UGREEN GS2200 Portable Power Station Power Roam 220
Product Information
Specifications
- Dimensions: N/A
- Weight: N/A
- Lithium Battery Rated Energy: N/A
- Input: 100-130V~ 60Hz 15A Max
- Output:
- DC: 12-60V 15A (Single-Port: 600W Max, Dual-Port: 1200W Max)
- USB-A: Single-Port: 5V 3A/9V 2A/12V 1.5A/5V 4.5A 22.5W Max, Dual-Port: 5V 3A 15W Max
- USB-C1: 5V 3A/9V 3A/12V 3A/15V 3A/20V 5A/28V 5A 140W Max
- USB-C2: 5V 3A/9V 3A/12V 3A/15V 3A/20V 5A 100W Max
- USB-C3/C4 : 5V 3A/9V 3A/12V 3A/15V 3A/20V 2.25A 45W Max
- AC: 12V 10A 120W Max, 12V 25A 300W Max
- Total Output Power: 2500W Max
- Environmental Operating Temperature: 32~104°F (0~40°C)
- Recharging Temperature: 14~104°F (-10~40°C)
- Discharging Temperature: N/A
Product Usage Instructions
**Recharging Your Power Station
**
Safety Precautions:
- Important Note: N/A
AC Recharging
- Recharge with Power Zip Fast Charging 1800W Max. Input Power
- AC Power Cable: N/A
-
Solar Panel Recharging
Before connecting a solar panel, ensure its total output voltage is within the range required by the power station (12V-60V), or it will not charge. -
Maximum Power Recharging:
This power station comes equipped with dual DC input ports. To charge at the fastest speed, connect three 200W solar panels in series to each port simultaneously for up to 600W via a single port (as shown in the picture) and 1200W using dual ports.- Solar Panel Serial Adapter: N/A
-
Car Recharging
- Car Charging Cable: N/A
**Powering Your Devices
**
Power On/Power Off:
- Press to turn on
- Press and hold for 3 seconds to turn off.
Tips:
While powered on, if the power station is not used within 1 minute, the
display automatically turns off. Press any button to turn display on.
-
AC Output
Press again to turn off. -
Tips:
Damage to the power station and connected device(s). -
Car Charging Output / DC5521 Output
Press again to turn off. -
Anderson Output
In the standby state, press the DC button to turn off. -
USB Output
Press again to turn off -
App Download Guide
To control the power station via mobile device, scan the QR code to download the UGREEN App:
Features & Operating Modes
-
U-Turbo:
But U-Turbo Mode is not applicable for all electrical appliances. Inductive devices and some precision instruments are not recommended. -
Power Reduction Mode:
In this mode, the recharging/discharging power of the power station is reduced. This is to improve the overall lifespan of the power station. For safe use, Power Reduction Mode will automatically turn on in the following 4 states:
- Low temperature
- High temperature
- Low battery charging
- Trickle charging (The Power Reduction Mode icon on the LCD display illuminates to indicate that the mode is on.)
FAQ
No frequently asked questions available.
Product Overview
Product Details
- ON/OFF Power Button/ON/OFF Power Indicator
- DC Power Button/DC Output Indicator
- IoT Button/ IoT Indicator
- Flashlight Power Button
- AC Power Button/AC Output Indicator
- LCD Display
- AC Output Outlets × 6
- Anderson Output Port
- USB-A Output Ports × 2
- USB-C Output Ports × 4
- DC5521 Output Ports × 2
- Car Charging Output Port
- Flashlight
- Ventilation Outlet
- AC Input Outlet (Utility Power)
- Expansion Battery Port
- DC Input Port (Solar/Car Charging)
- Protective Earth Screw
- Overcharge Protection Switch
LCD Display
Specifications
General Info
Dimensions| 54×25×29 (cm) / 21.3×9.8×11.4 (in)
- Weight
- Lithium Battery
| About 25.5 kg /56.2 lbs.
- Rated Energy
- Input
| 2048Wh 40Ah 51.2V
AC| 100-130V~ 60Hz 15A Max
Solar Charging (×2)| 12-60V 15A (Single-Port: 600W Max, Dual-Port: 1200W Max)
- DC/Car Charger
- Output
| 12V/24V 8A Max
AC (×6)| 120V~ 60Hz 20A 2400W Max
USB-A (×2)| S(Dinugalle-P-Poortr :t:55VV 33AA1/59WV M2aAx/)12V 1.5A/5V
4.5A 22.5W Max
USB-C1| 5V 3A/9V 3A/12V 3A/15V 3A/20V 5A/28V 5A 140W Max
USB-C2| 5V 3A/9V 3A/12V 3A/15V 3A/20V 5A 100W Max
USB-C3/C4| 5V 3A/9V 3A/12V 3A/15V 3A/20V 2.25A 45W Max
Car Charger (×1)| 12V 10A 120W Max
Anderson Output (×1)| 12V 25A 300W Max
DC5521 (×2)| S(Aindleer-sPoonrt+: 1C2aVr Ch5Aar6g0eWr +MDaCx5,
5D2u1a×l-Po2r=t:31020VW M10aAx)120W Max
- Total Output Power
- Environmental Open
| 2500W Max rating Temperature
Recharging Temperature| 32℉~104℉ (0℃~40℃)
Discharging Temperature| 14℉~104℉ (-10℃~40℃)
Recharging Your Power Station
Safety Precautions
- Before charging, please make sure the power station is properly grounded.
- Please use an original or safety-certified power cable that meets the charging specifications of this power station.
- When charging, ensure the power station is well-ventilated and free from combustibles.
Important Note
- Please charge power station before initial use to activate.
- In order to ensure safety while charging, overcurrent protection will automatically trigger when the input current exceeds the overcurrent protection value. When this happens, the Overcharge Protection Switch will protrude. Once the overcurrent is abolished, press the switch to resume charging.
- If the power station shows a low battery, please recharge promptly. Refraining from prompt recharge may result in the battery becoming inoperable.
AC Recharging
Recharge with Power Zip Fast Charging 1800W Max. Input Power
Solar Panel Recharging
Before connecting a solar panel, ensure its total output voltage is within the
range required by the power station (12V-60V), or it will not charge.
Maximum Power Recharging
This power station comes equipped with dual DC input ports. To charge at the
fastest speed, connect three 200W solar panels in series to each port
simultaneously for up to 600W via a single port (as shown in the picture) and
1200W using dual ports.
Tips
- Ensure that you use the included serial adapter and that the specifications for the connected solar panels are the same.
- Additional solar panel connection cables are sold separately.
Car Recharging
To charge the power station via vehicle cigarette lighter port:
- Please start the vehicle before recharging the power station with car charging cable. This will prevent vehicle failure to start due to insufficient battery.
- Please ensure cigarette lighter port and the car charging cable are properly connected.
Flashlight
In the standby state, you can switch between 5 states:
Powering Your Devices
- Power On/Power Off
Tip:
While powered on, if the power station is not used within 1 minute, the
display automatically turns off. Press any button to turn display on.
AC Output
Tips:
- To switch AC output frequency, press and hold the AC Power Button for 10 seconds while the AC output is off.
- Please check the rated frequency of the device before use. Improper frequency settings will result in damage to the power station and connected device(s).
Car Charging Output / DC5521 Output
USB Output
App Download Guide
- To control the power station via mobile device, scan the QR code to download the “UGREEN” App:
Tips:
- You can also search for “UGREEN” in App Store or the Google Play Store
- Open the “UGREEN” App, and go to “Help” to download the “App User Guide”.
Features & Operating Modes
U-Turbo
While the U-Turbo Mode is active, the AC multi-port output of the power
station can support devices with power ratings of up to 3500W.
Tips :
- For a safer charge, the U-Turbo mode is temporarily disabled while the power station is simultaneously charging and charging other devices.
- U-Turbo is enabled by default. You can disable it using the “UGREEN” App.
- The AC multi-port output can support heating devices up to 3500W like hair dryers, electric kettles, etc., but U-Turbo Mode is not applicable for all electrical appliances. Inductive devices and some precision instruments are not recommended.
Power Reduction Mode
In this mode, the recharging/discharging power of the power station is
reduced. This is to improve the overall lifespan of the power station.
For safe use, Power Reduction Mode will automatically turn on in the following
4 states:
- Low temperature
- High temperature
- Low battery charging
- Trickle charging
(The Power Reduction Mode icon on the LCD display illuminates to indicate that the mode is on.)
0% Battery Emergency Mode
- This mode allows for flashlight and USB ports usage when battery level is at 0%.
When powered on, press and hold the DC Power Button and Flashlight Power Button for 10 seconds at the same time to enable this mode. After use, press and hold the ON/OFF Power Button for 3 seconds to disable.
Tips:
- This mode is only available when the battery level is 0%.
- Please avoid using this mode frequently, as power station battery life could be negatively affected.
- After using this mode, promptly charge the power station, otherwise it may become unusable.
Operating Mode
Factory Reset
- To perform a factory reset, ensure the power station is not connected to any other device/appliances/etc. Press and hold the AC Power Button and the DC Power Button simultaneously for 10 seconds to restore the power station to factory settings.
Note:
This operation will clear all function settings saved by the power station.
Perform reset with caution.
Expansion Battery
This power station is capable of connecting to an expansion battery. For
more information, please refer to the Ugreen EB2000 Expansion Battery (2048Wh)
User Manual.
FAQs
in the “UGREEN” App [Settings].” image-3=”” headline-4=”p” question-4=”Why does the power station run out of battery even when no device is connected?” answer-4=”When the AC Output Outlets are on, even if no device is connected, there will be a certain amount of no-load power consumption. To avoid this, please ensure the AC Output Outlets are turned off when not in use to conserve battery.” image-4=”” count=”5″ html=”true” css_class=””]
Troubleshooting
Note: In the case unresolvable issues occur, please contact UGREEN Customer Service.
What’s In The Box
Safety Instructions
Warnings
- This power station contains a lithium battery; please do not disassemble, violently impact, or squeeze the power station.
- Do not throw the power station into fire, or use it in situations of high temperature and during short circuit.
- Do not insert foreign objects or fingers into the power station or use sharp objects to puncture it, so as to avoid damaging the power station or unintentionally causing an explosion due to abnormal use or short circuit.
- If the power station accidentally falls into water, it should be immediately moved into a safe, open area until it is completely dry. Do not use it again. Dispose of it properly according to the Disposal Guide detailed in this manual.
- Due to the particularity of the power station (built-in battery, high-voltage, etc.), please keep the power station out of reach of children and pets. Special groups are recommended to use it under the protection and supervision of a designated guardian.
Notes for Safe Use
- Do not place heavy objects on this power station.
- Please use the power station in a dry and well-ventilated environment. While in use, ensure the ventilation outlets of the power station are not blocked.
- Do not place the power station near sources of heat or fire, such as microwave ovens, pressure cookers, heating furnaces, etc. If the power station catches fire, please use fire extinguishing equipment as quickly as possible.
- Do not expose the power station to any liquids and do not use it in rainy or humid environments.
- If the power station is subjected to strong impact or fall, do not continue normal use. Please dispose of it properly according to the Disposal Guide in this manual.
- Do not use this power station in environments of strong electrostatic or electromagnetism.
- When not in use, please remove the power cord of the power station and all connected external devices. When unplugging the power cord, please pull it out from the plug directly, rather than pulling on the cord.
- Do not use non-UGREEN cords or parts. If repair or replacement parts and/or accessories are required, please contact UGREEN customer service.
- Do not use a damaged power cable to charge the power station.
- Please use the power station at the specified working environment temperature.
Transportation & Storage
- Please store this power station in a dry place, at room temperature.
- Do not store or transport this power station with metal objects (glasses, watches, metal necklaces, hairpins, etc.).
- If you want to ship this power station via logistical means, please discharge the power station battery to 10%~30%.
- This power station cannot be carried on a plane. Please abide by the relevant regulations of civil aviation transportation.
Maintenance
- For long-term storage, please use the provided dust cover to cover the power station. Please charge and discharge at least once every 3 months (discharge to 0%, charge to 100%, then finally discharge to 30%-60%) to ensure battery health.
- For long-term storage, please check the power station’s remaining battery level. If it shows a low battery, please charge first, otherwise the battery may be damaged.
- Please store the power station at the appropriate storage environment temperature (20℃~25℃/68°F-77°F) specified in this manual.
- If the port of the power station is dirty, please clean with a dry cloth. Do not clean with chemicals or spray cleaners.
Disposal
- Please dispose of this power station in accordance with local laws and regulations regarding battery recycling and disposal. Do not dispose of it in ordinary trash.
- Be sure to fully discharge the battery of this power station before disposing of it in the designated battery recycling bin.
- If the battery cannot be completely discharged due to product failure, please contact a professional battery recycling company for further processing.
Disclaimer
- Before use, please read this manual carefully, and use the power station correctly in accordance with all safety instructions in this manual. Relevant safety precautions especially must be followed. After reading, please keep the manual for future reference.
- This power station is not intended for use with devices that require extreme reliability and/or security, including but not limited to: medical/life support devices such as medical ventilators, precision instruments (e.g. theodolite, barometers), and specialized devices such as data servers. Please do not use this power station under any high-risk or life-threatening scenario. UGREEN expressly disclaims any express or implied warranties of suitability for high-risk activities. Any such use is a misuse of the power station.
- To the extent permitted by law, improper use of this power station may directly or indirectly result in damages to the power station and/or personal property and cause personal injury. UGREEN will not assume any legal responsibility. Under the condition of compliance with laws and regulations, UGREEN has the final right to interpret this manual and other related documents of this power station. The User Manual is subject to update, revision, or termination without notice, but updates can be received via the “UGREEN” App or https://www.ugreen.com/.
Warranty Information
- A limited 5-year warranty applies to all UGREEN portable power stations purchased from UGREEN or authorized sellers. Please feel free to contact us if you run into any problems. For more details on the product warranty, please visit: www.ugreen.com.