AILE X5 Upper Aram Blood Pressure Monitors User Guide

June 14, 2024
AILE

AILE X5 Upper Aram Blood Pressure Monitors

AILE-X5-Upper-Aram-Blood-Pressure-Monitors-product

Dear Customer
Thank you for choosing our
products and services.
IT is our goal to provide high quality self-health monitoring devices that are easy to use in your daily life. To minimize environmental impact, the AC adapter and AAA batteries are not included. If any of our accessories or products fail to meet your expectations, please contact us immediately. We are always ready to assist you.

  • AAA batteries
  • Longer USB cable
  • USB adapter
  • Other size cuff

support@4aile.com
+ 1 888-875-0846

Install Batteries

Tip:
For accurate results, avoid eating, drinking, or exercising 30 minutes before measurement and stay calm during the process.

  1. Push down the hook of the battery cover and pull downward.
  2. Insert 4 “AAA” alkaline batteries.
  3. Close the battery cover.

Apply The Arm Cuff

  1. Plug the arm cuff into the monitor.
  2. Apply the arm cuff onto your left upper arm. The bottom edge of the arm cuff should be 0.5 inch above the inside elbow. Downward.
  3. Attach the cuff firmly using the Velcro and keep a gap of  at least two fingers between the cuff and your skin. Make sure that air tube is located on the inside of the arm.

Sit Correctly

AILE-X5-Upper-Aram-Blood-Pressure-Monitors-fig \(7\)

Take a Measurement

  1. Press the [START /STOP] button.
  2. Remain still until the arm cuff deflates.
  3. After the measurement, your reading is displayed.
    To turn off the monitor, press the [START /STOP] button.

Error Resolution

If the monitor displays an error code, please refer to the troubleshooting table provided. If the issue persists and you are unable to resolve it, please contact us at support@4aile.com, and we will provide you with further solutions.

  • It means inflation has failed. Please check the cuff and ensure it is properly tied before trying again.
  • This could be due to a fast air leak rate or weak pulse mark. Check the cuff, retie it, and try measuring again.
  • It indicates that noise is interfering with blood pressure signal measurement. Measure again without any noise interference.
  • The measurement result may be incorrect, and re-measurement is necessary.
  • The inflation pressure exceeds 307±8mmHg (47 kPa±l kPa). Measure again within the recommended range.
  • Check if the batteries are inserted in the correct direction. You can also use the USB cable or replace the AAA batteries to try again.

Functions

Set the Time:

  1. Turn off the device and hold down the SET button for 3 seconds.
  2. Use the MEM button to adjust the year, then press SET to move on to adjusting the month, date, hour, and minute.
  3. Once you finish adjusting everything, press SET again to confirm.
    Note: Every time you replace batteries, the time will reset to zero. If you make a mistake during setup, reinstall the battery and start over.

To Switch Users:

  1. When the blood pressure monitor is off and the “START” button has not been pressed, press the “SET” button.
  2. The current user 1 will appear on the screen. Press “SET” again to switch to user 2.

To View Historical Data:

  1. When the blood pressure monitor is off and the “START” button has not been pressed, press the “MEM” button to view recent historical data.
  2. Pressing the “MEM” button again will display the second-to-last set of data, and so on for previous sets of data.

FAQs

Why are my blood pressure readings sometimes different?
Your blood pressure changes constantly based on your daily activities and time of day. Because of this, some fluctuations can be expected. That’s why it is important to use averages over time to compare readings. Because each person is different, it is important to consult with your physician about what your numbers mean to you.

Why could my physician’s reading be different than my readings taken at home?
Having your blood pressure measured by a healthcare professional in a physician’s office can cause nervousness and may result in an elevated reading. Because these readings can vary considerably, you should take your blood pressure on a regular basis at home and share your results with your healthcare provider.

Why was my blood pressure high when I was measured?
There are a variety of factors that can lead to high blood pressure values. Common ones include taking a measurement right after drinking coffee, taking a shower or some physical activity. Being too nervous, moving or talking during the measurement, and not having your arm at the level of your heart can lead to biased measurements.
It is recommended that you stay relaxed and sit quietly at the table while measuring. For other questions you can read the instructions first.
If the value of multiple measurements are different, you need to measure two to three times and take the average value. If you have any questions, you can tell us. We provide 7*24H consultation for AILE Blood Pressure monitor )
Common reasons for inaccurate measurements.

  1. The cuff is too tight or too loose. When measuring blood pressure, the cuff should be tightened appropriately. Too tight or too loose will have a greater effect on the blood pressure value (it is best to keep 2 fingers free between the cuff and the arm) The cuff is tied 0.5inch above the elbow joint of the arm.
  2. Incorrect position of the blood pressure measurement. When measuring blood pressure, the arm should be positioned cor rectly and the height of the sphygmomanometer, the cuff and the heart should be the same, otherwise the results will be affected .
  3. Inadequate self-preparation: being in an emotionally unstable state when measuring blood pressure, or not resting after strenuous exercise, talking while taking blood pressure, etc. will usually result in a high measured blood pressure value; (no food, water or exercise for 30 minutes before the measurement and emotional stability)

This product comes with a 5-year extended warranty.
Please contact us without hesitation if you require any assistance. We are always pleased to offer help whenever possible.
support@4aile.com
+ 1 888-875-0846
https://4aile.com

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals