KLINGER BORN ASB20-05-230 Electronic Add On Brake Instruction Manual
- June 14, 2024
- KLINGER BORN
Table of Contents
KLINGER BORN ASB20-05-230 Electronic Add-On Brake
Dear customer,
thank you for purchasing this article. This article complies with the
requirements of the pertinent European and national directives. CE conformity
has been demonstrated. To maintain the condition of this article as delivered
and to ensure safe operation, you, the user, must observe this manual. Read
the entire manual before putting the article into service and observe all
operational and safety notices. All information on technical data and
properties is non-binding. In the interest of technical advancement, we
reserve the right to change at any time.
Safety Instructions
Please observe the following rules! This manual belongs to the product. It contains important information on the initial operation and use of the product. When you transfer this product to a third party, remember to include this manual. Keep this manual for further reference. Any damage caused by failure to comply with this manual will void the warranty. We will not bear liability for consequential damage.
- When connecting the device and putting it into service, the user must comply with all legal and technical provisions, including but not limited to VDE0100, VDE0113 (EN60204), VDE0660, etc.
- For reasons of safety and approval (CE), unauthorized modifications of and changes to the product are not allowed. Never disassemble the product.
- This device is sealed. Breaking the seal by opening the housing voids the warranty.
- Do not put into service any devices with a visibly damaged mains cable, motor cable, or switch.
- Pull the mains plug or the backup fuse before connecting wires or carrying out maintenance, setting-up, or repair work.
- Wait for rotating masses like saw blades, planer blades, drill chucks, and other revolving parts to come to a standstill.
- Live parts may remain live even after the mains plug has been disconnected for a while.
- Check the mains supply before connecting. Wrong connections may destroy electric equipment. Observe line voltage: The information on the type plate must conform with the data of the power supply.
- Electric equipment may only be operated on a mains supply that is sufficiently protected against overcurrent.
- The ASB20 may not be operated on power from a generator with a non-stable output frequency (under load). Doing so may destroy the device.
- Before leaving the machine without supervision for an extended work break and before shutting down the machine, disconnect the device from the main supply.
- Only qualified technical personnel may adjust the braking time.
- Avoid short switching cycles. The enormous thermic load caused by frequent starting may damage the motor, the device, and the electronic control PCB.
- For use in commercial facilities observe the accident prevention regulations for electric systems and equipment by the Association of the Industrial Employer’s Liability Insurance Associations (Verband der gewer blichen Berufsgenossenschaften).
- Operation of the product in schools, training facilities, hobby, and DIY workshops must be supervised by trained personnel.
- Handle the product with care. Impact, shock, or a drop from a low height will damage the product. Never use the product after it has been moved from a cold room to a warm room.
- Water condensation may destroy the product. The device needs to adapt to room temperature before you connect it to the main supply. This may take several hours.
- Never touch the product with wet or moist hands.
- Make sure that the isolation of the entire product is neither damaged nor destroyed.
- At the place of installation and during shipping avoid the following environmental conditions: moisture or excessive air humidity, extreme cold or heat, dust or flammable gases, vapors or solvents, strong vibrations, and strong magnetic fields as can be found near machines or loudspeakers.
Technical Data and Article Numbers
Versions ASB20
Braking current| Operating voltage| Motoren kw (1)|
Standstill- detection| Fix braking time| Designation|
Art.No.
---|---|---|---|---|---|---
1-5A| 230V| 0,18…0,75| Yes| –| ASB20/05/230| 8700.0219
1-5A| 400V| 0,18…0,75| Yes| –| ASB20/05/400| 8700.0220
1-5A| 230V| 0,18…0,75| No| 5s| ASB20/05/FB5/230| 8700.0221
1-5A| 400V| 0,18…0,75| No| 5s| ASB20/05/FB5/400| 8700.0222
1-5A| 230V| 0,18…0,75| No| 10s| ASB20/05/FB10/230| 8700.0223
1-5A| 400V| 0,18…0,75| No| 10s| ASB20/05/FB10/400| 8700.0224
4-10A| 230V| 0,75…2,2| Ýes| –| ASB20/10/230| 8700.0203
4-10A| 230V| 0,75…2,2| Ýes| –| ASB20/10/400| 8700.0204
4-10A| 230V| 0,75…2,2| No| 5s| ASB20/10/FB5/230| 8700.0217
4-10A| 400V| 0,75…2,2| No| 5s| ASB20/10/FB5/400| 8700.0218
4-10A| 230V| 0,75…2,2| No| 10s| ASB20/10/FB10/230| 8700.0211
4-10A| 400V| 0,75…2,2| No| 10s| ASB20/10/FB10/400| 8700.0212
6-20A| 230V| 1,5…7,5| Yes| –| ASB20/20/230| 8700.0202
6-20A| 400V| 1,5…7,5| Yes| –| ASB20/20/400| 8700.0204
6-20A| 230V| 1,5…7,5| No| 5s| ASB20/20/FB5/230| 8700.0213
6-20A| 400V| 1,5…7,5| No| 5s| ASB20/20/FB5/400| 8700.0214
6-20A| 230V| 1,5…7,5| No| 10s| ASB20/20/FB10/230| 8700.0206
6-20A| 400V| 1,5…7,5| No| 10s| ASB20/20/FB10/400| 8700.0207
10-30A| 230V| 5,5…11| Yes| –| ASB20/30/230| 8700.0250
10-30A| 400V| 5,5…11| Yes| –| ASB20/30/400| 8700.0251
10-30A| 230V| 5,5…11| No| 5s| ASB20/30/FB5/230| 8700.0256
10-30A| 400V| 5,5…11| No| 5s| ASB20/30/FB5/400| 8700.0257
10-30A| 230V| 5,5…11| No| 10s| ASB20/30/FB10/230| 8700.0254
10-30A| 400V| 5,5…11| No| 10s| ASB20/30/FB10/400| 8700.0255
Versions ASB20/S
Braking current| Operating voltage| Motoren kw (1)|
Standstill- detection| Fix braking time| Designation|
Art.No.
---|---|---|---|---|---|---
1-5A| 230V| 0,18…0,75| Yes| –| ASB20/S/05/230| 8700.1219
1-5A| 400V| 0,18…0,75| Yes| –| ASB20/S/05/400| 8700.1220
1-5A| 230V| 0,18…0,75| No| 5s| ASB20/S/05/FB5/230| 8700.1221
1-5A| 400V| 0,18…0,75| No| 5s| ASB20/S/05/FB5/400| 8700.1222
1-5A| 230V| 0,18…0,75| No| 10s| ASB20/S/05/FB10/230| 8700.1223
1-5A| 400V| 0,18…0,75| No| 10s| ASB20/S/05/FB10/400| 8700.1224
4-10A| 230V| 0,75…2,2| Yes| –| ASB20/S/10/230| 8700.1203
4-10A| 400V| 0,75…2,2| Yes| –| ASB20/S/10/400| 8700.1205
4-10A| 230V| 0,75…2,2| No| 5s| ASB20/S/10/FB5/230| 8700.1217
4-10A| 400V| 0,75…2,2| No| 5s| ASB20/S/10/FB5/400| 8700.1218
4-10A| 230V| 0,75…2,2| No| 10s| ASB20/S/10/FB10/230| 8700.1211
4-10A| 400V| 0,75…2,2| No| 10s| ASB20/S/10/FB10/400| 8700.1212
6-20A| 230V| 1,5…7,5| Yes| –| ASB20/S/20/230| 8700.1202
6-20A| 400V| 1,5…7,5| Yes| –| ASB20/S/20/400| 8700.1204
6-20A| 230V| 1,5…7,5| No| 5s| ASB20/S/20/FB5/230| 8700.1213
6-20A| 400V| 1,5…7,5| No| 5s| ASB20/S/20/FB5/400| 8700.1214
6-20A| 230V| 1,5…7,5| No| 10s| ASB20/S/20/FB10/230| 8700.1206
6-20A| 400V| 1,5…7,5| No| 10s| ASB20/S/20/FB10/400| 8700.1207
10-30A| 230V| 5,5…11| Yes| –| ASB20/S/30/230| 8700.1250
10-30A| 400V| 5,5…11| Yes| –| ASB20/S/30/400| 8700.1251
10-30A| 230V| 5,5…11| No| 5s| ASB20/S/30/FB5/230| 8700.1256
10-30A| 400V| 5,5…11| No| 5s| ASB20/S/30/FB5/400| 8700.1257
10-30A| 230V| 5,5…11| No| 10s| ASB20/S/30/FB10/230| 8700.1254
10-30A| 400V| 5,5…11| No| 10s| ASB20/S/30/FB10/400| 8700.1255
- Standard type
- Nur Richtwerte – Abhängig von angetriebener Masse
Special features
- DC brake with controlled braking current up to 20 A
- Delayed add-on of braking current
- Release of the motor after stand-still detection
- Automatic adjustment of the braking time through stand-still detection
