Ruijie Networks RG-RAP2266 Access Point User Guide
- June 14, 2024
- Ruijie Networks
Table of Contents
RG-RAP2266 Access Point
Product Information: Ruijie Reyee RG-RAP2266 Access Point
The Ruijie Reyee RG-RAP2266 Access Point is a hardware device
designed for network engineers, technical support and servicing
engineers, and network administrators. It is manufactured by Ruijie
Networks, a company known for its networking solutions. The access
point is equipped with advanced features and functionalities to
provide reliable and high-performance wireless connectivity.
Trademark Information: Ruijie Networks and other Ruijie Networks
logos mentioned in this document are trademarks of Ruijie Networks.
All other trademarks or registered trademarks mentioned in this
document are owned by their respective owners.
Disclaimer: The products, services, or features described in
this document may be subject to commercial contracts and terms.
Some or all of the described products, services, or features may
not be available for purchase or use. Ruijie Networks does not
provide any explicit or implicit warranties regarding the content
of this document. The content of this document may be updated
without notice.
Technical Support
- Official Website of Ruijie Reyee: https://www.ruijienetworks.com/products/reyee
- Technical Support Website: https://www.ruijienetworks.com/support
- Case Portal: https://caseportal.ruijienetworks.com
- Community: https://community.ruijienetworks.com
- Technical Support Email: service_rj@ruijienetworks.com
Conventions
This document follows certain conventions to convey information
effectively:
-
GUI Symbols: Boldface is used for button
names, window names, tab names, field names, menu items, and
links. -
Signs: Different signs are used to indicate
the importance and nature of alerts:-
Danger: An alert that calls attention to
safety instructions that, if not understood or followed, can result
in personal injury. -
Warning: An alert that calls attention to
important rules and information that, if not understood or
followed, can result in data loss or equipment damage. -
Caution: An alert that calls attention to
essential information that, if not understood or followed, can
result in function failure or performance degradation. -
Note: An alert that contains additional or
supplementary information that, if not understood or followed, will
not lead to serious consequences. -
Specification: An alert that contains a
description of product or version support.
-
Contents
This manual provides installation steps, troubleshooting,
technical specifications, and usage guidelines for cables and
connectors. It is intended for users who want to understand the
above and have extensive experience in network deployment and
management. Users are assumed to be familiar with related terms and
concepts.
Product Usage Instructions
To use the Ruijie Reyee RG-RAP2266 Access Point, please follow
the steps outlined in the installation and reference guide provided
by Ruijie Networks. The guide will provide detailed instructions on
how to set up and configure the access point for optimal
performance.
If you encounter any issues or require technical support, you
can visit the official website of Ruijie Reyee or access their
technical support website. Additionally, you can use the case
portal or community platform to seek assistance from other users
and experts. For direct technical support, you can reach out to
Ruijie Networks via email at service_rj@ruijienetworks.com.
It is important to note that the information provided in this
manual may be updated from time to time. Therefore, it is
recommended to refer to the latest version of the manual for
accurate and up-to-date instructions.
Ruijie Reyee RG-RAP2266 Access Point
Hardware Installation and Reference Guide
Document Version: V1.0 Date: February 15, 2023 Copyright © 2023 Ruijie
Networks
Copyright
Copyright © 2023 Ruijie Networks All rights are reserved in this document and
this statement. Without the prior written consent of Ruijie Networks, any
organization or individual shall not reproduce, extract, back up, modify, or
propagate the content of this document in any manner or in any form, or
translate it into other languages or use some or all parts of the document for
commercial purposes.
,
and other Ruijie networks logos are trademarks of Ruijie Networks.
All other trademarks or registered trademarks mentioned in this document are owned by their respective owners.
Disclaimer
The products, services, or features you purchase are subject to commercial
contracts and terms, and some or all of the products, services, or features
described in this document may not be available for you to purchase or use.
Except for the agreement in the contract, Ruijie Networks makes no explicit or
implicit statements or warranties with respect to the content of this
document.
The content of this document will be updated from time to time due to product
version upgrades or other reasons, Ruijie Networks reserves the right to
modify the content of the document without any notice or prompt.
This manual is designed merely as a user guide. Ruijie Networks has tried its
best to ensure the accuracy and reliability of the content when compiling this
manual, but it does not guarantee that the content of the manual is completely
free of errors or omissions, and all the information in this manual does not
constitute any explicit or implicit warranties.
