WARNINGS

  • The range hood is designed and manufactured according to DS/EN 60335-1.
  • This range hood is only for use in private house holdings, if used for other purposes the warranty will be repealed.
  • Installation must be performed by a skilled electrician in accordance with the specifications given by Thermex Scandinavia A/S (Thermex) and legislation in force.
  • Thermex disclaims all responsibility in regards to damages caused by wrong installation, mounting or use.

BEFORE MOUNTING/COMMISSIONING

  • Inspect the range hood for transport damages, flaws and defects immediately after the receipt.
  • Transport damages must be filed to the haulage contractor and Thermex immediately after the receipt.
  • Flaws and defects must be filed to Thermex within 8 days the receipt, and not later than mounting/commissioning.

MOUNTING

  • The range hood is intended for working at 230 Volt ±10%~ 50 HZ in referring to EN 50160.
  • Connect the hood with the attached plug. NOTE: The hood MUST have earth if the plug has an earth connection.
  • For models with external motor applies that NOT to use common zero by installing the hood and engine, as this will affect the control.
  • It MUST be ensured that the motor can be used with the selected range hood when using an external motor from another supplier. Otherwise the warranty no longer apply.
  • Do not plug in the range hood until the mounting is complete.
  • The air must not be discharged from the hood into a pipe used for extraction from devices using gas or other fuels. Such devices must have a separate vent.
  • The national legislation on air emissions must be observed.
  • Always use the original dimension of the vent. By reducing the dimension of the vent, the performance will be reduced and the sound level will be increased.
  • The vent to the open air, must be as short as possible in order to get the greatest possible capacity of the range hood.
  • The number of bends on the vent ought to be minimized, to gain the greatest possible capacity of the range hood.
  • Thermex recommends to always use sound and condensation insulated vent hose at the carrying through in unheated spaces.
  • Thermex recommends that there is used for a muffler to minimize the noise level when using flexible hose.
  • Using the flexible hose must always ensure that this is fully extended to minimize air resistance and thereby achieve maximum absorbency.
  • Different materials takes different raw plugs and screws. Use raw plugs and screws in tented for the material the range hood is to be mounted in.
  • If the instructions for the installation of screws and fittings are not followed, it may result in electrical shock.
  • The minimum distance to gas stoves from the burner’s edge to the underside of the hood MUST be minimum 65 cm in accordance with EN 60335-2-31.
  • Thermex recommends that the space between the lower edge of the range hood and cooker is between 50 cm and 70 cm, valid for all cabinet range hoods, islands and wall mounted range hoods.
  • Always control the stated minimum distance between cooker and range hood in the manual for the cooker. If the manual for the cooker states a greater distance than what Thermex recommends the manual for the cooker MUST be followed.
  • Thermex recommends that the space between cooker and range hood does not exceed 3 meters for range hoods integrated in the ceiling

INSTALLATION

Thermex Trend 20 60 cm Extract Hood - Fig 1

Thermex Trend 20 60 cm Extract Hood - Fig 2

Thermex Trend 20 60 cm Extract Hood - Fig 3

  1. Fix the one-way-valve to the air outlet of the cooker hood.
  2. (Wall mounted) Install the L-shaped bracket on the top of the hood by two screws (4mm x 10mm)
  3. (Wall mounted) The cooker hood is wall mounted by 4 screws (4mm x 30mm) and wall plugs. Mount the cooker hood on the wall on the back of the cooker hood by 2 screws (4mm x 30mm) and wall plugs.
  4. (Cabinet mounted) Mount the cooker hood in the cabinet using 6 screws (4x35mm) and flat washers
  5. (Cabinet mounted) If there is gap between the wall and the cooker hood, you may install the L-shaped bracket on the bottom of the hood using two screws (3 x 12mm). The installation of the L-shaped bracket is optional.
  6. (Cabinet mounted) Ensure that the cooker hood is securely mounted in the cabinet.
  7. If included with your hood, mount the rubber piece on the damper flap as shown in  the illustration.
  8. Insert the damper flaps into the exhaust duct, in the mounting holes on the side.
  9. Verify that the damper flaps can open and close without any problems or difficulty.
  10. Apply the exhaust hose to the duct, along with a hose clamp.
  11. Tighten the hose clamp GENTLY around the duct to hold the exhaust hose in place. It is important not to overtighten the clamp, as this may cause problems when the damper flaps need to open. Ensure that the duct is straight without any bends or obstructions.

ELECTRIC INSTALLATIONE

MAINTENANCE AND CLEANING

  • Always disconnect power before cleaning.
  • The hood must be cleaned regularly to ensure optimal operation and long service life.
  • Grease and dust debris are collected in the filter and may risk igniting with insufficient cleaning.
  • The hood should be cleaned inside and out frequently to avoid grease stains on walls or other surfaces.

DAILY CLEANING

  • For cupboard-integrated, free-hanging and wall-mounted hoods, Thermex recommends that the grease filter be wiped with a damp cloth after each cooking session. It requires very little effort every day to keep your cooker hood clean and effective.
  • Steel surfaces are cleaned with a damp cloth with detergent and treated with 3M Polish.
  • Lacquered surfaces should be cleaned with a damp cloth with detergent/washing-up liquid. Never use abrasives.

CLEANING THE GREASE FILTERS
Grease filters should be cleaned as needed. Thermex recommends as a minimum that the filter is cleaned at the following intervals, depending on the fat used for frying:

  • Frying margarine – filter cleaned every 3 weeks
  • Liquid margarine – filter cleaned every 2 weeks
  • Oil – filter cleaned once per week
  • Deep fat frying – filter cleaned 2-3 times per week

The grease filters are cleaned in the following way:

  • Open the glass door
  • Remove the grease filter behind the glass plate and the filter in the base by pulling on the filter-locking mechanism to loosen the filter from the hood.
  • Place the filters in warm soapy water and clean if necessary with a soft brush.
  • Rinse with warm water.
  • Leave the filters to dry on a dishcloth or similar.
  • Repeat the process if necessary.
  • Re-attach the filters..

The filters can also be washed in the dishwasher, although please note that machine washing can result in discolouration of the filters. Discolouration of the filters does not affect performance.
REPLACING THE RECIRCULATION FILTERS
If recirculation filters are used, these cannot be washed, but must be replaced when needed. Thermex recommends that the recirculation filters are replaced at least 2-4 times per year.

Thermex Trend 20 60 cm Extract Hood - Fig 6

REMOTE CONTROL

Thermex Trend 20 60 cm Extract Hood - Fig 7

SERVICE

Before reporting service on your Thermex range hood, it is important that you read the installation and/or user instructions carefully. It ensures that Thermex can provide you the best possible assistance.

Service department at Thermex can be contacted in preparation to:

  • Technical support for installation and installation of your range hood.
  • Clarification of functionalities in your hood.
  • Service Request during the warranty on your hood .

Before a service request during the warranty always try to disconnect the power to the hood for about 5 min. Then plug the power back on to see if the problem is corrected.
If the problem is not corrected, disconnect the power supply to the hood for one hour. If the hood is still not functioning properly, and the troubleshooting charts are reviewed, contact the service department.
NOTE: For inquiries within the warranty, you will be asked for proof of your purchase in the form of a sales receipt. Therefore, always store your sales receipt

Before the request for service within the warranty, it is important to have all the necessary information ready:

  • Error Description
  • Model
  •  The type and serial number of the hood (on the chassis plate)
  • Information of puchase

ERROR SHEET

PROBLEM POSSIBLE CAUSE SOLUTION
The hood does not work There is no power to the hood Check the electrical

connection and fuses. Disconnect the power to the hood for 5 minutes, then reconnect the
power to see if the problem is resolved.
The hood has no electrical connection| Check that the hood is correctly con- nected to the mains and follow the installation instructions for connecting to the mains.
The hood’s suction capacity is
not sufficient| The damper does not open| Check if there is anything on the damper. Check below whether the tension band or the exhaust hose prevent the damper from opening and closing as it should.
Bent or blocked hose/channel.| Check that the exhaust hose is extended and without folds or book. The channel must not be blocked and must be free all the way out.
The filters are dirty.| Check filter and clean if necessary, see instructions.

ENVIRONMENTAL CONSIDERATIONS
PACKAGING
The packaging must be disposed of in accordance with local regulations on waste management.
SCRAPPING OF THE PRODUCT
The symbol **** on the product or accompanying documentation indicates that this product may not be disposed of as household waste but must be delivered to the nearest collection center for the recycling of electrical and electronic equipment.

THERMEX SCAndInAVIA A/S
Farøvej 30 • 9800 Hjørring • Danmark
Tlf. +45 98 92 62 33
www.thermex.dk
service@thermex.dk| THERMEX SCAndInAVIA AS
Tel. +47 22 21 90 20
www.thermex.no
service@thermex.no| THERMEX SCAndInAVIA AB
Tel. 031 340 82 00
www.thermex.se
info@thermex.se| THERMEX SCAndInAVIA S.L.U.
Noi del Sucre 42 • 08840 Viladecans •
España
Tel. +34 936 373 003
www.thermex.es
info@thermex.es| THERMEX SCAndInAVIA A/S
Puhelin +358 942 454 000
www.thermex.fi
info@thermex.fi
---|---|---|---|---


References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals