Kasco 2400VFX VFX Decorative Aerator Instruction Manual
- June 14, 2024
- Kasco
Table of Contents
- Kasco 2400VFX VFX Decorative Aerator
- Product Information
- SAFETY FIRST
- UNIT SPECIFICATIONS
- PARTS INCLUDED
- ASSEMBLY INSTRUCTIONS
- INSTALLATION INSTRUCTIONS
- MAINTENANCE RECOMMENDATIONS
- TROUBLESHOOTING TIPS
- WARRANTY
- NOTE
- CONTACT US
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Kasco 2400VFX VFX Decorative Aerator
Product Information
Specifications
- Model: VFX Decorative Aerator
- Available Models: 2400, 3400, 4400
- Pattern Size: Varies depending on model
- Voltage: 110-120V (2400VFX, 3400VFX, 4400VFX), 208-240V(3400HVFX, 4400HVFX)
- Operating Amps: 5 (2400VFX), 6 (3400VFX), 11 (4400VFX), 4 (3400HVFX), 6 (4400HVFX)
- Locked Rotor Amps: 20 (2400VFX), 24 (3400VFX), 39 (4400VFX), 12(3400HVFX), 19 (4400HVFX)
- Control Panel Connection: C-25 plug in / Plug into C-25(2400VFX, 3400VFX, 4400VFX)
- Unit Connection: Hardwire C-85 / Hardwire into C-85 (3400HVFX, 4400HVFX)
- Height: 5.5 ft. (2400VFX, 3400VFX), 8 ft. (4400VFX, 4400HVFX)
- Width: 15 ft. (2400VFX), 21 ft. (3400VFX, 4400VFX, 4400HVFX)
Parts Included
- A: Float
- B: 1/4-20 x 3-1/2 screw
- C: 1/4 split washers
- D: 1/4 (3/4 OD) Flat Washer
- E: 1/4 -20 x 1-3/4 Hex Head Bolt
- F: Bottom Screen Section
- G: 1/4-20 Nut
- H: #8 nut
- I: #8 flat washer
- J: #8 split lock washer
- K: #8 x 3/4 screw
- L: Mooring ropes (not pictured)
- L: Cable ties (not pictured)
Assembly Instructions
- Align the power cord with the provided notch.
- Attach parts B, C, D, E, and F according to the diagram.
- Attach parts K, J, I, H, G, and F according to the diagram.
- Attach parts C, D, D, and E according to the diagram.
Installation Instructions
- Attach the strain relief to the line closest to the cord.
- Ensure proper anchoring by keeping mooring lines at least 3 feet from the float for every foot of water depth.
- Refer to the diagram for alternate installation options based on water level.
Maintenance Recommendations
- Always disconnect power before performing maintenance.
- Regularly observe the equipment for any changes in performance.
- If clogs are observed, disconnect power and remove them as soon as possible to avoid damage to the equipment.
- When storing the equipment for long periods of time, such as during off-season storage, store it with the cage down to prevent drying of the seals.
TOOLS AND SUPPLIES NEEDED
SAFETY FIRST
- NEVER enter the water with the electrical equipment connected and/or in operation.
- Stay clear of all moving parts.
- NEVER run the unit out of water. This will damage the equipment and pose a danger to the operator.
- Use extreme caution around water, especially cold water.
- NEVER lift or drag the unit by the power cord. Always use the ropes or mount to remove it from the water.
- Do not use waders in deep water or in areas with drop-offs, drastic slopes, or soft bottom material.
- Do not use boats that tip easily for unit installation (such as canoes).
- Follow all boating safety rules and regulations, including wearing a Personal Flotation Device.
- The unit is supplied with an internal grounding conductor. To reduce the risk of electrical shock, be certain that the unit is plugged in/connected to an approved GFCI-protected circuit.
- Means for disconnection must be incorporated in the fixed wiring, in accordance with local and national wiring rules.
- Consult a qualified electrician for electrical installation.
UNIT SPECIFICATIONS
Model| Pattern Size
Height Width
| Voltage| Operating Amps| Locked **Control Panel Connection / Rotor Amps ****Unit Connection**
Single-Phase Units
---|---|---|---|---
2400VFX| 5 ft.| 15 ft.| 110-120| 6| 20| C-25 plug in / Plug into C-25
3400VFX| 5.5 ft.| 21 ft.| 110-120| 7| 24| C-25 plug in / Plug into C-25
3400HVFX| 5.5 ft.| 21 ft.| 208-240| 4| 12| Hardwire C-85 / Hardwire into C-85
4400VFX| 8 ft.| 26 ft.| 110-120| 11| 39| C-25 plug in / Plug into C-25
4400HVFX| 8 ft.| 26 ft.| 208-240| 6| 19| Hardwire C-85 / Hardwire into C-85
PARTS INCLUDED
ID | Description | Qty | Part # |
---|---|---|---|
A | Float | 1 | 242001 |
B | 1/4″-20 x 3-1/2″ screw | 4 | 251210 |
C | 1/4” split washers | 7 | 840537 |
D | 1/4” (3/4” OD) Flat Washer | 10 | 251300 |
E | 1/4 -20 x 1-3/4” Hex Head Bolt | 3 | 475630 |
F | Bottom Screen Section | 3 | 361540 |
G | 1/4”-20 Nut | 3 | 840536 |
H | #8 nut | 6 | 771034 |
I | #8 flat washer | 12 | 361543 |
J | #8 split lock washer | 6 | 771033 |
K | #8 x 3/4” screw | 6 | 361545 |
L | Mooring ropes (not pictured) | 2 | 990700 |
L | Cable ties (not pictured) | 9 | 415038 |
ASSEMBLY INSTRUCTIONS
INSTALLATION INSTRUCTIONS
Correct anchoring
Mooring lines are proper length and taut between unit and anchors (at least 3 feet from the float for every foot of water depth
Incorrect anchoring
MAINTENANCE RECOMMENDATIONS
Proper Installation
Proper installation of Kasco equipment will include a power source with ground
fault protection. The control panel included with the equipment has built-in
ground fault protection. Ground fault interrupters can also alert you to
electrical leaks in the equipment. It is extremely important to test the GFCI
upon installation and every month thereafter to ensure proper operation. In
the case of consistent trips of the ground fault device, disconnect the
equipment and remove it from the water. Inspect the power cord for damage and
contact your distributor or Kasco Marine (715.262.4488,
sales@kascomarine.com) for further
instructions. A complete list of control panels can be found in the
Accessories section of kascomarine.com.
ALWAYS DISCONNECT POWER BEFORE PERFORMING MAINTENANCE.
Observation
Observe equipment in operation on a regular basis (daily, if possible). If you observe a change in performance, disconnect the equipment from the power source and inspect for any material clogging the system or wrapped around the motor shaft. To avoid damage to the equipment, it is important to remove clogs as soon as possible. ALWAYS DISCONNECT POWER TO THE UNIT BEFORE ATTEMPTING TO REMOVE CLOGS.
Cleaning
Buildup of algae, calcium, barnacles, or other matter on the motor housing creates insulation and blocks heat transfer, so to prevent overheating, it is important to clean the unit. In warmer regions or in other areas prone to buildup such as this, inspect and clean the equipment regularly. In all regions, inspect and clean the equipment at least once a year. It is easiest to clean the unit immediately after removing it from the water, when the equipment is still wet. If you use a power washer, avoid hitting the mechanical seal area directly.
Unit Storage
Store the equipment with the cage down if it is going to be out of the water for long periods of time, such as during off-season storage. Seals on units that sit upright on a shelf for extended periods of time are more likely to dry out. Storing upside down or sideways will ensure oil is reaching the seals and help to prevent drying.
Sacrificial Anode
All Kasco units include a sacrificial anode installed on the shaft to protect against corrosion and electrolysis. Replace the anode if it is reduced to half the original size or if it is white in color. Corrosion from electrolysis most commonly occurs in saltwater or brackish water, but it is important to check the anode in all installations at least every two to three months.
Seal And Oil Replacement
This is a sealed motor assembly. Like brake pads on a car, seals wear out over time. Replace the seals and change the oil after three years to increase the motor’s longevity and to avoid more expensive repairs.
Other Repairs
Seal replacement and all other repair services should be performed at Kasco or a Kasco-trained authorized repair center. Please contact your Kasco distributor or representative to find your nearest service center. Please keep the original box for maintenance shipping.
TROUBLESHOOTING TIPS
A trip can indicate an electrical service problem, water contamination in the unit, motor issues, and problems with the cord, breaker, or control box. Consult Kasco or an electrician to address the issue. Prior to any consultation, collect this information: More troubleshooting tips are available in control panel manuals and at www.kascomarine.com. “My equipment trips a ground fault protection device.”
- How long does it take to trip the breaker?
- Does it always take the same amount of time to trip?
- How many times has it tripped?
- Have there been any electrical problems in the area recently?
“My equipment seems to run slowly.”
The unit may not be receiving proper voltage. This could also indicate a problem with the motor, which should be serviced by an authorized repair center. Check that the unit is receiving the proper voltage, and contact Kasco for further steps. Note: If the equipment has been stored or exposed to cold for an extended period without running, it may take some time for the prop to reach full speed once power is supplied.
“My equipment hums but will not start. When I spin the prop with a stick, it starts up.”
This indicates a problem with the starting capacitor. If the equipment is running but the prop is not spinning and spinning the prop with a stick starts the unit, then the starting capacitor needs to be replaced by an authorized repair center.
“My equipment turns itself off and back on without the timer and without tripping the breaker.”
Each Kasco unit is equipped with thermal overload protection, which turns the unit off if it overheats. The unit will start up again once it has cooled down. If you are noticing these symptoms, unplug the equipment immediately to prevent damage to the motor. Remove the equipment from the water and inspect for the cause of the problem. Some possible causes are low water levels, build-up preventing heat dissipation through the housing, or something stopping the free rotation of the shaft. If something is caught in the unit, or if there is a buildup on the can, remove the debris and clean the equipment.
“My equipment flow seems to fluctuate and/or be less than usual.”
Most of the time, this symptom is caused by debris clogging the unit. A mat of weeds, leaves, plastic bags, etc., can create a clog. If the unit does not have the proper amount of water, the flow or pattern will fluctuate and appear sporadic. If you are seeing these symptoms, unplug the unit and clean away the debris. While the unit is unplugged, check for another possible cause: a chipped or damaged prop, which can cause the unit to wobble in the water. Replace the prop if it is damaged.
“The breaker trips randomly and sporadically. Sometimes it is a few hours of operation, other times it can be days or weeks.”
Nuisance trips usually occur when the unit is installed far away from the initial electric service where the ground stake is located on the property. It is caused by either induced current in the ground wire or a base voltage difference due to soil pH levels. To resolve the problem, contact an electrician and install a local grounding stake. This may eliminate the induced current and any base voltage differences. This problem can also be caused by unbalanced incoming voltage lines or by a bad breaker or receptacle.
WARRANTY
Warranty period:
2400VFX, 3400VFX, 3400HVFX, 4400VFX, 4400HVFX = 2-year Limited Warranty
Kasco® Marine, Inc. warrants this fountain to be free from defects in material
or workmanship under nor-mal use and service (excluding ropes, power cord, and
propeller). The Kasco Marine, Inc. obligation under this warranty is limited
to replacing or repairing free of charge any defective part within the
warranty period from the date of shipment. Customer shall pay shipping charges
for returning the unit to Kasco or an Autho-rized Repair Center.
THIS WARRANTY IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESSED OR IMPLIED, AND
ANY OTHER OBLI-GATION OR LIABILITY WHATEVER ON THE PART OF KASCO MARINE, INC.
AND IN NO EVENT SHALL KASCO MARINE, INC. BE LIABLE FOR ANY SPECIAL OR
CONSEQUENTIAL DAMAGES.
- The equipment is not maintained properly according to the Maintenance Recommendations supplied in this Owner’s Manual.
- The equipment is returned for repair without the power cord.
- The unit, control panel, or power cord are altered in any way from original shipment. Cuts in the power cord are not covered under warranty.
- The equipment is damaged by unauthorized tampering.
- The sacrificial zinc anode around the motor shaft shows significant deterioration (not maintained according to Recommendations supplied in this Owner’s Manual).
Warranty Claim Procedure: The best method for establishing warranty period is by keeping your original receipt and registering the equipment online at kascomarine.com under the Support section. Once warranty coverage has been established, the unit may be sent to Kasco Marine or any Kasco Autho-rized Repair Center for evaluation and repair. See Repair section for more information regarding warranty repair procedure.
NOTE
Kasco only accepts complete assemblies for warranty repair. We must receive the power cord and all other components with the motor as originally assembled. Kasco will bill the customer to replace any missing parts necessary for repair. It is not necessary to return the control panel, mount, or other parts with the motor assembly, unless specifically requested by a Kasco representative. Please attach a repair form with the shipment. The repair form must include a name, physical address (for return delivery of the repaired unit), daytime phone number, and an e mail address for correspondence regarding the warranty claim. Any expedited shipping method for the return of the unit is at the customer’s expense. Kasco Marine will return units repaired under warranty at our expense via ground freight within the continental United States.
NON-WARRANTY REPAIRS
Most failed equipment can be repaired at substantially lower costs than
replacement with new. If your aerator requires repair and is no longer covered
under warranty, please contact Kasco Marine or your local distributor for
available options. Please ship according to the instructions on the previous
provided. Kasco Marine does estimates on repairs at the request of the
customer. The request for estimate should be included in the letter that
accompanies the returned unit and must include a daytime phone number and/or
e-mail address. We will contact the customer with a total after the unit has
been evaluated but before the work is performed. All estimates that are
rejected for repair will be destroyed unless otherwise directed by the
customer. Re-jected equipment can be returned at the customer’s expense for
shipping and handling charges. Billing: All non-warranty repairs will be
returned and billed to the customer unless otherwise directed. Kasco Marine
accepts Visa and MasterCard credit card payments. Kasco Marine will call for
credit card information upon completion of the estimate at the customer’s
request. Please see the Support section of kascomarine.com for more
information about warranty and repairs. Con-tact Kasco Marine at
715-262-4488 or
sales@kascomarine.com for additional
information and your closest Authorized Repair Center.
CONTACT US
- Kasco Marine
- 800 Deere Road
- Prescott, WI 54021
- 715.262.4488
- kascomarine.com | sales@kascomarine.com
References
- Aeration Systems & Decorative Fountain Displays | Kasco Marine
- Aeration Systems & Decorative Fountain Displays | Kasco Marine
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>