PACKAGE CONTENTS
1×XS01 Portable Wireless Speaker
1×USB-C Charging Cable
1×User Manual
Product name | Infinix XS01 |
---|---|
Bluetooth version | 5.3 (only support BDR,EDR,BLE 1M) |
Speaker | 52mm |
Battery capacity | 1200mAh |
Charging input | 5V/700mAh |
Talk or music | About 12 hours (50% volume) |
Charging time | About 3 hours |
Operating range | 10M |
Output Power | 5W |
Connection Type | USB-C 5V |
PRODUCT OVERVIEW MUSIC CONTROL
POWER
Press and hold 2s: Power on
Press and hold 5s: Power of
BLUETOOTH
Click the pairing name and connect with device
Press 4 times : Reset
Press 5times: Clear pairing record
Click the pairing name and connect with device
MUSIC CONTROL
Press and hold: Previous track
ON CALLS
Press 1 time: Answer call
Press 1 time: Hang up call
Press and hold 2s: Reject call
Press 2 times : SIRl / Google Assistant
CONNECTIONS
TF mode: short press power on/off button, it can be read when the TF card
is inserted. FM Mode: short press power on/off button after power on, can be
turn it to FM Mode.
BATTER
Low battery:
“Low battery” warning at 10% charge, it will warn again at 5%; Speaker will
power off when battery is at 1% charge.
Power on:
The blue light will flash for 1s, before powering On.
Power off:
The blue light will flash for 1s, before powering Off.
Auto Power off:
After 3min of inactivity speaker will automatically power off.
Charging: Indicator light will turn on solid red.
Charging complete : About 2-2.5 Hours to full charge, red light will turn
off.
TWS FUNCTION
Press and hold on either speakers, A short sound will be heard The two speakers are connected in TWS mode. Connect one of the speakers to your device. To cancel the TWS connection: press and hold on both speakers for 2 seconds
Click the pairing name and connect with device
CAUTION:
- Risk of explosion if battery is replaced by an incorrect type, dispose of used batteries according to the instructions.
- disposal of a battery into fire or a hot oven, or mechanically crushing or cutting of a battery, that can result in an explosion;
- leaving a battery in an extremely high temperature surrounding environment that can result in an explosion or the leakage of flammable liquid or gas;
- a battery subjected to extremely low air pressure that may result in an explosion or the leakage of flammable liquid or gas.
- EUT Temperature: 0 ℃~+45℃(Standalone).
Frequency Range(RF):
BT/BLE: 2402-2480MHz(TX/RX);
FM: 87.5-108MHz(RX)
RF output power (only for CE
BT:627 dBm
BLE : 759 dBm
EU Declaration of Conformity
In accordance with EU Directives and Regulations
Company name : INFINIX MOBILITY LIMITED Address: FLAT N 16/F BLOCK B
UNIVERSAL INDUSTRIAL CENTRE 19-25 SHAN MEI STREET FOTAN NT, Hong Kong as the
manufacturer hereby declares under our sole responsibility that the,
Product(s): Portable Wireless Speaker
Model name : XS01
is in conformity with the essential requirements of the RE Directiv 2014/53/EU:
Radio Article 3.2
EN 300328 V2.2.2 (2019-07)
ETSI EN 303 345-1 V1.1.1 (2019-06) ETSI EN 303 345-3 V1.1.1 (2021-06)
EMC Article 3.1(b)
EN 55032:2015+A1:2020
EN 55035:2017+A11:2020 EN 61000-3-3:2013+A2:2021 EN 301 489-1 V2.2.3(2019-11);
Draft ETSI EN 301 489-17 V3.2.5 (2022-08);
EN IEC 61000-3-2:2019+A11:2021
Safety Article 3.1(a) EN IEC 62368-1:2020+A11:2020
Health Article 3.1(a) EN 62479:2010&EN 50663:2017
An EU Type Examination Certificate for this Product was issued in accordance with Annex III (Module B) of the 2014/53/EU Radio Equipment Directive by Bay Area Compliance Laboratories Corp. (2014/53/EU Radio Equipment Directive Notified Body Identification Number 1313)
Signed on behalf of INFINIX MOBILITY LIMITED (Signature of authorized person)
Jerry Liu
Signature: Jerry
Certified Engineer
Date: 2023-04-06
FCC Caution :
Any Changes or modifications not expressly approved by the party responsible
for compliance could void the user’s authority to operate the equipment.
This device complies with part 15 of the FCC Rules. Operation is subject to
the following two conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
IMPORTANT NOTE:
Note: This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses and
can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to connected. which the receiver is
- Consult the dealer or an experienced radio/TV technician for help.
FCC Radiation Exposure Statement:
This equipment complies with FCC radiation exposure limits set forth for an
uncontrolled environment.
FCC ID: 2AIZN-XS01