Single Unit Rapid Charger FOR RECHARGEABLE TWO-WAY RADIO BATTERIES
American Communication Systems Discover the Power or Communtabons http://www.ameradio.com
User Manual Model: EC-4173

Overview

The EC-4I73 will charge LiPo. Li-Ion, NiMH. and NiCd batteries. This model is compatible with the radios listed below.
Charger Model   …..EC-4173
Compatible Radios…. Motorola CP150. C P200. CP2000. CP200-XLS. CP250. EP450. PR400
If you have questions concerning radio or battery compatibility, contact a Power Products dealer, visit swrw.powerproducts.com, or call customer service at 1300.529-11318.
Important

  1. Always charge new batteries completely before initial use. Recycle batteries when they can no longer be used. Do not discard unwanted batteries in the trash or incinerate them. Batteries exposed to fire or excessive heat may explode.
  2. For best battery performance. charge NiCd and NiMH batteries when they are fully discharged.
  3. Use chargers in areas protected from the weather. Do not expose the charger to rain, any liquids, or excessive moisture.
  4. Make sure contacts in the charging pod and on the battery are clean. Do not allow wire or metal objects to touch contacts in the charging pod or any internal part of the charger.
  5. Do not remove the charger’s housing or make any modifications to the charger. 6. Use only the power supply provided with EC-4173. If a replacement is required. order TWCI.PS.

Charging A Battery

  1. Connect the charger to an AC wall outlet with the power supply provided.
  2. Place the battery to be charged in the charger. The battery may also be charged while attached to the radio.
  3. When a battery is placed in the charger and while charging, the status LED will illuminate RED with no flashing to indicate normal charging. If the status LED is red and Rashes, a fault has been detected.
  4. When the battery is charged to 90% of capacity, the status LED will change to GREEN and begin to flash. The status LED will illuminate GREEN with no flashing when the battery is fully charged.
  5. When a battery is removed from the charger, wait for the status LED to go off before inserting another battery.
  6. Charge batteries when they are between 0°C and 45°C 132′ F – 113° F). Do not charge a battery when it is frozen (below / 32′ Fl or when it is excessively warm to the touch (45`C / 113° For above). Charging automatically terminates if battery temperature reaches 45°C while charging.

Fault Conditions

When the status LED flashes RED, a fault condition exists. The fault conditions are as follows:

  • The battery has a short circuit. This warning is provided after the pre-charge stage is completed. Remove the battery from the charger and recycle it.
  • The battery is under charged. This warning is provided after the rapid charge stage is completed and indicates the battery is nearing or at end of its life.

Warranty And Service During Warranty

Power Products Unlimited, LLC.(PPUlwarrants this product to be free for effects workmanship and materials for one year from the date of purchase by the end user. This warranty applies to the original purchaser and is void it the product has been altered, misused, damaged, neglected, or if repair is required because of normal wear and tear. This is the only warranty made by PPU. In no event will PPU, its affiliates, subsidiaries, related entities, or their respective directors, officers, or employees, be able for any damage beyond repair or replacement as described above, including without limitation, indirect incidental or consequential damages. For service under warranty. return the product along with dated proof of purchase to the retailer where purchased or to Power Products. If returning directly to Power Products. follow these instructions:

  • Send to Power Products – Warranty Service Department. 2170 Brandon TraiL Alpharetta, GA 30004. For your protection, we recommend you obtain proof of delivery for your shipment.
  • Include with your product dated proof of purchase, your name, daytime telephone number, and return address (street address only: return shipments cannot be made to a P.O. Box).

EC-4173 Charger Specifications

Dimensions (W x L x H) 114.3 x 114.9 x 50.2 mm / 4.50 x 4.52 x 1.97 inches
Weight 0.14 kg / 0.32 lbs. (charger only)
Compatible Chemistries Li-Ion / LiPo / NiMH / NiCd 0°
Operating Temperature C — 45° C / 32° F— 113° F
Power Supply Input 100V — 240V AC / 50 Hz — 60 Hz / 0.5A
Charger Input 12V-24V DC/ 1.0A (minimum)
Charge Rate 700 mA (10.6V-13.5V)
Approvals FCCA / UL (power supply only)

(A) This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Specifications are subject to change without notice.

ENDURA EC-4173 Single Unit Rapid Charger for Rechargeable Two Way Radio
Batteries iconEndura Chargers By Power Products
2170 Brandon Trail
Alpharetta, GA 30004 www.powerproducts.com

Co2018 Power Products Unlimited, LLC. Power Products and Endura are trademarks of Power Products Unlimited, LLC. All rights reserved.
American Communication Systems Discover the Power of Communications http://www.ameradio.com

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

ENDURA User Manuals

Related Manuals