Abestorm 720CFM High Air Flow Crawlspace Ventilation Fan User Manual
- June 14, 2024
- ABESTORM
Table of Contents
- 720CFM High Air Flow Crawlspace Ventilation Fan
- SPECIFICATIONS
- DESCRIPTION
- PRECAUTIONS
- REQUIRED TOOLS
- INSTALLATION
- MOUING PLATE TRIM DIMENSIONS
- FREEZE PROTECTION THERMOSTATIC ACTIVATION RANGE
- FAULT DESCRIPTION
- GENERAL INFORMATION
- WARRANTY
- IDENTIFICATION
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
User’s Manual
NeatyFresh 260
NeatyFresh 540
NeatyFresh 720
720CFM High Air Flow Crawlspace Ventilation Fan
BEFORE INSTALLING THE PRODUCT, ENSURE THAT YOU GO THROUGH THIS DESCRIPTION.
INSTRUCTIONS TO THIS EQUIPMENT MUST BE ADHERED TO. FAILURE TO DO SO CAN CAUSE
HARM.
Note: as we keep upgrading our product, we reserve the right to modify
the product without notice in advance.
SPECIFICATIONS
| Capacity:
————————-260 CFM
Motor: ———– 115V AC~ 50/60Hz 0.25A
Thermostat: ——ON at 50°F / OFF at 35°F
Dehumidistat: ——-10% – 80% RH Range
Dimensions: ————–13 1/3″ x 2 ½” x 9″
Mounting Plate Smallest Adjustable
Dimensions: ———————.9 1/3″ x 7″
---|---
| Capacity: ————————-540 CFM
Motor: ———– 115V AC~ 50/60Hz 0.51A
Thermostat: ——ON at 50°F / OFF at 35°F
Dehumidistat: ——-10% – 80% RH Range
Dimensions: ————15″ x 2 4/5″ x 10 1/5″
Mounting Plate Smallest Adjustable
Dimensions: ———————– 12″ x 9″
| Capacity: ————————-/20
CFM
Motors: ———– 115V AC~ 50/60Hz 0.7A
Thermostat: ——ON at 50°F / OFF at 35°F
Dehumidistat: ——–10% – 80% RH Range
Dimensions: ————.16 ½” x 4 1/5″ x 11″
Mounting Plate Smallest Adjustable
Dimensions: —————–13 2/5″ x 10 1/5″
DESCRIPTION
The Abestorm crawlspace ventilator series is designed to circulate fresh
outdoor air under the house and porch. Excessive humidity in crawl Spaces is a
major cause of premature decay of support columns, joists, floors and beam
supports. Humidity can promote fungal growth and increase termite activity.
Humidity can also cause pipes to rust, corrode and fail, Continuous operations
help release radon gas, treated wood exhaust and other odors that may migrate
to living areas. NeatyFresh 260,NeatyFresh 540,and NeatyFresh 720 are equipped
with a humidity switch. If the relative humidity rises above a selected set
value, the dehumidifier will start the fan.
IMPORTANT: All models are equipped with factory pre-installed thermostats
to prevent fan operation when outdoor temperatures fall below 35°F. When the
outdoor temperature rises to near 50°F, the fan will return to normal
operation.
Protection level: IP55. Our motor has better dust proof and water proof
performance.
Al three crawlspace ventilators are also equipped with stainless steel insect
mesh to more effectively block crawlers from entering the fan and the room.
(For example, crustaceans and reptiles with bodies larger than 0.14 inches.)
PRECAUTIONS
WARNING!
Crawlspace ventilator fan must be installed by qualified installers in
accordance with these instructions and all local codes o, in the absence of
such codes, in accordance with the latest version of the International Housing
Code and the International Electrical Code. Improper installation may result
in dangerous situations such as fire, electric shock, or personal injury. To
significantly reduce these risks, use the device only in the manner specified
by the manufacturer.
If you have any questions, please contact Abestorm. Always disconnect the
crawlspace ventilator before installation and maintenance.
Note:
- For general ventilation only. Do not use to vent dangerous or explosive substances and vapors
- Disconnect power supply before servicing or replacing fans
- Keep fingers, tools, clothing, and other foreign material away from fan blades.
WARNING: To reduce the risk of fire or electric shock, do not use this fan with any solid state speed control equipment.
REQUIRED TOOLS
- 5/16″ Nut Driver or flathead screwdriver.
- Drill with 5/16″ masonry bit if mounting on brick or foundation block.
- Grounded electrical outlet within 6 feet of ventilator location.
INSTALLATION
Location: Install crawlspace ventilation in the crawl space behind the
existing base ventilation hole. Vents should be installed a minimum of 3 feet
from the corner of a building
Note: Crawlspace fans must be installed in electrical control boxes and
motors facing inside the crawlspace.
- Remove the cover of existing doors or ventilation holes around the building
- Place the crawl space ventilator above the vent
- If mounted on a base block or brick, mark positions at the four comers of the metal panel and drill 5/16″ holes with a masonry bit. Install wall anchors at the opening and secure the crawlspace ventilator to the wall with 4 screws.
- If installed on a mesh of wood aggregate, edge joists, or existing crawlspace vents, secure crawl space vents with screws, washers, and nuts at the four corners of the metal panel of the vent.
The installation diagram is attached below (as shown in the picture)
MOUING PLATE TRIM DIMENSIONS
If the mounting plate needs to be modified to fit the opening, the following
decoration recommendations should be followed.
NOTE: Be careful when trimming the mounting plate to avoid damage to the
power cord, and wear protective equipment to avoid scratches!
NOTE: The above operation is only for the minimum size that needs to be cut, if any damage and failure, the company will not bear any responsibility!
FREEZE PROTECTION THERMOSTATIC ACTIVATION RANGE
IMPORTANT: All models are equipped with factory pre-installed thermostats
to prevent fan operation when outdoor temperatures fall below 35°F.
NOTE: The dehumidifier control will not operate if the freezer protection
thermostat detects a low outdoor temperature.
FAULT DESCRIPTION
Question: What may cause the fan to stop?
Answer:
-
First check whether the crawling space reaches the humidity you set or the fan shuts down due to the low outdoor temperature.
If it is the above two cases, please reset your fan. -
Check whether your circuit is normal and whether the machine is properly connected to the circuit.
Question: What is the reason for the sudden noise when the fan has been
in normal use?
Answer:
- Check whether there is any foreign matter inside the fan, which may cause the noise caused by impacting the wheel blade.
- Check whether the mounting plate is securely assembled. Loose screws and unstable mounting plates may cause noise.
Question: Why is the exhaust air volume obviously lower than before?
Answer:
- The air inlet or air outlet of the fan may be blocked by objects. Please check your use space and the space outside the air outlet.
- Check whether your current and voltage are in standard state.
If the above answers do not solve your problem, please contact us.
GENERAL INFORMATION
Each NeatyFresh crawlspace ventilator fan s electrically factory-tested prior
to shipment. After unpacking, inspect the goods thoroughly for damage. The fan
should turn freely and all wires and connections should be firm.
If any damage is found, immediately notify the carrier and your reseller and
submit a hidden damage claim.
WARRANTY
ABESTORM TWO YEARS LIMITED WARRANTY
Abestorm warrants to the original purchaser of this product that the product
will be free from defects due to faulty material or workmanship for a period
of (2) years from the date of original purchase or delivery to the original
purchaser, whichever is earlier.
Remedies under this warranty are limited to repairing or replacing, at our
option, any product which shall, within the above stated warranty period, be
returned to Abestorm at the address listed below, postage prepaid.
THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE
HEREOF, AND ABESTORM EXPRESSLY DISCLAIMS LIABILITY FOR INCIDENTAL OR
CONSEQUENTIAL DAMAGES ARISING FROM THE USE OF THIS PRODUCT. THIS WARRANTY IS
IN LIEU OF ALL OTHER EXPRESS WARRANTIES AND NO AGENT IS AUTHORIZED TO ASSUME
FOR US ANY LIABILITY ADDITIONAL TO THOSE SET FORTH IN THIS LIMITED WARRANTY.
IMPLIED WARRANTIES ARE LIMITED TO THE STATED DURATION OF THIS LIMITED
WARRANTY.
Some states do not allow limitation on how long an implied warranty lasts, so
that limitation may not apply to you. In addition, some states do not allow
the exclusion or limitation of incidental or consequential damages, so that
above limitation or exclusion may not apply to you. This warranty gives you
specific legal rights and you may also have other rights which may vary from
State to State.
Send all inquiries regarding warranty work to Abestorm.
IMPORTANT NOTICE: Keep the item’s packaging in case warranty service is
required.
IDENTIFICATION
Congratulations on purchasing a Abestorm crawlspace ventilator series For your convenience in submitting a warranty claim in the future, be sure to note the serial and the date of purchase below.
Serial Numbe:…………
Date of Purchase:…………
Abestorm Solutions INC.
Add: 8605 SANTA MONICA BLVD#79525
WEST HOLLYWOOD, California, 90069 USA
E-mail: sales@abestorm.com