FIRMAN P08005 Generator User Guide
- June 4, 2024
- FIRMAN
Table of Contents
FIRMAN P08005 Generator
WARNING This Quick Reference Guide is not substitute for reading the operator’s manual. To reduce the risk of injurie or death, user must read and understand the operator’s manual before using this product. All pages references to the operator’s manual.
-
Unpack Generator: Remove generator, accessories, inserts and literature from carton. H any Hem is missing or damaged, contact our product service
department at 1-844-347-62&1
-
Install the wheel kit and power cord holder
-
Slide the axle pin(A) through the wheel(B) and mount point on the frame and flat washer(D). Secure them with cotter pin(C).
-
Attach the support leg (G) to the generator frame with flange bolt (E) (MBX16) and flange lock nut(F) (MB).
-
Secure handle (K) to the frame using bolt (H) (M8x50)| and flange nut (F) (MB).
-
Hang the power cord holder on the frame. Then tear off the liner of the tape on connection brackets ad stick them to the frame and insert the power cord on the holder.
-
Battery Cable
NOTE: The generator comes equipped with the positive (red) and negative (black) cables already attached to battery terminals. -
Cut wire tie that is binding the black battery cables A and B
-
Insert the male connector of cable A Into female connector of cable B.
-
Add Lubricant’s and Fuel
-
Use a funnel to pour provided engine oil into engine. Fil to the upper mark of the oil dipstick H.
-
Use clean fresh regular UNLEADED gasoline with a minimum 87 0ctane.
For questions or clarification on these Quick Reference Guide Instructions, contact us at: 1-844-347-6261, www.firmanpowerequipment.com
Start Generator Move generator outside to a flat, level surface, away from
doors, windows and vents. A DANGE Typical Generator Shown Using a general
indoors CAN KILL YO Generator exhaust contains carbon
- Turn fuel valve under tank to ON
- Turn engine switch located on control panel to RUN(position.
- Flip the battery switch to the ON(1) position
Remote Start
Push and release the START
button
Electric Start
- Move choke lever located on engine to START position
- Flip the engine switch to the START ( II ) position
- Move choke lever to RUN Position
Recall Start
- Move choke lever located on engine to START position
- Pull cord starter to start engine
- Move choke lever to RUN Position
Plug In Items to be powered, using only grounded extension cords
Shutdown and Storage
Remove any load from the generator
Push and release the 11STOP11 button on the remote control.
SKIP THIS STEP, IF YOU ARE NOT USING REMOTE START
Run the generator at no load for 2 minutes and then turn engine switch to OFF (0) position
Flip the battery switch to the OFF (0) position
Turn fuel valve to OFF (0) position
NOTE
THE BATTERY SWITCH ALWAYS SHOULD BE IN “OFF” (0) POSITION AT THE ENO OF USE TO
PREVENT BATTERY DRAIN EL
If generator Is to be stored for longer than 30 days, refer to The operator’s
- null for further Instruction.