Ritfit T700 LED Device User Manual
- June 4, 2024
- Ritfit
Table of Contents
- Ritfit T700 LED Device
- Brief description
- Parameter description
- KEY FUNCUT WRIPTION
- KEY FUNCTION AND OPERATION INSTRUCTIONS
- Description
- Precautions:
- DESCRIPTION OF EXERCISE MODE
- Body Fat Test Function Description
- Hand-holding Heartbeat Function Declaration
- Description of the sleep function
- Description of the security lock function
- Audio Bluetooth and Bluetooth APP Function Description
- Description of the speed switching function
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Ritfit T700 LED Device
Brief description
Functions of this electronic meter:
- Audio Bluetooth Play Function
- Sport Show APP Function
- Hand-holding Heartbeat Function
The terms used in the instructions are defined as follows:
- Parameters of the treadmill: “Speed” value.
- Movement parameters: “Distance” value, “Time” value, “Calorie” value.
Exercise Mode: manual, mode, program
- Manual exercise mode: The exercise mode that does not set the amount of exercise. Countdown exercise mode: The exercise mode with a specific amount of exercise Automatic
- program exercise mode: Different exercise programs are self-set inside the treadmill. 12 exercise programs are set inside the treadmill.
Parameter description
Movement parameters in various exercise modes:
- Minimum display speed !km/h
- Maximum display speed (when folded 6km/h, when erected 12km/h)
- Maximum exercise time in time mode: 99 minutes
- Minimum exercise time in time mode: 8 minutes
- Maximum exercise distance in distance mode: 99 kilometers
- Minimum exercise distance in distance mode: 1 kilometer
- Maximum number of calories burned in calorie mode: 990
- Minimum number of calories burned in calorie mode: 20
( PO 1-P 12) Minimum running time of automatic program: 8 minutes
( PO 1-P 12) Maximum running time of automatic program: 99 minutes
KEY FUNCUT WRIPTION
Function keys of the key board:
- Start key Stop key
- Program key Mode key
- Speed+ key Speed – key
- 2 speed shortcut key C3,6)
KEY FUNCTION AND OPERATION INSTRUCTIONS
-
Start key/ Stop key–Function description: start /stop the motor operation
Operation instructions:- when the electronic meter is in in full manual operation mode, press this key to start the motor
E0S, indicates that the lower control has detected information prompt of motor over-current protection
Solutions to common problems of EOS| The treadmill load exceeds the
rated
operating current of the motor| It is recommended to operate within the
rated operating current range of the motor
---|---|---
The problem with the assembly structure of the treadmill and the motor
causes motor resistance or blockage| Check whether the treadmill is
working
properl y
The lower control system fails| Replace the lower control for maintenance
E06, Indicates that the lower control has detected an abnormal phenomenon prompt of lower drive power voltage
Solutions to common| The supply voltage is too low|
Please check whether the power supply line
is normal
---|---|---
problems of E06| The detection circuit
control board fails| of| the| lower| Replace the lower control for maintenance
|
E07 or–, Prompt of improper placement of the security lock of the electronic meter
Solutions to
common| The security magnet has fallen away| Please place the security lock in
the designated position of the electronic meter
---|---|---
problems of E07 or—| The security lock system of the
electronic meter is faulty| Replace the
maintenance| electronic| meter| for
|
If your treadmill failure is not within the above range, please contact the customer service center of the platform where you purchased this product immediately, and we will certainly provide you a satisfactory service.
Description
Other download and installation functions except for automatic resource update provided by us are not available for this product. Product design may he modified without advance notice as required by product improvement.
Precautions:
- Check whether the treadmill is reliably grounded before use.
- Check whether the power is loaded first and whether the safety lock is effective before exercise.
- In case of any abnormal condition during exercise, the treadmill will be decelerated quickly and stop after pulling off the safety lock.
- Contact the dealer for any question about this treadmill. Non-specialized persons are not allowed for disassembly or repair to avoid equipment damage.
Notice for Use
Thank you for selecting our product. Correct use of the treadmill will ensure
your safety and convenience. Before using the treadmill, please carefully read
the followings:
- The power can be connected after confirming that the treadmill is installed completely in line with the installation instructions. Attention should be paid not to blocking the plug of treadmill on the wall when placing it. A space of 0.8m shall be reserved in front for convenient insertion.
- A safety space of0.8m shall be respectively reserved at both sides of the treadmill, and a safety space of2m (length)
- I m (width) shall be reserved behind the treadmill.
- The power cord shall be inserted into the power socket with safe grounding. The power supply of electronic treadmill is dedicated. If the power cord is damaged, purchase it from the dealer, and replace it by a professional, or When the column is down, the maximum speed can only reach 6krn/h, and when the column is erected, the maximum speed can reach 12krn/h. When switching between these two operation modes, the treadmill must be stopped first.
Pl-P12 program movement diagram ( This is the program diagram of high speed mode. If you enter low speed mode, the speed above 6km will automatically run at 6km)
Time
interval
Program
| Set the time /20 periods = the running time of the upper and lower periods
---|---
| 23| | 45| 67| | 89| | | IO| II| 12| 13| 14| 15| 16| 17| 18| 19| 20
Pl| Speed| 2| | 3| 4| 5| | 4| 5| 5| 3| 4| 5| 4| 4| 4| 2| | | |
P2| Speed| 2| 4| 4| 5| 6| 4| 6| 6| 6| 4| 5| 6| 4| 4| 4| 2| 2| | 4|
P3| Speed| 2| 4| 4| 6| 6| 4| 7| 7| 7| 4| 7| 7| 4| 4| 4| 2| 4| | 3|
P4| Speed| | 5| 5| 6| 7| 7| | 7| 7| 8| 8| 5| 9| 5| 5| 6| 6| 4| 4|
PS| Speed| 2| 4| 4| 5| 6| 7| 7| 5| 6| 7| 8| 8| | 4| 3| 3| 6| | 4|
P6| Speed| 2| 4| 3| 4| 5| 4| 8| 7| 6| 7| 8| 3| 6| 4| 4| 2| 5| 4| 3|
P7| Speed| 2| | | 3| 4| 5| | 4| 5| 3| 4| | | 3| | 6| 6| 5| |
PS| Speed| 2| | | 6| 7| 7| 4| 6| 7| 4| 6| 7| 4| 4| 4| 2| | 4| 4|
P9| Speed| 2| 4| 4| | 7| 4| 7| 8| 4| | 9| 9| 4| 4| 4| 5| 6| | |
PIO| Speed| 2| 4| 5| 6| 7| | 4| 6| 8| | 6| 6| | 4| 4| 2| 4| 4| |
Pl I| Speed| | 4| 5| 9| 5| 9| 5| 5| 5| 9| | | 5| 5| 9| 9| 8| 7| 6|
Pl2| Speed| | 5| 8| 10| | 7| 10| 10| | | 10| 10| 6| 6| 9| 9| | 5| 4|
DC System Error Message Prompts of the Treadmill
E0l: indicates the prompt of abnormal communication between the electronic
meter and the electronic control
Solutions to common problems of EOI| The communication line of
the electronic meter is not connected, broken, or poorly connected|
Please reconnect the communication line
---|---|---
No signal output from the electronic
meter| Replace the electronic meter for maintenance
No signal output from the lower control| Replace the lower control
for maintenance
E02: indicates that an abnormal phenomenon is detected between the lower control and the motor
Solutions to| The motor cable is not connected| Please reconnect the motor
cable
---|---|---
common problems of E02| There is no voltage output or abnormal
voltage output to the lower control motor| Replace the lower control for
maintenance
The motor is defective| Replace the motor
E03: Indicates the prompt of an abnormal phenomenon in the detection speed of the lower control
Solutions to common
problems of E03| The PWM drive line of the lower control
board fails| Replace the lower control for maintenance
---|---|---
E04: Indicates that the lower control has detected information prompt of motor over-voltage protection
Solutions to
common| The treadmill load exceeds the rated
operating voltage of the motor| It is recommended to use within the rated
operating voltage range of the motor
---|---|---
problems of E04| The motor of the treadmill is abnormal| Replace the motor
The motor over-voltage detection
circuit of the lower control board fails| Replace the lower control for
maintenance
operation.
