KRAMER RC-2C Wall Plate IR Controller User Manual
- June 14, 2024
- Kramer
Table of Contents
Kramer Electronics, Ltd.
USER MANUAL
Models:
RC-2C, Wall Plate / RS-232 / IR Controller
RC-2, Wall Plate / RS-232 Controller
Introduction
Welcome to Kramer Electronics! Since 1981, Kramer Electronics has been
providing a world of unique, creative, and affordable solutions to the vast
range of problems that confront the video, audio, presentation, and
broadcasting professional on a daily basis. In recent years, we have
redesigned and upgraded most of our line, making the best even better! Our
1,000-plus different models now appear in 11 groups 1 that are clearly defined
by function.
Congratulations on purchasing your Kramer RC-2C Wall Plate / RS-232/ IR
Controller and/or the RC-2 Wall Plate / RS-232 Controller which are available
in European (80mm and 86mm versions) and American versions.
The package includes the following items:
- RC-2C Wall Plate / RS-232/ IR Controller or RC-2 Wall Plate / RS-232 Controller
- Power supply (12V DC input)
- This user manual 2
Getting Started
We recommend that you:
- Unpack the equipment carefully and save the original box and packaging materials for possible future shipment
- Review the contents of this user manual
- Use Kramer high performance high resolution cables 3
-
GROUP 1: Distribution Amplifiers; GROUP 2: Switchers and Matrix Switchers; GROUP 3: Control Systems; GROUP 4:
Format/Standards Converters; GROUP 5: Range Extenders and Repeaters; GROUP 6: Specialty AV Products; GROUP 7:
Scan Converters and Scalers; GROUP 8: Cables and Connectors; GROUP 9: Room Connectivity; GROUP 10: Accessories and Rack Adapters; GROUP 11: Sierra Products -
Download up-to-date Kramer user manuals from the Internet at: http://www.kramerelectronics.com
-
The complete list of Kramer cables is on our Web site at http://www.kramerelectronics.com
Overview
The RC-2C/RC-2 is a 1 Gang 2-button controller 1 with an RS-232 port, an IR
OUT port (for the RC-2C only) and two backlit and label capable buttons. It
sends an RS-232 command—with the push of a button—to a device (such as a
projector, display or switcher) via serial control protocols.
Each button can be assigned with a trigger containing up to four actions for
RC-2 and up to eight actions for RC-2C.
To achieve the best performance avoid interference from neighboring electrical
appliances and position your Kramer RC-2C/RC-2 away from moisture, excessive
sunlight and dust.
| Caution: No operator serviceable parts inside unit
Caution: Use only the Kramer Electronics input power wall adapter that is
provided with the unit
Caution: Disconnect power and unplug unit from wall before installing or
removing the device or servicing unit
---|---
- Available as a 1 Gang wall plate for the USA or a 1 Gang wall plate for Europe (in two sizes: 8.6cm and 8cm)
Your RC-2C/RC-2
The RC-2C/RC-2 is available in three versions 1 (see Figure 1 ): one for Belgium and Germany, one for England and Europe (except Belgium and Germany), and one for the United States:
Figure 2 and Table 1 define the RC-2C rear panel: Your RC-2C/RC-2
Table 1: Features and Functions of the RC-2C
# | Feature | Function |
---|---|---|
1 | RC-2C Front Panel | Front panel, including two control buttons |
2 | PROGRAM ENABLE Switch | For technical support use only |
3 | GND PIN | Connect to an IR emitter cable |
IR OUT PIN
4| +12V PIN| Connects (-) to the Ground
GND PIN| Connects (+) to the connector for powering the unit
5| RS-232 Terminal Block Connector| Connect to the RS-232 connector on the
A/V equipment or a PC or other Serial Controller, see Section 4.1
Figure 3 and Table 2 define the RC-2 rear panel:
Table 2: Features and Functions of the RC-2
# | Feature | Function |
---|---|---|
1 | RC-2 Front Panel | Front panel, including two control buttons |
2 | PROGRAM ENABLE Switch | For technical support use only |
3 | GND PIN | Connects (-) to the Ground |
+12V PIN | Connects (+) to the connector for powering the unit | |
4 | RS-232 Terminal Block Connector | Connect to the RS-232 connector on the |
A/V equipment or a PC or other Serial Controller, see Section 4.1
4.1 The RS-232 PINOUT
The RS-232 9-pin D-sub port PINOUT is defined in Figure 4 and Table 3:
Table 3: RS-232 PINOUT Connection
Connect this PIN on the Terminal Block Connector:| To this PIN on
the 9-pin D-sub Connector
---|---
Tx| PIN 2
Rx| PIN 3
GND| PIN 5
4.2 Connecting the IR-OUT (for the RC-2C Only)
Figure 5 shows how to connect the IR emitter 1 . The white striped side
connects to IR OUT, the black side connects to the Ground, and the LED Emitter
Shell is affixed to the IR sensor window with the adhesive layer.
Installing the Configuration Software
Download the K-Config configuration software from our Web site and install it (refer to the K-Config guide 1 ).
Configuring the RC-2C/RC-2 Buttons
To configure the RC-2C/RC-2 buttons, refer to the K-Config guide.
Before you configure the RC-2C/RC-2 buttons:
- Connect the power to the RC-2C/RC-2 and connect the RS-232 terminal block connector on the RC-2C/RC-2 unit to the 9-pin D-sub COM port on your PC as defined in Section 4.1.
- Open the K-Config program. The main K-Config window appears.
- Follow the instructions in the K-Config guide to configure the RC-2C/RC-2 buttons. 1
Technical Specifications
Table 4 defines the technical specifications:
2
Table 4: Technical Specifications
of the RC-2C/RC-2 Wall Plate / RS-232 Controller
PORTS:| 1 RS-232 on a terminal block connector IR OUT on a terminal
block connector (for RC-2C only)
---|---
POWER SOURCE:| 12V DC/500mA adapter, 40mA
DIMENSIONS:| For the USA :
6.9cm x 1.6cm x 11.4cm (2.72″ x 0.63″ x 4.49″, W, D, H)
For Europe :
8.6cm x 1.6cm x 8.6cm (3.39″ x 0.63″ x 3.39″, W, D, H), the “86mm version” or
8cm x 1.6cm x 8cm (3.15″ x 0.63″ x 3.15″, W, D, H), the “80mm version”
WEIGHT:| 0.3kg (0.67lbs.) approx
ACCESSORIES:| K-Config software
OPTIONS:| RS-232 9-pin D-sub port to 3-pin terminal block connector cable
(C-D9F/3PM-0.6)
- Download up-to-date Kramer user manuals and guides from the Internet at this URL: http://www.kramerelectronics.com
- Specifications are subject to change without notice
LIMITED WARRANTY
Kramer Electronics (hereafter Kramer ) warrants this product free from defects
in material and workmanship under the following terms.
HOW LONG IS THE WARRANTY
Labor and parts are warranted for seven years from the date of the first
customer purchase.
WHO IS PROTECTED?
Only the first purchase customer may enforce this warranty.
WHAT IS COVERED AND WHAT IS NOT COVERED
Except as below, this warranty covers all defects in material or workmanship
in this product. The following are not covered by the warranty:
- Any product which is not distributed by Kramer, or which is not purchased from an authorized Kramer dealer. If you are uncertain as to whether a dealer is authorized, please contact Kramer at one of the agents listed in the Web site www.kramerelectronics.com.
- Any product, on which the serial number has been defaced, modified or removed, or on which the WARRANTY VOID TAMPERED sticker has been torn,
- Damage, deterioration or malfunction resulting from:
i) Accident, misuse, abuse, neglect, fire, water, lightning or other acts of nature
ii) Product modification, or failure to follow instructions supplied with the product
iii) Repair or attempted repair by anyone not authorized by Kramer
iv) Any shipment of the product (claims must be presented to the carrier)
v) Removal or installation of the product
vi) Any other cause, which does not relate to a product defect
vii) Cartons, equipment enclosures, cables or accessories used in conjunction with the product IF reattached, removed or otherwise interfered with.
WHAT WE WILL PAY FOR AND WHAT WE WILL NOT PAY FOR
We will pay labor and material expenses for covered items. We will not pay for
the following:
- Removal or installations charges.
- Costs of initial technical adjustments (set-up), including adjustment of user controls or programming. These costs are the responsibility of the Kramer dealer from whom the product was purchased.
- Shipping charges.
HOW YOU CAN GET WARRANTY SERVICE
- To obtain service on you product, you must take or ship it prepaid to any authorized Kramer service center.
- Whenever warranty service is required, the original dated invoice (or a copy) must be presented as proof of warranty coverage, and should be included in any shipment of the product. Please also include in any mailing a contact name, company, address, and a description of the problem(s).
- For the name of the nearest Kramer authorized service center, consult your authorized dealer.
LIMITATION OF IMPLIED WARRANTIES
All implied warranties, including warranties of merchantability and fitness
for a particular purpose, are limited in duration to the length of this
warranty.
EXCLUSION OF DAMAGES
The liability of Kramer for any effective products is limited to the repair or
replacement of the product at our option. Kramer shall not be liable for:
- Damage to other property caused by defects in this product, damages based upon inconvenience, loss of use of the product, loss of time, commercial loss; or:
- Any other damages, whether incidental, consequential or otherwise. Some countries may not allow limitations on how long an implied warranty lasts and/or do not allow the exclusion or limitation of incidental or consequential damages, so the above limitations and exclusions may not apply to you.
This warranty gives you specific legal rights, and you may also have other
rights, which vary from place to place.
NOTE: All products returned to Kramer for service must have prior
approval. This may be obtained from your dealer.
This equipment has been tested to determine compliance with the requirements
of:
EN-50081: “Electromagnetic compatibility (EMC); generic emission
standard.
Part 1: Residential, commercial and light industry”
EN-50082: “Electromagnetic compatibility (EMC) generic immunity standard.
Part 1: Residential, commercial and light industry environment”.
CFR-47: FCC* Rules and Regulations:
Part 15: “Radio frequency devices Subpart B Unintentional radiators”
CAUTION!
Servicing the machines can only be done by an authorized Kramer technician.
Any user who makes changes or modifications to the unit without the expressed
approval of the manufacturer will void user authority to operate the
equipment.
Use the supplied DC power supply to feed power to the machine.
Please use recommended interconnection cables to connect the machine to other
components.
- FCC and CE approved using STP cable (for twisted pair products)
For the latest information on our products and a list of Kramer distributors, visit our Web site: www.kramerelectronics.com, where updates to this user manual may be found.
We welcome your questions, comments and feedback.
Caution
Safety Warning:
Disconnect the unit from the power supply before opening/servicing.
Kramer Electronics, Ltd.
Web site: www.kramerelectronics.com
E-mail: info@kramerel.com
P/N: 2900-000546 REV 3
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>