BA101 Clamping Method Manual
The positive and negative clips of the battery inspection instrument are composed of two contacts that are insulated from each other (see Figure 1). When testing, make sure that each contact is in good contact and insulated from each other.
Figure 1
The results of different connect way for the same battery
all contactor are good contacted
Negative contactor 2 is out off touch
Positive contactor 2 is out off touch
Negative contactor 1 is out off touch
Positive contactor 1 is out off touch
The test results of BA101 under different clamping ways are sheet 1:
Model
| BA101
---|---
Battery Info|
12V 55Ah 610A
Red without sawtooth (battery positive)| √| √| √| √| X| X| √
Red with sawtooth (the positive signal)| √| √| X| √| √| √|
X
Blak without sawtooth (battery negative)| √| X| √| √| √| X| √
Black with sawtooth( negative signal)| √| √| √| X| √| √|
X
√:connection normal
x:connection abnormal
Results:
Voltage
| CCA| SOH(%)| SOC(%)| Internal Resistance| Connection State
---|---|---|---|---|---
12.74V| 551CCA| 81%| 100%| 5.31m0|
connection normal
12.74V
| 92CCA| 2%| 100%| 31.85m0| connection abnormal
ClampFault|
connection error
No power
| connection error
No power|
connection error
No power
| connection error
No power|
connection error
Conclusion : Make sure that both contacts of the positive and negative clips are in good contact to get right values.