- when the electronic meter is in the countdown mode setting, press this key to start the motor operation.
- when the electronic meter is in the state of automatic program setting, press this key to start the motor operation.
- when the electronic meter is in operation, press this key to stop the motor operation.
Program/mode key—function description: Selection of the automatic program
Operation instructions:
- When the electronic meter is in full manual operation mode, press this key to enter the countdown mode setting
- When the electronic meter is in full manual operation mode, press this key to enter the state of automatic program setting
- Operation process in standby mode: time countdown – distance countdown – calorie countdown – automatic program selection
- Speed+/- key—function description: Speed value adjustment during operation and parameter value adjustment during parameter setting
Operation instructions:
- When the electronic meter is in operation, the running speed value can be adjusted
- Under the parameter setting state, the set parameter values can be adjusted
- Speed shortcut key—function description: Direct selection of the speed value during operation Operation instructions: When the electronic meter is in operation, press this key to directly select the corresponding speed value
DESCRIPTION OF EXERCISE MODE
-
Manual mode function
- Enter the manual mode: After the electronic meter is powered on and fully displayed, it enters the initial standby state. At this time, press the start key to enter the operation of manual mode.
- Operation description: The initial running speed is !km/h, and the time and distance windows start counting positively from zero. Press the speed adjustment key to adjust the running speed value.
The exercise time is more than 99:59 minutes, the system does not stop, and the time starts from zero.
-
B, Countdown mode functions
-
Enter the time countdown mode: In the full manual operation mode, press the mode key and select the time countdown mode. At this time, the time window will display 30:00 minutes and have a blinking display. The required running time can be set by the speed+/- key, the setting range is from 8:00 to 99:00 minutes, and then press the start key to enter the operation of the time countdown mode.
Operation description: Who the initial running speed is 1.0KM/H, the time window will start counting down according to the set running time, and the distance and calorie windows will start counting from zero. Press the speed adjustment key to adjust the running speed value. When the countdown of the set time reaches zero, the electronic meter will start to stop running slowly. -
Enter the distance countdown mode: 1n the full manual operation mode, press the mode key and select the distance countdown mode. At this time, the distance window will display 1.0 km and have a blinking display. The required running distance can be set by the speed+/- key, the setting range is from 1.0 to 99.0 km, and then press the start key to enter the operation of the distance countdown mode.
Operation description:
When the initial running speed is 1.0KM/H, the distance window will start counting down according to the set distance, and the time and calorie windows will start counting from zero. Press the speed adjustment key to adjust the running speed value. When the countdown of the set distance reaches zero, the electronic meter will start to stop running slowly. -
Enter the calorie countdown mode: In the full manual operation mode, press the mode key and select the calorie countdown mode. At this time, the calorie window will display 50 and have a blinking display. The required running calories can be set by the speed +/- key, the setting range is from 20 to 990, and then press the start key to enter the operation of the calorie countdown mode.
-
Operation description:
When the initial running speed is 1.0KM/H, the calorie window will start counting down according to the set calorie, and the time and distance windows will start counting from zero. Press the speed adjustment key to adjust the running speed value. When the countdown of the set calorie reaches zero, the electronic meter will start to stop running slowly.
Automatic program function Enter the automatic program:
In the full manual operation mode or in the state of mode setting, press the
program key to enter the automatic program selection. At this time, the time
window will display 30:00 minutes and have a blinking display (The required
running time can be set by the speed+/- key, the setting range is from 8:00 to
99:00 minutes), and then press the start key to enter the operation of the
automatic program.
- Operation description: The automatic program is divided into 20 segments, the speed value of each segment runs according to the preset value of the automatic program. The running time of each segment is 1/20 of the set time, and the time window will start counting down according to the set running time, and the distance and calorie windows will start counting from zero. Press the speed adjustment key to adjust the running speed value. When the program runs to the next segment, the speed will be automatically adjusted to the preset value of the next segment. When the countdown of the set time reaches zero, the electronic meter will start to stop running slowly.
Body Fat Test Function Description
Start the body fat test setting: In the setting state of initial standby state
or mode, press the program button to select to set the body fat test (press
the program button again to set the body fat test FAT under the Pl2 automatic
program setting state).
Setting instructions of body fat test: In the setting state of body fat test,
the speed window shows the parameter function (F-X), and the distance window
shows the set value. Press the speed+/key to adjust the set value, and press
the mode key to select to set the next item. Gender (F-1) setting for the
first item: initial value: I (setting range: 1-2, I for male and 2 for female)
- Age (F-2) setting for the second item: initial value: 25 (setting range: 10-99)
- Height (F-3) setting for the third item: initial value: 170 (setting range: 100-220cm)
- Weight (F-4) setting for the fourth item: initial value: 70 (setting range: 20-150kg)
- Body fat (F-5) setting for the fifth item: initial value: —
Body fat test: When the setting is completed, start the fifth item – body fat test, with initial display of “—“. At this time, hold the hands on the hand- holding heartbeat test steel sheet for about 5s to show the body fat test index.
Body fat index description: The body lipid index measures the relationship
between the height and the weight of a person, and it is applicable to
providing the basis of weight adjustment for any male or female with other
health indexes. The ideal body fat index shall be between 20 and 25. If the
index is less than 19, the person has the light weight. If the index is
between 26 and 29, the person is overweight. If the index exceeds 30, the
person is fat
(Note: such data is only used for reference instead of medical data).
Hand-holding Heartbeat Function Declaration
Hand-holding heartbeat function test method: Palms of both hands are respectively attached to the steel sheets of the left and right arnnests, and the person naturally holds the arnnests on both sides. After about 5s, the LCD heartbeat display window will show the initial value of heartbeat. Keep holding with both hands statically, and the heartbeat display window will show the variable data slowly. After 30s, the data is close to the currently actual value of heartbeat. Hand-holding heartbeat function instruction: Irregular heartbeat data will occur in case of the following situations:
- If the hand-holding force is too large during the hand-holding test. Keep the force appropriate.
- While running, the contact will constantly change when holding the hand-holding heartbeat arnnest for test at the same time. To test the hand-holding heartbeat, it is recommended to stop exercise, stand on two edges with both feet, and hold with hands statically.
- If the hand is dry or cold, or if the palm skin is particularly thick.
Note: The hand-holding heartbeat test data can be only used for exercise reference instead of medical data due to detection modes and many influence factors
Description of the sleep function
When the tad mill stops running without any operation for more than IO minutes, it will enter the sleep state, the LED display and related indicator light will automatically tum off, press any key to wake up the electronic meter. After full display, it will re-enter the initial standby state.
Description of the security lock function
In normal use, the security lock shall be placed in the designated position of the electronic meter before you can operate the electronic meter. When removing the security lock, LED display window of the electronic meter will display “–“. If the security lock is removed in the running state, the system will shut down quickly, and all movement data will be cleared after closing the safety lock again.
Audio Bluetooth and Bluetooth APP Function Description
After the electronic meter is powered on, in the standby state, turn on the Bluetooth in the phone settings, click “Search” to find out the name of Bluetooth (similar to “FS-DFDFA-A”). Click the name of Bluetooth, and then connect the Bluetooth to play the songs in the phone. For speed control by APP, download and open the Sport show APP. After entering the APP interface, click “Search” to find out the name of Bluetooth and click “Device connection”. After connection, operate the treadmill through APP.
Description of the speed switching function
This device complies with part 15 of the FCC Rules. Operation is subject to
the following two conditions: (1) this device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
Any changes or modifications not expressly approved by the party responsible
for compliance could void the user’s authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a
Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular
installation.
If this equipment does cause harmful interference to radio or television
reception,
which can be determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or more of the following
measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
The device has been evaluated to meet general RF exposure requirement. The device can be used in portable exposure condition without restriction