Preface
Audience
This document is intended for: Network engineers Technical support and
servicing engineers Network administrators
Technical Support
Official Website of Ruijie Reyee:
https://www.ruijienetworks.com/products/reyee Technical Support Website:
https://www.ruijienetworks.com/support Case Portal:
https://caseportal.ruijienetworks.com Community:
https://community.ruijienetworks.com Technical Support Email:
service_rj@ruijienetworks.com
Conventions
1. GUI Symbols
Interface symbol
Description
Example
Boldface
1. Button names 2. Window names, tab name, field name and menu items 3. Link
1. Click OK. 2. Select Config Wizard. 3. Click the Download File link.
Multi-level menus items
Select System > Time.
2. Signs The signs used in this document are described as follows:
Danger An alert that calls attention to safety instruction that if not
understood or followed can result in personal injury.
Warning An alert that calls attention to important rules and information that
if not understood or followed can result in data loss or equipment damage.
Caution An alert that calls attention to essential information that if not understood or followed can result in function failure or performance degradation.
I
Note An alert that contains additional or supplementary information that if
not understood or followed will not lead to serious consequences.
Specification An alert that contains a description of product or version
support. 3. Note This manual provides installation steps, troubleshooting,
technical specifications, and usage guidelines for cables and connectors. It
is intended for users who want to understand the above and have extensive
experience in network deployment and management, and assume that users are
familiar with related terms and concepts.
II
Contents
Preface ………………………………………………………………………………………………………………………………… I 1 Product Overview
………………………………………………………………………………………………………………. 1
1.1 About the RG-RAP2266 Access Point ………………………………………………………………………….. 1 1.2
Package Contents………………………………………………………………………………………………………. 1 1.3 Hardware
Features …………………………………………………………………………………………………….. 2
1.3.1 Top Panel ……………………………………………………………………………………………………….. 2 1.3.2 Bottom
Panel…………………………………………………………………………………………………… 3 1.4 Technical Specifications
……………………………………………………………………………………………… 3 1.5 Power Specifications
………………………………………………………………………………………………….. 5 1.6 Cooling
Solution………………………………………………………………………………………………………….5 2 Preparing for
Installation …………………………………………………………………………………………………….. 6 2.1 Safety
Precautions………………………………………………………………………………………………………6 2.2 General Safety
Precautions………………………………………………………………………………………….6 2.3 Handling
Safety…………………………………………………………………………………………………………..6 2.4 Electric Safety
……………………………………………………………………………………………………………. 6 2.5 Installation Environment
Requirements………………………………………………………………………….7 2.5.1 Installation Requirements
…………………………………………………………………………………. 7 2.5.2 Ventilation Requirements
………………………………………………………………………………….. 7 2.5.3 Temperature/Humidity Requirements
…………………………………………………………………. 7 2.5.4 Cleanliness Requirements
………………………………………………………………………………… 7 2.5.5 Power Supply Requirements
…………………………………………………………………………….. 8 2.5.6 Anti-interference Requirements
…………………………………………………………………………. 9 2.6 Tools
………………………………………………………………………………………………………………………… 9
I
3 Installing the Access Point ………………………………………………………………………………………………… 10 3.1
Before You Begin………………………………………………………………………………………………………10 3.2 Precautions for
Installation ………………………………………………………………………………………… 10 3.3 Installing the Access
Point………………………………………………………………………………………….11 3.4 Bundling
Cables………………………………………………………………………………………………………..13 3.5 Checklist After
Installation …………………………………………………………………………………………. 13 3.6 Removing the Access
Point………………………………………………………………………………………..14
4 Verifying Operating Status ………………………………………………………………………………………………… 15 4.1
Setting up Configuration Environment………………………………………………………………………….15 4.2
Powering on the Access Point ……………………………………………………………………………………. 15 4.2.1
Checklist Before Power-on ……………………………………………………………………………… 15 4.2.2 Checklist
After Power-on ………………………………………………………………………………… 15
5 Monitoring and Maintenance………………………………………………………………………………………………16 5.1
Monitoring ……………………………………………………………………………………………………………….. 16 5.2 Maintenance
……………………………………………………………………………………………………………. 16
6 Troubleshooting………………………………………………………………………………………………………………..17 6.1 General
Troubleshooting Flowchart ……………………………………………………………………………. 17 6.2 Common
Faults…………………………………………………………………………………………………………17
7 Appendix………………………………………………………………………………………………………………………….18 7.1 Connectors and
Media……………………………………………………………………………………………….18 7.2 Cabling
……………………………………………………………………………………………………………………. 20
II
Hardware Installation and Reference Guide you want to appear here.
1 Product Overview
Error! Use the Home tab to apply 1 to the text that
1.1 About the RG-RAP2266 Access Point
The RG-RAP2266 is a high-performance ceiling-mount dual-radio Wi-Fi access
point designed to cover a largeand medium- -sized indoor area. The access
point adopts either IEEE 802.3at PoE power supply or 12 V DC/2 A local power
supply. Compliant with the IEEE 802.11a/b/g/n/ac Wave1/Wave2/ax standard, the
access point can work in both 2.4 GHz and 5 GHz frequency bands and supports
dual-stream MU-MIMO. The access point delivers a combined data rate of 2976
Mbps, with up to 574 Mbps in the 2.4 GHz band and 2402 Mbps in the 5 GHz band.
With built-in omnidirectional antennas and a Wi-Fi coverage radius of 40 m
(131.23 ft.), the access point can be deployed in various scenarios covering
offices, business, villas, hotels, and government.
1.2 Package Contents
Table 1-1 Package Contents Item RG-RAP2266 Access Point Mounting Bracket Screw Wall Anchor User Manual Warranty Card
Quantity 1 1 2 2 1 1
Note
The package contents generally contain the above items. The actual delivery is
subject to the order contract. And please check your goods carefully against
the order contract. If you have any questions, please contact the distributor.
1
Hardware Installation and Reference Guide you want to appear here.
1.3 Hardware Features
1.3.1 Top Panel
Error! Use the Home tab to apply 1 to the text that
Figure 1-1 Top Panel of a RG-RAP2266 Access Point
Note The CMIIT ID is printed on the product nameplate.
Table 1-2 LED Status
Description
Solid blue
The access point is operating normally with no alarms.
Off
The access point is not receiving power.
Fast flashing
The access point is starting up.
Slow flashing (at 0.5 Hz)
The network is unreachable.
Flashing twice in succession
Possible cases:
Restoring the access point to factory settings. Upgrading the firmware. Note:
Do not power off the access point in this case.
One long flash followed by three short flashes
A fault occurs.
2
Hardware Installation and Reference Guide you want to appear here.
1.3.2 Bottom Panel
Error! Use the Home tab to apply 1 to the text that
Figure 1-2 Bottom Panel of a RG-RAP2266 Access Point
Table 1-3 Ports and Reset Hole
No.
Item
Description
1
Reset Hole
Stick the pin into the Reset hole: Restart the access point.
Press and hold the pin to the Reset hole for more than 5 seconds: Restore the
access point to factory settings.
2
LAN/PoE Port
10/100/1000Base-T Ethernet port, supporting PoE input
3
DC Connector
12 V DC/2 A power supply
1.4 Technical Specifications
Table 1-4 Technical Specifications
Radio Design
Dual-radio, two spatial streams
Standard & Protocol
Concurrent 802.11ax, 802.11ac wave2/wave1, and 802.11a/b/g/n
Operating Radio
802.11b/g/n/ax: 2.4 GHz to 2.4835 GHz 802.11a/n/ac/ax: 5.150 GHz to 5.350 GHz, 5.470 GHz to 5.725 GHz, and 5.725 GHz to 5.850 GHz
Spatial Streams
2.4 GHz: two spatial streams, 2×2 MIMO 5 GHz: two spatial streams, 3×3 MIMO
Max. Data Rate
2.4 GHz: 574 Mbps 5 GHz: 2402 Mbps Combined: 2976 Mbps
3
Hardware Installation and Reference Guide you want to appear here.
Error! Use the Home tab to apply 1 to the text that
Modulation
OFDM: BPSK@6/9 Mbps, QPSK@12/18 Mbps, 16QAM@24 Mbps, and 64QAM@48/54 Mbps DSSS: DBPSK@1 Mbps, DQPSK@2 Mbps, and CCK@5.5/11 Mbps MIMO-OFDM: BPSK, QPSK, 16QAM, 64QAM, 256QAM, and 1024QAM OFDMA
Receive Sensitivity
11b: 91 dBm (1 Mbps), 90 dBm (5.5 Mbps), 87 dBm (11 Mbps) 11a/g: 89 dBm (6 Mbps), 82 dBm(24 Mbps), 78 dBm (36 Mbps), 72 dBm ( 54 Mbps) 11n: 85 dBm (MCS0), 67 dBm (MCS7), 62 dBm (MCS8) 11ac: 20 MHz: 85 dBm (MCS0), 62 dBm (MCS8) 11ac: 40 MHz: 82 dBm (MCS0), 59 dBm (MCS8) 11ac: 80 MHz: 79 dBm (MCS0), 53 dBm (MCS9) 11ac: 160 MHz: 76 dBm (MCS0), 50 dBm (MCS9) 11ax: 20 MHz: 85 dBm (MCS0), 62 dBm (MCS8), 58 dBm (MCS11) 11ax: 40 MHz: 82 dBm (MCS0), 59 dBm (MCS8), 54 dBm (MCS11) 11ax: 80 MHz: 79 dBm (MCS0), 53 dBm (MCS9), 52 dBm (MCS11) 11ax: 160 MHz: 76 dBm (MCS0), 49 dBm (MCS11)
Power Adjustment
Configurable in increments of 1 dBm
Dimensions (W x D x H)
220 mm x 220 mm x 52.6 mm (8.66 in. x 8.66 in. x 2.07 in., without the mounting bracket)
Weight
0.5 kg (1.10 lbs, without the mounting bracket)
Service Port Management Port Status LED Power Supply
Max. Power Consumption Temperature
One 10/100/1000/1000Base-T Ethernet port, supporting PoE input N/A One LED
(Blue) There are two power supply modes available:
PoE+ power supply: IEEE 802.3at-compliant Local power supply: 12 V DC /2 A
Note: The power adapter is an optional accessory (inner diameter: 2.1 mm/0.08
in., outer diameter: 5.5 mm/0.22 in., and depth: 9 mm/0.35 in.). 18 W
Operating temperature: 0°C to 40°C (32°F to 104°F) Storage temperature: 40°C
to +70°C (40°F to +158°F)
4
Hardware Installation and Reference Guide you want to appear here.
Error! Use the Home tab to apply 1 to the text that
Humidity
Operating humidity: 5% to 95% RH (non-condensing) Storage humidity: 5% to 95% RH (non-condensing)
Certification
CE
MTBF
400,000 hours
1.5 Power Specifications
The access point can be powered by either PoE or DC power supply. Caution
If the access point adopts DC power supply, a Ruijie-certificated 12 V DC/2A
power adapter is required. The DC adapter needs to be purchased separately.
If the access point adopts PoE power supply, connect the LAN/PoE port of the
access point to a PoEcapable port of a switch or power sourcing equipment
(PSE). Make sure that the PSE is 802.3at-capable.
1.6 Cooling Solution
The access point adopts a fanless design. Caution
Maintain a sufficient clearance around the access point for air circulation.
5
Hardware Installation and Reference Guide you want to appear here.
Error! Use the Home tab to apply 1 to the text that
2 Preparing for Installation
2.1 Safety Precautions
Note To prevent device damage and physical injury, please read the safety
recommendations carefully as
described in this chapter. Recommendations do not cover all possible hazardous
situations.
2.2 General Safety Precautions
Do not expose the AP to high temperature, dust, or harmful gases. Do not
install the AP in an area prone to fire or explosions. Keep the AP away from
EMI sources such as large radar stations, radio stations, and substations. Do
not subject the AP to unstable voltage, vibration, and noises. The
installation site should be dry. Keep the AP at least 500 meters away from the
ocean and do not face it
towards the sea breeze. The installation site should be free from water
including possible flooding, seepage, dripping, or condensation.
The installation site should be selected according to network planning and
communications equipment features, and considerations such as climate,
hydrology, geology, earthquake, electrical power, and transportation.
2.3 Handling Safety
Do not move the access point frequently. Turn off all power supplies and
unplug all power cables before you remove the device.
2.4 Electric Safety
Warning Any nonstandard and inaccurate electrical operation can cause an
accident such as fire or electric shock,
thus causing severe even fatal damages to humans and devices. Direct or
indirect contact with a wet object (or your finger) on the high voltage and
power line can be fatal.
Please observe local regulations and specifications when performing electrical
operations. Relevant operators must be qualified.
Carefully check for any potential hazards in the working area such as damp/wet
ground or floors.
6
Hardware Installation and Reference Guide you want to appear here.
Error! Use the Home tab to apply 1 to the text that
Find the location of the emergency power supply switch in the room before installation. Cut off the power supply first in case of an accident.
Be sure to make a careful check before shutting down the power supply.
Do not place the device in a damp/wet location. Do not let any liquid enter the chassis.
Keep the AP far away from grounding or lightning protection devices for power equipment.
Keep the AP away from radio stations, radar stations, high-frequency high- current devices, and microwave ovens.
2.5 Installation Environment Requirements
The AP must be installed indoors. To ensure normal operation, the installation
site must meet the following requirements.
2.5.1 Installation Requirements
Install the AP in a well-ventilated environment. If it is installed in a
closed room, make sure there is a good cooling system.
Make sure the site is sturdy enough to support the RG-RAP2266 and its
accessories. Make sure the site has enough space for installing the RG-RAP2266
and leave sufficient room around the
AP for ventilation.
2.5.2 Ventilation Requirements
The access point adopts natural cooling. Reserve a sufficient clearance around
the access point to ensure proper ventilation.
2.5.3 Temperature/Humidity Requirements
To ensure the normal operation and equipment service life, maintain
appropriate temperature and humidity levels in the equipment room. Improper
room temperature and humidity can cause damage to the device. High relative
humidity may affect insulation materials, resulting in poor insulation and
even electrical leakage.
Sometimes it may lead to changes in the mechanical properties of materials and
corrosion of metal parts. Low relative humidity can dry and shrink insulation
sheets and cause static electricity that can damage the
circuitry. High temperatures greatly reduce device reliability and shorten
service life.
2.5.4 Cleanliness Requirements
Dust poses a serious threat to device operation. Dust on the surface of the
device can be absorbed onto metal contact points by static electricity causing
poor contact. Electrostatic absorption of dust occurs more easily when the
relative humidity is low, and might shorten the equipment service life and
cause communication failures. The following table shows the maximum
concentration and diameter of dust allowed in the equipment room.
7
Hardware Installation and Reference Guide you want to appear here.
Maximum Diameter (m) 0.5
Maximum Concentration 1.4 × 107 (Particles/m3)
Error! Use the Home tab to apply 1 to the text that
1 7 × 105
3 2.4 × 105
5 1.3 × 105
The amount of salt, acids and sulfides in the air are also strictly limited for the equipment room. These substances can accelerate metal corrosion and aging of some parts. The following table describes the limits of some hazardous gases such as sulfur dioxide, hydrogen sulfide, nitrogen dioxide, ammonia gas and chlorine gas in the equipment room.
Gas
Average (mg/m3)
Maximum (mg/m3)
Sulfur dioxide (SO2)
0.2
1.5
Hydrogen sulfide (H2S)
0.006
0.03
Nitrogen dioxide (NO2)
0.04
0.15
Ammonia gas (NH3)
0.05
0.15
Chlorine gas (CI2)
0.01
0.3
Note Average refers to the average value of harmful gases measured in one week. Maximum indicates the upper limit of the harmful gas measured in one week for up to 30 minutes every day.
2.5.5 Power Supply Requirements
DC power adapter: 12 V DC/2A. The technical specifications of the DC connector
are as follows:
Inner Diameter
Outer Diameter
Depth
Conductor Resistance
Voltage Resistance
Voltage for Insulator and Conductor Test)
Polarity Symbol
2.10 ± 0.05 5.50 ± 0.05
mm
mm
9 mm
(0.35 5
(0.83 in. ±
(0.22 in. ± in.)
0.002 in.)
0.002 in.)
100 M
1000 V
Center (tip) of the output plug: Positive (+)
Barrel (ring) of the output plug: Negative (-)
Reverse polarity symbol is not allowed.
8
Hardware Installation and Reference Guide you want to appear here.
Error! Use the Home tab to apply 1 to the text that
PoE injector: IEEE 802.3at-comliant.
Caution The DC input power should be greater than the power actually consumed
by the access point. You are advised to use a DC power adapter with
specifications recommended by Ruijie. You are advised to use a Ruijie-
certified PoE injector.
2.5.6 Anti-interference Requirements
Keep the access point as far away from the lightning prevention equipment and
grounding equipment of the power device as possible.
Keep the access point far away from radio stations, radar stations, high-
frequency high-current devices, and microwave ovens.
2.6 Tools
Table 2-1 Tools Common Tools
Phillips screwdrivers, power cords, Ethernet cables, cage nuts, diagonal pliers, and binding straps
Special Tools
Antistatic gloves, wire stripper, crimping pliers, crystal connector crimping pliers, and wire cutter
Meter
Multimeter
Relevant Devices PC, display, and keyboard
Note The RG-RAP2266 is delivered without a tool kit. The tool kit is customer- supplied.
9
Hardware Installation and Reference Guide you want to appear here.
Error! Use the Home tab to apply 1 to the text that
3 Installing the Access Point
The RG-RAP2266 access point must be installed and used indoors. Caution
Before installing the access point, make sure you have carefully read the
requirements described in Chapter 2.
3.1 Before You Begin
Carefully plan and arrange the installation position, networking mode, power
supply, and cabling before installation. Confirm the following requirements
before installation: The installation site provides sufficient space for
proper ventilation. The installation site meets the temperature and humidity
requirements of the access point. The power supply and required current are
available in the installation site. The selected power supply modules meet the
system power requirements. The installation site meets the cabling
requirements of the access point. The installation site meets the site
requirements of the access point. The customized access point meets the
client-specific requirements.
3.2 Precautions for Installation
To avoid damage to the access point, observe the following safety precautions:
Do not power on the access point during installation. Install the access point
in a well-ventilated location. Do not expose the access point to high
temperature. Keep the access point away from high voltage cables. Install the
access point in indoor scenarios. Do not expose the access point to
thunderstorm or strong electric field. Keep the access point clean and dust-
free. Cut off the power switch before cleaning the access point. Do not wipe
the device with a damp cloth. Do not wash the device with liquid. Do not open
the enclosure when the access point is working. Secure the access point
properly.
10
Hardware Installation and Reference Guide you want to appear here.
3.3 Installing the Access Point
Error! Use the Home tab to apply 1 to the text that
Caution
You are advised to install the access point where you can get the optimal Wi-
Fi coverage. In indoor scenarios, the Wi-Fi coverage of a ceiling-mount access
point is larger than that of a wall-mount access point. You are advised to
install the access point on the ceiling.
Image is for indicative purpose only and may not represent exact equipment.
(1) Take out the mounting bracket from the packaging material and use the
mounting bracket as a template to mark the mounting holes’ positions. Drill
two holes at 80 mm (3.15 in) spacing on the wall or ceiling.
Figure 3-1 Drilling Two Holes on the Wall or Ceiling
(2) Secure the mounting bracket to the ceiling or wall by using self-tapping screws. Figure 3-2 Securing the Mounting Bracket to the Wall or Ceiling
11
Hardware Installation and Reference Guide you want to appear here.
Error! Use the Home tab to apply 1 to the text that
(3) Connect the Ethernet cable to the LAN/PoE port on the rear of the access point. See 7.1 Connectors and Media for the supported wiring for twisted pairs.
Caution Avoid a small bend radius at the connector of the cable. You are advised not to use an Ethernet cable with an RJ45 boot.
Figure 3-3 Connecting the Ethernet Cable to the LAN/PoE Port
(4) Align the round feet at the bottom of the access point over the mounting
holes on the bracket. Slide the AP into the mounting bracket. Caution
Install the Ethernet cable properly before securing the access point to the
mounting bracket. The access point can be installed in any of four directions
on the mounting bracket depending on how
you route the Ethernet cable. The round feet should fit easily into the
mounting holes. Do not force the round feet into the mounting
holes. After installation, verify that the access point is secured properly.
12
Hardware Installation and Reference Guide you want to appear here.
Error! Use the Home tab to apply 1 to the text that
Figure 3-4 Securing the Access Point to the Mounting Bracket
3.4 Bundling Cables
Caution The power cords and other cables should be bound in a visually
pleasing way. When you bundle twisted pairs or fiber-optic cables, make sure
that the cables at the connectors have
natural bends or bends of large radius. Do not over tighten cable bundle as it
may reduce the cable life and performance.
The steps for cable bundling are as follows: (1) Bundle the drooping part of
the cables and place the bundle as near the ports as possible. (2) Route the
cables under the access point and run in straight line.
3.5 Checklist After Installation
(1) Checking Access Point Verify that the external power supply matches with
the requirement of the access point. Verify that the access point is securely
fastened. (2) Checking Cable Connection Verify that the UTP/STP cable matches
with the port type. Verify that cables are properly bundled.
13
Hardware Installation and Reference Guide you want to appear here.
Error! Use the Home tab to apply 1 to the text that
(3) Checking Power Supply
Verify that the power cord is properly connected and compliant with safety requirements.
Verify that the access point functions properly after power-on.
3.6 Removing the Access Point
Hold the access point in your hands and push it upward and away from the
mounting bracket.
14
Hardware Installation and Reference Guide you want to appear here.
Error! Use the Home tab to apply 1 to the text that
4 Verifying Operating Status
4.1 Setting up Configuration Environment
If the access point is powered by PoE or DC power adapter, verify that the
power cord is properly connected and compliant with safety requirements.
4.2 Powering on the Access Point
4.2.1 Checklist Before Power-on
Verify that the power cord is properly connected. Verify that the input
voltage meets with the requirement of the access point.
4.2.2 Checklist After Power-on
Verify that the LED works normally Verify that the mobile phone or other
wireless device can discover the SSID broadcast by the access point.
If multiple devices exist on the network, use SSID @Ruijie-mXXXX. If only one
device exists on the network, use SSID @Ruijie-sXXXX.
15
Hardware Installation and Reference Guide you want to appear here.
Error! Use the Home tab to apply 1 to the text that
5 Monitoring and Maintenance
5.1 Monitoring
When RG-RAP2266 is operating, you can monitor its status by observing the LED.
See Table 1-2 LED for details.
5.2 Maintenance
If the hardware is faulty, please contact Ruijie technical support for help.
16
Hardware Installation and Reference Guide you want to appear here.
6 Troubleshooting
Error! Use the Home tab to apply 1 to the text that
6.1 General Troubleshooting Flowchart
Start
Check whether the AP is installed properly.
Check whether the power supply is properly connected.
Check whether the LED is normal.
Check whether cables are properly connected with ports.
Contact Ruijie technical support to check whether hardware faults exist.
Finish
6.2 Common Faults
The status LED is still off after the access point is powered on. If the
access point is powered by PoE, verify that the power sourcing equipment (PSE)
should be at least 802.3at-capable and the Ethernet cable is connected
properly. If the access point is powered by a DC adapter, verify that the
adapter has mains input and works properly.
The Ethernet port does not work after the Ethernet cable is plugged in. Check
whether the peer device is working properly. Then verify that the Ethernet
cable is capable of providing the required data rate and is properly
connected.
The client cannot find the access point. Verify that the access point is
properly powered. Verify that the Ethernet port is correctly connected. Verify
that the access point is correctly configured. Move the client to adjust the
distance between the client and the access point.
17
Hardware Installation and Reference Guide you want to appear here.
7 Appendix
Error! Use the Home tab to apply 1 to the text that
7.1 Connectors and Media
1000BASE-T/100BASE-TX/10BASE-T Port
1000BASE-T/100BASE-TX/10BASE-T is a 10/100/1000 Mbps port that supports auto-
negotiation and auto MDI/MDIX Crossover. Compliant with IEEE 802.3ab,
1000BASE-T requires Category 6 or Category 5e 100-ohm UTP or STP (STP is
recommended) with a maximum distance of 100 meters (328.08 feet). 1000BASE-T
port uses four twisted pairs for data transmission, all of which must be
connected. Twisted pairs for the 1000BASE-T port are connected as shown in the
following figure.
Figure 7-1 Four Twisted Pairs Connection
Straight-Through
(Switch)
(Switch)
Crossover
(Switch)
(Switch)
100BASE-TX/10BASE-T port can also be connected by cables of the preceding specifications. Besides, the 10BASE-T port can be connected by 100-ohm Category 3, Category 4, and Category 5 cables with a maximum distance of 100 meters (328.08 feet). 100BASE-TX port can be connected by 100-ohm Category 5 cables with a maximum distance of 100 meters (328.08 feet). The following table lists definitions of pin signals for the 100BASE-TX/10BASE-T port.
Table 7-1 100BASE-TX/10BASE-T Pin Assignments
Pin 1 2 3 6 4, 5, 7, 8
Socket Input Receive Data+ Input Receive DataOutput Transmit Data+ Output Transmit DataNot Used
Plug Output Transmit Data+ Output Transmit DataInput Receive Data+ Input Receive DataNot Used
18
Hardware Installation and Reference Guide you want to appear here.
Error! Use the Home tab to apply 1 to the text that
The following figure shows feasible connections of the straight-through and crossover twisted pairs for a 100BASETX/10BASE-T port.
Figure 7-2 100BASE-TX/10BASE-T Connection
Straight-Through
((SSwwitictchh) )
(Switch)
(Switch)
Crossover
(Switch)
19
Hardware Installation and Reference Guide you want to appear here.
Error! Use the Home tab to apply 1 to the text that
7.2 Cabling
During installation, route cable bundles upward or downward along the sides of
the rack depending on the actual situation in the equipment room. All cable
connectors used for transit should be placed at the bottom of the cabinet
rather than be exposed outside of the cabinet. Power cords are routed beside
the cabinet, and top cabling or bottom cabling is adopted according to the
actual situation in the equipment room, such as the positions of the DC power
distribution box, AC socket, or lightning protection box.
(1) Requirements for Cable Bend Radius The bend radius of a fixed power cord,
network cable, or flat cable should be over five times greater than
their respective diameters. The bend radius of these cables that are often
bent or plugged should be over seven times greater than their respective
diameters. The bend radius of a fixed common coaxial cable should be over
seven times greater than its diameter. The bend radius of the common coaxial
cable that is often bent or plugged should be over 10 times greater than its
diameter. The bend radius of a fixed high-speed cable (such as an SFP+ cable)
should be over five times greater than its diameter. The bend radius of the
fixed high-speed cable that is often bent or plugged should be over 10 times
greater than its diameter.
(2) Precautions for Bundling up Cables Before cables are bundled, mark labels
and stick the labels to cables wherever appropriate. Cables should be neatly
and properly bundled in the rack without twisting or bending.
Figure 7-3 Bundling up Cables
Twisted
Bent
Cables of different types (such as power cords, signal cables, and grounding
cables) should be separated in cabling and bundling. Mixed bundling is
disallowed. When they are close to each other, you are advised to adopt
crossover cabling. In the case of parallel cabling, maintain a minimum
distance of 30 mm (1.18 in.) between power cords and signal cables.
The cable management brackets and cabling troughs inside and outside the
cabinet should be smooth without sharp corners.
The metal hole traversed by cables should have a smooth and fully rounding
surface or an insulated lining.
20
Hardware Installation and Reference Guide you want to appear here.
Error! Use the Home tab to apply 1 to the text that
Use cable ties to bundle up cables properly. Please do not connect two or more cable ties to bundle up cables.
After bundling up cables with cable ties, cut off the remaining part. The cut should be smooth and trim, without sharp corners.
Figure 7-4 Bundling up Cables
When cables need to be bent, you should first bundle them up. However, the
buckle cannot be bundled within the bend area. Otherwise, considerable stress
may be generated in cables, breaking cable cores.
Figure 7-5 Bundling up Cables
Cables not to be assembled or remaining parts of cables should be folded and
placed in a proper position of the rack or cable trough. The proper position
refers to a position that does not affect device running or damage the device
or cable.
220 V and 48 V power cords must not be bundled on the guide rails of moving
parts. The power cords connecting moving parts such as grounding cables should
be reserved with some access
after being assembled to avoid suffering tension or stress. After the moving
part is installed, the remaining cable part should not touch heat sources,
sharp corners, or sharp edges. If heat sources cannot be avoided, high-
temperature cables should be used. If heat sources cannot be avoided, high-
temperature cables should be used. When screw threads are used to fasten cable
terminals, the anchor or screw must be tightly fastened.
21
Hardware Installation and Reference Guide you want to appear here.
Figure 7-6 Cable Fastening
Error! Use the Home tab to apply 1 to the text that
1. Flat Washer 2. Nut
3. Spring Washer 4. Flat Washer
Hard power cords should be fastened in the terminal connection area to prevent
stress on terminal connection and cable.
Do not use self-tapping screws to fasten terminals. Power cords of the same
type and in the same cabling direction should be bundled up into cable
bunches,
with cables in cable bunches clean and straight. Binding by using buckles
should be performed according to Table 7-1.
Table 7-2 Cable Bunch Cable Bunch Diameter 10 mm (0.39 in.) 10 mm to 30 mm (0.39 in. to 1.18 in.) 30 mm (1.18 in.)
Distance between Every Binding Point 80 mm to 150 mm (3.15 in. to 5.91 in.) 150 mm to 200 mm (5.91 in. to 7.87 in.) 200 mm to 300 mm (7.87 in. to 11.81 in.)
No knot is allowed in cabling or bundling. For wiring terminal blocks (such as
air switches) of the cold pressing terminal type, the metal part of the cord
end terminal should not be exposed outside the terminal block when assembled.
22