on the analog output signal.
It is recommended to set a low-pass filter (approximately 0.1s) to the receiver in order to reduce the output effect from the communication signal and to prevent the communication signal from affecting the upper system.
Before online communication, confirm that the communication signal does not give an effect on the upper system. -
FieldMate Installation
If the operating system of the computer into which FieldMate is to be installed is Windows 10, the Microsoft .NET Framework 3.5 function must be enabled.
Please verify as follows: Control panel – Programs – Turn Windows features on or off – “.NET
Framework 3.5 (including .NET 2.0 and 3.0)”.
- Enabling Microsoft .NET Framework 3.5 function in advance “PC’s connection to the Internet” is necessary.
- Enabling Microsoft .NET Framework 3.5 function during installation of FieldMate “PC’s connection to the Internet” is necessary.
• If Microsoft .NET Framework 3.5 function is not enabled, Type A Yokogawa DTM Device (described hereafter) cannot be used as a function restriction.
Note
Installer & General
a) Software Install
PRM and FSA210 cannot coexist in the same PC.
b) Communication Interface Driver
FieldMate installer covers the followings:
USB FieldMate Modem driver
Install separately according to their instructions for other communication
interface drivers.
c) Network Environment
PC with Microsoft Network Client and Internet Protocol (TCP/IP) is required
for proper installation
d) Stand-by Mode, Power Saving Mode on PC
d-1. Stand-by Mode on PC
It is not advisable to use the PC standby mode. After recovery, NI-FBUS may
not respond.
When Ir-adaptor is used, a PC reboot may be required.
d-2. Power Saving Mode on PC
Please do not set the power management settings into power-saving mode on the
communication port. In the power-saving mode, it may not work properly.
e) Windows User
Log on to Windows with “Administrator” privileges, then or to start and
operate FieldMate.
f) Handling of 3rd party DD and DTM
Although 3rd party DD and DTM are included in the Device Files DVD-ROM,
Yokogawa certifies the quality and operability of only our DD and DTM.
g) Installation of Device Files on the former version
In the case of Device Files R3.09 on FieldMate R3.03.10 or earlier and PRM
R4.01 or an earlier version, DTM may not work. Please use Device Files R3.09
on FieldMate R3.04.
h) Default password for Administrator
When a new user is assigned in User Management and logs on to Windows as
DefaultUser or Administrator, requires the case sensitive password,
“FieldMate”.
i) BRAIN DTM Install
When individually BRAIN DTM is installed, message windows may show up during
installation.
Either pressing “Yes” or “No”, the installation will be processed normally.
j) CD/DVD-ROM installer
If the installation does not start automatically, double-click the following
files.
FieldMate CD-ROM\FM\Setup.exe
Device files DVD-ROM\PRMFMDeviceFiles.exe 1
1 This is effective only when FieldMate is installed on your PC.
k) Adobe Reader
Adobe Reader of Adobe Systems Incorporated is required to view the user’s
manual. If Adobe If the reader is not installed on the PC to be used, please
download it from the home page of Adobe Systems Incorporated.
FOUNDATION Fieldbus H1 Communication
a) NI-FBUS Setting
Using the FOUNDATION Fieldbus H1 communication function, define the NI-FBUS
before use as follows.
Device Address = Visitor
Device Type = Link Master: (“Basic” to be specified when the other Host
exists)
Usage = NI-FBUS
b) Device Class Setting
The device may not appear on the Segment Viewer immediately after changing the
FOUNDATION Fieldbus H1 device class on Device Class Setting. It will take
approximately 30 seconds to update the display.
DTM Works
a) DTM License
Some device DTM and COMM DTM specify the relevant Frame Application where they
can perform with the check function built in.
Restriction
Installer & General
a) Device Tag Name
The table below is restrictions on the displays of Segment Viewer and
Parameter Manager of the FieldMate.
Characters to pay attention| Tag Name on Segment Viewer and Parameter Manager
Frame
---|---
Period [.]| Only former pads before “.” is displayed. Ex.: PT12.34 -> PT12
Exclamation mark [!]| Only former pads before “!” is displayed. Ex.: P112!34
-> PT12
Space [SP]| Only former pads before Space is displayed. Ex.: PT12 34 -> PT12
Double quotation [“]| A double quotation will be transformed to ” ”
Underscore.
Ex.: PT12″34 -> PT12 34
The last character is backslash [\]| The backslash is located on the Last
character of the device tag, it will be
transformed to ” ” Underscore. Ex. : P11234\ –>P11234
Modem and interface card
a) Interface hardware
It is not advisable to disconnect while communication is established. It may
cause damage to the communication driver, FieldMate software, etc.
Any of the followings:
HART Modem: HART communication
FieldMate Modem: BRAIN/HART communication
NI-FBUS card/NI-USB 8486: FOUNDATION Fieldbus H1 communication
PROFIusb: PROFIBUS communication
PBproUSB: PROFIBUS communication
Infrared adaptor (ACT-IR224UN-LN96-LE): ISA100.11a OOB infrared communication
FOUNDATION Fieldbus H1 Communication
a) Parameter with date and time
Data and time data may differ on Parameter Manager and DTM
Main Windows
a) Tag/Address Assignment of Extended Device Tag
In Message mode, after entering the New HART Message, “HART Command Error –
Device is busy” may appear. Update Segment Viewer to display the correct
Device Tag.
DTM Works
a) Disconnect Operation in DTM
When the Disconnect command is activated while FieldMate is in communication
with the field device, DTM Works may not be able to close. Terminate DTM works
application on Windows task manager.
b) DTM parameter refresh
More time may be anticipated than the setting value of the refresh rate on the
screen.
c) PROFIBUS DTM
Only one PROFIBUS device DTM can start from Segment Viewer due to comm DTM or
driver constraint.
d) Message from PROFIBUS DTM
Block names of work and operations implemented on DTM works are not shown in
History.
e) PROFIBUS DTM help window
If the parameter cannot be accessed after opening the online help window by
clicking the “?” icon on the screen, open another window by selecting the menu
tree, and try to access the parameter again.
f) PROFIBUS DTM for AXF
It is advisable to use PROFIBUS COMM DTM, PROFIusb DPV1 V5.45, or later.
g) PROFIBUS DTM
Clicking the default setting button on the left bottom corner in the offline
parameter window may cause a communication error. In this case, restart DTM
Works.
h) HART DTM
· Clicking the refresh icon in disconnect status may cause a communication
error. In this case, restart DTM Works.
· Do not press the F1 key while the method is performed in DTM.
DD Menu
a) Historical Message
On DD Menu, history is saved in the form of a “block tag name” for the
FOUNDATION Fieldbus H1 device.
In contrast, on Parameter Manager, it is saved in the form of a “general block
tag name”, which indicates the type and number of the block.
Device Viewer
a) Polling address update
While Device Viewer is open, changing the polling address, the relevant
display is not updated.
Close Device Viewer, update at Segment Viewer, and start Device Viewer again.
b) Engineering unit update
While Device Viewer is open, changing the engineering unit, the relevant
display is not updated.
Close Device Viewer, start Parameter Manager, and start Device Viewer again.
c) Alarm description language
The alarm description in the Device Viewer display appears in English.
Revision Information
- Title: FieldMate R3.04 Operational Precaution
- Manual No. : IM 01R01A01-91E
Nov. 2006/2nd Edition
Contents revised for FieldMate R1.02.10
Nov. 2008/3rd Edition
Contents revised for FieldMate R1.03.00
Aug. 2008/4th Edition
Contents added and revised on DTM2008-2 issue
Jan. 2009/5th Edition
Contents revised for FieldMate R2.01.00
Apr. 2009/6th Edition
Contents revised for FieldMate R2.01.10
June 2010/7th Edition
Contents revised for FieldMate R2.02.00
Feb. 2011/8th Edition
Contents revised for FieldMate R2.03.00
Sep. 2011/9th Edition
Contents revised for FieldMate R2.04.00
Aug. 2012/10th Edition
Contents revised for FieldMate R2.05.00
May 2013/11th Edition
Contents revised for FieldMate R2.06.00
Oct. 2014/12th Edition
Contents revised for FieldMate R3.01.10
Apr. 2016/13th Edition
Contents revised for standard compliant
Aug. 2016/14th Edition
Contents revised for FieldMate R3.02.00
Aug. 2017/15th Edition
Contents revised for FieldMate R3.03.00
Dec. 2017/16th Edition
Contents revised for new USB FieldMate modem (F9197UF)
Nov. 2018/17th Edition
Contents revised for FieldMate R3.04.00
June 2021/18th Edition
Contents revised on EMC Conformity Standards
IM 01R01A01-91E 18th Edition: June 18, 2021-00
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>