AirFree L500520.3.0 Air Purifier Instruction Manual

June 14, 2024
AirFree

AirFree L500520.3.0 Air Purifier Instruction Manual
AirFree L500520.3.0 Air Purifier

IMPORTANT SAFETY INSTRUCTIONS

  • Read operator’s manual before usage.
  • For indoor use only.
  • Double insulated electrical appliance.
  • When discarding this product, it must be sent to separate collection facilities for recovery and recycling. By separating this product from other household-type waste, the volume of waste sent to incinerators or land-fills will be reduced and natural resources will thus be conserved.

When installing and using this electrical equipment, basic safety precautions should always be followed, including the following:

READ AND FOLLOW ALL INSTRUCTIONS

  • Air free ® is not intended for use by persons with reduced physical, sensory or mental capabilities, or lack of experience or knowledge. Children should be supervised to ensure that they do not play with the appliance
  • Do not place your Airfree® in direct contact with water or liquids as it can cause an electric and harmful shock hazard and damage to the unit itself.
  • Do not obstruct Airfree® air outlets with items such as towels, clothing, curtains, as it will increase heating inside the ceramic core causing the device to shut off. If such condition persists a general cut-off system will cut power supply requiring replacement of the circuit board by an authorized dealer. This incident is not covered by the Airfree® warranty
  • Do not attempt to open Airfree® or touch its internal components. Do not insert any objects as it may cause electric shock. Any attempt to open or tamper Airfree® will void the warranty.
  • To clean Airfree®, unplug it from the electric outlet and use a dry cloth to wipe off its surface. Do not attempt to open Airfree® to clean it inside which is not necessary
  • If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons or any authorized warranty service shop to avoid potential hazard events. When returning your Airfree® for repair please make sure it is well protected preferably inside its original box, to avoid additional damages.
  • Airfree® shall not be placed near flammable and toxic products.

Installing and Connecting

  • Plug the power cord into the nearest outlet. Make sure the surface is dry (never place Airfree® on wet floor or immerge it in water). Make sure the On/Off led is on. Adjust the Night Light intensity with the touch sensor. After 30 minutes the top lid should be warm.*

  • Place Airfree® on a flat surface, not under furniture, shelves, or behind curtains as it will interfere with airflow and Airfree® efficiency in destroying microorganisms.

  • Check if the area is compatible with the unit capacity to achieve best unit performance. Using Airfree® in rooms larger than its capacity will greatly reduce its purifying capacity.

  • Airfree® must be continuously on in the same room, 24 hours a day. Nevertheless, temporarily removing it from the room will allow new microorganism contamination to grow but it will be destroyed when Airfree® is plugged in again. The longer the period without Airfree® the higher the new contamination in the room.

  • Rooms with air condition or ventilation will not affect the air sterilization efficiency of your Airfree®. Same for Heating systems.

  • Airfree® can be placed in corridors but the air sterilization effects will barely have any effect in connecting rooms.

  • Avoid place the unit near open doors or windows to prevent some of the sterilised air to exit the room.

  • SHORT POWER CORD INSTRUCTIONS
    A short power supply cord is provided to reduce the risk resulting from becoming entangled in or tripping over a longer cord. Extension cords are available and may be used if care is exercised in their use. – If an extension cord is used, the marked electrical rating of the extension cord should be at least as great as electrical rating of the appliance, and the longer cord should be arranged so that it will not drape over the counter or table top where it could be pulled on by children or tripped over unintentionally.

  • POLARIZATION INSTRUCTIONS
    This appliance has a polarized plug (one blade is wider than the other). To reduce the risk of electric shock, this plug will fit in a polarized outlet, reverse the plug. If it still does not fit, contact a qualified electrician. Do not modify the plug in any way

  • To turn the fan ON or OFF, press and hold the sensor touch button for at least 6 seconds. Top light – Press the same sensor touch button multiple times to achieve the desired light brightness or to turn it off completely.

  • For faster air sterilization select the boost mode. This function will turn on the fan on 3 different speed options to increase the air flow, usually for 1/2 hour or 1 hour.

Connecting the Airfree App

  1. Download the Airfree App to your smartphone (available for IOS and Android), or use Tuya App if you already have it. Available at the App Store and Google store.
  2. Make sure to turn the bluetooth and wi-fi on.
  3. Create a new account following the on-screen instructions.
  4. Press both the lamp and fan touch sensors at the same time, to start pairing – the fan icon will show a pink flashing light.
  5. Add the device.
  6. Once detected add the Airfree ELITE to the App devices list

App Operation:

  • Press to select light intensity.

  • Press to select the light timer.

  • Press to select fan speed.*

  • Press to select fan timer.

  • Press to check particle capsule usage-life.

  • Press to reset particle capsule life after replacing it.

  • Auto mode on ELITE II to activate Capsules when necessary. ELITE II has pollutant sensors and monitor the indoor air quality (TVOC and PM 2.5)

Remote Control
Remote Control

The infrared remote control will only work if pointed upwards to the Airfree bottom lid

Technical Characteristics
Technical Characteristics

Model ELITE
Capacity 70 m²
Electric Consumption 52 – 61 W
Voltage 220 – 240 V
Noise Totally silent with just the TSSTM ON, less than 20db, when fan in ON
Weight 3,75 lb/1,7 kg
Dimensions Height: 17.7 in / 45cm Ø: 7.3 in / 18,5 cm
Color White
Night Light Blue

**How Airfree® Works
![How Airfree®

Works](https://manuals.plus/wp-content/uploads/2023/11/Screenshot_36-147.png)
**

  1. Cooling Chamber
    Cold and clean air is delivered to the environment without any noticeable change in room temperature or humidity.

  2. TSSTM Sterilising Ceramic Core
    Inside the ceramic core, 99.99% of bacteria, viruses, mould, fungi, pet allergens, dust mite and spores are destroyed

  3. Carbon and Particle Capsules
    The capsules will remove dust, tinny particles, chemical pollution, VOCs, smoke and bad odours.

  4. Air Inlets
    Contaminated air enters through the bottom air inlets either.

Regardless of how hazardous a virus, fungus or bacteria might be they are fully destroyed by  the powerful heat inside the TSS™ ceramic core mini ducts. The heat inside the ceramic core forces sterilised air up to the heat exchanger causing air convection, which generates negative pressure underneath the ceramic core, so contaminated air is “sucked” in at Airfree® bottom air inlets in a continuous, silent, and efficient air flow.

Airfree® Description

  1. Sterilised air outlet – Top light
  2. Light intensity touch sensor
  3. Fan Speed (4 levels)
  4. Side shells
  5. Bottom air inlet
  6. Contaminated air inlet
  7. Power cord
  8. Serial Number

The top Night Light does not interfere with the TSS™ air sterilisation process of your Airfree®.

Frequently Asked Questions

1. How do I know if my Airfree® is working?

Check the top lid, if cold the sterilisation system is not working. Please connect it to another outlet and make sure the unit is in its vertical position for at least 1 minute. Also check if the fan is working when activating the “boost mode”.

2. Are there any side effects?

No. Airfree®’s new technology uses heat to purify the air with meaningless heat contribution to the room. No side effects, no emissions, NO IONS, nor new particles are generated. Airfree® can be used in homes and offices, quietly, constantly, and efficiently purifying the air.

How do I shut the Night Light off?

Touch multiple times the “bulb” icon until turn the lights OFF. You can also turn the lights OFF by using the remote control or the Airfree App.

4. The top lights are blinking. What does that mean?*

Indication that Airfree® is not correctly placed. Please make sure the device is on its vertical position

5. Should I turn off Airfree® when I leave house?

To achieve best efficiency, we recommend to keep Airfree® always on, no need to have the Fan ON. Turning the unit off will stop the sterilisation process allowing the room contamination to grow.

6. Can I change Airfree® from one room to another?

Airfree® must always be plugged in the same room 24 hours a day. Airfree®’s patented technology works gradually so, when removing it to another room the contamination in the original room will start to increase.

7. Does CADR measure the effectiveness of the Airfree®?

Not at all. CADR is not designed to test the Airfree® technology. The AHAM seal (usually found on the back of an air cleaner’s box) lists three Clean Air Delivery Rate (CADR) numbers: one for tobacco smoke, one for pollen and one for dust. The CADR indicates volume of filtered air delivered by an air cleaner. The reason why CADR is not designed for Airfree® is because Airfree® does not filter but destroys microorganisms instead, such reduction of bacteria, moulds, viruses and other microorganisms can only be measured after air sample incubation in a microbiology lab. Airfree® destroys (not trap or attract to other surface) any microorganism regardless of how small they might be. 99.99% of all microorganisms are fully destroyed when passing through the Airfree® patented ceramic core

8. What happens if Airfree® is disconnected or there was a black out?

Airfree® will take approximately the same time to recover the previous reduced contamination level.

9. Does Airfree® eliminate bacteria and viruses?

Yes. Unlike the air filters in the market Airfree® is more efficient with the smallest microorganisms as they are easily carried by Airfree®’s airflow into the sterilising TSS™ ceramic core. Please check the independent bacteria and virus tests at our website.

10. How does Airfree® eliminate fungi and moulds?

As mentioned before, Airfree® eliminates airborne microorganisms there included mouds, fungi and spores. By eliminating spores new mould colonies are unlikely to develop, representing less future airborne mould spores. Please check the independent mould tests at our website.

