ecowitt WH0290 Wireless PM2.5 Air Quality Monitor User Manual

June 14, 2024
ECOWITT

ecowitt WH0290 Wireless PM2.5 Air Quality Monitor

Specifications

  • Model: WH0290
  • Wireless Air Quality Monitor with Indoor Temperature and
    Humidity

Product Usage Instructions

Introduction

Thank you for purchasing the WH0290 Wireless Air Quality Monitor with Indoor Temperature and Humidity. To ensure the best product performance, please read this manual and retain it for future reference.

For the latest manual and additional help, please contact us at
support@ecowitt.com or
support.eu@ecowitt.net
(EU/UK).

Get Started
Note: Power up sequence can be performed in the order shown in this section (insert batteries in the Air Quality Monitor first, then Sensor(transmitter)).

Attention:

  • Do not mix old and new batteries
  • Do not mix Alkaline, Standard, Lithium or Rechargeable batteries
  • Ensure batteries are installed correctly with regard to polarity +/-
  • Please fully charge the included sensor batteries overnight when first use.
  • If PM2.5 reading is permanently 0 or with a value extremely low after some period of use, it is very likely that the sensor tunnel was occupied by a spider net. You may use a can of compressed air to blow into the inlet of the sensor (open the housing) to see if this can help fix the problem.

Parts List

  1. One Air Quality Monitor (Receiver)
  2. One Air Quality Sensor (Wireless PM2.5 Sensor)
  3. One USB Cable
  4. One User Manual
  5. Two LSD (low self-discharge) Ni-MH Rechargeable Batteries

Air Quality Sensor Set Up

  1. Remove the battery door on the base of the air quality sensor.
  2. Insert two AA batteries.
  3. After inserting the battery, the remote sensor should be ready for use.

Display Console Set Up

  1. Move the remote about 2 to 3m away from the display console (if the sensor is too close, it may not be received by the display console).
  2. Remove the battery door on the back of the display console.
  3. Insert one AA (alkaline, lithium, or rechargeable) battery in the back of the display console.
  4. All of the LCD segments will light up for a few seconds to verify all segments are operating properly.
  5. Replace the battery door and fold out the desk stand to place the console in the upright position.
  6. The console will instantly display indoor temperature and humidity. The PM 2.5 value will update on the display within a few minutes.
  7. While in the search mode, the reception search icon will flash.
  8. If the remote does not update, please contact customer support.

Wireless Sensor Installation
Instructions for wireless sensor installation are not included in the provided text extract. Please refer to the user manual for detailed instructions.

Console Operation
Instructions for console operation are not included in the provided text extract. Please refer to the user manual for detailed instructions.

FAQ

Frequently asked questions about the WH0290 Wireless Air Quality Monitor with Indoor Temperature and Humidity:

Q: How do I download the latest manual and additional help?
A: To download the latest manual and additional help, please contact us at support@ecowitt.com or support.eu@ecowitt.net (EU/UK).

Q: What should I do if the PM2.5 reading is permanently 0 or extremely low?
A: It is likely that the sensor tunnel was occupied by a spider net. You may use a can of compressed air to blow into the inlet of the sensor (open the housing) to see if this can help fix the problem.

Q: How should I install the wireless sensor?
A: Instructions for wireless sensor installation are not included in the provided text extract. Please refer to the user manual for detailed instructions.

Q: How do I operate the console?
A: Instructions for console operation are not included in the provided text extract. Please refer to the user manual for detailed instructions.

Wireless Air Quality Monitor with
Indoor Temperature and Humidity
Model: WH0290

Introduction

Thanks for your purchasing of the WH0290
Wireless Air Quality Monitor with Indoor
Temperature and Humidity. To ensure the best product performance, please read this manual and retain it for future reference.

Help
Our product is continuously changing and improving, particularly online services and associated applications. To download the latest manual and additional help, please contact us at support@ecowitt.com or support.eu@ecowitt.net (EU/UK).

Get Started

Note: Power up sequence can be performed in the order shown in this section (insert batteries in the Air Quality Monitor first, then Sensor(transmitter).

Attention:

  • Do not mix old and new batteries
  • Do not mix Alkaline, Standard, Lithium or Rechargeable batteries
  • Ensure batteries are installed correctly with regard to polarity +/-
  • Please fully charge the included sensor batteries overnight when first use.
  • If PM2.5 reading is permanently 0 or with a value extremely low after some period of use, it is very likely that the sensor tunnel was occupied by a spider net. You may use a can of compressed air to blow into the inlet of the sensor( open the housing) to see if this can help fixing the problem.

Parts List

  1. One Air Quality Monitor (Receiver)
  2. One Air Quality Sensor(Wireless PM2.5 Sensor)
  3. One USB Cable
  4. One User Manual
  5. Two LSD( low self discharge) Ni-MH Rechargeable Batteries

Air Quality Sensor Set Up

  1. Remove the battery door on the base of the air quality sensor as shown in Figure 1

  2. Solar panel

  3. Battery Compartment Cover

  4. Red LED Indicator (RF transmission)

  5. Blue LED Indicator (charging status)

  6. USB Port

  7. Battery Compartment

  8. Insert two AA battery.

  9. After inserting the battery, the remote sensor LED indicator will light for 4 seconds, and then flash once per 10 minutes thereafter.
    Each time it flashes, the sensor is transmitting data.

  10. Connect the USB cable to a standard USB power adapter and charge battery until blue LED is turned off, indicating batteries are fully charged.

  11. When no sufficient solar radiation is possible,a fully charged set battery can last for about 20 days( about 500hours), and battery status monitor on display will reflect the battery power status. When battery is empty, please charge sensor again.

  12. After the batteries are fully charged, remove the USB cable and close the battery door.

Display Console Set Up

  1. Move the remote about 2 to 3m away from the display console (if the sensor is too close, it may not be received by the display console).

  2. Remove the battery door on the back of the display, as shown in Figure 2. Insert one AA (alkaline, lithium or rechargeable) battery in the back of the display console.

  3. Integrated Hanging Hole

  4. Tabletop Stand

  5. °C/°F Button

  6. MAX Button

  7. Battery Compartment

  8. Battery Compartment Cover
    All of the LCD segments will light up for a few seconds to verify all segments are operating properly.

  9. Replace the battery door, and fold out the desk stand and place the console in the upright position.
    The console will instantly display indoor temperature and humidity. The PM 2.5 value will update on the display within a few minutes.
    While in the search mode, the reception search icon flash.
    If the remote does not update, please contact our Customer Service for support.

Display Console Layout

ecowitt-WH0290-Wireless-PM2-5-Air-Quality-Monitor-FIG-
\(4\)

  1. Current PM2.5 Concentration
  2. Air Quality Level
  3. Current AQI
  4. Indoor Temperature
  5. Indoor Humidity
  6. 1h Max AQI
  7. 1h Max PM2.5 Concentration
  8. Outdoor Reception Icon

Wireless Sensor Installation

Outdoor Installation
Use four screws to fix the base of the outdoor sensor on a flat surface.

ecowitt-WH0290-Wireless-PM2-5-Air-Quality-Monitor-FIG-
\(5\)

Console Operation

Note: The console has two buttons for easy operation【: °C/°F】button (on the left), and【MAX】 button (on the right).

  1. °C/°F
    Short press【°C/°F】button: switch between display of temperature unit: °C/°F
    Press and hold the 【° C/ ° F 】button for 2 seconds: switch between display of the 24H average value of the PM2.5 concentration and AQI.

  2. MAX
    Short press the【MAX】button: switch between display of the 1h MAX / 24h MAX / MAX(since last reset) value of the PM2.5 concentration and AQI.
    Press and hold the【MAX】button for 2s to clear all the 1h MAX / 24h MAX / MAX(since last reset) value.

Sensor Resynchronization

When the remote sensor lost reception, holding the °C/°F and MAX button for 5s, will register new outdoor for 12 minutes.
While in the search mode, the reception search icon flash.
You can also re-sync the two units by removing all the batteries and then wait for several minutes. Then install the batteries again to register faster.

Best Practices for Wireless Communication

Note: To insure proper communication, place the remote sensor on a flat surface. Do not lean or upside down it to avoid any damage.
Keep the console several feet away from computer monitors and TVs.

  1. Indoor temperature and humidity
  2. Every 60 second the unit will measure indoor temperature and humidity.
  3. Display current / 24H average PM 2.5 concentration and AQI.
  4. Display 1h MAX / 24h MAX / MAX (since last reset) PM 2.5 concentration and AQI.
  5. Air quality level indicator color bar based on AQI.
  6. IPx4 rainproof sensor, can be used both indoor and outdoor.
  7. The wireless signal strength displays reception quality. If no signal is lost, the signal strength indicator will display 5 bars.
    If the signal is lost once, four bars will be displayed.

Appendix

About the Air Quality Levels

AQI

| Air Pollution Level| PM2.5

Concentration ug/m3

|

Health Implications

| Cautionary Statement (for PM2.5)
---|---|---|---|---

0 – 50

|

Good

|

0.0-12.0

| Air quality is considered satisfactory, and air pollution poses little or

no risk

|

None

51 -100

|

Moderate

|

12.1-35.4

| Air quality is acceptable; however, for some pollutants there may be a moderate health concern for a very small number of people who

are unusually sensitive to air pollution.

|

Active children and adults, and people with respiratory disease, such as asthma, should limit prolonged outdoor exertion.

101-150

|

Poor

|

35.5-55.4

| Members of sensitive groups may experience health effects. The general public is not likely to be affected.| Active children and adults, and people with respiratory disease, such as asthma, should limit prolonged outdoor exertion.

151-200

|

Unhealthy

|

55.5-150.4

| Everyone may begin to experience health effects; members of sensitive groups may experience more serious health effects| Active children and adults, and people with respiratory disease, such as asthma, should avoid prolonged outdoor exertion; everyone else, especially children,

should limit prolonged outdoor exertion

201-300

|

Severe

|

150.5-250.4

| Health warnings of emergency conditions. The entire population is more likely to be affected.| Active children and adults, and people with respiratory disease, such as asthma, should avoid all outdoor exertion; everyone else, especially children, should limit outdoor

exertion.

300+

|

Hazardous

|

250.5+

| Health alert: everyone may experience more serious health effects|

Everyone should avoid all outdoor exertion

Specifications

Wireless Specifications

  • Line of sight wireless transmission (in open air): 300feet(100meters)
  • Frequency: 433/915/868 MHz (optional)
  • Update Rate: 10 minutes

Measurement Specifications
The following table provides specifications for the measured parameters.

Measurement Range Accuracy Resolution

Indoor

temperature

| 14 to 140 °F

(-10 to 60°C)

| ± 1 °F

(±1°C)

| 0.1 °F

(±0.5°C)

Indoor Humidity| 10 to 99 %| Accuracy +/- 3% RH (@25°C. , 30%RH to 80%RH)

Accuracy +/- 5% RH (@25°C. , 1%RH to29%RH;80%RH to

99%RH)

| 1%
PM 2.5| 0~999ug/m3| 0~100ug/m3       ±10ug/m3

100~500ug/m3 ±10%

| 1ug/m3

Power Consumption
  • Base station (display console) : 1 x AA
    Alkaline or Lithium batteries (not included)

  • Remote sensor : 2 x AA 1.2V LSD type
    NI-MH batteries (included)
    Solar panel for backup power

Note:

  1. Battery type for charging: 2 x AA 1.2V NI-MH batteries(battery life: 3 weeks)
  2. It’s recommended to recharge the outdoor sensor every two weeks.
  3. Charge time: 3h (The blue LED indicator will light when in charge and be off when full charged)
  4. Charge Method: USB charge(USB Cable included)

Warranty Information

We disclaim any responsibility for any technical error or printing error, or their consequences.
All trademarks and patents are recognized.
We provide a 1-year limited warranty on this product against manufacturing defects in materials and workmanship.
This limited warranty begins on the original date of purchase, is valid only on products purchased and only to the original purchaser of this product.
To receive warranty service, the purchaser must contact us for problem determination and service procedures.
This warranty covers only actual defects within the product itself, and does not cover the cost of installation or removal from a fixed installation, normal set-up or adjustments, claims based on misrepresentation by the seller or performance variations resulting from installation-related circumstances.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals