VESTA-063 Universal Wireless Double Technology Outdoor Detector User Manual
- June 4, 2024
- VESTA
Table of Contents
VESTA-063 Universal Wireless Double Technology Outdoor Detector
You can connect to VESTA-063, any radio transmitter are placed in the slot,
making it compatible with any existing wireless system
Thanks to its low power consumption, can ‘be powered by the same battery of
the transmitter you wish to use, or, alternatively, with a battery 3.6 Volts
Lithium.
Is an outdoor miniaturized double technology detector, particularly suitable
for being installed on shutters. Its characteristics make it suitable for any
external place, and wherever it is necessary to protect some specific areas.
VESTA-063, in fact, creates a very narrow curtain barrier (about 7.5°) and it
has an adjustable covered area up to 12m. It is realized with atmospheric
resistant agents material and it is protected from a watertight cover.
Moreover its electronic card is covered with resin capable to assure its
correct working in every atmospheric condition. Accurate planning and digital
microwave signals analysis make VESTA-063 a very stable sensor.
TEST MODE
Open the lid, bring the Dip4 ON, close the lid. By now, the LEDs are always active and the sensor does not inhibit more. Adjust the flow rate of the infrared and / or microwave. Tests completed open the lid, bring the Dip4 to OFF and close the lid. For further 3 minutes, the sensor is still in test .. After this time, the sensor enters low-power mode.
LOW BATTERY
In the case in which the sensor is not powered by the battery of the transmitter, but by the internal battery (supplied separately) bring the dip1 ON. When the battery voltage drops below the preset threshold, the yellow LED flashes for a each (approximately) 2 seconds.
DISPLAY INTRUSION
Bringing DIP3 to ON, the sensor activates the red LED for a few seconds, whenever it detects an intrusion. The signaling affects power consumption by decreasing the battery life .. Please note that after each detection, the sensor remains inactive for at least 3-6 minutes (see dip2).
DIAGRAM
DECTION CHART
MOUNTING
Use a screw driver to remove hidden screw fixing cover (in upside detector)
General installation guide
Installation example of wall protection. Install at about 2,1m. It can be
installed also in upper floors at about 2,1m referring to an horizontal ground
larger than 1,5m (for example balcony, ledge. Be sure no obstacles prevent its
detection (gutter pipe, shutter)
Example of installation on shutters . Install on shutter at a 2,1 m height
from ground.
TECHNICAL CHARACTERISTICS
Parameter | Condition | Value |
---|---|---|
Power supply standard | 3-10V | |
Max power supply | 13,2 V | |
Medium consumption | 8 uA | |
Max consumption | 6 V sensor in allarm | 52 mA |
Protection power supp. inversion | Yes | |
Inibition time between alarm | Selectable by dip-switch | 3-6 minuti |
Range IR max | Temperature 25 °C | 12 m |
Range MW max | 12 m | |
Low battery reporting | Selectable by dip-switch | Yes |
Range Test | Selectable by dip-switch | Yes |
Alarm Output | C-NC-NA | |
Tamper Output | C-NC-NA | |
Setting IR range | Yes | |
Setting uW range | Yes | |
Frequency MW | 24,125 GHz | |
Vertical MW | 80° | |
Orizzontal MW | 32° | |
Vertical IR | 90° | |
Orizzontal IR | 7,5° | |
Warming time | 60 s | |
Working temperature | -20/+60 °C | |
Wheight | 131 g | |
Dimensions | H 129, L 40, P 48 mm |
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>