GE current LED45ED17 Type B LED HID Hazardous Rated Lamp Installation Guide

October 26, 2023
GE current

GE current LED45ED17 Type B LED HID Hazardous Rated
logo

GE current LED45ED17 Type B LED HID Hazardous Rated Lamp

The Dreo ChefMaker: Create Deliciou...

The Dreo ChefMaker: Create Delicious Meals In Minutes!

GE current LED45ED17 Type B LED HID Hazardous Rated
productCONTACT A QUALIFIED ELECTRICIAN if you are not knowledgeable about luminaires and electrical systems. This LED Retrofit Kit Installation requires a familiarity with safety procedures, if not qualified, do not attempt installation.
WARNING
Risk of electrical shock or fire. Before installing this kit in a luminaire, make sure the luminaire matches the features and dimensions indicated in the photographs and that the input rating of the retrofit kit does not exceed the input rating of the luminaire.

  • DO NOT MAKE OR ALTER ANY OPEN HOLES IN AN ENCLOSURE OF WIRING OR ELECTRICAL COMPONENTS DURING KIT INSTALLATION. Do not expose wiring to edges of sheet metal or other sharp objects to prevent wiring damage or abrasion.
  • DO NOT disconnect the existing wires from lamp holder terminals in preparation for new connections. Cut the existing lamp holder terminal wires an appropriate distance from the connection point and use applicable connectors to attach the new wires.

THE RETROFIT KIT IS ACCEPTED AS A COMPONENT OF A LUMINAIRE WHERE THE SUITABILITY OF THE COMBINATION SHALL BE DETERMINED BY AUTHORITIES HAVING JURISDICTION. PRODUCT MUST BE INSTALLED BY A QUALIFIED ELECTRICIAN IN ACCORDANCE WITH THE APPLICABLE AND APPROPRI-ATE ELECTRICAL CODES. THE INSTALLATION GUIDE DOES NOT SUPERSEDE LOCAL OR NATIONAL REGULATIONS FOR ELECTRICAL INSTALLATIONS.
Input Rating
LED45ED17/YXX/HAZ 120-277V, 0.39 amps max, 45W LED35ED17/YXX/HAZ 120-277V, 0.33 amps max, 35W LED21ED17/YXX/HAZ 120-277V, 0.19 amps max, 21W
The Kit Includes:

  1. LED lamp
  2. Label for modified luminaire
  3.  Installation instructions
  4.  Wire connectors (2)
  5.  E26 to E39 socket adapter

Luminaire Fittings Reference Table

Luminaire Fitting Page
GE Lighting Filtr-Gard ® 2
Crouse-Hinds Champ ® VMV 3
Appleton Mercmaster ® III 4
Appleton Mercmaster ® II 5
GE Lighting Powr-Gard ® H9 Series 6
Hubell Killark ® VM Series 7
Holophane Petrolux P3M ® 9
Thomas & Betts Hazlux ® 3 Series 10
 Retrofitting GE Lighting Filtr-Gard®

Instructions for retrofitting UL Listed GE Lighting Filtr-Gard® Luminaire Fitting/Ballast Housing marked for use in Class I, Division 2, Groups A,B,C and D hazardous locations.

Fitting Filtr-Gard® Catalog#
Ballast Housing Series H2 ballast housings
Cover/Mounting Series H2000 mounts
Optical Assembly Series H2000 opticals

Lamp Base Adapter Usage

Ballast Housing| Adapter utilization
H20 SK, H205L, H2* 10M| Remove adapter from the lamp
All others| Use supplied adapter

Tools needed:

  1. Slotted screwdriver and adjustable wrench
  2. Wire cutter
  3. Wire stripper

NOTE:
The luminaire does not need to be removed from the mounting surface prior to modification
Instructions for GE Filtr-Gard® luminaire LED lamp and bypass ballast retrofit

Bypass Ballast Wiring

WARNING
Disconnect electrical power to the luminaire at the supply source.
CAUTION
Avoid burn risk — allow luminaire and lamp to cool before proceeding.GE
current LED45ED17 Type B LED HID Hazardous Rated 01

  1. Loosen the screw that holds the ballast housing and cover together.
  2. Hinge open the ballast cover and pull apart the two black plastic connectors to separate the quick disconnect function located between the cover and housing.
  3. Cut the black and white wires from the quick disconnect to the ballast circuitry leaving as much wire attached to the quick disconnect as possible. Be careful to leave the green ground wire connected.
  4. Cut the white (neutral) and color (hot) wires from the lamp holder in the center of the ballast housing, leaving as much wire attached to the lamp holder as possible.GE current LED45ED17 Type B LED HID Hazardous Rated 02
  5. Strip 3/8 inch from the snipped quick disconnect wires (from step 3) and the snipped lamp holder wires (from step 4). Using the included wire connectors, connect white to white and black to color (may be black).
  6. Place the ballast housing hinge pin over the cover hinge. Reconnect the mains quick disconnect device. Ensure no wires are pinched when tightening the cover screw.
    Filtr-Guard® is a registered trademark of General Electric Company

Lamp Installation Instructions

  1. If there is an optical guard, remove by rotating
    counter-clockwise, or removing retaining screws.

  2. Remove the optical by gently turning in a counter-clockwise direction.

  3. Remove old HID lamp and inspect socket for signs of wear and/or arcing. Contact original luminaire manufacturer for replacement parts if needed.

  4. If the old lamp has an E39 mogul base, install lamp with the supplied E26 to E39 adapter into the luminaire socket. If the luminaire has an E26 socket, remove the adapter from the lamp. Refer to the Lamp Base Adapter Usage Table.

  5.  Install the new LED lamp, ensuring the lamp is properly seated.GE current LED45ED17 Type B LED HID Hazardous Rated 03Install the new LED lamp, ensuring the lamp is properly seated.

  6. Reinstall the optical and guard to their original positions.

  7. Apply the new ratings label over the existing luminaire label. The new label specifies the replacement lamp and the revised luminaire application ratings.

  8. Restore power to the luminaire.

 Retrofitting Crouse-Hinds Champ

Instructions for retrofitting UL Listed Crouse-Hinds Champ® VMV Series HID Luminaire Fitting/Ballast Housing marked for use in Class I, Division 2, Groups A,B,C and D hazardous locations.

Fitting Champ® Catalog#
Ballast Housing VMVS &VMVM
Champ Cover (Mounting Module) APM2, APM3, HPM2, CM2, CM3, TWM2, TWM3, JM5,

PM5, QM25
Optical & Guard Components| G24, G24 S808, P21, RD70, RA70, G241, G243, G245, P241, R2, r3, R5, P23, PR2, PR3, PR5
Lamp Base Adapter Usage

Ballast Housing| Adapter utilization
VMV5050, VMVM070, VMVM100| Remove adapter from the lamp
All others| Use supplied adapter

Tools needed:

  1.  Slotted screwdriver and adjustable wrench
  2. Wire cutter
  3. Wire stripper

NOTE:
The luminaire does not need to be removed from the mounting surface prior to modification
WARNING
Disconnect electrical power to the luminaire at the supply source.
CAUTION
Avoid burn risk — allow luminaire and lamp to cool before proceeding.

Wiring

GE current LED45ED17 Type B LED HID Hazardous Rated 04

  1. Loosen the screw that holds the ballast housing and cover together.

  2. Hinge open the ballast cover.

  3. Remove wire connectors between incoming wires and ballast circuitry. Be careful to leave the green ground wire connected.GE current LED45ED17 Type B LED HID Hazardous Rated 05

  4. Remove wire connectors from the lamp holder wires.GE current LED45ED17 Type B LED HID Hazardous Rated 06

  5. Connect the lamp holder wires to incoming wires, using the included wire connectors. Connect white to white and black to black.