- Repeatable adjustment of the braking current
- Automatic adjustment to motor resistance
- Least thermal charge of the motor
- Overload protection (optional, no short-circuit protection)
- Error detection with automatic shutdown
- Connection with spring-clamp terminals
- LED display for operation mode
- BG-Prüfzert in accordance to GS-HO-01
For use in
Saws, centrifugals, woodworking machines, balancing machines, etc.
Functional description
Due to the zero stand-still detection of the add-on brake ASB20, it is only the braking current to set. The current controller regulates the brake from any thermal change of the motor resistance so that it is always about the same braking duration achieved. Similarly, fluctuations in the production of motor winding will balanced. The standstill detection dynamically adapts to different engine sizes in star or delta connection. No further adjustment is necessary. If the stand-still is detected, it still flows for an optimized delayed braking time of only 0.5 s, a brake current through the motor.
The device monitors the standards of the professional association in
accordance with GS-HO-01 with respect to braking times and error detection. If
by incorrect setting of the braking current, overload, or aging, the
maximum braking time exceeds 10 several times, the brake shuts down the
machine. If braking occurs in the correct time window after the first or
second detected braking time error of 10s, the error will be reset.
If the required braking time is more than 14s, the brake switch off
immediately. The engine runs on in this case. A restart is prevented. Both
locks are released by a power interruption.
Additionally, the brake monitors the internal power semiconductor and the external circuitry. The current regulator prevents the acceleration of the current at overload. The sensor detects any interruption of the brake circuit and prevents another startup. If the controller is connected to the network, the brake completes a short self-test. During this test for about 200ms, the braking power is on. After about 0.5 seconds the controller is ready for an engine start.
Block diagram
Install note
There must be a minimum vertical clearance of 30 mm between the ASB20 and the
wall of the housing to prevent heat accumulation. Mount the ASB20 on a 35 mm
DIN rail. Slide the ASB20 into the upper part of the rail and then apply light
downward pressure until it snaps into place. When removing the device, use a
tool to unlock the clip-on mechanism. Ensure sufficient ventilation when the
ASB20 is installed inside a housing or a control cabinet. The inside
temperature must not exceed 40 degrees. In critical cases provide a fan in the
cabinet.
Connection
The device must be connected by a qualified electrician and in compliance with
the pertinent safety regulations.
Port | Description |
---|---|
SE | Motor connection for stand-still detection |
SP | Control signal for brake |
NC | Control output for special function |
COM | Relais-relays COM (base point) |
NO | Control release |
EC + E | Potential-free contact for ext. error message |
Connect the ASB20 as follows
(see the description at the bottom of this page too) It is mandatory to ground
the motor. The ASB20 / ASB20/S works with star and delta connection motors.
Refer to the motor documentation for the correct connection method. Wrong
connections may destroy the motor. Use the provided spring clamp terminals to
connect the device. Use a screwdriver with a maximum blade width of 3.5 mm or
the optionally available tool to open the clamps. Strip 8- 9 mm of the wires
for the load circuit and 5-6 mm of the wires for the control circuit and
insert the bare wire end into the clamp (see picture). Remove the screwdriver
to close the clamp.
Putting into service
After the proper connection can now be put into operation ASB20 and ASB20/S.
During connection, it is imperative to connect the COM and NO release relay in
the control group the motor contactor is included!
The brake must not be operated on an isolation transformer! If the brake in
conjunction with our soft starter is used, be sure to pay attention to the
order of the connections.
Control panel
LED-Display
LED- Display | Description |
---|
Red LED glows for short time
after switching-on the mains supply
| Normal operation display, Device initializing
Green LED glows| Stand-still or actuated motor, normal operating mode
Green LED flashes| Motor brakes
Red LED glows| Error indication through:
– Excessed braking time
– Disrupted power supply
– Error during test braking after switching on
Red LED flashes and flashing output signal to EC-E (potential-free contact)| – flashes when the braking time is exceeded Option with temperature monitoring:
flashes when the temperature is too high
Failures and Corrective
If a fault occurs, the red LED lights up permanently and a new start is not possible. Fix the lock by disconnecting the power supply for about 2 seconds. The cause of the disorder may be due to the following:
Failures | Causes and Correctives |
---|
Braking time is over 14 seconds.
In this case, the switch-on lock occurs immediately.
| Improve the braking power so far that the engine stops under 10 seconds
The braking time is between 10 and 14 seconds. This is shown by blinking of
the red LED and a flashing output signal at EC-E. The switch-on lock occurs
after the third braking. The fault is reset when the braking time is below 10
seconds again.| Improve the braking power so far that the engine stops under
10 seconds
The motor cannot start (without error)| – Brake or mains circuit wrong
connected
Please check wiring
– Mains supply incorrect
Check mains supply (fuse and so on)
– Brake defect
Send back device
Error occurs immediately when switched on| – Brake circuit (C or V) wrong connected
Check wiring
– Incorrect device selection
– Brake defect
Send back device
The engine starts, but then it don’t brakes. Unit indicates error.| – Connection for stand-still detection is wrong (SE or C)
Check wiring
– Brake defect
Send back device
Trouble for no apparent reason – red LED glows| – The cause could be due to a short performance from the network fault
Error message by interrupting the power supply reset of about 2 seconds. Possibly. caused the disorder to another device on the same circuit.
Red LED flashes| – Switching frequency or braking currents too high.
Let the system cool down for 10 minutes.
Dimension drawing
Circuit diagram – example for 1Ph-230V, ASB20/S
Circuit diagram – example for 3Ph-400V, ASB20/S
(Uc: 230V – with neutral wire)
Circuit diagram – example for 3Ph-400V, ASB20
Declaration of Conformity
We – Klinger & Born GmbH, In den Schlangenäckern 5, D-64395 Brensbach – declare in our sole responsibility that the product
- ASB20
- ASB20/S
- for which this declaration is pertinent, complies with the following standards or normative documents:
- DIN EN 60204 Abs. 9.2.5.4.2 Stillsetzen im Notfall in der Kategorie 1
- GS-HO-01
The stipulations of the following directives are pertinent
Directive 2006/95/EC
EC EMC Directive 2004/108/EC
Relevant norms:
Fault-free operation/Emitted interference
EN60947-4-2:2007-09
The component that we supply is exclusively intended for installation in or on
a machine. It must not be put into service unless and until it has been
determined that the machine in which the component is installed complies with
the pertinent stipulations of the EC Directive. In case of questions consult
our technical service:
Klinger & Born GmbH
Germany
Phone +49 (0) 6161 – 9309 – 0
Fax +49 (0) 6161 – 9309 – 10
Internet: www.klibo.de
Email: mail@klibo.de
Monday through Friday 8 a.m. to. 4.15 p.m. All company names and product
designations in this document are trademarks of their respective owners. All
rights reserved.