Important Safety Instructions
Read these instructions carefully and retain them for future use. If this product is passed to a third party, then these instructions must be included.
When using electrical appliances, basic safety precautions should always be followed to reduce the risk of fire, electric shock, and/or injury to persons including the following
- This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
- If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
- Prior to cleaning or other maintenance, the appliance must be disconnected from the supply mains.
- Keep children under close supervision when using the appliance in their proximity.
- Always operate the appliance on a level, stable, clean and dry surface. Never use a damaged appliance or after it was dropped! Disconnect the appliance from the outlet and contact the qualified repair centre for examination and repair.
- Do not attempt to repair the appliance yourself. In case of malfunction, contact the qualified repair centre.
- Keep the appliance 1.5 metres away from where oxygen is being administered.
- To avoid damaging the power cord, do not squash, bend or chafe it on sharp edges. Keep the power cord and appliance away from hot surfaces and open flames.
- Place the power cord in such a way that unintentional pulling or tripping over it is not possible.
- If an extension cord is used, its rating needs to be suitable for the power consumed by the appliance.
- Do not operate the appliance with wet hands or while standing on a wet floor. Do not touch the plug with wet hands.
- Do not open the appliance housing. Do not insert any foreign objects into the inside of the appliance.
- Do not pull the plug out of the outlet by the power cord. Always pull on the plug itself.
- Prevent foreign objects from entering the air inlets/ outlets.
- Disconnect the plug from the outlet when not in use, before cleaning and / or before changing attachments.
- Always switch the appliance off before disconnecting the plug from the outlet.
Symbols Explanation
- This symbol stands for “Conformité Euro penne”, which declares “Conformity with EU directives, regulations and applicable standards”. With the CE-marking, the manufacturer confirms that this product complies with applicable European directives and regulation.
- This symbol stands for “United Kingdom Conformity Assessed”. With the UKCA- marking, the manufacturer confirms that this product complies with applicable regulations and standards within Great Britain.
Intended Use
This product is intended to improve the air quality and eliminate pollutants.
- This product is intended for household use only.
- This product is intended to be used in dry indoor areas only..
Product Description
- A Temperature indicator
- B Humidity indicator
- C PM 2.5 small particles indicator
- D Filter lifetime bar
- E Air quality display
- F Air quality sensors with cover
- G Power socket
- H Detachable power cord with a plug
- I Control panel
- J Slow speed indicator
- K Filter replacement button with indicator
- L Medium speed indicator
- M Lock button with indicator
- N Fast speed indicator
- O Auto mode indicator
- P Mode select circle with air quality indicator
- Q Turbo mode indicator
- R On/off button
- S Sleep mode indicator
- T Minimum speed indicator
- U Air outlet
- V Air filter x2
- W Pre-filter x2
- X Air inlet cover x2
Before First Use
DANGER Risk of suffocation!
Keep any packaging materials away from children and pets – these materials are
a potential source of danger, e.g. suffocation.
CAUTION Risk of damage!
Before first use, remove the film packaging from the air filters (V) and peel
off the film protector from the control panel (I).
Removing the air filters (V) packaging
NOTICE
The product is equipped with 2 air filters. When removing the air filter (V)
packaging, ensure to repeat the procedure on the other side of the product.
- Remove the air filters (V) from the product (refer to 6.3 Cleaning the air filters chapter).
- Remove the air filters (V) packaging.
- Reinstall the air filter (V).
Positioning
- Ensure there is a clearance of 38 cm around the product.
- Ensure there are no objects obstructing the air inlet covers or air outlet (U).
General instructions
- Remove all the remaining packing materials.
- Remove and review all components before use.
- Check the product for transport damages.
- Before connecting the product to the power supply, check that the power supply voltage and current rating corresponds with the power supply details shown on the product rating label.
Operation
CAUION Risk of damage!
Avoid using the appliance simultaneously with a humidifier.
The wet environment produced by the humidifier has an impact on the filter
element. The mist produced by an ultrasonic humidifier may cause abnormality
in the PM2.5 detection of this appliance.
PM 2.5 is the particle matter that makes persons with asthma or other
respiratory conditions difficult to breathe.
Switching on/off
NOTICE I After plugging in, the product beeps and the control panel (I) blinks.
- To switch on the product, press the on/off button (R). The product beeps, all indicators light up white and the selected mode’s indicator lights up blue. The air quality display (E) lights up. The air quality indicator (P) lights up red, and then changes the color according to air quality (refer to 5.4 Auto mode chapter).
- To switch off the product, press the on/ off button (R) again. The product beeps and all indicators go off.
NOTICE I After selecting any mode, the mode select circle (P) lights up red next to the selected mode’s indicator to confirm the selection, and then returns to the current air quality colour.
Setting the fan speed
To set the fan speed, press on the mode select circle (P) next to the desired
fan speed indicator. After selecting the speed, the respective speed mode
indicator lights up blue.
Turbo mode
The turbo mode is the fastest fan working setting. Use this mode for quick air
pollutants and odour cleaning.
- To switch on the turbo mode, press on the mode select circle (P) next to turbo mode indicator (Q). The turbo indicator (Q) lights up blue.
- To switch off the turbo mode, press on the mode select circle (P) next to any other mode’s indicator. Turbo indicator (Q) lights up white. Other mode’s indicator lights up blue.
Auto mode
Auto mode (0) adjusts the fan speed automatically according to the current air
quality level. The colours on air quality indicator represents the air quality
level and fan speed.
- To switch on the auto mode, press on the mode select circle (P) next to the auto mode indicator (0). Auto mode indicator (0) lights up blue.
- Air quality indicator (P) colours represents
- To switch off the auto mode, press on the mode select circle (P) next to any other mode’s indicator. Auto mode indicator (0) lights up white. Other mode’s indicator lights up blue.
Air quality display (E)
NOTICE I After switching on the product, the PM 2.5 indicator (C) collects data and shows “–” for the first 10 seconds. The indicator shows the current status, thereafter.
The air quality display (E) provides information about the current air specifications and air filters (V) status.
Sleep mode
Sleep mode enables a silent product operation at night. The fan speed slows
down and other indicators go off.
- To switch on the sleep mode, press on the mode select circle (P) next to the sleep mode indicator (S). The sleep mode indicator (S) lights up blue. Other indicators go off [except for the filter replacement indicator (Kl].
- To switch off the sleep mode, press on the mode select circle (P) next to any other mode’s indicator. The sleep mode indicator (S) lights up white. Other mode’s indicator lights up blue.
Lock mode
Lock mode allows to lock all buttons. This helps to prevent accidental setting
change by e.g. a child.
NOTICE I Once in the lock mode, the product beeps and lock mode indicator (M) blinks twice after pressing any button.
- To switch on the lock mode, press and hold the lock button (M) for 3 seconds. The lock indicator (M) lights up blue.
- To switch off the lock mode, press and hold the lock button (M) for 3 seconds again. The lock indicator (M) lights up white.
Filters replacement indicator (K)
NOTICE I Clean or replace the air filters (V) immediately once the filter replacement indicator (K) lights up blue, or when the filter lifetime bar (D) has only 1 bar.
Filters replacement indicator (K) lights up blue when the air filters (V) needs to be cleaned or replaced. The filters lifetime bar (D) shows how used up are the air filters.
- Clean the air filters (V) (refer to 6.3 Cleaning the air filters chapter).
- Press and hold the filters replacement button (K) for 3 seconds to reset the air filters. The product beeps and the filters replacement indicator (K) blinks 3 times and lights up white.
- If the filters replacement indicator (K) lights up blue again, replace the air filters (V) (refer to 6.4 Replacing the air filters chapter).
Cleaning and Maintenance
WARNING Risk of electric shock!
- To prevent electric shock, unplug the product before cleaning.
- Never hold the product under running water.
Cleaning the product
- To clean the product, wipe with a soft, slightly damp cloth.
- Wipe the product dry after cleaning.
- Never use corrosive detergents, wire brushes, abrasive scourers, metal or sharp utensils to clean the product.
Cleaning the air quality sensors (F)
For optimal functioning, clean the air quality sensors (F) every 2 months.
Clean the air quality sensors (F) more frequently if using the product in
dusty or humid environment.
- Use a flat screwdriver to open the air quality sensors cover (F) (Fig. 1 ).
- Use a soft brush to clean the air quality sensors (F) and it’s cover (Fig. 2).
- Close the air sensors quality’s cover (F).
Cleaning the air filters (V)
CAUTION Risk of damage!
Clean the outer side of the air filters (V) only.
NOTICE I The product is equipped with 2 air filters. When cleaning the air filter (V), ensure to repeat the procedure on the other side of the product.
For optimal functioning clean the air filters (V) every 2 weeks.
-
Unplug the power cord (H) from the socket outlet.
-
Press on the push signs on the air inlet cover (Fig. 3).
-
Remove the pre-filter (W).
-
Move the filter latch to the anti-clockwise to unlock (step 1, Fig. 4). Remove the air filter (V)(step 2, Fig. 4).
-
Use a vacuum cleaner to remove the dirt from the outer side of the air filter (VJ and the prefilter (W) (Fig. 5).
-
Use a vacuum cleaner to remove the dirt from the air inlet cover (X).
-
Reinstall the air filter (VJ. Move the air filter latch clockwise to lock (Fig. 6).
-
Reinstall the pre-filter (W).
-
Close the air inlet cover (X).
-
Repeat on the other side of the product.
-
If the filter replacement indicator (K) lights up blue, press and hold the filter replacement button (K) for 3 seconds to reset the filter.
The product beeps and the filter replacement button (K) blinks 3 times and lights up white. -
If the air filter replacement indicator (K) lights up again blue, replace the air filters (V) (refer to 6.4 Replacing the air filter chapter).
Replacing the air filters (V)
- NOTICE I Filters must be checked for function and wear at regular intervals.
- NOTICE I The product is equipped with 2 air filters. When replacing the air filter (V), ensure to repeat the procedure on the other side of the product.
Replace the air filter (V)
- In every 6-8 months depending on the use and environment.
- If you experience increased operating noise, decreased airflow or increased odour level. When the filter lifetime bar (DJ shows 1 bar.
NOTICE I Depending on the environment (level of air contamination), and the selected operation mode, the filter may degrade considerably early. Look for early signs that filter might need replacement.
- Unplug the power cord (HJ from the socket outlet.
- Press on the push signs on the air filter’s cover (Fig. 3).
- Remove the pre-filter (W).
- Move the filter latch anti-clockwise to unlock (step 1, Fig. 4). Remove the air filter (V) (step 2, Fig. 4).
- Replace the air filter (V). Move the air filter latch clockwise to lock.
- Reinstall the pre-filter (W).
- Close the air inlet cover (X).
- Repeat on the other side of the product.
- Press and hold the filter replacement button
(Kl for 3 seconds to reset the filter. The product beeps and the filter replacement button (K) blinks 3 times and lights up white. The filter lifetime bar (D) shows 5 bars.
Storage
- Store the product in its original packaging in a dry area. Keep away from children and pets.
- Store the air filter (V) clean and sealed in a plastic bag.
Plug fuse replacement (for UK only)
- Use a flat screwdriver to open the fuse compartment cover.
- Remove the fuse and replace with the same type (3A, BS 1363). Refit the cover.
Maintenance
Any other servicing than mentioned in this manual should be performed by a professional repair centre.
Troubleshooting
Filters Disposal
Dispose the filters accordingly to the local regulations at specified disposal
facilities. The filter can be disposed together with household rubbish.
Disposal
‘g The Waste Electrical and Electronic Equipment (WEEE) Directive aims to
minimise the impact of A electrical and electronic goods on the environment,
by increasing re-use and recycling and by reducing the amount of WEEE going to
landfill. The symbol on this product or its packaging signifies that this
product must be disposed separately from ordinary household wastes at its end
of life. Be aware that this is your responsibility to dispose of electronic
equipment at recycling centres in order to conserve natural resources. Each
country should have its collection centres for electrical and electronic
equipment recycling. For information about your recycling drop off area,
please contact your related electrical and electronic equipment waste
management authority, your local city office, or your household waste disposal
service.
Specifications
Importer Information
- amazon.com/AmazonBasics
- MADE IN CHINA
- V03-01/23
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>