  6. Place the ballast housing hinge pin over the cover hinge. Close and secure the ballast housing and cover by tightening the screw. Ensure no wires are pinched when closing luminaire.
    Champ® is a registered trademark of Eaton’s Crouse-Hinds

  7. Unthread the optical assembly to remove guards, globes, or external reflectors.

  8. Remove old HID lamp and inspect socket for signs of wear and/or arcing. Contact original luminaire manufacturer for replacement parts if needed.

  9. If the old lamp has an E39 mogul base, install lamp with the supplied E26 to E39 adapter into the luminaire socket. If the luminaire has an E26 socket, remove the adapter from the lamp. Refer to the Lamp Base Adapter Usage Table.

  10. Install the new LED lamp, ensuring the lamp is properly seated.

  11. Thread optical assembly into ballast housing.

  12. Apply the new ratings label over the existing luminaire label. The new label specifies the replacement lamp and the revised luminaire application ratings.GE current LED45ED17 Type B LED HID Hazardous Rated 07

Restore power to the luminaire.

 Retrofitting Appleton Mercmaster®

Instructions for retrofitting UL Listed Appleton Mercmaster® III Series HID Luminaire Fitting/Ballast Housing marked for use in Class I, Division 2, Groups A,B,C and D hazardous locations.

Fitting Mercmaster® III Catalog#
Ballast Housing MLBG, MLBR,KPB & KPBR
Mounting Hood KPA75, KPA100, KPAF75, KPAF100, KPC75, KPC100, KPCH75, KPCH100,

KPS125, KPS150, KPST125, KPST150, KPWB75, KPWN100
Optical & Guard Components| CMR-4AN, CMR-45T, KR2-AN, KR2-ST, KRG2, KGU2, LPG-R, LPRF-CP, VPGL-*HR
Lamp Base Adapter Usage

Ballast Housing| Adapter utilization
MLBG & MLBR| Remove adapter from the lamp
KPB & KPBR| Use supplied adapter

Tools needed:

  1. Slotted screwdriver and adjustable wrench
  2.  Wire cutter
  3. Wire stripper

NOTE:
The luminaire does not need to be removed from the mounting surface prior to modification
WARNING
Disconnect electrical power to the luminaire at the supply source.
CAUTION
Avoid burn risk — allow luminaire and lamp to cool before proceeding.
WiringGE current LED45ED17 Type B LED HID Hazardous Rated
08

  1. Loosen the nut that holds the ballast housing and cover together.

  2. Hinge open the ballast cover.GE current LED45ED17 Type B LED HID Hazardous Rated 09

  3. Remove wire connectors /wire nuts between incoming wires and ballast circuitry. Disconnect the incoming wire to the fuse if the device has one. Discard all the fuses if applicable. Be careful to leave the green ground wire connected.

  4. Remove wire connectors from the lamp holder wires, which may be bundled together with other wires. Carefully trace all wires from the lamp holder. Discard any additional white wires.GE current LED45ED17 Type B LED HID Hazardous Rated 10

  5. Connect the lamp holder wires to incoming wires, using the included wire connectors. Make sure the supply neutral is connected to the white wire and the supply hot is connected to the lamp holder black wire.

  6.  Place the ballast housing hinge pin over the cover hinge. Close and secure the ballast housing and cover by tightening the screw.
    Mercmaster® is a registered trademark of Appleton Grp.

  7. Loosen screws and unthread the optical assembly to remove guards, globes, or external reflectors.

  8. Remove old HID lamp and inspect socket for signs of wear and/or arcing. Contact original luminaire manufacturer for replacement parts if needed.

  9. If the old lamp has an E39 mogul base, install lamp with the supplied E26 to E39 adapter into the luminaire socket. If the luminaire has an E26 socket, remove the adapter from the lamp. Refer to the Lamp Base Adapter Usage Table.

  10. Install the new LED lamp, ensuring the lamp is properly seated.

  11. Thread optical assembly into ballast housing.

  12. Apply the new ratings label over the existing luminaire label. The new label specifies the replacement lamp and the revised luminaire application ratings.GE current LED45ED17 Type B LED HID Hazardous Rated 11

Restore power to the luminaire.

 Retrofitting Appleton Mercmaster®

Instructions for retrofitting UL Listed Appleton Mercmaster® II Series HID Luminaire Fitting/Ballast Housing marked for use in Class I, Division 2, Groups A,B,C and D hazardous locations.

Fitting Mercmaster® II Catalog#
Ballast Housing LPB, 4 ¾” height housing only
Mounting Hood LPA-75, LPA-100, LPC-75, LPC-100, LPWB-75, LPWB-100, LPS-125,

LPSD-150
Optical & Guard Components| LPRF-*, VPGL-***, KGU2, KR2-
Lamp Base Adapter Usage**

Ballast Housing| Adapter utilization
LPB, 4 ¾”height housing only| Use supplied adapter

Tools needed:

  1. Slotted screwdriver and adjustable wrench
  2. Wire cutter
  3. Wire stripper

NOTE: The luminaire does not need to be removed from the mounting surface prior to modification
WARNING
Disconnect electrical power to the luminaire at the supply source.
CAUTION
Avoid burn risk — allow luminaire and lamp to cool before proceeding.
WiringGE current LED45ED17 Type B LED HID Hazardous Rated
12

  1. Loosen the nut that holds the ballast housing and cover together.

  2. Hinge open the ballast cover.GE current LED45ED17 Type B LED HID Hazardous Rated 13

  3. Remove wire connectors /wire nuts between incoming wires and ballast circuitry. Be careful to leave the green ground wire connected.

  4. Locate the wire tie and cut it, separate the wiring from the bundle. Remove wire connectors from the lamp holder wires. Discard any additional white wires. The lamp holder wires are black and white and come from under the ballast housing. The ballast is under the bracket in the center of the housing.GE current LED45ED17 Type B LED HID Hazardous Rated 14

  5. Connect the lamp holder wires to incoming wires, using the included wire connectors. Make sure the supply neutral is connected to the white wire and the supply hot is connected to the lamp holder black wire.

  6.  Place the ballast housing hinge pin over the cover hinge. Close and secure the ballast housing and cover by tightening the nut.
    Mercmaster® is a registered trademark of Appleton Grp.

  7. Loosen screws and unthread the optical assembly to remove guards, globes, or external reflectors.

  8. Remove old HID lamp and inspect socket for signs of wear and/or arcing. Contact original luminaire manufacturer for replacement parts if needed.

  9. If the old lamp has an E39 mogul base, install lamp with the supplied E26 to E39 adapter into the luminaire socket. If the luminaire has an E26 socket, remove the adapter from the lamp. Refer to the Lamp Base Adapter Usage Table.

  10. Install the new LED lamp, ensuring the lamp is properly seated.

  11. Thread optical assembly into ballast housing.

  12. Apply the new ratings label over the existing luminaire label. The new label specifies the replacement lamp and the revised luminaire application ratings.GE current LED45ED17 Type B LED HID Hazardous Rated 15

Restore power to the luminaire.

Retrofitting GE Lighting Powr-Gard®

Instructions for retrofitting UL Listed GE Lighting Powr-Gard® Luminaire Fitting/Ballast Housing marked for use in Class I, Division 2, Groups A,B,C and D hazardous locations.

Fitting Powr-Gard® Catalog#
Ballast Housing Series H9 ballast housings
Cover/Mounting Series H9 mounts
Optical & Guard Components All Series H9 opticals and guards

Lamp Base Adapter Usage

Ballast Housing| Adapter utilization
H9| Use supplied adapter

Tools needed:

  1. Slotted screwdriver
  2. Small flat blade screwdriver
  3.  Wire cutter
  4. Wire stripper

NOTE:
The luminaire does not need to be removed from the mounting surface prior to modification
Instructions for GE Powr-Gard® luminaire LED lamp and bypass ballast retrofit

Bypass Ballast Wiring

WARNING
Disconnect electrical power to the luminaire at the supply source.
CAUTION
Avoid burn risk — allow luminaire and lamp to cool before proceeding.GE
current LED45ED17 Type B LED HID Hazardous Rated 16

  1. Loosen the setscrew with a small flat blade screwdriver and remove the optical assembly by rotating counterclockwise.

  2. Remove old HID lamp and inspect socket for signs of wear and/or arcing. Contact original luminaire manufacturer for replacement parts if needed.GE current LED45ED17 Type B LED HID Hazardous Rated 17

  3. Remove ballast cover plate. Locate wires going to lamp socket, and disconnect from the ballast. Cut and remove terminations, keeping lampholder wires as long as possible.
    GE current LED45ED17 Type B LED HID Hazardous Rated 18

  4. Disconnect the AC input wires from the ballast and cut and remove the terminations, keeping the wires as long as possible.

  5. Strip 3/8 inch from the snipped lamp holder wires (from step 3) and the snipped AC input wires (from step 4). Using the included wire connectors, connect the AC to the lamp holder wires as follows: If the lamp holder wires are white and black, then connect white to white and black to black. If the lamp holder wires are black and blue, connect AC white to lamp holder blue, connect AC black to lamp holder black. If the lamp holder wires are white and blue, connect AC white to lamp holder white and AC black to lampholder blue.

  6. Reinstall the ballast cover plate and lamp holder. Ensure no wires are pinched when tightening the cover screws.

  7. If the old lamp has an E39 mogul base, install lamp with the supplied E26 to E39 adapter into the luminaire socket. If the luminaire has an E26 socket, remove the adapter from the lamp. Refer to the Lamp Base Adapter Usage Table.

  8. Install the new LED lamp, ensuring the lamp is properly seated.

  9. Reinstall the optical (and guard) by rotating the optical assembly clockwise while supporting the optical.

  10. Retighten the optical lock setscrew with a small flat blade screwdriver.

  11. Apply the new ratings label over the existing luminaire label. The new label specifies the replacement lamp and the revised luminaire application ratings.

Powr-Gard® is a registered trademark of General Electric Company.GE current
LED45ED17 Type B LED HID Hazardous Rated 19Restore power to the luminaire.

Retrofitting Hubell Killark®

Instructions for retrofitting UL Listed Hubell Killark® VM Series HID Luminaire Fitting/Ballast Housing marked for use in Class I, Division 2, Groups A,B,C and D hazardous locations.

Fitting Killark® Catalog#
Ballast Housing VM1, VM2, VM3, VM4, VM5, VMLO, VMMO

Cover
(Mounting Module)| VMA2B, VMA3B, VMB2B, VMB3B, VMC2B, VMC3B, VMD4B, VMD5B, VMF2B, VMF3B, VMS4B, VMS5B, VMX2B, VMX3B, VMX6B, VMX7B, VMX8B, VMX9B
Optical & Guard Components| VMG17, VMG25, VMR171, VMR175, VMR251, VMR253, VMR255, VZRG1550, VZRG252, VMAG17, VMAG25S, VMERG, VMRWG, VMRWG8, VMRERG, VZRG2550, VMEP40, VMER40, VMPSD40, VMPA40
Lamp Base Adapter Usage

Ballast Housing| Adapter utilization
VM1, VM2,| Remove adapter from the lamp
VM3, VM4, VM5, VMLO, VMMO| Use supplied adapter

Tools needed:

  1. Slotted screwdriver and adjustable wrench
  2. Wire cutter
  3. Wire stripper

NOTE:
The luminaire does not need to be removed from the mounting surface prior to modification
WARNING
Disconnect electrical power to the luminaire at the supply source.
CAUTION
Avoid burn risk — allow luminaire and lamp to cool before proceeding.
WiringGE current LED45ED17 Type B LED HID Hazardous Rated
20

  1. Loosen the screw that holds the ballast housing and cover together.
  2.  Hinge open the ballast cover.GE current LED45ED17 Type B LED HID Hazardous Rated 21
  3. Remove wire connectors between incoming wires and ballast circuitry. Be careful to leave the green ground wire connected.
  4. Remove wire connectors from the lamp holder wires.GE current LED45ED17 Type B LED HID Hazardous Rated 22
  5. Connect the lamp holder wires to incoming wires, using the included wire connectors. Connect white to white and black to black.
  6.  Place the ballast housing hinge pin over the cover hinge. Close and secure the ballast housing and cover by tightening the screw. Ensure no wires are pinched when closing luminaire.
  7. Unthread the optical assembly to remove guards, globes, or external reflectors.
  8. Remove old HID lamp and inspect socket for signs of wear and/or arcing. Contact original luminaire manufacturer for replacement parts if needed.
  9. If the old lamp has an E39 mogul base, install lamp with the supplied E26 to E39 adapter into the luminaire socket. If the luminaire has an E26 socket, remove the adapter from the lamp. Refer to the Lamp Base Adapter Usage Table.
  10. Install the new LED lamp, ensuring the lamp is properly seated.
  11. Thread optical assembly into ballast housing.
  12. Apply the new ratings label over the existing luminaire label. The new label specifies the replacement lamp and the revised luminaire application ratings.GE current LED45ED17 Type B LED HID Hazardous Rated 23

ًRestore power to the luminaire.

 Retrofitting Holophane Petrolux P3M®

Instructions for retrofitting UL Listed Holophane Petrolux P3M® Series HID Luminaire Fitting/Ballast Housing marked for use in Class I, Division 2, Groups A,B,C and D hazardous locations.

Fitting Holophane P3M® Refractor
Ballast Housing HID Source, 50-175 watt HPS or MH
Mounting Hood ST, WL, PD, CE, UN
Optical & Guard Components 541, 545, GD

Lamp Base Adapter Usage

Ballast Housing| Adapter utilization
MH Source (E26 socket)| Remove adapter from the lamp
MH Source (E39 socket) HPS Source (E39 socket)| Use supplied adapter

Tools needed:

  1.  Slotted screwdriver and adjustable wrench
  2. Wire cutter
  3. Wire stripper

NOTE:
The luminaire does not need to be removed from the mounting surface prior to modification
WARNING
Disconnect electrical power to the luminaire at the supply source.
CAUTION
Avoid burn risk — allow luminaire and lamp to cool before proceeding.
WiringGE current LED45ED17 Type B LED HID Hazardous Rated
24

  1. Loosen the bolt that holds the ballast housing and cover together.
  2. Hinge open the ballast cover.GE current LED45ED17 Type B LED HID Hazardous Rated 25
  3. Remove wire connectors /wire nuts between incoming wires and ballast circuitry. Disconnect the incoming wire to the fuse if the device has one. Discard all the fuses if applicable. Be careful to leave the green ground wire connected.
  4. Remove wire connectors from the lamp holder wires, which may be bundled together with other wires. Carefully trace all wires from the lamp holder. Disconnect any additional wires from the lamp holder white and black leads
  5. GE current LED45ED17 Type B LED HID Hazardous Rated 26Connect the lamp holder wires to incoming wires, using the included wire connectors. Make sure the supply neutral is connected to the white wire and the supply hot is connected to the lamp holder black wire.
  6. Place the ballast housing hinge pin over the cover hinge. Close and secure the ballast housing and cover by tightening the screw.
  7. Remove optical assembly by turning black tabs around optical counterclockwise.
  8. Remove old HID lamp and inspect socket for signs of wear and/or arcing. Contact original luminaire manufacturer for replacement parts if needed.
  9. If the old lamp has an E39 mogul base, install lamp with the supplied E26 to E39 adapter into the luminaire socket. If the luminaire has an E26 socket, remove the adapter from the lamp. Refer to the Lamp Base Adapter Usage Table.
  10.  Install the new LED lamp, ensuring the lamp is properly seated.
  11. Thread optical assembly into ballast housing.
  12. Apply the new ratings label over the existing luminaire label. The new label specifies the replacement lamp and the revised luminaire application ratings.GE current LED45ED17 Type B LED HID Hazardous Rated 27

Restore power to the luminaire.

 Retrofitting Thomas & Betts Hazlux®

Instructions for retrofitting UL Listed Thomas & Betts Hazlux® 3 Series HID Luminaire Fitting/Ballast Housing marked for use in Class I, Division 2, Groups A,B,C and D hazardous locations.

Fitting Thomas & Betts Hazlux® Catalog#
Ballast Housing DS, DH
Mounting Hood VA2,VA3,VB2,VB3,VC2,VC3,VF2,VF3, VL4,VL5,VP2,VP3,VS4,VS5
Optical & Guard VGT22,VGT22TS,VGT31S, VGT31STS,
Components VRF22C5,VRF31C5,VGL31R1,VGL31R3, VGL31R5,VRB31CBVGR48,VGR64,VGU22,
VGU22P,VGU31R,VGU31RP,VRA22P,
VR22P,VR31P,VRA31P

Lamp Base Adapter Usage

Ballast Housing| Adapter utilization
MH Source (E26 socket)| Remove adapter from the lamp
MH Source (E39 socket) HPS Source (E39 socket)| Use supplied adapter

Tools needed:

  1.  Slotted screwdriver and adjustable wrench
  2. Wire cutter
  3.  Wire stripper

NOTE: The luminaire does not need to be removed from the mounting surface prior to modification
WARNING
Disconnect electrical power to the luminaire at the supply source.
CAUTION
Avoid burn risk — allow luminaire and lamp to cool before proceeding.
WiringGE current LED45ED17 Type B LED HID Hazardous Rated
28

  1. Loosen the bolt that holds the ballast housing and cover together.
  2.  Hinge open the ballast cover.GE current LED45ED17 Type B LED HID Hazardous Rated 29
  3. Remove wire connectors /wire nuts between incoming wires and ballast circuitry. Disconnect the incoming wire to the fuse if the device has one. Discard all the fuses if applicable. Be careful to leave the green ground wire connected.
  4. Remove wire connectors from the lamp holder wires, which may be bundled together with other wires. Carefully trace all wires from the lamp holder. Disconnect any additional wires from the lamp holder white and black leads.GE current LED45ED17 Type B LED HID Hazardous Rated 30
  5. Connect the lamp holder wires to incoming wires, using the included wire connectors. Make sure the supply neutral is connected to the white wire and the supply hot is connected to the lamp holder black wire.
  6. Place the ballast housing hinge pin over the cover hinge. Close and secure the ballast housing and cover by tightening the screw.
  7. Loosen screws and unthread the optical assembly to remove guards, globes, or external reflectors.
  8. Remove old HID lamp and inspect socket for signs of wear and/or arcing. Contact original luminaire manufacturer for replacement parts if needed.
  9. If the old lamp has an E39 mogul base, install lamp with the supplied E26 to E39 adapter into the luminaire socket. If the luminaire has an E26 socket, remove the adapter from the lamp. Refer to the Lamp Base Adapter Usage Table.
  10.  Install the new LED lamp, ensuring the lamp is properly seated.
  11. Thread optical assembly into ballast housing.
  12. Apply the new ratings label over the existing luminaire label. The new label specifies the replacement lamp and the revised luminaire application ratings.GE current LED45ED17 Type B LED HID Hazardous Rated 31

Restore power to the fixture.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

GE current User Manuals

Related Manuals