SPECIFICATIONS
ELECTRICAL DATA
TYPE | Cooling & Heating |
---|---|
INDOOR UNIT | AUYG30LRLE |
DECORATION PANEL | UTG-UGYA-W |
OUTDOOR UNIT | AOYG30LETL |
COOLING CAPACITY | 8.5 kW |
HEATING CAPACITY | 10.0 kW |
POWER SOURCE | 230 V, 50 Hz |
RUNNING CURRENT | Cooling |
Heating | 12.2 A |
INPUT WATTS
| Cooling| 2.65 kW| 3.12 kW
Heating| 2.77 kW| 3.02 kW
E.E.R Cooling| 3.21 kW/kW| 3.21 kW/kW
COP Heating| 3.61 kW/kW| 3.71 kW/kW
MOISTURE REMOVAL| 2.5 L/hr| 3.5 L/hr
AIRCIRCULATION INDOOR| 1,600 m3/hr| 1,800 m3/hr
AIRCIRCULATION OUTDOOR| 3,600 m3/hr| 3,800 m3/hr
MAXIMUM CURRENT| Cooling| 17.0 A| 18.5 A
Heating| 17.0 A| 20.0 A
FAN SPEED
INDOOR UNIT
| Discrimination| MFF-54TVM
---|---|---
High speed| 570 r.p.m.| 640 r.p.m.
Medium speed| 510 r.p.m.| 510 r.p.m.
Low speed| 470 r.p.m.| 470 r.p.m.
Quiet| 420 r.p.m.| 420 r.p.m.
OUTDOOR UNIT| Discrimination| MFE-60TVT
Speed| 850 r.p.m.| 900 r.p.m.
NOISE LEVEL
INDOOR UNIT
| High speed| 40 dB| 43 dB
---|---|---|---
Medium speed| 38 dB| 38 dB
Low speed| 36 dB| 36 dB
Quiet| 32 dB| 32 dB
OUTDOOR UNIT| Cooling| 53 dB| 54 dB
Heating| 55 dB| 55 dB
COMPRESSOR AND REFRIGERANT
COMPRESSOR TYPE
| Hermetic type, Inverter, 6 poles,
DC motor, Twin Rotary
---|---
DISCRIMINATION| N-TF30ND1A
WEIGHT (with oil)| 15.3 kg
PRECHARGED REFRIGERANT| 2,100 g
REFRIGERANT TYPE| R410A
MAX PIPE LENGTH| 50 m
MAX PIPE HEIGHT| 30 m
Pipe length FULL CHARGE| 20 m| 2,100 g
30 m| 2,500 g
40 m| 2,900 g
50 m| 3,300 g
ADDITIONAL CHARGE| 40 g/m
DIMENSIONS
INDOOR UNIT H x W x D | 288 x 840 x 840 mm |
---|---|
DECORATION PANEL H x W x D | 50 x 950 x 950 mm |
OUTDOOR UNIT H x W x D | 830 x 900 x 330 mm |
WEIGHT
INDOOR UNIT Net / Shipping | 26 kg | / 31 kg |
---|---|---|
DECORATION PANEL Net / Shipping | 5.5 kg | / 8.5 kg |
OUTDOOR UNIT Net / Shipping | 61 kg | / 68 kg |
DIMENSIONS
(Unit : mm)
INDOOR UNITDDECORATION PANEL
OUTDOOR UNIT
REFRIGERANT SYSTEM DIAGRAM
CIRCUIT DIAGRAM
INDOOR PCB CIRCUIT DIAGRAM
INDOOR UNIT MAIN PCB
- AUYG30LRLE : K06AK-120EHSE-C1
- AUHG36LRLE : K06AK-120FHSE-C1
INDOOR UNIT INDICATOR PCB ( OPTION ) K06AG-1000HSE-D0
OUTDOOR PCB CIRCUIT DIAGRAM
OUTDOOR UNIT
OUTDOOR UNIT AOYG30LETL FILTER PCB K05CW-0901HUE-FL0
AOYG36LETL FILTER PCB K05CW-0900HUE-FL0
- OUTDOOR UNIT AOYG30LETL CAPACITOR PCB K05FB-0901HUE-P0
- AOYG36LETL CAPACITOR PCB K05FB-0900HUE-P0
ERROR DETECTION
INDOOR UNIT and WIRED REMOTE CONTROL
If you use a wireless remote control, the lamp on the photo detector unit will
output error codes by way of blinking patterns. If you use a wired type remote
control, error codes will appear on the remote control display. See the lamp
blinking patterns and error codes in the table. An error display is displayed
only during running.
Remote control
This is possible only on a wired remote control.If an error occurs, the
following display will be shown.(“Er” will appear in the set room temperature
display.)
Indoor unit display (option)
OUTDOOR UNIT
SPECIAL INSTALLATION SETTING
PUMP DOWN (Refrigerant collecting operation) Perform the following procedures
to collect the refrigerant when moving the indoor unit or the outdoor unit.
- Press the push-button switch on the circuit board once. The LED on the circuit board starts flashing (one second ON/one second OFF). This indicates the start of the PUMP DOWN operation. When the switch is pressed while the compressor is in operation, the PUMP DOWN operation starts automatically. When the switch is pressed while the compressor is in stop, the compressor starts to operate automatically, and then moves on to PUMP DOWN operation.
- PUMP DOWN operation continues for about 1 minute. When the PUMP DOWN operation is completed, the compressor stops automatically. Then close the 2-way valve and 3-way valve immediately.
- Turn the power off.
PARTS
DECORATION PANEL UTG-UGYA-W
Ref.| Description| Part number|
---|---|---|---
1| Intake Grille Assy| 9378565012|
2| Intake Grille| 9378249011
3| Long Life Filter| 9378252011
4| Filter Guide| 9378253018
5| Hook Bracket| 9378435018
6| Grille Hook| 9378250017
DECORATION PANEL UTG-UGYA-W
Ref.| Description| Part number|
---|---|---|---
11| Decoration Panel| 9378242012|
12| Corner Panel A| 9378243019
13| Corner Panel (FUJITSU)| 9378243026
14| Panel Cover A| 9378261013
15| Panel Cover B| 9378262010
16| Drain Cover| 9378359017
DECORATION PANEL UTG-UGYA-W
Ref. | Description | Part number |
---|---|---|
21 | Flap | 9378254015 |
22 | Poli Slider | 9375541019 |
23 | Joint C | 9378357013 |
24 | Step motor | 9900467005 |
25 | Gear A | 9378256019 |
26 | Motor Holder | 9378255012 |
27 | Joint A | 9378258013 |
28 | Joint B | 9378259010 |
29 | Gear B | 9378257016 |
30 | Joint Shaft | 9378260016 |
31 | Flap Spring | 9378356016 |
Ref.| Description| Part number|
---|---|---|---
1| Bell Mouth| 9378227019|
2| Terminal Wire Cover| 9378548015
3| Hook R| 9378197015
4| Hook L| 9378198012
Ref.| Description| Part number|
---|---|---|---
11| Float Switch Sub Assy| 9378593015|
12| Sensor Holder| 9378329010
13| Float Switch| 9900465018
14| Drain Pump Sub Assy| 9378592018
15| Pump Assy| 9900464011
16| Drain Pump Holder B| 9375518011
17| Pump Rubber| 9378426016
18| Drain Hose| 9378212015
19| Drain Port| 9378213012
20| Drain Pan Assy| 9378207011
–| Drain Hose| 9379665001
–| Hose Band| 9379757010
Ref.| Description| Part number|
---|---|---|---
21| Evaporator Total Assy| 9378580015| |
22| Top Plate Assy| 9378395015
23| Cabinet A Sub Assy| 9378594012
24| Cabinet B Sub Assy| 9378595019
25| Cabinet C Sub Assy| 9378570016
26| Turbo Fan Assy| 9378228016
27| Turbo Fan Washer| 9378394018
28| Motor, DC Brushless| 9603373009
9602716005
29| Rubber (Motor)| 9378223011
| |
Ref.| Description| Part number|
---|---|---|---
31| Power Supply PCB| 9707398366|
32| Main PCB (30)| 9709245231
32| Main PCB (36)| 9709245248
33| Terminal 3P| 9306489045
34| Terminal 3P| 9703345012
35| Thermistor Holder A| 9378206014
36| Thermistor Holder B| 9378330016
37| Room Thermistor| 9900445010
38| Pipe Thermistor| 9900470012
39| Remote Control| 9318593013
Ref.| Description| Part number|
---|---|---|---
1| Protective Net| 9375381011|
2| Thermo Holder| 9375211011
3| Top Panel Sub Assy| 9374417032
4| Front Panel Sub Assy| 9374414079
5| Service Panel Sub Assy| 9374415052
6| Emblem Rear| 9351355005
7| Right Panel Sub Assy| 9374416127
8| Valve Cover| 9374174010
9| Fan Motor| 9602843015
10| Propeller Fan Assy| 9366378020
| | 9366378037
11| Base Assy| 9374166138
12| Drain Assy| 9303029015
13| Drain Cap| 313166024302
OUTDOOR UNIT
Ref.| Description| Part number|
---|---|---|---
21| Transistor PCB (IPM) (30)| 9707669077|
21| Transistor PCB (IPM) (36)| 9707669060
22| ACTPM| 9707592016
23| Choke Coil (30)| 9900390020
23| Choke Coil (36)| 9900223014
24| Capacitor PCB (30)| 9707257052
24| Capacitor PCB (36)| 9707257045
25| Main PCB (30)| 9707667868
25| Main PCB (36)| 9707667875
26| Filter PCB (30)| 9707128215
26| Filter PCB (36)| 9707128208
27| Terminal| 9900203023
28| Heat Sink| 9378530010
29| Thermistor (36 only)| 9704265012
30| Discharge Thermitor| 9900461003
31| Thermistor (Outdoor)| 9900463007
32| Compressor Thermistor| 9900466015
33| Heat Exchanger Thermistor| 9900462000
Ref.| Description| Part number|
---|---|---|---
41| 3-way Valve Assy| 9377958013|
42| 3-way Valve Assy| 9377959010
43| Compressor| 9810135001
44| Accumulator| 9385005006
45| Solenoid| 9970055034
46| Expansion Valve Coil| 9900057039
47| Wire w/Terminal for comp.| 9707837032
Ref.| Description| Part number|
---|---|---|---
51| Expansion Valve Assy| 9370947144|
52| Condenser A Sub Assy| 9374420308
53| Condenser A Assy| 9374433056
54| Inlet Pipe (Cond) A Assy| 9373461067
55| Outlet Pipe (Cond) A Assy| 9374266104
56| Strainer Assy| 9372524015
57| 4-way Valve Assy| 9374425198
58| 4-way Valve| 9900164010
59| Check Joint Assy| 9372802038
60| Muffler| 9372369050
61| Pressure Switch| 9900186012
ACCESSORIES
INDOOR UNIT
DECORATION PANEL
OUTDOOR UNIT
OPTIONAL PARTS