© 2023 Advantech Czech s.r.o. No part of this publication may be reproduced or transmitted in any form or by any means, electronic or mechanical, including photography, recording, or any information storage and retrieval system without written consent. Information in this manual is subject to change without notice, and it does not represent a commitment on the part of Advantech. Advantech Czech s.r.o. shall not be liable for incidental or consequential damages resulting from the furnishing, performance, or use of this manual. All brand names used in this manual are the registered trademarks of their respective owners. The use of trademarks or other designations in this publication is for reference purposes only and does not constitute an endorsement by the trademark holder.

Used symbols

  • Danger – Information regarding user safety or potential damage to the router.
  • Attention – Problems that can arise in specific situations.
  • Information – Useful tips or information of special interest.
  • Example – Example of function, command or script.

Changelog

1.1 Serial to network proxy (ser2net) Changelog

  • v1.0.0 (2017-07-24
    • First release.
  • v1.0.1 (2017-07-25)
    • Increased size of internal buffers. v1.0.2 (2017-08-21)
  • Fixed non valid telnet IAC in received data.
    • v1.0.3 (2017-11-12)
  • Upgraded ser2net to version 3.5. v1.0.4 (2018-02-28)
  • Increased chardelay-max to prevent splitting of the data to more packets.
    • v1.0.5 (2018-03-07)
  • Added option “Intercharacter Delay” into configuration.
  • Improved stopping of ser2net from init script.
    • v1.0.6 (2018-09-27)
  • Added expected ranges of values to JavaSript error messages.

Module Usage

Module Description
Router app is not contained in the standard router firmware. Uploading of this router app is described in the Configuration manual (see Chapter Related Documents). This router app is not v4 platform compatible. Configuration, which can be done in this router app, extends the basic configuration of the serial interface to communicate through the network, which can be configured in the GUI of the router (Configuration -> Expansion Port). The main benefit is that this module supports the configuration of the Telnet protocol supporting the RFC 2217 specification. RS232, RS485/422 or MBUSD serial interfaces of a router can be used for this purpose. These interfaces are available as an expansion ports, see [1], [2] and [3]. Some models of Advantech routers can have serial interface built-in by default. USB port of the router equipped with the USB to serial converter (FTDI) can also be used by this router app.

As a client’s application suitable for this purpose can be, for example, used Serial to Ethernet Connector application from Eltima Software or HW VSP application from HW group.

Web Interface

Once the installation of the module is complete, the module’s GUI can be invoked by clicking the module name on the Router apps page of router’s web interface. The main menu of module’s GUI is shown on figure 1. Left part of this GUI contains the menu with Status menu section, followed by Configuration menu section which contains the module’s configuration page named as Port1, Port2 and Port USB. Customization menu section contains only the Return item, which switches back from the module’s web page to the router’s web configuration pages.

Module Configuration
There are three configuration forms under Configuration menu section, for Port 1, Port 2 and Port USB. The first two forms are determined for configuration of communication parameters of devices connected to the router’s serial port 1 resp. port 2. Port USB form is determined for configuration of a device connected to the USB port equipped with a USB to serial converter. Layout for all three configuration forms is the same, see the figure 2.

All configuration items are described in table 1.ADVANTECH Serial To Network
Proxy Ser2net Router App 3

Continued from previous pageADVANTECH Serial To Network Proxy Ser2net Router
App 4

System Log
Log messages are available on System Log page, under Status menu section. This log contains log messages for this router app, but also all other router’s system messages and is exactly the same as the system log available on System Log page in router’s Status menu section.

Related Documents

  1. Advantech Czech: Expansion Port RS232 – User Manual (MAN-0020-EN)
  2. Advantech Czech: Expansion Port RS485/422 – User Manual (MAN-0025-EN)
  3. Advantech Czech: Expansion Port MBUSD – User Manual (MAN-0030-EN)
    You can obtain product-related documents on Engineering Portal at icr.advantech.cz address. To get your router’s Quick Start Guide, User Manual, Configuration Manual, or Firmware go to the Router Models page, find the required model, and switch to the Manuals or Firmware tab, respectively. The Router Apps installation packages and manuals are available on the Router Apps page. For the Development Documents, go to the DevZone page.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals