Specification
Card types| 1. EM compatible 64 bits, ASK Manchester coding
2. ISO 14443A MI fare® MF1 1K&4K / Ultralight / Desire
*Read Only
(For Unique Serial Number / Unique Identifier)
---|---
Frequency| 125KHz (65.78dBuV/m), 13.56MHz (57.79dBuV/m)
Reading distance| 50 mm @ 125KHz (depends on TAG) 40 mm @ 13.56MHz
(depends on TAG)
Interface| USB-HID (USB-HID Keyboard),
USB-CDC (Communication Device Class)
Power requirement| DC 5V / 200mA、Standby: 50mA
Certificate| CE、FCC
Dimension| 120(L) x 86(W) x 42(H) mm
Weight| 170g
Operating temperature| 0 to 50 degree C
Storage temperature| -10 to 60 degree C
Humidity| 10 ~ 90%
Accessories
Main Unit (PCR340)
USB Cable USB-A to USB-C (WAS-T1214)
Please download software or user guide from following link.
http://ftp.gigatms.com.tw/public/disks/disk5274/ Scan QR code with your
phone
TM921294-15
FTP Link Paper Configuration Software (DISK5274)
Getting Started
Power / Signal port
The power is from USB connection.
Reaction panel
Put the card on reaction panel to read the card information.
Status LED
Status | Power LED | Read LED | Read Card | Buzzer Sound |
---|---|---|---|---|
Power on | Blink twice | Off | X | Blink twice |
Ready | On | Off | O | X |
Read ok | On | Blink Once (Green) | X | Blink Once |
Firmware
Management mode| Off| On (Red)| X| X
Important Instructions
- To reach the ideal performance, please keep PCR340 away from the other RFID readers at about 50 cm while PCR340 is under the operation to avoid the interference.
- Once continuous card reading is completed, wait for a while until Read LED goes off to access the next card reading.
- Before starting your computer, do not put RFID card on the reaction panel to avoid the error.
Configuring PCR340 with the Configuration Software
The configuration software (PCR Dual Setup) is in FTP LINK Disk5274. Install
the software and USB driver first. Connect PCR340 with your computer through
USB port and then run the software.
The main page of the configuration software
Step 1. Auto Scan
Click [Auto Scan] to connect PCR340-50 with your computer. If the connection
is successful, it will show “Found a reader” message and the product
information as below.
Step 2. MISC
Click [MISC]. Set [Language] (Keyboard type), [Tag Frequency], [USB
Interface], [Using code matching to right numeral part of keyboard] and
[Buzzer Enabled] if necessary. Then click [Write] to save the settings to
PCR340-50.
Step 3. ID Filter
Click [ID Filter] to set the card format of data output that you want
PCR340-50 to send. Select the [Card Type] and set [Range] and [Length] of data
information. Then click [Write] to save the settings to PCR340-50.
Step 4. Format
Click [Format]. Set [Prefix] code, [Postfix] code, [On Remove] message and
[Delimiter] if necessary. If you want PCR340-50 to send the card type when the
card is read, check [Display Card Type] checkbox. Then click [Write] to save
the settings to PCR340-50.
Step 5. Convert Table
If you want PCR340-50 to show alphabetical string instead of card number,
click [Convert Table] to edit the message you like by the following
procedures.
-
Click [Format] and check [Output by String Table] checkbox.
-
Click [Convert Table] and add a card to the table.• Card ID: If [Card ID] checkbox is checked, it indicates the card number will be converted to the string you set. If [Card ID] checkbox is unchecked, it indicates the card number will not be converted.
• Read: When you put a card on PCR340-50, the card number and card type will be shown in the boxes if you click [Read].
• Auto Read: If [Auto Read] checkbox is checked, when you put a card on PCR340-50, the card number and card type will be shown in the boxes automatically.
• You can enter the card number and select [Card Type] manually without putting the card on PCR340-50.
• Output: Enter the string you want the card number to be converted in [Output] box.
• Add: Click [Add] to add the setting for the card number to the table. -
Select the item you want to edit and change the setting and then click [Modify] if you want to edit the setting.
-
Select the item you want to delete from the table and then click [Remove] if you want to remove it.
Step 6. Save
Click [Save] to save all settings as a txt file if necessary.
Step 7. Open
If you want to load the settings form the file to PCR340-50, click [Open] to
open the file and then click [Write] to load the settings to PCR340-50.
Step 8. Read
Click [Read] if you want to know the current settings of PCR340. The settings
will be gotten and shown in the software window.
Step 9. Default
Click [Default] to reset PCR340 if necessary. The followings are the default
values.
Default Values
Item| Description
Language| USA
Tag Frequency| LF + HF
USB Interface| HID
Keyboard Output| Enable
Using code matching to right numeral part of keyboard| Disable
Buzzer Enable| Enable
Prefix| Empty
Postfix| Empty
On Remove| Empty
Delimiter| CR+LF
Display Card Type| Disable
Output by String Table| Disable
Card ID Filter| Card Type| Numeric System| From
Character| Number of Characters
MI fare 1K| HEX| 1| 8
DEC| 1| 10
MI fare 4K| HEX| 1| 8
DEC| 1| 10
Ultra Light| HEX| 1| 14
DEC| 1| 18
Des Fire| HEX| 1| 14
DEC| 1| 18
125KHz EM| HEX| 1| 10
DEC| 1| 14
Command and Packet Format
Packet format
PC →PCR340
STX | CMD | CONTENTS | CHECKSUM | CR |
---|---|---|---|---|
1 character | 1 character | 3 character | 1 character | 1 character |
PC ←PCR340
STX | REPLY | CONTENTS | CHECKSUM | CR |
---|---|---|---|---|
1 character | 1 character | 3 character | 1 character | 1 character |
Functional command
ITEM | Dec | Hex | Function |
---|---|---|---|
STX | 2 | 02 | Start for test |
CMD | ASCII | ASCII | Command code |
CONTENTS | ASCII | ASCII | Contents data |
CHECKSUM | ASCII | ASCII | Check sum |
REPLY | 65 | 41 | Acknowledge |
CR | 13 | 0D | Carriage return |
Instruction command
Command | ASCII | Description |
---|---|---|
C | 43H | Set Register |
B | 42H | Get Register |
V | 56H | Get Firmware Version |
D | 44H | Get Product Name |
X | 58H | ISP Mode |
Y | 59H | Show Memory Data |
Ack command
Command | ASCII | Contents | Description |
---|---|---|---|
A | 41H | Reply information | ACK + Information |
N | 4EH | ERROR Index Table | NCK + Information |
Error index
Topic | Error index | Description |
---|---|---|
Access LEVEL | 00 | Access Denied or Password Error |
COMMAND CODE | 01 | Command packet is too long |
02 | Command packet is empty | |
03 | Command code is out of range | |
04 | Illegal Command or Data | |
DATABASE | 05 | Database and Register is Empty |
06 | Record number is out of range | |
07 | Check Sum Error | |
08 | Memory Not Enough | |
09 | Action Failure | |
FILE | 0A | File Not Exist |
Command notation
Write to register
(‘C’ + 43H
PC→PCR340| STX +’ C ’ + Register address +’ ,’+ Write parameter + CHECKSUM +
CR
---|---
PC←PCR340| STX + ACK + CR
For Instance:
PC→PCR340 | 02 + C + 00 + ,+ FF + 5B + 0D |
---|---|
PC←PCR340 | 02 + A + 0D |
Read from register (‘B’ »+ 42H)
PC→PCR340 | STX + ‘ B ‘ + Register address + CR |
---|---|
PC←PCR340 | STX + ACK + Read parameter + Checksum +CR |
For Instance:
PC→PCR340 | 02 +’ B ‘+ 00 + 0D |
---|---|
PC←PCR340 | 02 + A + FF + CD + 0D |
Get F/W version (‘V’ – 56H)
PC→PCR340 | STX +‘ V ‘+ CR |
---|---|
PC←PCR340 | STX + ACK + Firmware number + Firmware version + CR |
Firmware number: ROM-Txxxx
Firmware version: Vx.xxrmVx.xx: Firmware version rm: Modification frequency
For Instance:
PC→PCR340 | 02 +‘ V ’+ 0D |
---|---|
PC←PCR340 | 02 + A + ROM-T2101+ V1.03R2 + 0D |
Get Product name (‘D’ > 56H)
PC→PCR340 | STX +‘ D ’+ CR |
---|---|
PC←PCR340 | STX + ACK + Product name + Keyboard language + CR |
Product: PCR-340X
Keyboard language: USA
For Instance:
PC→PCR340 | 02 + ‘ V ’ + 0D |
---|---|
PC←PCR340 | 02 + A + PCR-340X + ,+ USA + 0D |
Control mode ( ‘X’, 58H
PC→PCR340 | STX + X + CR |
---|---|
PC←PCR340 | STX + A + CR |
For Instance:
PC→PCR340 | 02 + X + 0D |
---|---|
PC←PCR340 | 02 + A + 0D |
*Show memory data (Y’ 59H)**
PC→PCR340 | STX + Y + CR |
---|---|
PC←PCR340 | STX + Register Table + CR |
For Instance:
PC→PCR340 | 02 + Y + 0D |
---|---|
PC←PCR340 | 02 + Register Table + 0D |
Register table
Functions of the latest version V1.03R2
Register Address | Function | Description |
---|---|---|
000h ~ 07Fh | Set Corresponding Card ID | 16 Characters |
100h ~ 1FFh | Set Output Characters | 16 Characters |
080h | Buzzer control | 000h: Off |
Other Parameter: On
088h| Mifare Card ID Sequence| FFh : Output Card ID in MSB first sequence.
00~FEh : Output Card ID in LSB first sequence.
089h| 125KHZ EM Card ID Sequence| FFh : Output Card ID in MSB first sequence.
00~FEh : Output Card ID in LSB first sequence.
090h~091h| MI fare standard MF1 ICS50 Card ID Filter| Register 090h: Start
Register 091h: Length
ID Filter Range: 1≥(Start+Length-1)≤8
092h~093h| MI fare 4K MF1 ICS70
Card ID Filter
| Register 092h: Start Register 093h: Length
ID Filter Range: 1≥(Start+Length-1)≤8
094h~095h| MI fare Ultralight MF0 ICS70
Card ID Filter
| Register 094h: Start Register 095h: Length
ID Filter Range: 1≥(Start+Length-1)≤14
096h~097h| MI fare Desire MF3 ICD40 Card ID Filter| Register 096h: Start
Register 097h: Length
ID Filter Range: 1≥(Start+Length-1)≤14
098h~099h| 125KHZ EM Card
Card ID Filter
| Register 098h: Start Register 099h: Length
ID Filter Range: 1≥(Start+Length-1)≤10
0A0h ~ 0AFh| Prefix up| 16 Characters
0B0h ~ 0BFh| Postfix up| 16 Characters
0C0h ~ 0CFh| On Remove up| 16 Characters
0D0h| Delimiter| 000h: CR
001h: LF
002h: TAB
003h: None
Other Parameter or 0xFF: CR + LF
0D1h| Baudrate| 004h: 2400
005h: 4800
006h: 9600
007h: 14400
Other Parameter or 0xFF: 19200
0D2h| Language (Keyboard type)| 000h: Japan
001h: France
002h: German 003h: UK
004h: Spain
Other Parameter: US
0D3h| USB Interface| 000h: CDC
Other Parameter: HID
0D4h| Display Card Type| 0FFh: NO Display
Other Parameter: Display
0D5h| Output by String Table| 0FFh: Card ID
Other Parameter: String
0D6h| Using code matching to right numeral part of keyboard| 000h: Enable
Other Parameter: Disable
0D7h| Output Card Format| 000h: Output Card Number in Dec.
Other Parameter: Output Card Number in Hex
0DAh| Tag Frequency Enable| Bit 0: 125KHz
Bit 1: 13.56MHz
Bit 2~7: None
(1: Enable, 0: Disable)
0DBh| Keyboard Output(USB HID Only)| 000h: Disable
Other Parameter: Enable
0E0h~0E1h| MI fare standard MF1 ICS50 Card ID Filter| Register 0E0h: Start
Register 0E1h: Length
ID Filter Range: 1≥(Start+Length-1)≤8
0E2h~0E3h| MI fare 4K MF1 ICS70 Card ID Filter| Register 0E2h: Start Register
0E3h: Length
ID Filter Range: 1≥(Start+Length-1)≤8
0E4h~0E5h| MI fare Ultralight MF0 ICS70 Card ID Filter| Register 0E4h: Start
Register 0E5h: Length
ID Filter Range: 1≥(Start+Length-1)≤14
0E6h~0E7h| MI fare Desire MF3 ICD40 Card ID Filter| Register 0E6h: Start
Register 0E7h: Length
ID Filter Range: 1≥(Start+Length-1)≤14
0E8h~0E9h| 125KHZ EM Card Card ID Filter| Register 0E8h: Start Register 0E9h:
Length
ID Filter Range: 1≥(Start+Length-1)≤10
LIMITED WARRANTY
Giga Tms warrants that the products sold pursuant to this Agreement will
perform in accordance with Giga-Tms’s published specifications. This warranty
shall be provided only for a period of one year from the date of the shipment
of the product from Giga-Tms (the “Warranty Period”). This warranty shall
apply only to the “Buyer” (the original purchaser, unless that entity resells
the product as authorized by Giga-Tms, in which event this warranty shall
apply only to the first re- purchaser).
During the Warranty Period, should this product fail to conform to Giga-Tms’s
specifications, Giga-Tms will, at its option, repair or replace this product
at no additional charge except as set forth below. Repair parts and
replacement products will be furnished on an exchange basis and will be either
reconditioned or new. All replaced parts and products become the property of
Giga-Tms. This limited warranty does not include service to repair damage to
the product resulting from accident, disaster, unreasonable use, misuse,
abuse, negligence, or modification of the product not authorized by Giga-Tms.
Giga-Tms reserves the right to examine the alleged defective goods to
determine whether the warranty is applicable.
Without limiting the generality of the foregoing, Giga-Tms specifically
disclaims any liability or warranty for goods resold in other than Giga-Tms’s
original packages, and for goods modified, altered, or treated without
authorization by Giga-Tms.
Service may be obtained by delivering the product during the warranty period
to Giga-Tms (8F No.
31 Lane 169, Kang Ning Street, Hsi Chih Dist New Taipei City, Taiwan). If this
product is delivered by mail or by an equivalent shipping carrier, the
customer agrees to insure the product or assume the risk of loss or damage in
transit, to prepay shipping charges to the warranty service location, and to
use the original shipping container or equivalent. Giga-Tms will return the
product, prepaid, via a three (3) day shipping service. A Return Material
Authorization (“RMA”) number must accompany all returns. Buyers may obtain an
RMA number by contacting with
sales@gigatms.com.tw
EACH BUYER UNDERSTANDS THAT THIS GIGA-TMS PRODUCT IS OFFERED ASIS. GIGA-TMS
MAKES NO OTHER WARRANTY, EXPRESS OR IMPLIED, AND GIGA- TMS DISCLAIMS ANY
WARRANTY OF ANY OTHER KIND, INCLUDING ANY WARRANTY OF MERCHANTABILITY OR
FITNESS FOR A PARTICULAR PURPOSE.
IF THIS PRODUCT DOES NOT CONFORM TO GIGA-TMS’S SPECIFICATIONS, THE SOLE REMEDY
SHALL BE REPAIR OR REPLACEMENT AS PROVIDED ABOVE. GIGA-TMS’S LIABILITY, IF
ANY, SHALL IN NO EVENT EXCEED THE TOTAL AMOUNT PAID TO GIGA-TMS UNDER THIS
AGREEMENT. IN NO EVENT WILL GIGA-TMS BE LIABLE TO THE BUYER FOR ANY DAMAGES,
INCLUDING ANY LOST PROFITS, LOST SAVINGS, OR OTHER INCIDENTAL OR CONSEQUENTIAL
DAMAGES ARISING OUT OF THE USE OF, OR INABILITY TO USE, SUCH PRODUCT, EVEN IF
GIGA-TMS HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES, OR FOR ANY CLAIM
BY ANY OTHER PARTY.
LIMITATION ON LIABILITY
EXCEPT AS PROVIDED IN THE SECTIONS RELATING TO GIGA-TMS’S LIMITED WARRANTY,
GIGA-TMS’S LIABILITY UNDER THIS AGREEMENT IS LIMITED TO THE CONTRACT PRICE OF
THIS PRODUCT.
GIGA-TMS MAKES NO OTHER WARRANTIES WITH RESPECT TO THE PRODUCT, EXPRESSED OR
IMPLIED, EXCEPT AS MAY BE STATED IN THIS AGREEMENT, AND GIGA-TMS DISCLAIMS ANY
IMPLIED WARRANTY, INCLUDING WITHOUT
LIMITATION ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR
PURPOSE.
GIGA-TMS SHALL NOT BE LIABLE FOR CONTINGENT, INCIDENTAL, OR CONSEQUENTIAL
DAMAGES TO PERSONS OR PROPERTY. GIGA-TMS FURTHER LIMITS ITS LIABILITY OF ANY
KIND WITH RESPECT TO THE PRODUCT, INCLUDING ANY NEGLIGENCE ON ITS PART, TO THE
CONTRACT PRICE FOR THE GOODS.
GIGA-TMS’S SOLE LIABILITY AND BUYER’S EXCLUSIVE REMEDIES ARE STATED IN THIS
SECTION AND IN THE SECTION RELATING TO GIGA-TMS’S LIMITED WARRANTY.
Waste Electrical and Electronic
Equipment (WEEE)
This symbol means that according to local laws and regulations your product
and/or its battery shall be disposed of separately from household waste. When
this product reaches its end of life, take it to a collection point designated
by local authorities. Proper recycling of your product will protect human
health and the environment.
Contact Us
GIGA-TMS INC.
ADDRESS:
8F, NO.31, Lane 169, Kang-Ning Street,
Hsi-Chih Dist, New Taipei City,
Taiwan
TEL: 886-2-26954214
FAX: 886-2-26954213
‘WEBSITE: WWW.gigatms.com.tw
EMAIL:
Sales & Product Inquiries –
promag@gigatms.com.tw
Product & Technical Support –
support@gigatms.com.tw
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>