Gopher CPS-6011 60V DC Switching Power Supply
Panel Layout
- Volt Meter: Display the setting voltage or the actual output voltage
- Current Meter: Display the setting current or the actual output current, or output state: OFF, OVP, OCP, OTP
- Constant Voltage Indicator
- Constant Current Indicator
- Voltage/Current Select Switch:
- V: adjust voltage
- A: adjust current
- Adjust Knob: Push to shift the digit
- Output ON or OFF
- LOCK or WATT
- LOCK or WATT Indicator
- Output Terminal: Red +, Black –
- AC Power Switch
- AC Power Socket
- Operating Voltage Select Switch:
- 115: Rated Input 100-120Vac
- 230 : Rated Input 200-240Vac
Function and Operation
-
Set Voltage
Put the switch to “V”, click the adjusting knob to select adjust digit, and then adjust the knob to set the highlight digit. -
Set Current
Put the switch to “A”, click the adjusting knob to select adjust digit, and then adjust the knob to set the highlight digit. -
Turn on or turn off output
when the output is turned off, the Amp Meter shows “OFF” , press , the output turns on, press the button again the output turns off. -
Set the output ON at the AC power on
Press for 5 seconds, Amp Meter shows “d On” for 2 seconds, the output turns on at the AC power on, go back to set the output turn off at AC Power on, press button for 5 seconds again, Amp Meter shows “d OFF” -
Lock
This function is configured on the model without suffix “ L”. Press ,the lock light turns on , and adjusting knob are disabled. Press again to cancel lock function. -
Display the output power
This function is configured on the model with suffix “ L ” . Press , the power indicator turns on and Amp Meter displays the output power for 3 seconds
Protection
-
Output short circuit protection
When the output is short circuit, the power supply works on C.C mode, Amp Meter shows the short circuit current. -
Over Voltage Protection
Tracking over voltage protection, the OVP value is relevant to the setting voltage. When OVP is triggered, the output is shutdown, Amp Meter displays “OUP”, click to reset the OVP if the over voltage problem has been Q resolved. -
Over Current Protection resolved
Tracking over current protection, the OCP value is relevant to the setting current. When the OCP is triggered, the output is shutdown, the Amp Meter display “OCP”, click . to reset the OCP if the over current problem has been resolved. -
Over Temperature Protection
The MCU monitor the temperature of the power supply, if the temperature is higher than the special value, the output is shut down; Amp Meter displays “OTP”, click is lower. button to reset the OTP if the temperature