11. How does Airfree® destroy viruses?

Those microscopic microorganisms are easily eliminated inside Airfree®’s ceramic core capillaries. Contrary to other technologies the smallest the microorganisms the easiest they are destroyed inside the TSS™ ceramic core capillaries. Please check the independent virus test at our website.

12. Does Airfree® make any humidity level change in the room?

No.

13. Does Airfree® release any gas or chemical product?

No. Airfree®’s sterilisation process is natural. Please check our website for conclusive tests regarding particles and ozone.

14. Does Airfree® heat up a room?

Airfree® does not make any noticeable increase in the room temperature. Just for comparison two Airfree® devices plugged in the same room will contribute as much heat as one 155 lb / 70 kg adult.

15. Does Airfree® need filter replacement?

No. The TSSTM techonology designed for microorganisms doesn’t require filter. The option carbon capsule can be used only when necessary, assuring huge life.

16. Where do the microorganisms go after they are destroyed?

All living microorganisms are basically composed by carbon, oxygen an nitrogen. Since Airfree® reaches nearly 400 °F / 200 ºC, all the components decompose into carbone dioxide (the same product released by our respiration) and water. Some carbon (or microscopic ashes) may remain inside the device or over the top lid during the process. It should be noted that all happens in a microscopic level, so all those residues are a very small fraction of the microorganisms original microscopic size, in other words meaningless.

Warranty

The Commercial Guarantee Statement is sent to the customer along with the item and does not affect the customer’s rights under locally applicable laws, nor their rights with regard to the distributor/seller of this product. This product is warranted by AIRFREE® PRODUCTS, to the original purchaser to be free from defects in material and workmanship under proper use for a period of three years from date of purchase. During this period, and upon presentation of sales receipt, this product will be repaired or replaced (lack of conformity of item) with same or similar model without charges for parts or labor at distributor address, when buying your Airfree device from an authorised dealer, they will have to ensure the legal guarantee of their product. To be eligible for the warranty, please keep your sales receipt. We advice you to register your device warranty at www.airfree.com. To obtain warranty service, please send the device with sales receipt or invoice to the distributor.

The territorial scope of this guarantee is defined by the customer’s place of residence if purchased online, or the place where the purchase agreement was concluded if purchased in a physical store.

You may also ask for a proportional reduction of price or a termination of the contract if the conformity of the item cannot be restored, as provided for by law These rights must be fulfilled within a reasonable time and are not affected by any commercial guarantees. By exercising this guarantee, the customer, in addition to these rights, can also request the immediate replacement of the item or the termination of the contract if the lack of conformity becomes apparent within 30 days of delivery.

In the event of not being able to restore the conformity of the item, the consumer can choose between a proportional reduction in the price (proportional to the decrease in value of the good), or the termination of the contract through a declaration stating their decision (by letter or by email*) at the expense of the manufacturer/distributor.

This warranty does not apply to a product that has been misused, abused, or altered without limiting the afore mentioned, bending or dropping the unit, defects in the house electrical installation or fluctuating power levels that are considered to be defects resulting from misuse or abuse. The onus of proof of non-compliance in the first two years lies with the distributor/manufacturer, and thereafter on the consumer.

After the guarantee period, charges are incurred by the customer, the calculation of which is based on the following formula: Travel Expenses + Repair Expenses (Materials and Labour) + Customs Costs (if applicable)

AIRFREE® PRODUCTS and its affiliates or wholesalers do not make any specific claim as to medicinal uses of this product nor does the manufacturer warrants that the equipment prevents diseases.

NEITHER THIS WARRANTY NOR ANY WARRANTY, EXPRESSED OR IMPLIED, INCLUING IMPLIED WARRANTIES OR MERCHANTABILITY, SHALL EXTEND BEYOND THE WARANTY PERIOD. NO RESPONSIBILITY IS ASSUMED FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES, SOME STATES DO NOT ALLOW LIMITATION ON HOW LONG AN IMPLIED WARRANTY LASTS; SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, SO THE ABOVE LIMITATIONS OR EXCLUSIONS MAY NOT APPLY TO YOU. AIRFREE® PRODUCTS HEREBY SPECIFICALLY DISCLAIMS ALL EXPRESSED WARRANTIES NOT OTHERWISE SET ORTH HEREIN AND ANY IMPLIED WARRANTIES OR MERCHANTABILITY OR IMPLIED WARRANTIES FOR FITNESS FOR A PARTICULAR PURPOSE. THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION OF THE FACE HEREOF. This warranty gives you specific legal rights; you may have other rights, which vary from state to state, and country to country

*AIRFREE® PRODUCTS, Julieta Ferrão 10, 9th Floor, 1600 -131 Lisbon, Portugal
Phone 351 – 213 156 222
Fax 351 – 213 516 228
Web www.airfree.com
Email info@airfree.com

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals