RENOGY 3000W REGO Inverter Charger User Manual
- June 14, 2024
- Renogy
Table of Contents
RENOGY 3000W REGO Inverter Charger
Product Information
- Product Name: REGO Inverter Charger
- Model: 12V 3000W (VERSION A0)
- Type: Pure Sine Wave Inverter Charger
Product Usage Instructions
Applicability:
- This user manual applies to the REGO 12V 3000W Inverter Charger (RIV1230RCL-1SS-G1).
Disclaimer:
- The information and specifications provided in this user manual are subject to change without notice due to continual product improvements.
- It is the responsibility of the user to install and use the product in compliance with the user manual.
- The illustrations in the user manual are for demonstration purposes only and may not reflect the actual product.
- Renogy reserves the right to change the information in the user manual without notice. For the latest version, visit renogy.com
Copyright and Trademark:
- The product is copyrighted by Renogy.
- The Renogy trademark is used to identify the manufacturer of the product.
Table of Contents:
- Important Safety Information
- General Safety Information
- Introduction
- General Information
- Key Features
- Optional Accessories
- Product Overview
- Device-side Wiring
- AC Input Wiring
- Automatic Generator Start
- Communication
Safety Information:
- Refer to the “Important Safety Information” and “General Safety Information” sections of the user manual for detailed safety instructions.
General Information:
- The user manual provides general information about the REGO Inverter Charger.
Key Features:
- The REGO Inverter Charger is a 12V 3000W pure sine wave inverter charger.
Optional Accessories:
- Refer to the “Optional Accessories” section of the user manual for information on additional accessories that can be used with the REGO Inverter Charger.
Product Overview:
- Refer to the “Product Overview” section of the user manual for a detailed description and visual representation of the REGO Inverter Charger.
Device-side Wiring:
- Refer to the “Device-side Wiring” section of the user manual for instructions on how to properly wire the device.
AC Input Wiring:
- Refer to the “AC Input Wiring” section of the user manual for instructions on how to properly wire the AC input.
Automatic Generator Start:
- Refer to the “Automatic Generator Start” section of the user manual for information on how to set up and use the automatic generator start feature.
Communication:
- Refer to the “Communication” section of the user manual for information on how to establish communication with the REGO Inverter Charger.
REGO
Inverter Charger
12V 3000W
VERSION A0
ON OFF
CHC AC / INV
FAULT
HBpleiegAfahoRsrveeNoIwrlNetaoaGgrdkeit,nhingeooinrndsetthrruistcotpiaorovndosuidccatr.risekfusl,ly
Pure Sine Wave Inverter Charger
USER MANUAL
Applicability
The user manual applies to the following product: z REGO 12V 3000W Inverter
Charger (RIV1230RCL-1SS-G1)
Disclaimer
z 5HQRJHQVXUHVWKHDFFXUDFVXFLHQFDQGWKHDSSOLFDELOLWRILQIRUPDWLRQLQWKHTXLFN guide
at the time of printing due to continual product improvements that may occur.
z 5HQRJDVVXPHVQRUHVSRQVLELOLWRUOLDELOLWIRUSHUVRQDODQGSURSHUWORVVHVZKHWKHU
GLUHFWODQGLQGLUHFWOFDXVHGEWKHXVHr’s failure to install and use the product in
compliance with the user manual.
z 5HQRJLVQRWUHVSRQVLEOHRUOLDEOHIRUIDLOXUHVGDPDJHVRULQMXULHVUHVXOWLQJIURPUHSDLU
DWWHPSWHGEXQTXDOL¿HGSHUVRQQHOLPSURSHULQVWDOODWLRQDQGRSHUDWLRQ
z The illustrations in the user manual are for demonstration purposes only.
Details may appear VOLJKWOGLHUHQWGHSHQGLQJRQSURGXFWUHYLVLRQDQGPDUNHWUHJLRQ
z Renogy reserves the right to change the information in the user manual
without notice. For the latest user manual, visit renogy.com.
Copyright
REGO 12V 3000W Inverter Charger User Manual © 2023 Renogy. All rights
reserved.
$OOLQIRUPDWLRQLQWKHXVHUPDQXDOLVVXEMHFWWRFRSULJKWDQGRWKHULQWHOOHFWXDOSURSHUWULJKWV
RI5HQRJDQGLWVOLFHQVRUV7KHXVHUPDQXDOPDQRWEHPRGL¿HGUHSURGXFHGRUFRSLHGLQ whole or
in part, without the prior written permissions of Renogy and its licensors.
Trademark
7KHIROORZLQJDUHUHJLVWHUHGWUDGHPDUNVRI5HQRJ
RENOGY
7KHUHJLVWHUHGWUDGHPDUNVLQWKHXVHUPDQXDODUHWKHSURSHUWRI5HQRJ7KHXQDXWKRUL]HGXVH RIWKHWUDGHPDUNVLVVWULFWOSURKLELWHG
March 2023, Revision A0
Date and Revision
Important Safety Information
Symbols Used
Important Safety Information
General Safety Information
The user manual provides important installation, operation, and maintenance
instructions for
REGO 12V 3000W Inverter Charger (hereinafter referred to as inverter charger).
Read the user
PDQXDOFDUHIXOOEHIRUHLQVWDOODWLRQDQGRSHUDWLRQDQGVDYHLWIRUIXWXUHUHIHUHQFH)DLOXUHWR
REVHUYHWKHLQVWUXFWLRQVRUSUHFDXWLRQVLQWKHXVHUPDQXDOFDQUHVXOWLQHOHFWULFDOVKRFNVHULRXV
LQMXURUGHDWKRUFDQGDPDJHWKHLQYHUWHUFKDUJHUSRWHQWLDOOUHQGHULQJLWLQRSHUDEOH7KH
LQVWDOODWLRQDQGVHUYLFHRIWKHLQYHUWHUFKDUJHUPLJKWUHTXLUHNQRZOHGJHRIKLJKYROWDJHHOHFWULFLW
DQGLVUHFRPPHQGHGWREHFDUULHGRXWETXDOL¿HGSHUVRQQHO
Symbols Used
7KHIROORZLQJVPEROVDUHXVHGWKURXJKRXWWKHXVHUPDQXDOWRKLJKOLJKWLPSRUWDQWLQIRUPDWLRQ
Indicates a potentially dangerous condition which could result in WARNING
injury or death.
Indicates a critical procedure for safe and proper installation and CAUTION
operation.
NOTE
Indicates an important step or tip for optimal performance.
INFO
Indicates that more information is available in other documents relating to the subject.
General Safety Information
WARNING
z 7KHYROWDJHRIWKHLQYHUWHUFKDUJHUH[FHHGVWKHKXPDQERGVDIHWYROWDJH5HDGDOO
LQVWUXFWLRQVDQGSUHFDXWLRQVLQWKHPDQXDOEHIRUHLQVWDOODWLRQ
z
,QVSHFWWKHLQYHUWHUFKDUJHUIRUDQYLVLEOHGDPDJHLQFOXGLQJFUDFNVGHQWVGHIRUPDWLRQDQG
RWKHUYLVLEOHDEQRUPDOLWLHVEHIRUHLQVWDOODWLRQ
z ‘RQRWSXQFWXUHGURSFUXVKSHQHWUDWHVKDNHVWULNHRUVWHSRQWKHLQYHUWHUFKDUJHU z Do
not open, dismantle, repair, tamper with, or modify the components of the
inverter
charger. z Install the inverter charger on a vertical surface indoors
protected from direct sunlight, high
WHPSHUDWXUHDQGZDWHU0DNHVXUHWKHUHLVJRRGYHQWLODWLRQ z
.HHSWKHLQYHUWHUFKDUJHUDZDIURPKHDWLQJHTXLSPHQW z
‘RQRWLQVHUWIRUHLJQREMHFWVLQWRWKHLQYHUWHUFKDUJHU z
‘RQRWLQVWDOOWKHLQYHUWHUFKDUJHUQHDUÀDPPDEOHIXPHVRUJDVHV z Keep the inverter
charger out of the reach of children. z
:HDUSURSHUSURWHFWLYHHTXLSPHQWDQGXVHLQVXODWHGWRROVGXULQJLQVWDOODWLRQDQGRSHUDWLRQ
‘RQRWZHDUPHWDOMHZHOUVXFKDVQHFNODFHVDQGZDWFKHV z Do not touch the connector
contacts while the inverter charger is in operation.
06
Important Safety Information
Symbols Used General Safety Information
z ‘LVFRQQHFWDOOFRQQHFWRUVIURPWKHLQYHUWHUFKDUJHUEHIRUHPDLQWHQDQFHRUFOHDQLQJ z
5LVNRIHOHFWULFVKRFN%HFDUHIXOZKHQWRXFKLQJEDUHWHUPLQDOVRIWKHLQYHUWHUFKDUJHUDV
they may retain high lethal voltages even after power is removed. z Do not
dispose of the inverter charger as household waste. Comply with local, state,
and
IHGHUDOODZVDQGUHJXODWLRQVDQGXVHUHFFOLQJFKDQQHOVDVUHTXLUHG z
,QWKHHYHQWRI¿UHXVH¿UHH[WLQJXLVKHUVVXLWDEOHIRUHOHFWULFDOHTXLSPHQW z
,IWKHLQYHUWHUFKDUJHULVLQVWDOOHGLPSURSHUORQDERDWLWPDFDXVHGDPDJHWRWKHFRUURVLYH
DJHQWVRIWKHERDW3OHDVHKDYHWKHLQYHUWHUFKDUJHULQVWDOOHGEDTXDOL¿HGHOHFWULFLDQ
CAUTION
z ‘RQRWH[SRVHWKHLQYHUWHUFKDUJHUWRÀDPPDEOHRUKDUVKFKHPLFDOVRUYDSRUV z
(QVXUHWKDWWKHUHLVQRZDWHUVRXUFHLQFOXGLQJGRZQVSRXWVVSULQNOHUVRUIDXFHWVDERYHRU
near the inverter charger. z
(QVXUHWKDWWKHEDWWHUEDQNLVSURSHUOFRQQHFWHGEHIRUHLQVWDOODWLRQ z
&KHFNWKHLQVWDOODWLRQHQYLURQPHQWRIWKHLQYHUWHUFKDUJHUUHJXODUODQGNHHSLWFOHDQWR
SUHYHQWWKHYHQWLODWLRQKROHVIURPEHLQJEORFNHGEGHEULVRUGXVW
07
Introduction
General Information
Introduction
Key Features
General Information
5(29:,QYHUWHU&KDUJHULVRXURJULGVPDUWOLYLQJFHQWHUWKDWUHYROXWLRQL]HV
FRPIRUWZKHQRXOLYHLQRXURJULGKRPHRU597KHLQYHUWHUFKDUJHUFDQLQYHUW’&WR$&
DQGGLUHFWOVXSSOSRZHUWRWKHORDGDQGFKDUJHWKHEDWWHUZKHQLWLVFRQQHFWHGWRWKHXWLOLW
power.
,QDGGWLRQLWVXSSRUWVGLHUHQWWSHVRIEDWWHULHVVXFKDV$0*HO6HDOHG/HDG$FLG6/$
DQG/L7KHLQYHUWHUFKDUJHUFDQVZLWFKSRZHUVXSSOIURPWKHXWLOLWSRZHUWREDWWHULHVZLWKLQ
PLOOLVHFRQGVHQVXULQJDVPRRWKPRGHVZLWFKZLWKRXWSRZHULQJRWKHORDG7KHOHYHUVWOH
FRQQHFWRUVPDNH$&,1287FRQQHFWLRQVVLPSODQGHDV7KHVLPSOLILQVWDOODWLRQDQG shorten
the installation time.
7KHLQYHUWHUFKDUJHUFDQEHFRQQHFWHGWR5HQRJGHYLFHVDQGVPDUWDFFHVVRULHVYLD%OXHWRRWK
RU59&:KHQWKHLQYHUWHUFKDUJHUZRUNVLQDVVRFLDWLRQZLWKWKH’&+RPHDSSRXZLOO have the
same system monitoring wherever you go on your smartphone. With advanced pure
sine wave technology, the inverter charger can protect and extend the life of
your electronic HTXLSPHQWDQGORDGV
Key Features
z Robust and sleek design
7KHKRXVLQJRIWKHLQYHUWHUFKDUJHULVPDGHRIVWHHOSODWHVWRHQVXUHLWV¿UPQHVVDQGDPRUH
IDVKLRQDEOHDSSHDUDQFH z Intuitive LCD and LED
<RXFDQYLHZDQGFKHFNWKHVWDWXVGLVSODHGRQWKH/&’DQG/(‘VDQGPRGLISDUDPHWHUVRI the
inverter charger according to the actual use. z High quality waveform with
little harmonic distortion
$GYDQFHG3XUH6LQH:DYHWHFKQRORJSURYLGHVKLJKTXDOLW$&SRZHUHTXLYDOHQWWRWKHJULG
power. The voltage increases and decreases in a smooth way with little
harmonic distortion. z Multi-stage Battery charging
8SWRWKUHHVWDJHEDWWHUFKDUJLQJLQFOXGLQJEXONERRVWDQGÀRDWDVZHOODVHTXDOL]DWLRQIRU
VHOHFWEDWWHUWSHV z &RQ¿JXUDEOHFKDUJLQJFXUUHQW
7KHPD[LPXPFKDUJLQJFXUUHQWRIWKHLQYHUWHUFKDUJHULV$DGMXVWDEOHDW$HDFKWLPH7KH
FKDUJLQJFXUUHQWFDQEHDMXVWHGWRVDWLVI\RXUGDLOXVH z Nine preset battery voltages
and custom options
7KHLQYHUWHUFKDUJHULVFRPSDWLEOHZLWKQLQHWSHVRIEDWWHULHVWRPHHWRXUQHHGVLQGDLOXVH
<RXFDQDOVRFXVWRPL]HWKHEDWWHUSDUDPHWHUVRIWKHLQYHUWHUFKDUJHU z Automatic
generator start
7KHLQYHUWHUFKDUJHULVHTXLSSHGZLWKDVHWRI12DQG1&GUFRQWDFWVZKLFKDUHXVHGWR connect
the generator with automatic start and stop function and automatically charge
the EDWWHUIDFLOLWDWLQJRXUGDLOXVH
Introduction
General Information Key Features
z 3HDNFRQYHUVLRQHFLHQF!
7KHSHDNFRQYHUVLRQHFLHQFLVPRUHWKDQGXULQJRSHUDWLRQZKLFKUHGXFHVWKHHQHUJ loss. z
Multiple electronic protections
7KHLQYHUWHUFKDUJHULVHTXLSHGZLWKXQGHUYROWDJHSURWHFWLRQRYHUYROWDJHSURWHFWLRQRYHUORDG
protection, overtemperature protection, and short circuit protection.
09
Package Contents
Package Contents
REGO 12V 3000W Inverter Charger 1
ON OFF
CHC AC / INV
FAULT
HBpleiegAfahoRsrveeNoIwrlNetaoaGgrdkeit,nhingeooinrndsetthrruistcotpiaorovndosuidccatr.risekfusl,ly
Pure Sine Wave Inverter Charger
%DWWHU7HPSHUDWXUH6HQVRU[
4XLFN*XLGH 1
REGO
Inverter Charger 12V 3000W
VERSION A0
ON OFF
CHC AC / INV
FAULT
HBpleiegAfahoRsrveeNoIwrlNetaoaGgrdkeit,nhingeooinrndsetthrruistcotpiaorovndosuidccatr.risekfusl,ly
Pure Sine Wave Inverter Charger
QUICK GUIDE
Wired Remote Control x 1
ON
ERR
RMS-P2
5-1HWZRUN&DEOHP[
10
Optional Accessories
Optional Accessories
NOTE z <RXFDQEXRSWLRQDODFFHVVRULHVIURPrenogy.com.
‘&)XVH$ 7KH’&IXVHSURWHFWVWKHLQYHUWHUFKDUJHUZLUHVDQGEDWWHULHV from overcurrent.
)XVH&DEOH$:* 7KHFDEOHLVLQWHJUDWHGZLWKFRSSHUULQJVDWERWKHQGVHQDEOLQJ
WKHLQYHUWHUFKDUJHUWREHFRQQHFWHGZLWKDQH[WHUQDOIXVH
11
Product Overview
External View
Product Overview
Internal View
External View
1
2
3
4
5
6
6
ON OFF
CHC AC / INV
FAULT
HBpleiegAfahoRsrveeNoIwrlNetaoaGgrdkeit,nhingeooinrndsetthrruistcotpiaorovndosuidccatr.risekfusl,ly
Pure Sine Wave Inverter Charger
78
9
10
11
No.
Part
1 5HPRWH $FFHVVRU&DEOH(QWU
2 $&2XWSXW&DEOH*URPPHW
3 $&,QSXW&DEOH*URPPHW
4 Main Power Switch
5 /&’ %XWWRQ3DQHO
6 Mounting Holes
No.
Part
7 ‘&1HJDWLYH%DWWHU&DEOH(QWU
8 ‘&&DEOH3ODWH
9 ‘&3RVLWLYH%DWWHU&DEOH(QWU
10 Chassis Ground Lug
11 Top Plate
12
Product Overview
External View Internal View
Internal View
12
13 14 15
16
ON OFF
AC/INV CHC FAULT Pure Sine Wave Inverter Charger
REMOTE CAN
DRY CONTACT
NC C NO
BTS
LN OUTPUT
NL INPUT
WARNING
HpBlieegfahosrveeorwlteaoagrdkei,tnihngeooirnndsetthrruitscotpiaorvonodsiudccarti.rsekfsu,lly
CHAPRRGOETRECINTPUT
INVERPRTEORTEOCUTTPUT
ATIVE
GITIVE
17 18
19
20
21
22
No.
Part
12 Wired Remote Port (REMOTE)
13 ‘U&RQWDFW5HOD7HUPLQDO%ORFN
14 $&2XWSXW/HYHU7HUPLQDO%ORFN
15 $&,QSXW/HYHU7HUPLQDO%ORFN
16 ,QSXW&LUFXLW%UHDNHU
17 &RPPXQLFDWLRQ3RUW&$1%XV
No.
Part
18 %DWWHU7HPSHUDWXUH6HQVRU%763RUW
19 ‘&1HJDWLYH%DWWHU7HUPLQDO
20 Fan
21 ‘&3RVLWLYH%DWWHU7HUPLQDO
22 2XWSXW&LUFXLW%UHDNHU
13
:LULQJ’LDJUDP
:LULQJ’LDJUDP
Live wire (AC) Neutral wire (AC) Positive (DC) Negative (DC) Ground
Temperature sensor Remote control
AC Loads
Shore Power or Generator
AC Load Center (120V Single Phase, 30A Max.) (120V Single Phase, 40A Max.)
ON OFF
AC/INV CHC FAULT Pure Sine Wave Inverter Charger
REMOTE CAN
DRY CONTACT
NC C NO
BTS
LN OUTPUT
NL INPUT
WARNING
HpBlieegfahosrveeorwlteaoagrdkei,tnihngeooirnndsetthrruitscotpiaorvonodsiudccarti.rsekfsu,lly
CHAPRRGOETRECINTPUT
INVERPRTEORTEOCUTTPUT
ATIVE
GITIVE
DC Fuse (400A)
ON
ERR
RMS-P2
Wired Remote Control
Battery System (12V)
Chassis Ground Lug
NOTE
z ‘RQRWXVHWKHWHPSHUDWXUHVHQVRURQD/L)H32/)3EDWWHUZKLFKFRPHVZLWKD%DWWHU
0DQDJHPHQW6VWHP%06
14
Recommended Cable Sizing
Recommended Cable Sizing
Cable AC Output
AC Intput
&DEOH/HQJWKIWP 0 ft to 10 ft (0 m to 3 m) 11 ft to 20 ft (3 m to 6 m) 21 ft to 30 ft (6 m to 9 m) 0 ft to 10 ft (0 m to 3 m) 11 ft to 20 ft (3 m to 6 m) 21 ft to 30 ft (6 m to 9 m)
Recommended Cable Size 8 AWG 6 AWG 6 AWG 8 AWG
6 AWG to 8 AWG 6 AWG
NOTE
z 7KHFDEOHVSHFL¿FDWLRQVOLVWHGDERYHDFFRXQWIRUFULWLFDOOHVVWKDQYROWDJHGURSDQGPD
QRWDFFRXQWIRUDOOFRQ¿JXUDWLRQV
15
Components & Tools
Components & Tools
CAUTION z
7KHDGDSWHUFDEOHXVHGLQWKLVPDQXDOFDQEHPDGHE\RXUVHOIRUSXUFKDVHGIURPrenogy.
comEVHDUFKLQJQDPHVLQ5HFRPPHQGHG&RPSRQHQWV Recommended Components
%DWWHU6FHQDULR$5(2%DWWHU.LW
5(29$K/LWKLXP,URQ3KRVSKDWH%DWWHU
6VWHP&RPELQHU%R[$FFHVVRU6HW 5(*23RUWV$6VWHP&RPELQHU%R[
3RVLWLYH1HJDWLYH%XVEDUV$FFHVVRU6HW 3RVLWLYH1HJDWLYH%XVEDUV
Inverter DC-DC Charger
%DWWHU$GDSWHU&DEOH$:* (Anderson 350 Connector to
5LQJ7HUPLQDO$GDSWHU&DEOHRU 5LQJ7HUPLQDO$GDSWHU&DEOH
%DWWHU,QYHUWHU&DEOH$:* 5LQJ7HUPLQDO$GDSWHU&DEOH
16
Components & Tools
%DWWHU6FHQDULR%1RUPDO%DWWHU.LW 1RUPDO%DWWHUZLWK%ROWV
- –
%DWWHU,QYHUWHU&DEOH$:* 5LQJ7HUPLQDO$GDSWHU&DEOH
Required Tools Wrench (10 mm)
Wrench (14 mm)
Measuring Tape
Insulation Tape
14mm
10mm
10mm
14mm
14mm
10mm
3 4 5 6
Phillips Screwdriver Slotted Screwdriver
(6 mm)
(6 mm)
6RFNHW:UHQFK (12 mm)
Wire stripper
Grounding (6 AWG to 8 AWG)
%DUH:LUH
AC Output x 3
17
Components & Tools
NOTE z 7KH$&2XWSXW&DEOH*URPPHWKDVDQLQQHUGLDPHWHURIPP3URSHUOVHOHFWWKH$&
FDEOHVL]HDQGHQVXUHLWFDQUXQWKURXJKWKHJURPPHW z
7KH’&3RVLWLEH1HJDWLYH7HUPLQDOVXVH06WXGV6HOHFWWKHDSSURSULDWHULQJWHUPLQDO z Read
5HFRPPHQGHG&DEOH6L]LQJ LQWKLVPDQXDODQGVHOHFWWKHDSSURSULDWHFDEOHV
according to actual use.
18
Inspection
Inspecting Inverter Charger
Inspection
Environment Placement
Checking Battery
ON OFF
CHC AC / INV
FAULT
HBpleiegAfahoRsrveeNoIwrlNetaoaGgrdkeit,nhingeooinrndsetthrruistcotpiaorovndosuidccatr.risekfus,lly
Pure Sine Wave Inverter Charger
Inspecting Inverter Charger
1. ,QVSHFWWKHLQYHUWHUFKDUJHUIRUDQYLVLEOHGDPDJHLQFOXGLQJ
FUDFNVGHQWVGHIRUPDWLRQDQGRWKHUYLVLEOHDEQRUPDOLWLHV
$OOFRQQHFWRUFRQWDFWVVKDOOEHFOHDQGUDQGIUHHRIGLUW and corrosion.
WARNING z ‘RQRWXVHWKHLQYHUWHUFKDUJHULILWKDVDQYLVLEOHGDPDJH
Environment
,QVWDOOWKHLQYHUWHUFKDUJHURQDÀDWVXUIDFHLQGRRUVSURWHFWHGIURPGLUHFWVXQOLJKWKLJK
WHPSHUDWXUHDQGZDWHU0DNHVXUHWKHUHLVJRRGYHQWLODWLRQ
0DNHVXUHWKDWWKHLQYHUWHUFKDUJHULVLQVWDOOHGLQDSODFHDWDPELHQWWHPSHUDWXUHIURP°F to
104°F or -20°C to 40°CDQGUHODWLYHKXPLGLWEHWZHHQDQGQRFRQGHQVDWLRQ
NOTE z
,QVWDOOWKHLQYHUWHUFKDUJHUDVFORVHWRWKHEDWWHUDVSRVVLEOHWRDYRLGYROWDJHGURSVGXHWR
ORQJFDEOHV
WARNING z
5LVNRIH[SORVLRQ1HYHULQVWDOOWKHLQYHUWHUFKDUJHULQDVHDOHGHQFORVXUHZLWKÀRRGHG
EDWWHULHV’RQRWLQVWDOOLWLQDFRQ¿QHGDUHDZKHUHEDWWHUJDVHVFDQDFFXPXODWH
Inspection
Inspecting Inverter Charger Environment Placement Checking Battery
Placement
7KHLQYHUWHUFKDUJHUFDQEH¿[HGYHUWLFDOOWHUPLQDOVIDFLQJGRZQWRDZDOORUKRUL]RQWDOOWR
WKHÀRRU
ON OFF
AC / INV CHC FAULT
ON OFF
CHC AC / INV
FAULT
HBpleiegAfahoRsrveeNoIwrlNetaoaGgrdkeit,nhingeooinrndsetthrruistcotpiaorovndosuidccatr.risekfus,lly
Pure Sine Wave Inverter Charger
Pure Sine Wave Inverter Charger 3000W
CHC AC / INV
FAULT
ON OFF
Pure Sine Wa3v0e0I0nW verter Charger
ON OFF
AC / INV CHC FAULT
ON
OFF
AC / INV CHC
FAULT
Pure
Sine
Wave Inverter 3000W
Charger
Pure Sine Wave Inverter Charger 3000W
Pure Sine Wave Inverter Charger 3000W
AC / INV CHC FAULT
OFF
ON
PP LQ
PP LQ
ON OFF
CHC AC / INV
FAULT
HBpleiegAfahoRsrveeNoIwrlNetaoaGgrdkeit,nhingeooinrndsetthrruistcotpiaorovndosuidccatr.risekfus,lly
PP LQ
Pure Sine Wave Inverter Charger
PP LQ
1. (QVXUHHQRXJKVSDFHWRDYRLGWDQJOHVDQGNLQNVRIFDEOHV Allow at least 10 inches
of clearance at the fan and at least
LQFKHVDURXQGHDFKVLGH,WLVEHWWHUWRKDYHDODUJHU
YHQWLODWLRQJDS’RQRWREVWUXFWWKHIDQRSHQLQJV
20
Inspection
Inspecting Inverter Charger Environment Placement
Checking Battery
ON OFF
CHC AC / INV
FAULT
HBpleiegAfahoRsrveeNoIwrlNetaoaGgrdkeit,nhingeooinrndsetthrruistcotpiaorovndosuidccatr.risekfus,lly
Pure Sine Wave Inverter Charger
2. Measure the length of the
DGDSWHUFDEOHWRPDNH VXUHLWFDQEHFRQQHFWHG to the inverter charger.
NOTE
z ,IWKHDGDSWHUFDEOHLVQRWORQJHQRXJKUHVHOHFWWKHLQVWDOODWLRQVLWH
ON OFF
ON OFF
CHC AC / INV
FAULT
Pure Sine Wave Inverter Charger
3. After the installation site LVGHWHUPLQHGURFNWKH main switch of the inverter charger to the “OFF” SRVLWLRQDQGNHHSLWXQWLO the inverter charger is UHDGWREHSRZHUHGRQ
HBpleiegAfahoRsrveeNoIwrlNetaoaGgrdkeit,nhingeooinrndsetthrruistcotpiaorovndosuidccatr.risekfusl,ly
- –
Checking Battery
1. ,QVSHFWWKHEDWWHUIRUDQYLVLEOHGDPDJHLQFOXGLQJFUDFNV
GHQWVGHIRUPDWLRQDQGRWKHUYLVLEOHDEQRUPDOLWLHV$OO
FRQQHFWRUFRQWDFWVVKDOOEHFOHDQGUDQGIUHHRIGLUWDQG corrosion.
INFO z 5HDGWKHXVHUPDQXDORIWKHEDWWHUFDUHIXOOEHIRUHLQVWDOODWLRQ
21
Inspection
Inspecting Inverter Charger Environment Placement Checking Battery
NOTE
z 0DNHVXUHWKHEDWWHULVZRUNLQJQRUPDOO z
%DWWHUWSHVVXSSRUWHGEWKHLQYHUWHUFKDUJHU$0HO6/$2SHQ/HDG$FLG)RRGHG
Calcium/De-sulphation/Li. z
7DNHFDUHWRXVHDKLJKFDSDFLWOHDGDFLGEDWWHU%HVXUHWRZHDUSURWHFWLYHJRJJOHV,I
FDUHOHVVOJHWWLQJHOHFWUROWHLQRXUHHVÀXVKRXUHHVZLWKFOHDQZDWHULPPHGLDWHO
CAUTION
z Comply with local, state, and federal laws and regulations and use recycling
channels as UHTXLUHGZKHQGLVSRVLQJRIXQZDQWHGEDWWHULHV
WARNING
z ‘RQRWXVHWKHEDWWHULILWKDVDQYLVLEOHGDPDJH z
‘RQRWWRXFKWKHH[SRVHGHOHFWUROWHRUSRZGHULIWKHEDWWHUKRXVLQJLVGDPDJHG z
:KHQEHLQJFKDUJHGWKHEDWWHUPDJLYHRH[SORVLYHJDV0DNHVXUHWKHUHLVJRRG
ventilation.
Battery or Battery Bank System Voltage
%DWWHURU%DWWHU%DQN6VWHP9ROWDJH 6VWHP9ROWDJH8
Batteries in Series
Batteries in Parallel
System Voltage U: U18283 System Voltage U: U1 82 83
2. &RPELQHEDWWHULHVLQ parallel or in series as needed. This inverter charger supports 12V EDWWHULHV5HDGWKHXVHU PDQXDOIRUEDWWHUYROWDJH parameters, and calculate WKHEDWWHURUEDWWHUEDQN system voltage according to the formula to ensure that it is 12V.
NOTE z ,QWKHIRUPXOD8UHSUHVHQWVWKHEDWWHUYROWDJHDQGRUUHSUHVHQWVWKHEDWWHUQXPEHU
respectively.
WARNING z ‘RQRWXVHWKHLQYHUWHUFKDUJHULIWKHEDWWHUEDWWHUEDQNVVWHPYROWDJHH[FHHGV9
Doing so will cause damage to the inverter charger.
22
Preparation
Mounting
Preparation
Removing the Plate
Cautions
Mounting
Recommended Accessories Self-tapping Screws (M8 or M6)
NOTE
z Choose proper self-tapping screws to adapt to the installation site.
z 0DNHVXUHWKHLQYHUWHUFKDUJHULV¿UPOPRXQWHGRQWKHLQVWDOODWLRQVLWHWRSUHYHQWLWIURP
VOLGLQJRUIDOOLQJR
M6
ON OFF
CHC AC / INV
FAULT
Pure Sine Wave Inverter Charger
M8
ON OFF
CHC AC / INV
FAULT
Pure Sine Wave Inverter Charger
Align the inverter charger with the mounting position to ¿[LWZLWKVHOIWDSSLQJVFUHZV through the mounting holes.
HBpleiegAfahoRsrveeNoIwrlNetaoaGgrdkeit,nhingeooinrndsetthrruistcotpiaorovndosuidccatr.risekfusl,ly
HBpleiegAfahoRsrveeNoIwrlNetaoaGgrdkeit,nhingeooinrndsetthrruistcotpiaorovndosuidccatr.risekfusl,ly
ON OFF
CHC AC / INV
FAULT
HBpleiegAfahoRsrveeNoIwrlNetaoaGgrdkeit,nhingeooinrndsetthrruistcotpiaorovndosuidccatr.risekfusl,ly
Removing the Plate
REMOTE
CHC AC / INV
FAULT
L OUTPUNT
ON OFF
N INPUTL
HWBpleiegAfahoRsrveeNowrIleNtaoaGgrdkeit,nhingeooinrndsetthrruistcotpiaorovndosuidccatr.risekfusl,ly
HWBpleiegAfahoRsrveeNowrIleNtaoaGgrdkeit,nhingeooinrndsetthrruistcotpiaorovndosuidccatr.risekfusl,ly CHAPRRCOETR W
- Pure Sine Wave Inverter Charger
Turn the two upper panel VFUHZVFRXQWHUFORFNZLVH EKDQGRUD3KLOOLSV screwdriver,
and remove
the Top Plate.
23
Preparation
Mounting Removing the Plate Cautions
REMOTE
L OUTPUNT
ON OFF
N INPUTL
HWBpleiegAfahoRsrveeNowrIleNtaoaGgrdkeit,nhingeooinrndsetthrruistcotpiaorovndosuidccatr.risekfusl,ly
HWBpleiegAfahoRsrveeNowrIleNtaoaGgrdkeit,nhingeooinrndsetthrruistcotpiaorovndosuidccatr.risekfusl,ly CHAPRRCOETR W
REMOTE
CODNRTYACT
NC
CAN
C
NO
NEGATIVE
CHC AC / INV
FAULT
L OUTPUNT
ON OFF
N INPUTL
HWBpleiegAfahoRsrveeNowrIleNtaoaGgrdkeit,nhingeooinrndsetthrruistcotpiaorovndosuidccatr.risekfusl,ly
HWBpleiegAfahoRsrveeNowrIleNtaoaGgrdkeit,nhingeooinrndsetthrruistcotpiaorovndosuidccatr.risekfusl,ly CHAPRRCOETR W
2. Turn the two screws on the lower panel FRXQWHUFORFNZLVHEKDQG or a Phillips screwdriver, DQGUHPRYHWKH’&&DEOH Plate.
Cautions
NOTE
z $OOZLULQJVKRXOGEHGRQHETXDOL¿HGSHUVRQQHOWRHQVXUHFRPSOLDQFHZLWKDOODSSOLFDEOH
installation code and regulations.
z :HDUSURSHUSURWHFWLYHHTXLSPHQWDQGXVHLQVXODWHGWRROVGXULQJLQVWDOODWLRQ z Ensure
that all ring terminals are securely connected. z
0DNHVXUHDOOFDEOHVKDYHDVPRRWKEHQGUDGLXVDQGQRNLQNVDUHSUHVHQW z
&RORUFRGHDQGODEHODOO$&&DEOHVFRPLQJWRIURPWKHLQYHUWHUFKDUJHU8VHFRORUHG
HOHFWULFDOWDSHRUKHDWVKULQNWXELQJ
WARNING z
5LVNRIHOHFWULFVKRFN(QVXUHWKDWDOOSRZHUVRXUFHVDUHGLVFRQQHFWHGEHIRUHLQVWDOODWLRQ
z 0DNHVXUHWKDWDOODGDSWHUFDEOHVDUHQRWFRQQHFWHGWRDQGHYLFHEHIRUHFRQQHFWLRQ,IWKH
DUHFRQQHFWHGPDNHVXUHWKDWDOOSRZHUGHYLFHVDUHSRZHUHGR z
,GHQWLIWKHSRODULWLHVSRVLWLYHDQGQHJDWLYHRQWKHFDEOHVXVHGIRUEDWWHULHV$UHYHUVH
polarity contact will damage the inverter charger and void the warranty. z Do
not connect the AC Load Output to an AC Power Source such as generator or
shore
power. Otherwise, severe damage may occur.
24
*URXQG&DEOH:LULQJ
*URXQG&DEOH:LULQJ
REMOTE
CODNRTYACT
NC
CAN
C
NO
NEGATIVE
CHC AC / INV
FAULT
L OUTPUNT
ON OFF
N INPUTL
HWBpleiegAfahoRsrveeNowrIleNtaoaGgrdkeit,nhingeooinrndsetthrruistcotpiaorovndosuidccatr.risekfusl,ly
HWBpleiegAfahoRsrveeNowrIleNtaoaGgrdkeit,nhingeooinrndsetthrruistcotpiaorovndosuidccatr.risekfusl,ly CHAPRRCOETR W
Close
1. 7XUQWKHFDEOHUHWDLQHUVFUHZVIRUWKH&KDVVLV*URXQG/XJ FRXQWHUFORFNZLVHZLWKDVORWWHGVFUHZGULYHUWRHQVXUHWKDW WKHFDEOHUHWDLQHULVRSHQ
Open
2. ,QVHUWRQHHQGRIWKHEDUHZLUHLQWRWKHZLULQJKROHRIWKH Chassis Ground Lug.
NOTE
z 6WULSVRPHLQVXODWLRQRWKHJURXQGLQJFDEOHEXVLQJDZLUHVWULSSHUDFFRUGLQJWRWKHGHSWK
of the wiring hole. Bpleefaosree wreoardkitnhgeoinnstthruisctpiorondsuccat.refully
3. 7LJKWHQWKHFDEOHUHWDLQHUVFUHZVIRUWKH&KDVVLV*URXQG
/XJFORFNZLVHZLWKDVORWWHGVFUHZGULYHUWRIDVWHQWKHFDEOH
NOTE z 7KHWRUTXHRIWKHFDEOHUHWDLQHUVFUHZLV1P’RQRWRYHUWLJKWHQLWWRSUHYHQWGDPDJH
25
*URXQG&DEOH:LULQJ
REMOTE
CODNRTYACT
NC
CAN
C
NO
NEGATIVE
CHC AC / INV
FAULT
L OUTPUNT
ON OFF
N INPUTL
HWBpleiegAfahoRsrveeNowrIleNtaoaGgrdkeit,nhingeooinrndsetthrruistcotpiaorovndosuidccatr.risekfusl,ly
HWBpleiegAfahoRsrveeNowrIleNtaoaGgrdkeit,nhingeooinrndsetthrruistcotpiaorovndosuidccatr.risekfus,lly CHAPRRCOETR W
Pure Sine Wave Inverter Charger
4. Connect the other end RIWKHEDUHFDEOHWRWKH Chassis Ground Lug of the RV.
INFO
z When connecting the inverter charger to the chassis ground lug of your RV,
consult the
59VXSSOLHUWRFRQ¿UPWKHORFDWLRQRIWKHFKDVVLVJURXQGOXJ$FRQQHFWLRQWHUPLQDOFDQEH
installed if needed.
26
5HPRWH&RQWURO:LULQJ
5HPRWH&RQWURO:LULQJ
You may choose to use the wired remote control of the inverter charger.
REMOTE
CODNRTYACT
NC
CAN
C
NO
NEGATIVE
L OUTPUNT
ON OFF
N INPUTL
AC / INV
REMOTE FAULT
CHC
HWBpleiegAfahoRsrveeNowrIleNtaoaGgrdkeit,nhingeooinrndsetthrruistcotpiaorovndosuidccatr.risekfusl,ly
HWBpleiegAfahoRsrveeNowrIleNtaoaGgrdkeit,nhingeooinrndsetthrruistcotpiaorovndosuidccatr.risekfusl,ly CHAPRRCOETR W
Pure Sine Wave Inverter Charger
1. Run one end of the LQFOXGHG5-FDEOH through the Remote & $FFHVVRU&DEOH(QWU
BefploerHae IN VE
BefploerHiaesgwehWorvAreokliRatndaNgItghNeo,einGintnhoisrtsrdupercrtoitdo
CHG
AC/INV
ON OFF
REMOTE
CODNRTYACT NC C NO
CAN BTS
2. Connect the connector to the Wired Remote Port (REMOTE).
C ONDTR AY C T NO CNC
ON AC/INV CHG FAULT
OFF
Wired Remote Port (REMOTE)
ON
ERR
RMS-P2
Wired Remote Control
3. Connect the connector on the other end of the RJ11 FDEOHWRWKH:LUHG5HPRWH Control.
27
7HPSHUDWXUH6HQVRU:LULQJ
7HPSHUDWXUH6HQVRU:LULQJ
7KHWHPSHUDWXUHVHQVRUPHDVXUHVWKHWHPSHUDWXUHRIWKHEDWWHUDQGSURYLGHVWKHLQYHUWHU FKDUJHUZLWKDFKDUJHYROWDJHFDOLEUDWLRQPHFKDQLVPWRHQVXUHWKDWWKHLQYHUWHUFKDUJHUFDQ SURSHUOFKDUJHWKHEDWWHUZLWKLQWKHRSHUDWLQJWHPSHUDWXUHIURP°F to 140°F or -20°C to 60°C.
NOTE
z ‘RQRWXVHWKHWHPSHUDWXUHVHQVRURQD/L)H32/)3EDWWHUZKLFKFRPHVZLWKDEDWWHU
PDQDJHPHQWVVWHP%06
z 7KHUHLVQRUHTXLUHPHQWRQSRODULWIRUWHPSHUDWXUHVHQVRUFDEOHV
REMOTE
CODNRTYACT
NC
CAN
C
NO
NEGATIVE
CHC AC / INV
FAULT
L OUTPUNT
ON OFF
N INPUTL
HWBpleiegAfahoRsrveeNowrIleNtaoaGgrdkeit,nhingeooinrndsetthrruistcotpiaorovndosuidccatr.risekfusl,ly
HWBpleiegAfahoRsrveeNowrIleNtaoaGgrdkeit,nhingeooinrndsetthrruistcotpiaorovndosuidccatr.risekfusl,ly CHAPRRCOETR W
PureSineW 1. 5XQWKHEDUHWHUPLQDORI the temperature sensor
through the Remote &
REMOTE
$FFHVVRU&DEOH(QWU
2. 7XUQWKHFDEOHUHWDLQHUVFUHZVIRUZLUHKDUQHVVFRQQHFWRU
FRXQWHUFORFNZLVHZLWKDVORWWHGVFUHZGULYHUWRHQVXUHWKDW WKHFDEOHUHWDLQHULVRSHQ
Close
Open
3. ,QVHUWWKHEDUHWHUPLQDORI the temperature sensor into the harness connector
and tighten it with a slotted VFUHZGULYHUEWXUQLQJWKH FDEOHUHWDLQHUVFUHZIRU
wire harness connector FORFNZLVH
BefplIoerH Niaesg VehwW E PorvAr Re RokliRa Tt OndaN C EIgt Tg H RheNo E, Pei AnG Cin O Rt Rn Th Uois O Grts Tr Td Eup Pe Ercr Rt Uiot CIdo T T Nnuasc Ptv.co Uiard Terfisullkys, BefploerHiaesgweh WorvAreokliRatndNaIgtghNeo,einGintnhoisrtsrdupercrtoitdounacstv.coiarderfisullkys,
ON OFF
FAULT
CHG
AC/INV
ON OFF
C ONDTR AY C T NO CNC
NOTE z 6WULSVRPHLQVXODWLRQRWKHJURXQGLQJFDEOHZLWKDZLUHVWULSSHU
28
7HPSHUDWXUH6HQVRU:LULQJ
z ‘RQRWRYHUWLJKWHQWKHFDEOHUHWDLQHUVFUHZV2WKHUZLVHLWZLOOOHDGWRVWULSSHGVFUHZVRU VFUHZEHQGLQJ
AC/INV
CAN BTS
4. 3OXJWKHKDUQHVVFRQQHFWRULQWRWKH%763RUWRIWKHLQYHUWHU charger.
ON OFF
C ONDTR AY C T NO CNC BefploerHiaesgwehWorvAreokliRatndaNIgtghNeo,einGintnhoiss
- –
5. 3ODFHWKHWHPSHUDWXUHVHQVRUQHDUWKHEDWWHUDQG¿[LWZLWK DFDEOHWLHRULQVXODWLRQWDSHLIQHFHVVDU
29
FAULT
CHG
AC/INV
ON OFF
BefploIerHia NesgehwWorvAreokliRatndaNgg VE PR RT O C EH RAR O
BefploerHiaesgwehWorvAreokliRatndaNIgtghNeo,einGintnhoisrtsrdupercrtoitdounacstv.coiarderfisu
%DWWHU:LULQJ
‘HYLFHVLGH:LULQJ
%DWWHU:LULQJ
%DWWHUVLGH:LULQJ
‘HYLFHVLGH:LULQJ
FAULT
CHG
AC/INV
ON OFF
BefploIerHia NesgehwWorvAreokliRatndaNgg VE PR RT O C EH
BefploerHiaesgwehWorvAreokliRatndaNIgtghNeo,einGintnhoisrtsrdupercrtoitdounacstv.coiarderfisu
1. Remove the retaining
nut of the DC Negative
%DWWHU7HUPLQDOEWXUQLQJ LWFRXQWHUFORFNZLVHZLWKD VRFNHWZUHQFKDQGWKHQ
UHPRYHWKHJDVNHW
C ONDTR AY C T NO CNC
C ONDTR AY C T NO CNC
2. Remove the retaining nut
RIWKH’&3RVLWLYH%DWWHU 7HUPLQDOEWXUQLQJLW FRXQWHUFORFNZLVHZLWKD
VRFNHWZUHQFKDQGWKHQ UHPRYHWKHJDVNHW
BefploIerHia NesgVehwWEor PvAre Rok RliRat Tnd OaN CIg Etg Th HeNo R, Eei Pn
AGin Ct O Rn Rh Tois Ur Ot Gsrd T Tu Epe Prcr Et Riot U CIdoT Tnu Nasctv P.coi
UardTerfisullkys,
BefploerHiaesgwehWorvAreokliRatndaNIgtghNeo,einGintnhoisrtsrdupercrtoitdounacstv.coiarderfisullkys,
BefploIerHiae NsgVehwWEor PvAreo Rk RliRat Tnd OaN CIg Etg Th HeNo R, Eei Pn
AGin Ct O Rn Rh Tois Ur Ot Gsrd T Tu Epe Prrc Et Riot U CIdoT Tnu Nasctv P.coi
UardTerfisullkys,
BefploerHiaesgwehWorvAreokliRatndaNIgtghNeo,einGintnhoisrtsrdupercrtoitdounacstv.coiarderfisullkys,
CHG
CHG
AC/INV
AC/INV
ON OFF
ON OFF
REGO Battery Kit Normal Battery Kit
REMOTE
CODNRTYACT
NC
CAN
C
NO
NEGATIVE
CHC AC / INV
FAULT
L OUTPUNT
ON OFF
N INPUTL
HWBpleiegAfahoRsrveeNowrIleNtaoaGgrdkeit,nhingeooinrndsetthrruistcotpiaorovndosuidccatr.risekfusl,ly
HWBpleiegAfahoRsrveeNowrIleNtaoaGgrdkeit,nhingeooinrndsetthrruistcotpiaorovndosuidccatr.risekfusl,ly CHAPRRCOETR W
3. Insert the positive ring
WHUPLQDORIWKHEDWWHU DGDSWHUFDEOHWKURXJKWKH ‘&3RVLWLYH%DWWHU&DEOH Entry, and
the negative
ring terminal through
WKH’&1HJDWLYH%DWWHU &DEOH(QWU
NOTE z 6HOHFWDSSURSULDWHEDWWHUDGDSWHUFDEOHVEDVHGRQRXUQHHGV
30
CHG
FAUL
%DWWHU:LULQJ
‘HYLFHVLGH:LULQJ %DWWHUVLGH:LULQJ
4. Connect the negative ring terminal to the DC Negative %DWWHU7HUPLQDO
5. ,QVWDOOWKHJDVNHWDQGWKH retaining nut, and tighten WKHQXWFORFNZLVHZLWKD
VRFNHWZUHQFK
NOTE z
7KHUHWDLQLQJQXWWRUTXHRIWKH’&1HJDWLYH%DWWHU7HUPLQDOLV1P’RQRWRYHUWLJKWHQLW
to prevent damage. 6. &RQQHFWWKHSRVLWLYHULQJWHUPLQDOWRWKH’&3RVLWLYH%DWWHU
&DEOH(QWU
31
AC/INV
BepfoleIHrN aeigsV WwehE P oArvrR eR oRkalT iO tnNdaC E ggT ItH NR heoE P e,GA
niC O nR iR tnhT U oO sG irstT drT E upeP E cR rrU otC itodIT T N nuascP
vtc.oU aidT rerfis
C ONDTR AY C T NO CNC
ON OFF
BepfoleHraeigsh
BepfoleIHrN aeigsV WwehE P oArvR reR oRkaT liO tnNdaC E gT gItH NR heoE P eA ,GniC O nR iR tnT hU oO sG irstT dT rE upeP E cR rrU otC itodIT T N nuascP vtc.oUaidT rerfiuskllys,
BepfoleHraeigsWwehoArvreoRkalitnNdaggItNheoeG,ninitnhosirstdrupecrrotitdounacsvt.coaidrerfiuskllys,
FAULT
C ONDTR AY C T NO CNC
ON OFF
BepfoleHraeigsWwehoArvreoRkalitnNda IN VE PR RT O C EH RARG O
BepfoleHraeigsWwehoArvreoRkalitnNdaggItNheoeG,ninitnhosirstdrupecrrotitdounacsvt.coaidrerf
AC/INV
CHG
C ONDTR AY C T NO CNC
ON OFF
AC/INV
C ONDTR AY C T NO CNC
BepfoleHraeigsWwehoArvreoRkalitnNda IN VE PR RT O C EHARG
BepfoleHraeigsWwehoArvreoRkalitnNdaggItNheoeG,ninitnhosirstdrupecrrotitdounacsvt.coaidrerf
FAULT
CHG
AC/INV
C ONDTR AY C T NO CNC
ON OFF
BepfoleHraeigsWwehoArvreoRkalitnNda IN VE PR RT O C EH
BepfoleHraeigsWwehoArvreoRkalitnNdaggItNheoeG,ninitnhosirstdrupecrrotitdounacsvt.coaidrerf
CHG
FAULT
FAUL
%DWWHU:LULQJ
‘HYLFHVLGH:LULQJ %DWWHUVLGH:LULQJ
7. ,QVWDOOWKHJDVNHWDQG retaining nut, and tighten
WKHQXWFORFNZLVH ZLWKDVRFNHWZUHQFK
BefploIerHia NesgVehwWEor PvAreo Rk RliRat Tnd OaN CIg Etg Th HeNo R, Eei Pn AGin Ct O Rn Rh Tois Ur Ot Gsrd T Tu Epe Prrc Et Riot U CIdoT Tnu Nasctv P.coi UardTerfisullkys, BefploerHiaesgwehWorvAreokliRatndaNIgtghNeo,einGintnhoisrtsrdupercrtoitdounacstv.coiarderfisullkys,
BefploIerHiae NsgVehwWEor PvAreo Rk RliRat Tnd OaN CIg Etg Th HeNo R, Eei Pn AGin Ct O Rn Rh Tois Ur Ot Gsrd T Tu Epe Prrc Et Riot U CIdoT Tnu Nasctv P.coi UardTerfisullkys, BefploerHiaesgwehWorvAreokliRatndaNIgtghNeo,einGintnhoisrtsrdupercrtoitdounacstv.coiarderfisullkys,
FAUL
CHG
CHG
AC/INV
AC/INV
ON OFF
ON OFF
NO CNC
NO CNC
NOTE z
7KHUHWDLQLQJQXWWRUTXHRIWKH’&3RVLWLYH%DWWHU7HUPLQDOLV1P’RQRWRYHUWLJKWHQLW
to prevent damage.
%DWWHUVLGH:LULQJ
NOTE z
,GHQWLIWKHSRODULWLHVSRVLWLYHDQGQHJDWLYHRQWKHFDEOHVXVHGIRUWKHEDWWHULHV$UHYHUVH
polarity contact may damage the inverter charger. z Ensure that the Anderson
connectors are fully seated and/or the ring terminals are securely
connected.
WARNING z
‘RQRWWRXFKWKHSRVLWLYHDQGQHJDWLYHWHUPLQDOVRIWKHEDWWHUGLUHFWOZLWKRXUKDQGVDW
the same time. z
‘RQRWDOORZWKHSRVLWLYHDQGQHJDWLYHWHUPLQDOVRIWKHEDWWHUWRFRQWDFWZLWKHDFK
other.
32
%DWWHU:LULQJ
‘HYLFHVLGH:LULQJ %DWWHUVLGH:LULQJ
Battery Scenario A: REGO Battery Kit
INFO z 5HDGWKH5(*23RUWV$6VWHP&RPELQHU%R[8VHU0DQXDOFDUHIXOOEHIRUH
connection. 8VLQJ%DWWHU$GDSWHU&DEOH$QGHUVRQ&RQQHFWRUWR5LQJ7HUPLQDO$GDSWHU
&DEOH
REMOTE
CODNRTYACT
NC
CAN
C
NO
NEGATIVE
CHC AC / INV
FAULT
L OUTPUNT
ON OFF
N INPUTL
HWBpleiegAfahoRsrveeNowrIleNtaoaGgrdkeit,nhingeooinrndsetthrruistcotpiaorovndosuidccatr.risekfusl,ly
HWBpleiegAfahoRsrveeNowrIleNtaoaGgrdkeit,nhingeooinrndsetthrruistcotpiaorovndosuidccatr.risekfusl,ly CHAPRRCOETR W
Pure Sine Wave Inverter Charger
1. &RQQHFWWKH$QGHUVRQFRQQHFWRURIWKHEDWWHUDGDSWHUFDEOHWRWKH6VWHP&RPELQHU %R[
NOTE
z :KHQFRQQHFWLQJWKHFRPELQHUER[WRWKHLQYHUWHUFKDUJHUYLDWKHVVWHPKXERI$QGHUVRQ
connector, install a 400A NH fuse in the top disconnection switch.
8VLQJ%DWWHU$GDSWHU&DEOH5LQJ7HUPLQDO$GDSWHU&DEOH
NOTE
z 6HOHFWWKHDSSURSULDWHZUHQFKDFFRUGLQJWRSRVLWLYHQHJDWLYHZLUH¿[LQJEROWVSHFL¿FDWLRQVRI WKHVVWHPKXE
ON AC/INV CHG FAULT
OFF
DC Negative Battery Terminal
–
1. Connect the negative ring terminal to the negative WHUPLQDORIWKHVVWHPKXE Tighten the wire retaining EROWZLWKDZUHQFK
33
%DWWHU:LULQJ
‘HYLFHVLGH:LULQJ %DWWHUVLGH:LULQJ
ON AC/INV CHG FAULT
OFF
DC Positive Battery Terminal
2. For your safety, it is recommended to use a DC fuse (400A). Connect the positive ring terminal to the DC fuse. Install the IXVHFDEOHRQWKHRWKHU end of the fuse.
3. Attach the other ring
terminal of the other
HQGRIIXVHFDEOHWRWKH
poisitive terminal of the
VVWHPKXEDQGWLJKWHQ
WKHZLUHUHWDLQLQJEROWZLWK
a wrench.
Using Positive/Negative Busbars Accessory Set
NOTE z
6HOHFWWKHDSSOLFDEOHZUHQFKDFFRUGLQJWRZLUH¿[LQJEROWVSHFL¿FDWLRQVRI3RVLWLYH1HJDWLYH
%XVEDUV
WARNING z
6HOHFWWKHULJKWVL]HRISRVLWLYHQHJDWLYHVLQNDFFRUGLQJWRWKHPD[LPXPFRQWLQXRXV
FKDUJLQJGLVFKDUJLQJFXUUHQWRIWKHEDWWHURSHUDWLRQ Essential Accessories
Gray Anderson 350 Connector to Ring 7HUPLQDO$GDSWHU&DEOH
34
%DWWHU:LULQJ
‘HYLFHVLGH:LULQJ %DWWHUVLGH:LULQJ
1. Connect the Anderson
&RQQHFWRUVRIWKHEDWWHULHV WRWKH$GDSWHU&DEOHVVROG separately).
+ +
–
–
ON AC/INV CHG FAULT
OFF
DC Positive Battery Terminal
2. Connect the positive and negative ring terminals RIWKH$GDSWHU&DEOHVWR the Positive and Negative %XVEDUVQRWLQFOXGHG respectively.
ON AC/INV CHG FAULT
OFF
DC Negative Battery Terminal
3. Attach the negative ring
terminal to the Negative %XVEDUDQGWLJKWHQWKH ZLUHUHWDLQLQJEROWZLWKD wrench.
4. For your safety, it is recommended to use a DC fuse (400A). Connect the positive ring terminal to the DC fuse. Install the fuse wire on the other end of the fuse.
35
%DWWHU:LULQJ
‘HYLFHVLGH:LULQJ %DWWHUVLGH:LULQJ
5. Attach the ring terminal of WKHRWKHUHQGRIIXVHFDEOH WRWKH3RVLWLYH%XVEDUDQG tighten the wire retaining EROWZLWKDZUHQFK
ON AC/INV CHG FAULT
OFF
DC Positive Battery Terminal
Battery Scenario B: Normal Battery Kit
NOTE
z
6HOHFWWKHDSSURSULDWHZUHQFKDFFRUGLQJWRWKHVSHFL¿FDWLRQRIWKHSRVLWLYHQHJDWLYHZLUH
UHWDLQLQJEROWRIWKHVVWHPKXE
z Ensure that the ring terminals are securely connected.
ON AC/INV CHG FAULT
OFF
DC Negative Battery Terminal
–
–
– 12
12
1. Connect the negative ring terminal to the negative terminal of a Normal %DWWHU7LJKWHQWKH ZLUHUHWDLQLQJEROWZLWKD wrench.
–
36
%DWWHU:LULQJ
‘HYLFHVLGH:LULQJ %DWWHUVLGH:LULQJ
ON AC/INV CHG FAULT
OFF
DC Positive Battery Terminal
-
–
2. For your safety, it is recommended to use a DC fuse (400A). Connect the
positive ring terminal of the inverter charger DGDSWHUFDEOHWRWKH’& fuse.
Install the fuse wire on the other end of the fuse.
3. The other ring terminal of the fuse wire is connected to the positive
terminal RIWKH1RUPDO%DWWHU Tighten the wire retaining EROWFORFNZLVHZLWKD
wrench.
37
$&2XWSXW:LULQJ
‘HYLFHVLGH:LULQJ
$&2XWSXW:LULQJ
/RDG:LULQJ
5HFRPPHQGHGURXQG)DXOW&LUFXLW,QWHUUXSWHU)&,
‘HYLFHVLGH:LULQJ
REMOTE
CODNRTYACT
NC
CAN
C
NO
NEGATIVE
CODNRTYACT
NC
L OUTPUNT
C NO
ON OFF
N INPUTL
CHC AC / INV
L FAOULTUTPUNT
ON OFF
N INPUT
HWBpleiegAfahoRsrveeNowrIleNtaoaGgrdkeit,nhingeooinrndsetthrruistcotpiaorovndosuidccatr.risekfusl,ly
HWBpleiegAfahoRsrveeNowrIleNtaoaGgrdkeit,nhingeooinrndsetthrruistcotpiaorovndosuidccatr.risekfusl,ly CHAPRRCOETR W
1. 5XQWKUHHEDUHZLUHVWKURXJKWKH$&2XWSXW/HYHU7HUPLQDO %ORFN
B T S
ONDCRNYCCONTACT
2. Push up the switches of
B T S
ONDCRNYCCONTACT
the wire harness retainer of the AC Output Lever
O
7HUPLQDO%ORFN
ON OFF ON OFF
U
T
P U
O
T
U
T
P
U
T
L T U NP IN N L
L T U NP IN N L
IN
V PE
RR OTTEER CO
C H PARROGTEER
TU
T P U
T
CTINP U
T
B
T
S
ONDCRNYCCONTACT
L
O U T P U T
ON OFF
L T U NP IN N
L
N
IN V
C
PE RR OTTEER CO
H PARROGTEER
TU
T P U
T
CTINP U
T
AC/INV
IN
V PE
RR OT TEER CO
C H PARROGTEER
TU
T P U
T
CTINP U
T
3. Connect the live wire to the (L) terminal, the neutral wire to the (N) terminal, and the ground wire to the ( ) terminal.
NOTE z 6WULSPPRILQVXODWLRQRWKH$&2XWSXWFDEOHZLWKDZLUHVWULSSHU
38
$&2XWSXW:LULQJ
‘HYLFHVLGH:LULQJ /RDG:LULQJ 5HFRPPHQGHGURXQG)DXOW&LUFXLW,QWHUUXSWHU)&,
CAN REMOTE
B T S ONDCRYNCCONTACT
O U T P U T
ON OFF
AC/INV CHG
4. Press down the wire harness retainer of the AC Output /HYHU7HUPLQDO%ORFN
L T U NP IN N
L
IN
V
C
PE
H
RO RTTEERCTOUTPPARROGTEERCTINP
U
U
T
T
NOTE z 7XJDWWKHZLUHWRHQVXUHD¿UPFRQQHFWLRQ
Recommended Accessories AC Load Center
/RDG:LULQJ
NOTE z
)RURXUVDIHWLWLVUHFRPPHQGHGWKDWTXDOL¿HGHOHFWULFLDQVIDPLOLDUZLWKVDIHWFRGHVRI
electrical systems perform the installation. INFO
z 5HDGWKHXVHUPDQXDORIWKH$&ORDGFHQWHUFDUHIXOOEHIRUHLQVWDOODWLRQ 1. Remove the
front cover of the AC load center and connect
WKHWZROLYHZLUHEXVEDUVZLWKDFRSSHUVWULS
39
$&2XWSXW:LULQJ
‘HYLFHVLGH:LULQJ /RDG:LULQJ 5HFRPPHQGHGURXQG)DXOW&LUFXLW,QWHUUXSWHU)&,
REMOTE
CODNRTYACT
NC
CAN
C
NO
NEGATIVE
CHC AC / INV
FAULT
L OUTPUNT
ON OFF
N INPUTL
HWBpleiegAfahoRsrveeNowrIleNtaoaGgrdkeit,nhingeooinrndsetthrruistcotpiaorovndosuidccatr.risekfusl,ly
HWBpleiegAfahoRsrveeNowrIleNtaoaGgrdkeit,nhingeooinrndsetthrruistcotpiaorovndosuidccatr.risekfusl,ly CHAPRRCOETR W
Pure Sine Wave Inverter Charger
PE N LN
2. Connect the AC Output FDEOHRIWKHLQYHUWHU charger to the AC load center. Connect the live wire to the (L) terminal, the neutral wire to the (N) terminal, and the ground ZLUHWRWKH3(EXVEDU
I/ON O/OFF
I/ON O/OFF
N
N
PE
3. Select an appropriate FLUFXLWEUHDNHUDFFRUGLQJ to the operating load current, and connect the load to the AC load center. Connect the live wire to the (L) terminal, the neutral wire to the (N) terminal, and the ground wire to the 3(EXVEDU
4. Install the front cover of the AC load center and turn on all WKHFLUFXLWEUHDNHUVLQWKH$&ORDGFHQWHU
I/ON O/OFF
I/ON O/OFF
40
$&2XWSXW:LULQJ
‘HYLFHVLGH:LULQJ /RDG:LULQJ 5HFRPPHQGHGURXQG)DXOW&LUFXLW,QWHUUXSWHU)&,
5HFRPPHQGHGURXQG)DXOW&LUFXLW,QWHUUXSWHU)&,
A ground-fault circuit interrupter, or GFCI, is a device that help protect
people from electric
VKRFNVEGHHQHUJL]LQJDFLUFXLWRUSRUWLRQRIDFLUFXLWZLWKLQDQHVWDEOLVKHGSHULRGRIWLPHZKHQ
DFXUUHQWWRJURXQGH[FHHGVVRPHSUHGHWHUPLQHGYDOXHWKDWLVOHVVWKDQWKDWUHTXLUHGWRRSHUDWH
WKHRYHUFXUUHQWGHYLFHFLUFXLWEUHDNHURUIXVHRIWKHVXSSOFLUFXLW)&,VDUHXVXDOOUHTXLUHG
in wet or damp locations.
:KLOHWKHLQYHUWHULVHTXLSSHGZLWKD)&,LWLVUHFRPPHQGHGWRLQVWDOODQH[WHUQDO)&,ZKHUH
you can manually test the circuit.
7KHIROORZLQJWDEOHOLVWV)&,VWKDWPHHWWKHVSHFL¿FDWLRQVDQGZLOOIXQFWLRQSURSHUOZKHQWKH
are connected to the AC Outlets of the inverter.
Tested GFCI Models
Manufacturer
Model Number
Leviton
GFNT2
+XEEHOO +XEEHOO
GFP1305 GF15WLA
WARNING z
5LVNRIHOHFWULFDOVKRFN8VHRQOJURXQGIDXOWFLUFXLWLQWHUUXSWHUV>UHFHSWDFOHVRUFLUFXLW
EUHDNHUV@FRPSDWLEOHZLWKRXULQYHUWHU
CAUTION z GFCIs shall be installed in a recreational vehicle’s wiring system
to protect all branch
circuits.
41
$&,QSXW:LULQJ
$&,QSXW:LULQJ
The AC input is optionally installed on demand.
Shore Power or Generator (120V Single Phase, 40A Max.)
ON AC/INV CHG FAULT
OFF
REMOTE
CODNRTYACT
NC
CAN
C
NO
NEGATIVE
ON OFF
L
OUTPUNT
N
NC
INPUTL
C
FAULT CHC
NO
AC / INV
L OUTPUNT
ON OFF
N INPUTL
HWBpleiegAfahoRsrveeNowrIleNtaoaGgrdkeit,nhingeooinrndsetthrruistcotpiaorovndosuidccatr.risekfusl,ly
HWBpleiegAfahoRsrveeNowrIleNtaoaGgrdkeit,nhingeooinrndsetthrruistcotpiaorovndosuidccatr.risekfusl,ly CHAPRRCOETR W
AC Input Lever Terminal Block
1. 5XQWKH$&SRZHUFDEOH through the AC Input &DEOH*URPPHW
NOTE
z 7KH$&,QSXW&DEOHURPPHWKDVDQLQQHUGLDPHWHURIPP3URSHUOVHOHFWWKH$&FDEOH
VL]HDQGHQVXUHWKDWWKUHHEDUHZLUHVFDQUXQWKURXJKWKHJURPPHWDWWKHVDPHWLPH
z 0DNHVXUHWKH$&LQSXWFXUUHQWLVQRJUHDWHUWKDQ$2WKHUZLVHWKHLQYHUWHUFKDUJHU
FDQQRWZRUN
z 7KHVL]HRIWKH$&LQSXWFDEOHLVDWOHDVW$:
WARNING
z 5LVNRIHOHFWULFVKRFN0DNHVXUHWKHVKRUHSRZHURUWKHJHQHUDWRULVGLVFRQQHFWHGGXULQJ
AC input wiring.
INFO
z When connecting the inverter charger to an AC Input, read the user manual of the AC Input for wiring instructions.
ON OFF
CAN REMOTE
CAN
B T S ONDCRYNCCONTACT
O U T P U T
B
T
S
ONDCRNYCCONTACT
O U T P U T
ON OFF
AC/INV CHG
2. Push up on the lever of the $&,QSXW7HUPLQDO%ORFN
L T U NP IN N L
L T U NP IN N L
IN
V
C
PE
H
RO RTTEERCTOUTPPARUROGTEERCTINPU
T
T
IN
V
C
PE
H
RO RTTEERCTOUTPPUARROGTEERCTINPU
T
T
42
$&,QSXW:LULQJ
B T S
N
DRY COONNTCACNTC ON OFF
L T U NP IN N
L
O U
LT P U T
IN
V
C
PE
H
RO RTTEERCTOUTPPARUROGTEERCTINPU
T
T
3. Connect the live wire to the (L) terminal, the neutral wire to the (N) terminal, and the ground wire to the ( ) terminal.
NOTE
z 6WULSPPRIWKHLQVXODWLRQRWKH$&LQSXWFDEOHZLWKDZLUHVWULSSHU
z <RXFDQRQOFRQQHFWWKH$&LQSXWWRWKH$&,QSXW/HYHU7HUPLQDO%ORFN2WKHUZLVHWKH
LQYHUWHUFKDUJHUZLOOEHGDPDJHG
CAN REMOTE
B T S ONDCRYNCCONTACT
AC/INV CHG
4. Press down the switch of the harness retainer of the AC ,QSXW/HYHU7HUPLQDO%ORFN
ON OFF
O U T P U T
L T U NP IN N
L
IN
V
C
PE
H
RO RTTEERCTOUTPPARROGTEERCTINP
U
U
T
T
NOTE z 7XJDWWKHZLUHWRHQVXUHD¿UPFRQQHFWLRQ
43
Automatic Generator Start
Automatic Generator Start
If the inverter charger is connected to an AC Power Supply (AC Input) and the
generator can automatically start or stop. It is recommended to connect the
generator to the Dry Contact Relay 7HUPLQDO%ORFNZLWKDVLJQDOFDEOH When the
voltage of the inverter charger is lower than the set voltage in Program 96,
the inverter
FKDUJHUZLOODXWRPDWLFDOOVWDUWWKHJHQHUDWRUDQGFKDUJHWKHEDWWHUZKLOHWKHORDGLVVXSSOLHGE
the generator. When the voltage of the inverter charger is higher than the set
value, the inverter charger will automatically shut down the generator.
INFO z
5HDGWKHXVHUPDQXDORIWKH$&,QSXWFDUHIXOOEHIRUHFRQQHFWLRQ0DNHVXUHWKHJHQHUDWRU
can automatically start or stop. Identify NC (normally closed contact), NO
(normally open contact), and C (common static contact) of the generator and
ensure signal lines are connected properly.
NOTE z <RXFDQVHWWKHYROWDJHRIWKHLQYHUWHUFKDUJHULQ3URJUDP7KHYROWDJHVKRXOGEHVHW
DIWHUWKHLQYHUWHUFKDUJHULVWXUQHGRQ)LQLVKWKHLQVWDOODWLRQRIWKHLQYHUWHUFKDUJHU¿UVW)RU
more instructions, read Program Codes in the user manual. z
‘RQRWVWRUHWKHLQYHUWHUFKDUJHUZLWKDXWRPDWLFJHQHUDWRUVWDUWIHDWXUHHQDEOHG*HQHUDWRUV
exhaust dangerous fumes in operation.
WARNING z 5LVNRIHOHFWULFVKRFN0DNHVXUHWKH$&,QSXWLVWXUQHGRGXULQJFRQQHFWLRQ
Essential Accessories
Signal Line X 3
NOTE z 7KHUHLVQRSRODULWUHTXLUHPHQWIRUWKHVLJQDOOLQH z
6WULSVRPHLQVXODWLRQRWKHVLJQDOOLQHEXVLQJDZLUHVWULSSHUDFFRUGLQJWRWKHGHSWKRIWKH
wiring hole.
44
Automatic Generator Start
:LULQJ’LDJUDP
AC Generator
AC Input Positive (DC) Negative (DC) Signal Line
- Battery System (12V)
ON AC/INV CHG FAULT
OFF
Dry Contact Relay Terminal Block
INFO
z Connect three signal lines to NC (normally closed contact), NO (normally open contact), and
C (common static contact) of the AC Input. For more instructions, read the user manual of
AC Input.
pBleefaorsee rweoardkitnhge ionnsttrhiusctiproondsuccta.refully
REMOTE
CODNRTYACT
NC
CAN
C
NO
NEGATIVE
CHC AC / INV
FAULT
ON OFF
L OUTPUNT
N INPUTL
HWBpleiegAfahoRsrveeNowrIleNtaoaGgrdkeit,nhingeooinrndsetthrruistcotpiaorovndosuidccatr.risekfusl,ly
HWBpleiegAfahoRsrveeNowrIleNtaoaGgrdkeit,nhingeooinrndsetthrruistcotpiaorovndosuidccatr.risekfusl,ly CHAPRRCOETR W
Pure Sine W
1. Remove four retaining
QXWVRIWKH$&&DEOH $FFHVVRU3ODWHEWXUQLQJ WKHPFRXQWHUFORFNZLVH with a Phillips
screwdriver.
REMOTE
CODNRTYACT
NC
CAN
C
NO
NEGATIVE
CHC AC / INV
FAULT
L OUTPUNT
ON OFF
N INPUTL
HWBpleiegAfahoRsrveeNowrIleNtaoaGgrdkeit,nhingeooinrndsetthrruistcotpiaorovndosuidccatr.risekfusl,ly CHAPRRCOETR W
HWBpleiegAfahoRsrveeNowrIleNtaoaGgrdkeit,nhingeooinrndsetthrruistcotpiaorovndosuidccatr.risekfusl,ly
2. 5HPRYHWKH$&&DEOH Accessory Plate.
45
Automatic Generator Start
REMOTE
CODNRTYACT
NC
CAN
C
NO
NEGATIVE
CHC AC / INV
FAULT
L OUTPUNT
ON OFF
N INPUTL
HWBpleiegAfahoRsrveeNowrIleNtaoaGgrdkeit,nhingeooinrndsetthrruistcotpiaorovndosuidccatr.risekfusl,ly CHAPRRCOETR W
CODNRTYACT
NC C NO
HWBpleiegAfahoRsrveeNowrIleNtaoaGgrdkeit,nhingeooinrndsetthrruistcotpiaorovndosuidccatr.risekfusl,ly
3. Run three signal lines
through the Remote &
OFF
$FFHVVRU&DEOH(QWU
REMOTE
CODNRTYACT
NC
CAN
C
NO
L OUTPUNT
ON OFF
N INPUTL
Close
HWBpleiegAfahoRsrveeNowrIleNtaoaGgrdkeit,nhingeooinrndsetthrruistcotpiaorovndosuidccatr.risekfusl,ly
Open CHAPRRCOETR W
NC C NO
NC C NO
4. 7XUQWKHFDEOHUHWDLQHU screws of NC, C and NO of Dry Contact
5HOD7HUPLQDO%/RFN FRXQWHUFORFNZLVHZLWK a slotted screwdriver to
HQVXUHWKDWWKHFDEOH retainers are open.
5. Connect three signal lines to the corresponding NC, C, and NO wiring
holes.
REMOTE
CODNRTYACT
NC
CAN
C
NO
REMOTE
L OUTPUNT
ON OFF
N INPUTL
DRY CONTACT
NC C NO
HWBpleiegAfahoRsrveeNowrIleNtaoaGgrdkeit,nhingeooinrndsetthrruistcotpiaorovndosuidccatr.risekfusl,ly CHAPRRCOETR W
NOTE
z Some generators only have NC (normally closed contact) and C (common static
contact) or NO (normally open contact) and C (common static contact). You can
connect them on demand.
46
Automatic Generator Start
REMOTE
CODNRTYACT
NC
CAN
C
NO
ON OFF
L OUTPUNT
N INPUTL
HWBpleiegAfahoRsrveeNowrIleNtaoaGgrdkeit,nhingeooinrndsetthrruistcotpiaorovndosuidccatr.risekfusl,ly CHAPRRCOETR W
6. 7XUQWKHFDEOHUHWDLQHU screws of NC, C and NO FORFNZLVHZLWKDVORWWHG screwdriver to fasten the FDEOH
NOTE
z ‘RQRWRYHUWLJKWHQWKHFDEOHUHWDLQHUVFUHZV2WKHUZLVHLWZLOOOHDGWRVWULSSHGVFUHZVRU VFUHZEHQGLQJ
REMOTE
CODNRTYACT
NC
CAN
C
NO
NEGATIVE
ON OFF
L OUTPUNT
N INPUTL
CHC AC / INV
FAULT
HWBpleiegAfahoRsrveeNowrIleNtaoaGgrdkeit,nhingeooinrndsetthrruistcotpiaorovndosuidccatr.risekfusl,ly CHAPRRCOETR W
7. ,QVWDOOWKH$&&DEOH Accessory Plate.
HWBpleiegAfahoRsrveeNowrIleNtaoaGgrdkeit,nhingeooinrndsetthrruistcotpiaorovndosuidccatr.risekfusl,ly
pBleefaorsee rweoardkitnhge ionnsttrhiusctiproondsuccta.refully
REMOTE
CODNRTYACT
NC
CAN
C
NO
NEGATIVE
CHC AC / INV
FAULT
L OUTPUNT
ON OFF
N INPUTL
HWBpleiegAfahoRsrveeNowrIleNtaoaGgrdkeit,nhingeooinrndsetthrruistcotpiaorovndosuidccatr.risekfusl,ly
HWBpleiegAfahoRsrveeNowrIleNtaoaGgrdkeit,nhingeooinrndsetthrruistcotpiaorovndosuidccatr.risekfusl,ly CHAPRRCOETR W
Pure Sine W
8. Install four retaining
QXWVRIWKH$&&DEOH $FFHVVRU3ODWHEWXUQLQJ WKHPFRXQWHUFORFNZLVH with a Phillips
screwdriver.
If your inverter charger uses the DC Generator as the power supply and the DC
Generator can automatically start or stop, you can connect the DC Generator to
the inverter charger via the signal line. The inverter charger will
automatically start and stop the generator according to the voltage you set.
The signal line is connected in the same way as the AC Input.
NOTE z 0DNHVXUHWKDWWKH’&*HQHUDWRULVSURSHUOFRQQHFWHGWRWKHLQYHUWHUFKDUJHU
47
Communication
Inter-Device Communication
Communication
Monitoring Device Communication
The communication connection is optional. The REGO Inverter Charger can communicate with RWKHU5(*2GHYLFHVDQGPRQLWRULQJGHYLFHVHQDEOLQJVDIHRSHUDWLRQVPDUWFRQWUROUHPRWH PRQLWRULQJDQGSURJUDPPDEOHVHWWLQJV
WARNING
z 5LVNRIHOHFWULFVKRFN7XUQRWKHLQYHUWHUFKDUJHUDQGWKHSRZHUVXSSOGHYLFHVFRQQHFWHG
WRWKHLQYHUWHUFKDUJHUEHIRUHFRQQHFWLRQ
z
:HDUSURSHUSURWHFWLYHHTXLSPHQWDQGXVHLQVXODWHGWRROVGXULQJRSHUDWLRQ%HFDUHIXOZKHQ
WRXFKLQJEDUHWHUPLQDOVRIFDSDFLWRUVDVWKHPDUHWDLQKLJKOHWKDOYROWDJHVHYHQDIWHUWKH
power is removed.
Inter-Device Communication
‘HSHQGLQJRQWKHLQVWDOODWLRQFRQGLWLRQWKH59&FRPPXQLFDWLRQFRQQHFWLRQVEHWZHHQWKH
LQYHUWHUFKDUJHUDQGRWKHU5(*2GHYLFHVFDQEHHVWDEOLVKHGZLWKEDFNERQHRUGDLVFKDLQ
WRSRORJ7KHLQWHUGHYLFHFRPPXQLFDWLRQDOORZVWKHLQYHUWHUFKDUJHUWRGQDPLFDOODGMXVWWKH
FKDUJLQJSUR¿OHIRUDQRSWLPDODQGVDIHFKDUJH
Backbone Topology
7KHEDFNERQHWRSRORJDSSOLHVWR59VWKDWDUHLQWHJUDWHGZLWK59&EXVHVZLWKEXLOWLQ
UHVLVWRUVRQERWKHQGV&KHFNWKH59XVHUPDQXDOIRUGHWDLOVRUFRQWDFWWKH59PDQXIDFWXUHULI
necessary.
For technical support from Renogy, please contact us through renogy.com
/contact-us/.
CAUTION
z &RQQHFWGHYLFHVWRWKHLQYHUWHUFKDUJHUDFFRUGLQJWRWKHZLULQJGLDJUDPSURYLGHGEWKH59
manufacturer.
&KRRVHSURSHUFRPPXQLFDWLRQFDEOHVDFFRUGLQJWRRXUVSHFL¿FGHPDQGV Recommended
Accessories
/33OXJ3LQWR%DUH ‘URS&DEOHV
Drop Plugs
Split Joint Pliers
48
Communication
Inter-Device Communication Monitoring Device Communication
NOTE
z 7KHGURSFDEOHVKDOOQRWH[FHHGIHHWPDQGWKH59&EXVVKDOOQRWH[FHHG feet (30 m).
z ‘LHUHQWGURSVRFNHWVDUHXVHGRQWKH59&EXVEGLHUHQW59PDQXIDFWXUHUV6HOHFWWKH
‘URS3OXJVWKDWPDWFKWKHGURSVRFNHWVIRUWKHLQWHUGHYLFHFRPPXQLFDWLRQFRQQHFWLRQV,I
RXDUHQRWVXUHDERXWWKH’URS3OXJVHOHFWLRQFKHFNZLWKWKH59PDQXIDFWXUHU7KLVXVHU
PDQXDOWDNHVWKH0LQL&ODPS,,SOXJ3LQDVDQH[DPSOH
z ‘LHUHQW’URS3OXJVIROORZGLHUHQWSLQRXWV&ULPSWKH’URS3OXJVRQWKH’URS&DEOHV
IROORZLQJWKHFRUUHFWSLQRXW,IRXDUHQRWVXUHDERXWWKH’URS3OXJSLQRXWFKHFNZLWKWKH
59PDQXIDFWXUHU7KLVXVHUPDQXDOWDNHVWKHSLQRXWRIWKH0LQL&ODPS,,SOXJ3LQDVDQ example.
REMOTE
CODNRTYACT
NC
CAN
C
NO
NEGATIVE
L OUTPUNT
ON OFF
N INPUTL
CHC AC / INV
FAULT
REMOTE
HWBpleiegAfahoRsrveeNowrIleNtaoaGgrdkeit,nhingeooinrndsetthrruistcotpiaorovndosuidccatr.risekfusl,ly
HWBpleiegAfahoRsrveeNowrIleNtaoaGgrdkeit,nhingeooinrndsetthrruistcotpiaorovndosuidccatr.risekfusl,ly CHAPRRCOETR W
Pure Sine Wave Inverter Charger
1. Insert the RJ45 connector RI5-3OXJWRWKH%DUH ‘URS&DEOHWKURXJKWKH Remote & Accessory &DEOH(QWU
ON OFF
REMOTE
CODNRTYACT NC C NO
CAN BTS
2. Connect the RJ45 connector to the Communication Port &$1%XV
C ONDTR AY C T NO CNC
1 2 345 678
3. The white green CAN_H wire goes to pin 2 and the white orange CAN_L wire goes to pin 3. Leave pin 1 and pin 4 empty.
4321
49
Communication
Inter-Device Communication Monitoring Device Communication
4. 6TXHH]HWKHFULPSDUHDVRIWKH’URS3OXJVZLWKWKH6SOLW Joint Pliers.
5. Locate the drop tap (not included) on the RV-C EXVWKDWLVWKHFORVHVWWR the installation site of the inverter charger. The drop taps are usually located DERYHWKHHQWUGRRULQ WKHEDWKURRPRUXQGHUWKH EHGLQWKH59
NOTE
z If you fail to locate the drop taps, please contact the RV manufacturer for help.
CHC AC / INV
FAULT
REMOTE
CODNRTYACT
NC
CAN
C
NO
NEGATIVE
ON OFF
L OUTPUNT
N INPUTL
HWBpleiegAfahoRsrveeNowrIleNtaoaGgrdkeit,nhingeooinrndsetthrruistcotpiaorovndosuidccatr.risekfusl,ly
HWBpleiegAfahoRsrveeNowrIleNtaoaGgrdkeit,nhingeooinrndsetthrruistcotpiaorovndosuidccatr.risekfusl,ly CHAPRRCOETR W
6. Connect the Drop Plugs
RQWKHGURSFDEOHVDQG
Pure Sine W
other REGO devices to
WKHGURSVRFNHWVRQWKH
drop tap.
NOTE
z ‘LHUHQWGURSWDSVDUHXVHGRQWKH59&EXVEGLHUHQW59PDQXIDFWXUHUV7KLVXVHU
PDQXDOWDNHVWKHVRFNHWGURSWDSDVDQH[DPSOH
50
Communication
Inter-Device Communication Monitoring Device Communication
Daisy Chain Topology 7KHGDLVFKDLQWRSRORJDSSOLHVWR59VWKDWDUHQRWLQWHJUDWHGZLWK59&EXVHV
NOTE z ‘RQRWSODFHWKHLQYHUWHUFKDUJHUDWWKH¿UVWRUODVWRIWKHGDLVFKDLQQHWZRUN Recommended Accessories
LP16 Plug (7-Pin) to RJ45 Communication Adapter
&DEOH
LP16 Terminator Plug (7-Pin)
5-1HWZRUNWR3RUW Ethernet Adapter Splitter
NOTE
z 6HOHFWWKHDSSURSULDWHFRPPXQLFDWLRQFDEOHVROGVHSDUDWHODFFRUGLQJWRWKHGLVWDQFH EHWZHHQGHYLFHV7KHFRPPXQLFDWLRQFDEOHVKRXOGEHOHVVWKDQIHHWP
REMOTE
CODNRTYACT
NC
CAN
C
NO
NEGATIVE
L OUTPUNT
ON OFF
N INPUTL
CHC AC / INV
FAULT
REMOTE
HWBpleiegAfahoRsrveeNowrIleNtaoaGgrdkeit,nhingeooinrndsetthrruistcotpiaorovndosuidccatr.risekfusl,ly
HWBpleiegAfahoRsrveeNowrIleNtaoaGgrdkeit,nhingeooinrndsetthrruistcotpiaorovndosuidccatr.risekfusl,ly CHAPRRCOETR W
Pure Sine Wave Inverter Charger
1. Insert the RJ45 connector RI5-1HWZRUNWR Port Ethernet Adapter Splitter through the Remote & Accessory &DEOH(QWU
ON OFF
REMOTE
CODNRTYACT NC C NO
CAN BTS
2. Connect the RJ45 connector to the Communication Port &$1%XV
C ONDTR AY C T NO CNC
51
Communication
Inter-Device Communication Monitoring Device Communication
REMOTE
CODNRTYACT
NC
CAN
C
NO
NEGATIVE
ON OFF
L OUTPUNT
N INPUTL
HWBpleiegAfahoRsrveeNowrIleNtaoaGgrdkeit,nhingeooinrndsetthrruistcotpiaorovndosuidccatr.risekfusl,ly
3. Connect the two RJ45 connectors of LP16 Plug (7-Pin) to the RJ45 Communication Adapter &DEOHVWRWKH5- 1HWZRUNWR3RUW Ethernet Adapter Splitter.
REMOTE
CODNRTAYCT
NC
CAN
C
NO
NEGATIVE
CHC AC / INV
FAULT
ON OFF
L OUTPUNT
N INPUTL
HWBpleiegAfahoRsrveeNowrIleNtaoaGgrdkeit,nhingeooinrndsetthrruistcotpiaorovndosuidccatr.risekfusl,ly
HWBpleiegAfahoRsrveeNowrIleNtaoaGgrdkeit,nhingeooinrndsetthrruistcotpiaorovndosuidccatr.risekfusl,ly CHAPRRCOETR W
Pure Sine Wave Inverter Charger
4. Connect the other ends of the LP16 Plug (7-Pin) to RJ45 Communication Adapter &DEOHVWRWKHYDFDQW&$1 communication ports of other REGO devices. Insert the terminal plugs (sold separately) into the vacant CAN communication port of WKH¿UVWDQGODVW5(*2 devices.
52
Communication
Inter-Device Communication Monitoring Device Communication
Monitoring Device Communication
‘HSHQGLQJRQWKHDSSOLFDWLRQWKHVKRUWUDQJHRUORQJUDQJHFRPPXQLFDWLRQFRQQHFWLRQVFDQEH
HVWDEOLVKHGEHWZHHQWKHLQYHUWHUFKDUJHUDQGPRQLWRULQJGHYLFHV7KHPRQLWRULQJGHYLFHDOORZV
for the monitoring and programming of the inverter charger or even the
complete system.
NOTE
z 0DNHVXUHWKH%OXHWRRWKRIRXUSKRQHLVWXUQHGRQ z Scan the QR code on the last page
of the user manual to download the DC Home app.
z 7KHYHUVLRQRIWKH’&+RPHDSSPLJKWKDYHEHHQXSGDWHG,OOXVWUDWLRQVLQWKHXVHUPDQXDO
DUHIRUUHIHUHQFHRQO)ROORZWKHLQVWUXFWLRQVEDVHGRQWKHFXUUHQWDSSYHUVLRQ
z 0DNHVXUHWKDWWKHLQYHUWHUFKDUJHULVSURSHUOLQVWDOOHGDQGSRZHUHGRQEHIRUHLWLVSDLUHG
with the DC Home app.
Short-Range Monitoring
,IRQOVKRUWUDQJHPRQLWRULQJLVUHTXLUHGFRQQHFWWKHLQYHUWHUFKDUJHUWRWKH’&+RPHDSS GLUHFWOWKURXJKWKH%OXHWRRWKRIRXUSKRQH
Short-Range Monitoring
1. Open the DC Home app. Tap + to search for new devices.
My Renogy
75%
10h left
Device
Commonly
BaDtteeryvicSeescurity RBT12400LFPL-
25 % 0A
Night Controller RCC60RVRU
Scene
Community
0
A W
0
Personal
INPUTBATT
OUTPUTBATT
100% 25%
BYPASS
LI CHARGING
AC / INV
CHC
FAULT
ON OFF
HBpleiegAfahoRsrveeNoIwrlNetaoaGgrdkeit,nhingeooinrndsetthrruistcotpiaorovndosuidccatr.risekfusl,ly
Pure Sine Wave Inverter Charger
NOTE
z Keep the phone within 10 feet (3 m) of the inverter charger.
2. Tap &RQ¿UPto add the newly found device to the device list.
Found Devices
RIV1230RCL-1SS
BT-TH-161CFF52
Cancel
Confirm
Confirm
53
Communication
Inter-Device Communication Monitoring Device Communication
My Renogy
3. Tap the inverter icon to enter the device information interface.
25%
Device
Battery
Inverter
RBT12400LFPL- 25 % 0A
RIV1230RCL-1SS BT-TH-161CFF52 A
0W
12.0 V
Device
Scene
Community
Me
Inverter
RIV1230RCL-1SS BT-TH-161CFF52
12.0 V
RIV1230RCL-1SS
Shore Power
Load
Battery Boost
Inverter/Solar Charging Screen
Load Power Mode Charge Priority
Utility First
Utility First
Status BULK Charge
Load Watts Load Volts Load Amps Inveter Output Hz Battery Charging Watts Battery Vots
1000 W 120 V
10 A 60 Hz 200 W 12 V
4. &KHFNWKHRSHUDWLRQVWDWXVRIWKHLQYHUWHUFKDUJHULQWKLV interface.
Long-Range Monitoring
,IORQJUDQJHFRPPXQLFDWLRQDQGSURJUDPPLQJDUHUHTXLUHGFRQQHFWWKHLQYHUWHUFKDUJHUWR
5HQRJ21(WKURXJK%OXHWRRWKRUZLUHVDQGWKH5HQRJ21(WRWKH’&+RPHDSSWKURXJK Wi-Fi.
Recommended Accessories
Renogy ONE
NOTE z 0DNHVXUHWKDWWKH5HQRJ21(LVSRZHUHGRQEHIRUHWKHFRQQHFWLRQ
INFO z Read the user manual of Renogy ONE at renogy.comEHIRUHWKHFRQQHFWLRQ
54
Communication
Inter-Device Communication Monitoring Device Communication
:LUHOHVVFRQQHFWLRQ
INPUTBATT
OUTPUTBATT
100% 25%
BYPASS
LI CHARGING
AC / INV
CHC
FAULT
ON OFF
HBpleiegAfahoRsrveeNoIwrlNetaoaGgrdkeit,nhingeooinrndsetthrruistcotpiaorovndosuidccatr.risekfusl,ly
Pure Sine Wave Inverter Charger
12:33 12/23
80 %
FCUHLALRYED IN CURRENT
2d13h 2.33A
RBT10008H0J%D 1000 Ah
HOME
RBT10000HWJD 0
Setting Device
12V Power Supply
My Renogy
10h left
75%
Commonly
Security
Night
Devices Battery
RBT12400LFPL-
25 % 0A
Controller
RCC60RVRU A
0W 0
Device
Scene
Community
Personal
Connect the inverter charger to the Renogy ONE (sold separately) through the
%OXHWRRWKRIRXUSKRQHDQG pair the Renogy ONE with the DC Home app through Wi-Fi.
Monitor the inverter charger on the Renogy ONE or the DC Home app.
NOTE
z 0DNHVXUHWKHLQYHUWHUFKDUJHUGRHVQRWFRPPXQLFDWHZLWKDQRWKHUGHYLFH z Keep the
phone within 10 feet (3 m) of the inverter charger. :LUHGFRQQHFWLRQ
5HFRPPHQGHG$FFHVVRULHV%DFNERQH7RSRORJ
5-3OXJWR%DUH’URS&DEOH
Common Drop Tap
NOTE
z 6HOHFWWKHDSSURSULDWHFRPPXQLFDWLRQFDEOHVROGVHSDUDWHODFFRUGLQJWRWKHGLVWDQFH EHWZHHQGHYLFHV7KHFRPPXQLFDWLRQFDEOHVKRXOGEHOHVVWKDQIHHWP
Backbone Topology
12V Power Supply
REMOTE
CODNRTYACT
NC
CAN
C
NO
NEGATIVE
CHC AC / INV
FAULT
L OUTPUNT
N INPUTL
HWBpleiegAfahoRsrveeNowrIleNtaoaGgrdkeit,nhingeooinrndsetthrruistcotpiaorovndosuidccatr.risekfusl,ly
HWBpleiegAfahoRsrveeNowrIleNtaoaGgrdkeit,nhingeooinrndsetthrruistcotpiaorovndosuidccatr.risekfusl,ly CHAPRRCOETR W
1. Replace the terminated
drop tap at either end of
Pure Sine W
WKH59&EXVZLWKWKH
Common Drop Tap (not
included). Secure the
EDUHZLUHVRIWKH’URS
&DEOHQRWLQFOXGHGRQWR
WKHWHUPLQDOEORFNSOXJRI
the Common Drop Tap
following the terminal
EORFNSOXJSLQRXW3OXJWKH
‘URS&DEOHWRWKH5-
port of Renogy ONE.
55
Communication
Inter-Device Communication Monitoring Device Communication
NOTE
z ‘LHUHQWWHUPLQDOEORFNSOXJVDUHXVHGRQGLHUHQW&RPPRQ’URS7DSVDQGIROORZGLHUHQW SLQRXWV,IRXDUHXQVXUHDERXWWKHSLQRXWRIWKHWHUPLQDOEORFNSOXJFRQWDFWWKH59 manufacturer.
z Refer to %DFNERQH7RSRORJ for more instructions.
My Renogy
10h left
75%
Commonly
Security
Night
Devices Battery
RBT12400LFPL-
25 % 0A
Controller
RCC60RVRU A
0W 0
Device
Scene
Community
Personal
12:33 12/23
80 %
FCUHLALRYED IN CURRENT
2d13h 2.33A
RBT10008H0J%D 1000 Ah
HOME
RBT10000HWJD 0
Setting Device
12V Power Supply
2. Monitor and program the complete system on Renogy ONE or the DC Home app.
REMOTE
CODNRTYACT
NC
CAN
C
NO
NEGATIVE
NOTE z Keep the phone within 10 feet (3 m) of the inverter charger.
5HFRPPHQGHG$FFHVVRULHV’DLV&KDLQ7RSRORJ
LP16 Plug (7-Pin) to RJ45 Communication $GDSWHU&DEOH
NOTE z
6HOHFWWKHDSSURSULDWHFRPPXQLFDWLRQFDEOHVROGVHSDUDWHODFFRUGLQJWRWKHGLVWDQFH
EHWZHHQGHYLFHV7KHFRPPXQLFDWLRQFDEOHVKRXOGEHOHVVWKDQIHHWP
56
Communication
Inter-Device Communication Monitoring Device Communication
Daisy Chain Topology
REMOTE
CODNRTYACT
NC
CAN
C
NO
NEGATIVE
CHC AC / INV
FAULT
ON OFF
L OUTPUNT
N INPUTL
HWBpleiegAfahoRsrveeNowrIlNetaoaGgrdkeit,nhingeooinrndsetthrruistcotpiaorovndosuidccatr.risekfusl,ly
HWBpleiegAfahoRsrveeNowrIleNtaoaGgrdkeit,nhingeooinrndsetthrruistcotpiaorovndosuidccatr.risekfusl,ly CHAPRRCOETR W
Pure Sine Wave Inverter Charger
1. Remove the Terminator Plug from the REGO device at either end of the daisy chain.
ODNRTYACT NC C NO
NEGATIVE
CHC AC / INV
FAULT
L OUTPUNT
ON OFF
N INPUTL
HWBpleiegAfahoRsrveeNowrIleNtaoaGgrdkeit,nhingeooinrndsetthrruistcotpiaorovndosuidccatr.risekfusl,ly
HWBpleiegAfahoRsrveeNowrIleNtaoaGgrdkeit,nhingeooinrndsetthrruistcotpiaorovndosuidccatr.risekfusl,ly CHAPRRCOETR W
Pure Sine Wave Inverter Charger
12:33 12/23
80 %
FCUHLALRYED IN CURRENT
2d13h 2.33A
RBT10008H0J%D 1000 Ah
HOME
RBT10000HWJD 0
Setting Device
2. Connect the Renogy ONE to the free CAN Communication Port on the REGO device with the Communication Adapter &DEOHVROGVHSDUDWHO
12V Power Supply
My Renogy
10h left
75%
Commonly
Security
Night
Devices Battery
RBT12400LFPL-
25 % 0A
Controller
RCC60RVRU A
0W 0
Device
Scene
Community
Personal
3. Pair Renogy ONE with the DC Home app. Monitor and program the complete system on the Renogy ONE or the DC Home app.
NOTE z Keep the phone within 10 feet (3 m) of the inverter charger.
57
Putting Plates Back
Inter-Device Communication
Putting Plates Back
Monitoring Device Communication
Reinstall the plates into the inverter charger after wiring.
REMOTE
CODNRTYACT
NC
CAN
C
NO
NEGATIVE
CHC AC / INV
FAULT
L OUTPUNT
ON OFF
N INPUTL
HWBpleiegAfahoRsrveeNowrIleNtaoaGgrdkeit,nhingeooinrndsetthrruistcotpiaorovndosuidccatr.risekfusl,ly
HWBpleiegAfahoRsrveeNowrIleNtaoaGgrdkeit,nhingeooinrndsetthrruistcotpiaorovndosuidccatr.risekfusl,ly CHAPRRCOETR W
1. &KHFNDQGPDNHVXUHDOOFDEOHFRQQHFWLRQVDUHWLJKWDQG secure.
REMOTE
CODNRTYACT
NC
CAN
C
NO
NEGATIVE
CHC AC / INV
FAULT
L OUTPUNT
ON OFF
N INPUTL
HWBpleiegAfahoRsrveeNowrIleNtaoaGgrdkeit,nhingeooinrndsetthrruistcotpiaorovndosuidccatr.risekfusl,ly
HWBpleiegAfahoRsrveeNowrIleNtaoaGgrdkeit,nhingeooinrndsetthrruistcotpiaorovndosuidccatr.risekfusl,ly CHAPRRCOETR W
REMOTE
CODNRTYACT
NC
CAN
C
NO
NEGATIVE
CHC AC / INV
FAULT
L OUTPUNT
ON OFF
N INPUTL
HWBpleiegAfahoRsrveeNowrIleNtaoaGgrdkeit,nhingeooinrndsetthrruistcotpiaorovndosuidccatr.risekfusl,ly
HWBpleiegAfahoRsrveeNowrIleNtaoaGgrdkeit,nhingeooinrndsetthrruistcotpiaorovndosuidccatr.risekfusl,ly CHAPRRCOETR W
2. ,QVWDOOWKH’&&DEOH3ODWH and drive the two panel
VFUHZVFORFNZLVHWR¿[WKH plate.
REMOTE
CODNRTYACT
NC
CAN
C
NO
NEGATIVE
CHC AC / INV
FAULT
L OUTPUNT
ON OFF
N INPUTL
HWBpleiegAfahoRsrveeNowrIleNtaoaGgrdkeit,nhingeooinrndsetthrruistcotpiaorovndosuidccatr.risekfusl,ly
HWBpleiegAfahoRsrveeNowrIleNtaoaGgrdkeit,nhingeooinrndsetthrruistcotpiaorovndosuidccatr.risekfusl,ly CHAPRRCOETR W
Pure Sine Wave Inverter Charger
REMOTE
CODNRTYACT
NC
CAN
C
NO
NEGATIVE
CHC AC / INV
FAULT
L OUTPUNT
ON OFF
N INPUTL
HWBpleiegAfahoRsrveeNowrIleNtaoaGgrdkeit,nhingeooinrndsetthrruistcotpiaorovndosuidccatr.risekfusl,ly
HWBpleiegAfahoRsrveeNowrIleNtaoaGgrdkeit,nhingeooinrndsetthrruistcotpiaorovndosuidccatr.risekfusl,ly CHAPRRCOETR W
3. Install the Top Plate. Drive the two panel screws FORFNZLVHWR¿[WKHSODWH
Pure Sine W
58
Power on
Main Switch
Power on
:LUHG5HPRWH&RQWURO
$IWHULQVWDOODWLRQSRZHURQWKHEDWWHUDQGWKH$&LQSXWFRQQHFWHGWRWKHLQYHUWHUFKDUJHUWKHQ WXUQRQWKHLQYHUWHUFKDUJHU5(*29:,QYHUWHU&KDUJHUFDQEHSRZHUHGRQYLDWKH main switch or wired remote control.
NOTE
z %HIRUHWKHLQYHUWHUFKDUJHULVSRZHUHGRQHQVXUHWKDWWKHORDGLVWXUQHGR2WKHUZLVHWKH
LQYHUWHUFKDUJHUPDEHRYHUORDGHG
z
$IWHUWKHLQYHUWHUFKDUJHULVWXUQHGRQLWZLOOHQWHUWKHVHOIWHVWPRGH7KHEX]]HUZLOOVRXQG
IRUVHFRQGVDQGWKHIDQZLOOWXUQDXWRPDWLFDOODWWKHVDPHWLPH7KHVHOIWHVWWDNHVDERXW one
minute. After the self-test, the sound disappears, and the fan stops running.
Main Switch
ON OFF
ON OFF
CHC AC / INV
FAULT
Pure Sine Wave Inverter Charger
1. Press the main switch of the inverter charger to the “ON” position to power the inverter charger on.
HBpleiegAfahoRsrveeNoIwrlNetaoaGgrdkeit,nhingeooinrndsetthrruistcotpiaorovndosuidccatr.risekfusl,ly
INPUTBATT
OUTPUTBATT
100% 25%
BYPASS
LI CHARGING
AC / INV
CHC
FAULT
ON OFF
AC/INV
2. The screen lights up and displays the status after the
CHG
inverter charger is powered on. The AC/INV indicator will
OLJKWXSEDVHGRQWKHXVDJH
Pure Sine W
$IWHUWKHLQYHUWHUFKDUJHULVSURSHUOLQVWDOOHGDQGSRZHUHGRQWKHLQYHUWHUFKDUJHUZRUNV
HBpleiegAfahoRsrveeNoIwrlNetaoaGgrdkeit,nhingeooinrndsetthrruistcotpiaorovndosuidccatr.risekfusl,ly
normally when all of the following conditions are met: z
7KHEX]]HUULQJVIRUVHFRQGV z The fan operates with the sound z The screen lights
up z The indicator lights up
Please contact us through renogy.com/contact-us/.
59
Power on
Main Switch :LUHG5HPRWH&RQWURO
ON OFF
:LUHG5HPRWH&RQWURO
ON OFF
CHC AC / INV
FAULT
Pure Sine Wave Inverter Charger
1. If you use the wired remote control, please turn the main switch of the inverter charger to “OFF” ¿UVW
HBpleiegAfahoRsrveeNoIwrlNetaoaGgrdkeit,nhingeooinrndsetthrruistcotpiaorovndosuidccatr.risekfusl,ly
2. 3UHVVWKHEXWWRQRQWKHZLUHGUHPRWHFRQWURO
ON
ERR
RMS-P2
ON
ON
ERR
RMS-P2
INPUTBATT
OUTPUTBATT
100% 25%
BYPASS
LI CHARGING
AC / INV
CHC
FAULT
ON OFF
AC/INV
- CHG
Pure Sine W
After the inverter charger is powered on, the ON indicator of the wired remote control and the AC/INV indicator of the inverter charger will light XSEDVHGRQWKHXVDJH The LCD of the inverter charger lights up and displays the operation status.
$IWHUWKHLQYHUWHUFKDUJHULVSURSHUOLQVWDOOHGDQGSRZHUHGRQWKHLQYHUWHUFKDUJHUZRUNV normally when all of the following conditions are met:
z 7KHEX]]HUULQJVIRUVHFRQGV z The fan operates with the sound
z The screen lights up
z The indicator lights up
z The ON indicator of the wired remote control lights up
Please contact us through renogy.com/contact-us/.
60
Operation
LCD Button
Operation
Setting Battery Type
User Mode
LCD
You can view the current operation status and warning messages of the inverter
charger on the LCD.
KW
KW
VA
VA
%HzC
%
Hz
Icon
Function Description
Input Source Information
AC
Indicates the AC input.
INPUTBATT KW VA H%zC
,QGLFDWHVLQSXWYROWDJHLQSXWIUHTXHQFEDWWHUYROWDJHDQGFKDUJHU current.
&RQ¿JXUDWLRQ3URJUDPDQG)DXOW,QIRUPDWLRQ
Indicates setting programs.
Indicates the warning and fault codes.
Warning:
ERROR
ÀDVKLQJZLWKZDUQLQJFRGH
Fault:
ERROR lighting with fault code.
Output Information
OUTPUTBATTLOAD KW VA % Hz
,QGLFDWHVRXWSXWYROWDJHRXWSXWIUHTXHQFORDGSHUFHQWORDGLQ9$ load in Watt, and discharging current.
61
Operation
LCD Button Setting Battery Type
User Mode
Icon Battery Information
Function Description
CHARGING
,QGLFDWHVEDWWHUOHYHOEDQGLQ EDWWHUPRGHDQGFKDUJLQJVWDWXVLQOLQHPRGH
,Q$&PRGHWKH/&’GLVSODVWKHEDWWHUFKDUJLQJVWDWXV
Status
Battery voltage
LCD Display
Constant Current mode / Constant Voltage mode
< 12.0V 12.0V – 12.5V 12.5V – 13.0V
)RXUEDUVZLOOÀDVKLQWXUQ
%RWWRPEDUZLOOEHRQDQGWKHRWKHUWKUHH EDUVZLOOÀDVKLQWXUQ
%RWWRPWZREDUVZLOOEHRQDQGWKHRWKHU WZREDUVZLOOÀDVKLQWXUQ
13.0V
%RWWRPWKUHHEDUVZLOOEHRQDQGWKHWRS EDUZLOOÀDVK
)ORDWLQJPRGH%DWWHULHVDUHIXOOFKDUJHG
)RXUEDUVZLOOEHRQ
,QEDWWHUPRGHWKH/&’GLVSODVWKHEDWWHUFDSDFLW
Load Percentage
Battery Voltage
LCD Display
< 10.3V
/RDG!
10.3V – 10.8V 10.8V – 11.3V
11.3V
< 10.9V
/RDG
10.9V – 11.4V 11.4V – 11.9V
11.9V
62
Operation
LCD Button Setting Battery Type
User Mode
Icon Load Percentage
Function Description Battery Voltage
< 11.2V
LCD Display
/RDG
11.2V – 11.7V 11.7V – 12.2V
12.2V
Load Information
OVER LOAD
100%
Indicates overload.
,QGLFDWHVWKHORDGOHYHOEDQG
25%
Mode Operation Information Indicates the inverter charger is connected to the shore power.
BYPASS
,QGLFDWHVWKHORDGLVVXSSOLHGEWKHXWLOLWSRZHU
,QGLFDWHVWKHXWLOLWFKDUJHUFLUFXLWLVZRUNLQJ
,QGLFDWHVWKH’&$&LQYHUWHUFLUFXLWLVZRUNLQJ
,QGLFDWHVWKHDODUPRIWKHLQYHUWHUFKDUJHULVGLVDEOHG
63
Operation
LCD Button Setting Battery Type
User Mode
Button
<RXFDQWXUQWRWKHGLVSODSDJHVRUVHWSDUDPHWHUVRIWKHLQYHUWHUFKDUJHUZLWKWKHIRXUEXWWRQV
KW
KW
VA
VA
H%zC
% Hz
AC/INV CHG FAULT
([LWWKHVHWWLQJVDQGJREDFNWRWKHPHQX 0HQXNH 0HQXNH
1. /RQJSUHVVWKHEXWWRQWRHQWHUWKHSDUDPHWHUVHWWLQJPHQX 2.
6KRUWSUHVVWRFKDQJHFRQ¿UPVHWWLQJLQWKHSDUDPHWHUVHWWLQJPHQX
64
Operation
LCD Button Setting Battery Type
User Mode
Setting Battery Type
6HWWKHEDWWHUWSHLPPHGLDWHODIWHUWKHLQYHUWHUFKDUJHULVSRZHUHGRQ5HIHUWRWKH VSHFL¿FDWLRQVSURYLGHGEWKHEDWWHUPDQXIDFWXUHUZKHQFKRRVLQJDSUHVHWEDWWHU’DPDJH FDXVHGELQFRUUHFWEDWWHUWSHYRLGVZDUUDQW
1. Long press until the LCD enters setting mode.
V
V
AC/INV CHG FAULT
AC/INV CHG FAULT
2. Press or to display Program 05.
AC/INV CHG FAULT
3. Press to enter 05 settings.
AC/INV CHG FAULT
65
Operation
LCD Button Setting Battery Type
User Mode
4. Press or DQGVHOHFWDEDWWHUWSHRQGHPDQGLQ DFFRUGDQFHWRWKHIROORZLQJWDEOH
AC/INV CHG FAULT
5. After selection, press to save settings.
AC/INV CHG FAULT
Program Code
Description
Parameter Setting
7SHRIEDWWHU User Mode
Boost Voltage Float Voltage
For accurate charging, connection to a temperature VHQVRULVUHTXLUHG
Gel 1 A.G.M.1
14.0V 14.1V
13.7V 13.4V
A.G.M.2
14.6V
13.7V
66
Operation
LCD Button Setting Battery Type
User Mode
Program Code
Description
Parameter Setting Sealed Lead Acid
Boost Voltage Float Voltage
14.4V
13.6V
Gel 2
14.4V
13.8V
Open Lead Acid / Flooded
For accurate charging, connection to a temperature VHQVRULVUHTXLUHG
Calcium
14.8V 15.1V
13.8V 13.6V
De-sulphation
15.5V for 4 hours
LI When the voltage reaches
14.2V, the charging will stop.
NOTE
z The voltage of lithium charging is preset to 14.7V. When the charging
voltage reaches the preset threshold 14.7V, the inverter charger stops
charging. It resumes charging when the FKDUJLQJYROWDJHGURSVEHORZ9
z ,IWKHSUHVHWEDWWHUSDUDPHWHUVDUHQRWFRPSDWLEOHZLWKRXUVVWHPRXFDQVHWWKHEDWWHU
WSHWREWRHQWHUWKH8VHUPRGH<RXFDQDOVRXVHWKH’&+RPHDSSWRFXVWRPL]HWKH parameters.
For details, see User ModeEHORZ
67
Operation
LCD Button Setting Battery Type
User Mode
User Mode
WARNING
z 5HDGWKHXVHUPDQXDORIWKHEDWWHUZKHQFXVWRPL]LQJDSUHVHWEDWWHU,QFRUUHFWEDWWHU type selection damages the inverter charger and voids the warranty.
V
V
1. Long press until the LCD enters the setting mode.
AC/INV CHG FAULT
AC/INV CHG FAULT
2. Press or until the LCD enters Program 05.
AC/INV CHG FAULT
3. Press to enter 05 settings.
AC/INV CHG FAULT
68
Operation
LCD Button Setting Battery Type
User Mode
4. Press or to select
AC/INV CHG FAULT
AC/INV CHG FAULT
5. After selection, press to save settings.
%GHIDXOWWKLVLQYHUWHUFKDUJHULVSUHVHWWR%RRVWDW9 and Float at 13.7V.
V
V
AC/INV CHG FAULT
AC/INV CHG FAULT
6. Long press until the LCD enters the setting mode.
AC/INV CHG FAULT
7. Press or to enter Program 94.
<RXFDQVHWWKHEDWWHUWSHLQWKHXVHUPRGHLQ3URJUDP 94.
69
Operation
LCD Button Setting Battery Type
User Mode
8. Press to enter 94 settings.
AC/INV CHG FAULT
Lithium Battery
AC/INV CHG FAULT
Non-lithium Battery
AC/INV CHG FAULT
9. Press or to select or according to
WKHEDWWHUWSH
10. After selection, Press to save settings.
AC/INV CHG FAULT
V
V
AC/INV CHG FAULT
AC/INV CHG FAULT
11. Long press until the LCD enters the setting mode.
70
Operation
LCD Button Setting Battery Type
User Mode
12. Press or to enter Program 26.
BATT V
AC/INV CHG FAULT
BATT V
AC/INV CHG FAULT
13. Press to enter 26 settings.
Maximum Charging Voltage Bulk Charging Voltage
BATT V
BATT V
14. )RUOLWKLXPEDWWHUVHWWKH maximum charging voltage in Program 26.
AC/INV CHG FAULT
AC/INV CHG FAULT
)RUQRQOLWKLXPEDWWHUVHW WKHEXONFKDUJLQJYROWDJH (C.V voltage) in Program
26.
:KHQWKHEDWWHUYROWDJH reaches the preset value, the inverter charger will VWRSFKDUJLQJWKHEDWWHU
15. Press or to set the voltage.
BATT
)RUOLWKLXPEDWWHUVHWWKHYROWDJHIURP9WR9)RU
V
QRQOLWKLXPEDWWHUVHWWKHYROWDJHIURP9WR9
BATT
AC/INV CHG FAULT
V
71
Operation
LCD Button Setting Battery Type
User Mode
16. After selection, press to save settings.
BATT V
AC/INV CHG FAULT
V
V
AC/INV CHG FAULT
AC/INV CHG FAULT
17. Long press until the LCD enters the setting mode.
BATT V
AC/INV CHG FAULT
18. Press or to enter Program 27.
BATT V
AC/INV CHG FAULT
19. Press to enter 27 settings.
72
Operation
LCD Button Setting Battery Type
User Mode
Battery Low Voltage Open Charging
BATT V
AC/INV CHG FAULT
BATT V
BATT
AC/INV CHG FAULT
V
Floating Charging Voltage
BATT V
AC/INV CHG FAULT
20. )RUOLWKLXPEDWWHUVHWWKH EDWWHUORZYROWDJHRSHQ charging in Program 27.
)RUQRQOLWKLXPEDWWHU VHWWKHÀRDWLQJFKDUJLQJ voltage in Program 27.
:KHQWKHEDWWHUYROWDJH is lower than the preset value, the inverter charger
VWDUWVWRFKDUJHWKHEDWWHU XQWLOWKHEDWWHUYROWDJH reaches the preset value of
Program 26.
21. Press or to set the voltage.
)RUOLWKLXPEDWWHUVHWWKHYROWDJHIURP9WR9)RU QRQOLWKLXPEDWWHUVHWWKHYROWDJHIURP9WR9
BATT V
AC/INV CHG FAULT
22. After selection, Press to save settings.
73
:RUNLQJ
:RUNLQJ
5(*29:,QYHUWHU&KDUJHUFRPELQHVDQLQYHUWHUFKDUJHUZLWKDQDXWRPDWLFWUDQVIHU
VZLWFKLQWRRQHFRPSOHWHVVWHP)HDWXULQJDWKUHHVWDJHEDWWHUFKDUJLQJPRGHZKHQ connected
to the utility AC input, the inverter charger can meet powerful needs as well
as
FKDUJHRXUEDWWHUEDQN$VDSRZHUVXSSOLWLVFDSDEOHRISURGXFLQJFOHDQHUVPRRWKHUDQG
PRUHUHOLDEOHHOHFWULFLWWRDGGUHVVRXUGLYHUVHQHHGV
7KHLQYHUWHUFKDUJHULVHTXLSSHGZLWKD$WUDQVIHUUHODVZLWFKWKDWVZLWFKHVEHWZHHQWKH FKDUJLQJDQGWKHVWDQGEPRGHGHSHQGLQJRQDYDLODELOLWRI$&LQSXW,I$&LVSUHVHQWWKH WUDQVIHUUHODESDVVHVXSWR$RIWKHLQFRPLQJ$&LQSXWWKURXJKWKHLQYHUWHUWRSRZHUWKH$& loads on the inverter’sRXWSXW6LPXOWDQHRXVOWKHLQYHUWHUFKDUJHUFKDUJHVWKHEDWWHUXSWR $PSV,QWKHHYHQWWKDWFKDUJHUFKDUJHVWKHEDWWHUXSWR$PSVZLOOSRZHUWKHORDGVWKURXJK WKHEDWWHUEDQN
ON
ON
ERR
RMS-P2
INPUTBATT
OUTPUTBATT
100% 25%
BYPASS
LI CHARGING
AC / INV
CHC
FAULT
ON OFF
AC/INV
- CHG
Pure Sine W
The ON indicator of the wired remote control and the AC/INV indicator of WKHLQYHUWHUFKDUJHUÀDVK green when the inverter charger is powering loads IURPWKHEDWWHU
ON
AC/INV
INPUTBATT
OUTPUTBATT
100% 25%
BYPASS
LI CHARGING
AC / INV
CHC
FAULT
ON OFF
ON
ERR
RMS-P2
AC/INV CHGAC/INV CHG FAUL 2. The ON indicator of the wired remote control and
the AC/INV indicator of the Pure Sine W inverter charger are solid
INPUTBATT
OUTPUTBATT
100% 25%
BYPASS
LI CHARGING
AC / INV
CHC
FAULT
green when the inverter charger is powering the loads through an AC Input
ON OFF
Source, and when the
inverter charger starts
WRFKDUJHWKHEDWWHUDW
the same time. The CHG
LQGLFDWRUÀDVKHVJUHHQ
3. :KHQWKHEDWWHULVIXOOFKDUJHGWKH&+*LQGLFDWRULVVROLG
CHG FAUL
green.
Pure Sine Wave Inverter Charger
ARNING
74
:RUNLQJ
CAUTION
z ,IWKH$&,19LQGLFDWRUDQG&+*LQGLFDWRUGRQRWOLJKWXSDVGHVFULEHGLQWKLVXVHUPDQXDO EXWWKHSRZHUVXSSOHTXLSPHQWEDWWHULHVDQG$&LQSXWVRXUFHLVRSHUDWLQJQRUPDOOWKH LQYHUWHUFKDUJHUQHHGVWURXEOHVKRRWLQJ3OHDVHFRQWDFWRXUFXVWRPHUVHUYLFHWKURXJKrenogy. com/contact-us/.
CHG FAULT
INPUTBATT
OUTPUTBATT
100% 25%
BYPASS
LI CHARGING
AC / INV
CHC
FAULT
Pure Sine Wave Inverter Charger
ERR
4. Under normal conditions,
FAULT indicator of the
inverter charger and the
ERR indicator of the wired
ON
ERR
remote control will not light
up.
RMS-P2
ON OFF
CHG FAULT
INPUTBATT
OUTPUTBATT
100% 25%
BYPASS
LI CHARGING
AC / INV
CHC
FAULT
ON OFF
Pure Sine Wave Inverter Charger
ERR
CHG FAULT
INPUTBATT
OUTPUTBATT
100% 25%
BYPASS
LI CHARGING
AC / INV
CHC
FAULT
ON OFF
Pure Sine Wave Inverter Charger
ERR
5. ,IERWKWKH)$8/7DQG
(55LQGLFDWRUVÀDVKUHG
DQGWKHEX]]HUVRXQGV
at the same time (0.5s),
ON
ERR
it means warnings are
SURYLGHGEWKHLQYHUWHU
RMS-P2
charger. For details, refer
to Warning/Fault Codes in
this user manual.
6. ,IERWKWKH)$8/7DQG
ERR indicators are always
LQUHGDQGWKHEX]]HU
sounds long, it means
ON
ERR
that the inverter charger
QHHGVWURXEOHVKRRWLQJ)RU
RMS-P2
details, refer to Warning/
Fault Codes in this
user manual. For more
technical instructions,
contact our customer
service through renogy.
com/contact-us/.
75
:RUNLQJ/RJLF
Power Supply Logic Charging Logic
:RUNLQJ/RJLF
Heat Dissipation Logic
Power Supply Logic
Battery Voltage
AC Input
Power Supply Equipment
10.5V to 16V (±0.3V) 10.5V (±0.3V)
OFF OFF
%DWWHU
ON
AC Input
,IWKHLQYHUWHUFKDUJHULVFRQQHFWHGWRWKHEDWWHURUWKH$&LQSXWLVSRZHUHGRWKHEDWWHU
VWDUWVWRVXSSOSRZHUWRWKHORDGZKHQWKHEDWWHUYROWDJHUDQJHVIURP9WR9±0.3V). If
WKHEDWWHUYROWDJHLVOHVVWKDQ9±9WKHEDWWHUVWRSVVXSSOLQJSRZHUWRWKHORDG
,IWKHLQYHUWHUFKDUJHUKDVEHHQFRQQHFWHGWRWKH$&LQSXWDQGLVLQWKHSRZHUVXSSOVWDWHWKH
AC input starts to supply power to the load.
CAUTION
z You can set the output priority in Program 01. For details, refer to Program
Codes in this user manual.
Charging Logic
:RUNLQJFRQGLWLRQV
If the inverter charger is connected to the AC input and is in the power
supply state, the inverter
FKDUJHUZLOODXWRPDWLFDOOUHFRJQL]HWKHEDWWHUYROWDJHDQGFKDUJHWKHEDWWHU
Battery Voltage Less than the preset value (TXDOWRRUJUHDWHUWKDQWKHSUHVHWYDOXH
Charging Status Start charging Stop charging
CAUTION
z 7KHSUHVHWYDOXHYDULHVDFFRUGLQJWREDWWHUWSHV)RUGHWDLOVUHIHUWR6HWWLQJ%DWWHU7SH
in this manual.
76
:RUNLQJ/RJLF
Power Supply Logic Charging Logic
Heat Dissipation Logic
Battery Charging Stages
Volts
15
14.5
1
14
13.5
13 12.5
1
12
11.5
11
10.5
Adjustable Time Depending on Battery Bank Size
3
Float 13.5v
2
Charging Current %
100
2
Time
50
4
3
40
Full Current Available on Float for on Board Supply in Power Pack Mode
The New Battery Chargers And Boosters Offer The Fastest Charge Rate Currently Available
Step 1 = Constant Current Charge Step 3 = Constant Voltage at 13.5V
Step 2 = Absorption Charge at 14.4V/14.8V Step 4 = Low Voltage Reset to Step 1
Bulk
Stage7KHFKDUJHUZLOOVXSSOFRQVWDQWFXUUHQWXQWLOWKHEDWWHUYROWDJHUHDFKHVWKHERRVW
YROWDJH7KHVRIWZDUHZLOOFDOFXODWHWKHWLPHWRVWDUWFKDUJLQJXQWLOWKHEDWWHUYROWDJHGURSV
EHORZWKHERRVWYROWDJHRI97KLVWLPHLVUHIHUUHGDV77[ 7
Boost Stage: The charger will supply constant voltage and reduce the current
slowly through this stage. The charger will stay in this stage until T1 has
run out. After this time the charger will
HQWHUWKHÀRDWVWDJH7KLVVWDJHZLOOODVWEHWZHHQKRXUDQGKRXUVGHSHQGLQJRQ7
NOTE
z 7KHVWDJHLVGHWHUPLQHGELQWHUQDOVRIWZDUHLQWKHLQYHUWHUFKDUJHU
Float
Stage’XULQJWKLVVWDJHWKHFKDUJHUZLOOVXSSODFRQVWDQWYROWDJHZKLFKLVGHWHUPLQHGE
WKHEDWWHUVHOHFWHGDQGZLOONHHSFXUUHQWDWDPLQLPXP7KLVVWDJHDFWVDVDWULFNOHFKDUJHU
Equalization7KLVVWDJHLVRQODYDLODEOHIRUEDWWHULHVZLWKHTXDOL]DWLRQVXFKDVÀRRGHG’XULQJ
WKLVVWDJHWKHEDWWHULHVDUHFKDUJHGDWDKLJKHUYROWDJHWKDQQRUPDODQGIRUPRVWEDWWHULHVWKLV
FRXOGFDXVHGDPDJH5HIHUWRWKHXVHUPDQXDORIWKHEDWWHURUFRQWDFWWKHPDQXIDFWXUHUWRVHH
if this stage is needed.
77
:RUNLQJ/RJLF
Power Supply Logic Charging Logic
Heat Dissipation Logic
Heat Dissipation Logic
7KHLQYHUWHUFKDUJHUXVHVWKHIDQIRUKHDWGLVVLSDWLRQ7KHZRUNLQJORJLFRIWKHIDQLVDVIROORZV
Inverter Charger :RUNLQJSURSHUO AC output current
Charging Current
Temperature
Fan
7KHIDQZRUNVIRUPLQXWHHYHUPLQXWHV
:KHQ$&RXWSXWFXUUHQWRIUDWHGFXUUHQWRIWKH$&ORDG WKHIDQVWDUWVZRUNLQJ
:KHQ$&RXWSXWFXUUHQWRIUDWHGFXUUHQWRIWKH$&ORDG WKHIDQVWRSVZRUNLQJ
:KHQFKDUJLQJFXUUHQW$WKHIDQVWDUWVZRUNLQJ :KHQFKDUJLQJFXUUHQW$WKHIDQVWRSVZRUNLQJ
:KHQWKHWHPSHUDWXUHRIWKHLQYHUWHUFKDUJHU°C, the fan VWDUWVZRUNLQJ When the
temperature of the inverter charger < 50°C, the fan VWRSVZRUNLQJ
78
3RZHUR
Main Switch
3RZHUR
:LUHG5HPRWH&RQWURO
Main Switch
ON OFF
ON OFF
CHC AC / INV
FAULT
HBpleiegAfahoRsrveeNoIwrlNetaoaGgrdkeit,nhingeooinrndsetthrruistcotpiaorovndosuidccatr.risekfusl,ly
Pure Sine Wave Inverter Charger
1. Press the main switch of the inverter charger to 2))WRWXUQLWR
2. The LCD and the LED indicators go out when the inverter FKDUJHULVSRZHUHGR
ON OFF
CHC AC / INV
FAULT
:LUHG5HPRWH&RQWURO
1. :KHQXVLQJDZLUHGUHPRWHFRQWUROSUHVVWKHEXWWRQRQWKH
ZLUHGUHPRWHFRQWUROWRWXUQRWKHSRZHU
ON
ERR
RMS-P2
79
3RZHUR
Main Switch :LUHG5HPRWH&RQWURO
ON
ERR
RMS-P2
ON OFF
CHC AC / INV
FAULT
2. The LCD and LED indicators of the inverter charger as well as the ON indicator of the wired UHPRWHFRQWUROJRRZKHQ the inverter charger is SRZHUHGR
80
Overcurrent Protection
Overcurrent Protection
7KHLQYHUWHUFKDUJHULVLQWHJUDWHGZLWKWZRFLUFXLWEUHDNHUVZKLFKHQVXUHWKDWWKHLQYHUWHU
FKDUJHUNHHSVRSHUDWLQJHYHQZKHQWKHLQSXWRXWSXWVWRSVZRUNLQJ:KHQWKHLQSXWRXWSXW
FLUFXLWEUHDNHULVDFWLYDWHGDPDQXDOUHVHWLVUHTXLUHGWRUHVXPHRSHUDWLRQ
WARNING
z 5LVNRIHOHFWULFVKRFN7XUQRWKHLQYHUWHUFKDUJHUDQGWKHSRZHUGHYLFHVFRQQHFWHGWRLW
ZKHQWKHFLUFXLWEUHDNHULVUHVHW
z
:HDUSURSHUSURWHFWLYHHTXLSPHQWDQGXVHLQVXODWHGWRROVGXULQJRSHUDWLRQ%HFDUHIXOZKHQ
WRXFKLQJEDUHWHUPLQDOVRIFDSDFLWRUVDVWKHPDUHWDLQKLJKOHWKDOYROWDJHVHYHQDIWHUWKH
power is removed.
REMOTE
CODNRTYACT
NC
CAN
C
NO
NEGATIVE
CHC AC / INV
FAULT
L OUTPUNT
ON OFF
N INPUTL
HWBpleiegAfahoRsrveeNowrIleNtaoaGgrdkeit,nhingeooinrndsetthrruistcotpiaorovndosuidccatr.risekfusl,ly
HWBpleiegAfahoRsrveeNowrIleNtaoaGgrdkeit,nhingeooinrndsetthrruistcotpiaorovndosuidccatr.risekfusl,ly CHAPRRCOETR W
REMOTE
CODNRTYACT
NC
CAN
C
NO
NEGATIVE
CHC AC / INV
FAULT
L OUTPUNT
ON OFF
N INPUTL
HWBpleiegAfahoRsrveeNowrIleNtaoaGgrdkeit,nhingeooinrndsetthrruistcotpiaorovndosuidccatr.risekfusl,ly
HWBpleiegAfahoRsrveeNowrIleNtaoaGgrdkeit,nhingeooinrndsetthrruistcotpiaorovndosuidccatr.risekfusl,ly CHAPRRCOETR W
- Pure Sine Wave Inverter Charger
Turn the two upper panel VFUHZVFRXQWHUFORFNZLVH EKDQGRUD3KLOOLSV screwdriver,
and remove
the Top Plate.
CHAPRRGOETRECINTPUT
FAULT
2. When the AC input current exceeds 40A, the ,QSXW&LUFXLW%UHDNHUZLOO automatically pop out. Press the CHARGER ,13873527(&7EXWWRQ WRUHVHWWKHFLUFXLWEUHDNHU
BefplIoerH Niaegs VhewW E PorvAr Re RokliRat Tn OdaN C EIgt TgHh ReNo E, Pei AnGi Cn O Rt Rn Tho Uis Or Gts Tr Td Eupe P Ercr Rti Uot CIdo T T Nnuasc Ptv.co Uiard Terfisullksy, BefploerHiaesgweh WorvAreokliRatndNaIgtghNeo,einGintnhoisrtsrdupercrtoitdounacstv.coiarderfisullkys,
CHG
AC/INV
ON OFF
INVEPRRTOETRECOTUTPUT
FAULT
CHG
AC/INV
3. When the AC output current exceeds 30A, the 2XWSXW&LUFXLW%UHDNHU will automatically pop out. Press the INVERTER OUTPUT PROTECT EXWWRQWRUHVHWWKHFLUFXLW EUHDNHU
BefplIoerH Niaegs VehwW E PorvAr Re RokliRat Tn OdaN C EIgt TgHh ReNo E, Pei AnGi Cn O Rt Rn Tho Uis Or Gts Tr Td Eupe P Ercr Rti Uot CIdo T T Nnuasc Ptv.co Uiard Terfisullkys, BefploerHiaesgweh WorvAreokliRatndNaIgtghNeo,einGintnhoisrtsrdupercrtoitdounacstv.coiarderfisullkys,
ON OFF
NOTE z $IWHUUHVHWWLQJLQVWDOOWKH7RS3ODWHEDFNWRWKHLQYHUWHUFKDUJHU
81
LED Indicators
Indicator of the Inverter Charger
LED Indicators
,QGLFDWRURIWKH:LUHG5HPRWH&RQWURO
Indicator of the Inverter Charger
LED Indicator Solid
AC/INV
Green
Flashing
Parameter 2XWSXWLVSRZHUHGEDQ$&VRXUFHLQOLQHPRGH
2XWSXWLVSRZHUHGEEDWWHURULQLQYHUWPRGH
CHG
Green
Solid
%DWWHULVIXOOFKDUJHG
Flashing
%DWWHULVEHLQJFKDUJHG
Solid
Fault For details, read Warning/Fault Codes in the user
FAULT
manual.
Red
Flashing Warning
For details, read Warning/Fault Codes in the user manual.
,QGLFDWRURIWKH:LUHG5HPRWH&RQWURO
LED Indicator
Parameter
Solid
2XWSXWLVSRZHUHGEDQ$&VRXUFHLQOLQHPRGH
ON
Green
Flashing
2XWSXWLVSRZHUHGEEDWWHURULQLQYHUWPRGH
ERR
Solid
Fault
Red
Flashing
Warning
82
Program Codes
Program Codes
7KHLQYHUWHUFKDUJHULVIXOOSURJUDPPDEOH<RXPDFKDQJHWKHUHVSHFWLYHSDUDPHWHUEJRLQJ
WRWKH3URJUDP&RGHOLVWHGEHORZ Operation Methods (1). Long press until the LCD
enters the setting mode. (2). Press or to select programs. (3). Press to enter
settings. (4). Press or to set parameters. (5). Press to save settings.
NOTE
z 5HVWDUWLQJWKHLQYHUWHUFRQWUROOHULVUHTXLUHGLIFKDQJHVDUHPDGHWRIUHTXHQFRXWSXW
voltage, charging current, and AC input voltage.
Setting Programs:
Icon
Description
Details
Exit setting mode
Escape
8WLOLW3ULRULWDQG%DWWHU3ULRULW
Utility Priority
The default setting is Utility Priority (Ut1). Under this setting, once the
inverter charger is connected to the utility power, it will power the loads
using the electricity from shore supply. The
LQYHUWHUFKDUJHUZLOOVWDUWFKDUJLQJWKHEDWWHUEDQNXVLQJWKH$&VRXUFHLIQHFHVVDU,QFDVHRI
SRZHURXWDJHWKHVVWHPDXWRPDWLFDOOVZLWFKHVWREDWWHUSRZHUHGPRGH
Battery Priority
7KHRSWLRQDOVHWWLQJLV%DWWHU3ULRULW6E88QGHUWKLVVHWWLQJWKHLQYHUWHUFKDUJHUZLOOSURYLGH
SRZHUXVLQJWKHFRQQHFWHGEDWWHUEDQNHYHQZKHQLWGHWHFWVDQ$&VRXUFH:KHQWKHEDWWHU
voltage reaches the low voltage setting point in Program 12, the inverter
charger will power the
ORDGVXVLQJWKHFRQQHFWHG$&VRXUFHEXWZLOOQRWFKDUJHWKHEDWWHUEDQN
Detailed settings of Program 01 are as follows:
Icon
Description
Utility Priority
Output source priority for the load %DWWHUSULRULW
Details
Utility is the preferred power source IRUORDGV%DWWHUZLOOSURYLGHSRZHUWR the
loads only when utility power is not DYDLODEOH
%DWWHULVWKHSUHIHUUHGSRZHUVRXUFHIRU loads. Utility provides power to the loads
RQOZKHQEDWWHUYROWDJHGURSVWRHLWKHU low-level warning voltage or the setting
point in Program 12.
83
Program Codes
NOTE
z $IWHUVHWWLQJVGLVFRQQHFWWKHLQYHUWHUFKDUJHUIURPWKH$&VRXUFHVKRUHSRZHU7XUQRWKH
LQYHUWHUFKDUJHUDQGZDLWIRUVHFRQGV7XUQLWRQDQGVHWWLQJVZLOOWDNHHHFW
$&,QSXW9ROWDJH5DQJH
%GHIDXOWWKHLQYHUWHUFKDUJHULVVHWWRDQDUURZLQSXWYROWDJHUDQJHIRUZKLFKWKHLQYHUWHU
FKDUJHUZLOOZRUNLQ8WLOLWPRGH,WLVUHFRPPHQGHGWRNHHSLQWKLVPRGHLIFRQQHFWLQJWKH
inverter charger to sensitive electronic devices such as computers and TVs as
the narrow mode UHGXFHVWKHVZLWFKLQJWLPHIURPH[WHUQDOSRZHUWREDWWHU
6HOHFWLQJDZLGHLQSXWYROWDJHUDQJHLVUHFRPPHQGHGZKHQRXQHHGSRZHUDQGPLJKWEH
UXQQLQJDJHQHUDWRUDVWKHWHQGWRKDYHZLGHUWROHUDQFHIRUDGLVWXUEHGZDYHIRUPRUDUHKDYLQJ
LVVXHVZLWKWKHVWDELOLWRIWKHPDLQXWLOLWOLQH7KLVZLOOKDYHDZLGHUUDQJHWRSUHYHQWVZLWFKLQJ
WREDFNXSEDWWHUPRGHLIXWLOLWSRZHULVZLWKLQWKHZLGHUUDQJH
Icon
Description
Details
Input voltage range
Wide 8WLOLWHHFWLYHUDQJH1RPLQDORXWSXW YROWDJHWR
Narrow (default) 8WLOLWHHFWLYHUDQJH1RPLQDORXWSXW YROWDJHWR
3RZHU6DYLQJ0RGH
3RZHUVDYLQJLVGHVLJQHGWRFRQVHUYHEDWWHUSRZHUZKHQ$&LQSXWLVQRWRUUDUHOUHTXLUHGE
WKHORDGV,QWKLVPRGHWKHLQYHUWHUFKDUJHUSXOVHVWKH$&RXWSXWORRNLQJIRUDQ$&ORDGLH
appliance). Whenever an AC load (greater than 50 watts) is turned on, the
inverter charger
UHFRJQL]HVWKHQHHGIRUSRZHUDQGDXWRPDWLFDOOVWDUWVLQYHUWLQJDQGWKHRXWSXWJRHVWRIXOO
voltage. When there is no load (or less than 50 watts) detected, the inverter
automatically
JRHVEDFNLQWRVHDUFKPRGHWRPLQLPL]HHQHUJFRQVXPSWLRQIURPWKHEDWWHUEDQN,Q3RZHU
Saving Mode, the inverter charger will draw power mainly in sensing moments,
thus the idle FRQVXPSWLRQLVVLJQL¿FDQWOUHGXFHG
Icon
Description
Details
Saving mode GLVDEOHGGHIDXOW
(QDEOHRUGLVDEOH power saving mode Saving mode
HQDEOHG
,IWKHSRZHUVDYLQJPRGHLVGLVDEOHG WKHRXWSXWRIWKHLQYHUWHUFKDUJHUZLOOEH
DYDLODEOHDWDOOWLPHV
,IWKHSRZHUVDYLQJPRGHLVHQDEOHG WKHRXWSXWRIWKHLQYHUWHUFKDUJHUZLOOEH
RXQWLODORDGJUHDWHUWKDQZDWWVLV detected.
6HWWLQJEDWWHU7SH For more instructions, read 6HWWLQJ%DWWHU7SH in the user
manual.
84
Program Codes
2XWSXW)UHTXHQF
7KHIDFWRUGHIDXOWIUHTXHQFIRUWKHLQYHUWHUFKDUJHULV+]1RUPDOOPDQXIDFWXUHUVEXLOG
HOHFWULFDOGHYLFHVIRUDFHUWDLQDPRXQWRI&XUUHQW9ROWDJHDQG+HUW]&FOHVDVVKRZQLQWKH
VSHFL¿FDWLRQV7KH&XUUHQWLVGHSHQGHQWRIWKH9ROWDJHDQGWKH+HUW]VXSSOLHGWRDQHOHFWULF
motor or appliance.
Icon
Description
Details
2XWSXWIUHTXHQF
+] +]GHIDXOW
0D[LPXP8WLOLW&KDUJLQJ
7KHLQYHUWHUFKDUJHUFDQRSHUDWHOLNHWKHEDWWHUFKDUJHUFRQYHUWLQJWKHLQFRPLQJ$&LQSXWLQWR
the DC recharging power.
Icon
Description
Details
Maximum utility charging current
The default is the maximum value (75A-3KW), with a 5A minimum.
/RZ%DWWHU9ROWDJH6HWSRLQW
7KHSXUSRVHRIWKLVVHWSRLQWLVWRSURWHFWWKHEDWWHULHVIURPEHLQJRYHUGLVFKDUJHG,WDVVXPHV
WKDW%DWWHU3ULRULWLVVHWRQ3URJUDP:KHQWKHEDWWHUYROWDJHUHDFKHVWKHSUHVHWYDOXH in
Program 12, the inverter charger will stop supplying power to loads. Once the
utility power is detected, the utility power/generator will supply power to
the loads.
Icon
Description
Details
/RZEDWWHUYROWDJH point when the power source switches from EDWWHUWRXWLOLW
BATT V
The range is from 10.5V to 12.5V. If the
EDWWHUYROWDJHLVEHORZWKLVVHWSRLQWQR SRZHULVJLYHQWRORDGVIURPWKHEDWWHU%
GHIDXOWWKLVLVWKHORZEDWWHUYROWDJHLQWKH FKDUJLQJWDEOHIRUDOOEDWWHULHV,QFUHPHQW of
each press is 0.1V for 12V.
2YHUYROWDJH%DWWHU5HFRYHU
7KLVVHWSRLQWLQGLFDWHVWKDWWKHYROWDJHUHWXUQVWRQRUPDOYDOXHZKHQDEDWWHUKDVEHHQ
RYHUFKDUJHGRULVRYHUWKHYROWDJHOLPLW7KHLQYHUWHUFKDUJHUZLOOEHLQDIDXOWVWDWHLIWKHEDWWHU
YROWDJHLVDERYHWKLVGHVLJQDWHGVHWSRLQWDQGUHVXPHQRUPDOEDWWHURSHUDWLRQZKHQUHDFKLQJ
this setpoint.
Icon
Description
Details
Threshold to trigger RYHUYROWDJHEDWWHU recovery
BATT
V
Range: 13.0V and 15.5V. Otherwise,
WKHRXWSXWRIESDVVUDQJHVIURP9 WR97KHYROWDJHLVVHWE\RXRQ demand. Increment of each
press is 0.1V.
85
Program Codes
.HVRXQGFRQWURO
,WLVXVHGWRFRQWUROWKHVRXQGRIWKHNH:KHQWKHNHLVRQLWFDQPDNHDVRXQGESUHVVLQJ
WKHNH:KHQLWLVRWKHUHLVQRVRXQGESUHVVLQJWKHNH
Icon
Description
Details
%HHSVZKLOH IXQFWLRQNHVDUH pressed
On 2
6FUHHQ0RGH
%GHIDXOWDIWHUPLQXWHRILQDFWLYLWWKHLQYHUWHUFKDUJHUZLOOUHWXUQWRWKHVFUHHQGLVSODHGDW
VWDUWXS<RXFDQFKDQJHWKLVPRGHWRFRQWLQXHYLHZLQJWKHODVWVFUHHQEHIRUHLQDFWLYLW
Icon
Description
Details
Auto return to default display screen
Return to default display screen (default)
The display screen will return to default screen (Input voltage / Output voltage) after 1 minute of inactivity.
Auto return to default display screen
Stay at latest screen
Display screen will stay on current screen until you change it.
/&’6FUHHQ0RGH
7KH/&’RQWKHLQYHUWHUFKDUJHUZLOODOZDVVWDRQEGHIDXOW<RXFDQFKDQJHWKHPRGHLQ Program
20.
Icon
Description
Details
LCD Screen Control
LCD screen will stay on (default) /&’VFUHHQZLOOWXUQRDIWHULQDFWLYLW
86
Program Codes
7KHPDLQVVZLWFKHVWRLQYHUWHUVRXQG When the switch is on and the inverter’s main input AC power is disconnected, the inverter will VRXQGDQDODUP:KHQWKHVZLWFKLVRQRPRUHDODUPVDUHUDLVHG
Icon
Description
Details
%HHSVZKLOH primary source is
interrupted
On 2
5HFRUG)DXOW&RGH The inverter charger will demonstrate the fault code.
Icon
Description
Details
Record Fault code
5HFRUGHQDEOHG 5HFRUGGLVDEOHGGHIDXOW
%RRVW&KDUJLQJ For more instructions, read 6HWWLQJ%DWWHU7SH in the user manual.
NOTE
7KLVVHWWLQJZLOOQRWEHPRGL¿DEOHLIRXFKRRVHDSUHVHWEDWWHUYROWDJH:KHQWKHYROWDJH reaches the preset voltage, the charging will stop.
Icon
Description
Details
%XONFKDUJLQJ voltage (C.V
voltage)
6HWWKHEXONFKDUJLQJYROWDJHDIWHUVHOHFWLQJWKHXVHUPRGHLQ
3URJUDP)RUQRQOLWKLXPEDWWHUVHWWKHYROWDJHIURP9 WR9%$77
BATT
V
Maximum charging voltage
Set the maximum charging voltage after selecting the user
PRGHLQ3URJUDP)RUOLWKLXPEDWWHUVHWWKHYROWDJHIURP 13.0V to 15.5V.
BATT
V
87
Program Codes
)ORDW&KDUJLQJ For more instructions, read 6HWWLQJ%DWWHU7SH in the user manual.
NOTE z 7KLVVHWWLQJZLOOQRWEHPRGL¿DEOHLIRXFKRRVHDSUHVHWEDWWHUYROWDJH
Icon
Description
Details
6HWWLQJ%DWWHU Type
6HWWKHÀRDWLQJFKDUJLQJYROWDJHDIWHUVHOHFWLQJWKHXVHUPRGH
LQ3URJUDP)RUQRQOLWKLXPEDWWHUVHWWKHYROWDJHIURP 9WR9%$77
BATT
V
/RZ’&&XWR9ROWDJH
7KLVSURJUDPGHWHUPLQHVWKHFXWRYROWDJHUDQJHIRUWKHEDWWHULQSXWRIWKHLQYHUWHUFKDUJHU
8SRQUHDFKLQJWKLVYROWDJHWKHLQYHUWHUFKDUJHUZLOOFXWRRSHUDWLRQXQWLOWKHEDWWHUFDQJR
DERYHWKLVYROWDJHOHYHO
NOTE z 7KLVVHWWLQJPXVWEHDWOHDVW9ORZHUWKDQWKH/RZ%DWWHU9ROWDJH$ODUPLQ3URJUDP
Icon
Description
Details
/RZ’&FXWR voltage
The default setting is 10.0V. Setting range is from 10.0V to 12.0V with
increments of 0.1V.
BATT
V
,QSXW)UHTXHQF5DQJH
7KHIDFWRUGHIDXOWIUHTXHQFIRULQYHUWHUVLV+]1RUPDOOPDQXIDFWXUHUVEXLOGHOHFWULFDO
GHYLFHVIRUDFHUWDLQDPRXQWRI&XUUHQW9ROWDJHDQG+HUW]&FOHVZKLFKLVPHQWLRQHGRQ
WKHQDPHSODWH7KH&XUUHQWLVGHSHQGHQWRIWKH9ROWDJHDQGWKH+HUW]VXSSOLHGWRDQHOHFWULF
PRWRURUDSSOLDQFH7KLVSURJUDPDOORZVRXWRVHWWKHIUHTXHQFUDQJHRIWKH$&LQSXWVRXUFH
6SHFLDOFDVHVPLJKWUHTXLUHDZLGHUIUHTXHQFUDQJHWKDQQRUPDOXWLOLWDQGJHQHUDWRURXWSXWV
Icon
Description
Details
6SHFLDO+]+]
)UHTXHQF5DQJH *HQHUDO+]+]+]+]+]+]
88
Program Codes
6HOHFWLRQRI%DWWHU7SH&XVWRP For more instructions, read 6HWWLQJ%DWWHU7SH in the user manual.
NOTE z 7KLVVHWWLQJZLOOQRWEHPRGL¿DEOHLIRXFKRRVHDSUHVHWEDWWHUYROWDJH
Icon
Description
Details
/LWKLXPEDWWHU
6HOHFWLRQRIEDWWHU
type
Non-lithium
EDWWHU
7KHEDWWHUFKDUJHYROWDJHDQGEDWWHUORZ RSHQFKDUJLQJFDQEHVHWXSLQ3URJUDP 26, 27
7KHEDWWHUFKDUJHYROWDJHFDQEHVHWXS in Program 26, 27
%DWWHU+LJK9ROWDJHIRU’U&RQWDFWV
The inverter charger have functions to automatically start and stop a
generator for supplementing charge. The auto generator feature starts the
generator with the use of Normally Closed (NC) contacts of the relay that
“opens” when the battery voltage drops to the programmed value of Program 96.
The Normally Open (NO) relay “closes”, and the generator
VWDUWVWRFKDUJHWKHEDWWHUEDQN:KHQWKHEDWWHULVUHFKDUJHGDQGLWVYROWDJHULVHVWRWKH
programmed value of Program 95, the NC (close) contacts and NO (open) contacts
of relay reset and the generator will stop / shut down the generator
automatically. The inverter charger ZLOOWKHQWUDQVIHUEDFNWR,QYHUWLQJ0RGH
Icon
Description
Details
7KHGUFRQWDFWVZLOOVZLWFKIURP12WR1&ZKHQWKHEDWWHU
voltage reaches the preset value in Program 95. This value
%DWWHUKLJKYROWDJH FDQQRWEHORZHUWKDQIDVWFKDUJHYROWDJH6HWWKHYROWDJHIURP
trip
13.0V to 15.5V.
BATT
V
89
Program Codes
/RZ9ROWDJH7ULSIRU’U&RQWDFWV
The inverter charger can automatically start and stop a generator for
supplementing charge. The auto generator feature starts the generator with the
use of Normally Closed (NC) contacts of the relay that “opens” when the
battery voltage drops to the programmed value of Program 96, Low Battery
Voltage Setpoint. The Normally Open (NO) relay “closes”, and the auto
generator start
IXQFWLRQHQDEOHVWKHJHQHUDWRUWRFKDUJHWKHEDWWHUEDQN:KHQWKHEDWWHULVUHFKDUJHGDQG
its voltage rises to the programmed value of Program 95, the NC (closes)
contacts and NO (open) contacts of relay reset. Dry contacts trigger when the
low voltage setpoint is reached and trigger
DJDLQZKHQXSSHUYROWDJHOLPLWLVUHDFKHGWRVWRS7KHLQYHUWHUFKDUJHUZLOOWKHQWUDQVIHUEDFNWR
Inverting Mode.
Icon
Description
Details
:KHQEDWWHUYROWDJHUHDFKHVWKHVHWSRLQWWKHGUFRQWDFW
VZLWFKHVIURP1&WR127KLVYDOXHFDQQRWEHORZHUWKDQWKH
%DWWHUORZYROWDJH FXWRSRLQWRIWKHORZEDWWHU7KHVHWWLQJUDQJHLVIURP9
trip
to 12.5V for 12V. Increment of each press is 0.1V for 12V.
BATT
V
‘U&RQWDFWV&RQWURO
7RPRGLIWKHVHWWLQJSRLQWRIEDWWHULQ3URJUDPDQG3URJUDPHQDEOHGUFRQWDFWFRQWURO This
allows control over the auto generator function.
Icon
Description
Details
,IWKHLQYHUWHUFKDUJHULVVHWLQGFGGUFRQWDFWGLVDEOHPRGH GUFRQWDFWIXQFWLRQLVGLVDEOHG:KHQWKLVVHWWLQJLVHQDEOHG the dry contacts voltages are set.
Dry contacts control ,IWKHLQYHUWHUFKDUJHULVVHWLQGFHGUFRQWDFWHQDEOHPRGH GUFRQWDFWIXQFWLRQLVHQDEOHGDQGFDQEHVHWXSLQ program.
90
Program Codes
/RZ%DWWHU9ROWDJH$ODUP
8VHUVFDQVHOHFWWRKDYHWKHLQYHUWHUFKDUJHUVRXQGDQDODUPDWDSURJUDPPDEOHEDWWHU
YROWDJH7KHYDOXHVHWLQ3URJUDPVKRXOGEHKLJKHUWKDQ3URJUDP/RZ’&&XWR
9ROWDJHDVLWZLOOZDUQXVHUVWKDWWKHEDWWHULVGLVFKDUJLQJEHIRUHXOWLPDWHOEHLQJGLVFRQQHFWHG
Icon
Description
Details
The default is 10.5V. The setting range is 10.5V to 12.5V with
DQLQFUHPHQWRI97KLVVHWWLQJZLOOEHDWOHDVW9JUHDWHU
/RZYROWDJHEDWWHU than setting Program 29.
alarm
BATT
V
$&RXWSXW9ROWDJH
$OORZVXVHUVWRFXVWRPL]H$&RXWSXWYROWDJHVIRUGHYLFHVWKDWPLJKWQHHGWRPHHWDYHU
VSHFL¿F$&LQSXWFULWHULD
91
:DUQLQJ)DXOW&RGHV
:DUQLQJ)DXOW&RGHV
:KHQWKHLQYHUWHUFKDUJHUQHHGVWURXEOHVKRRWLQJWKH)$8/7LQGLFDWRURIWKHLQYHUWHUFKDUJHU
DQGWKH(55LQGLFDWRURIWKHZLUHGUHPRWHFRQWURODUHÀDVKLQJUHGZKLOHWKHEX]]HUEHHSVORQJ
DQGWKH/&’GLVSODVWKH)$8/7FRGH7URXEOHVKRRWWSRDFFRUGLQJWRWKHIROORZLQJWDEOH
For more technical support, contact our custom service through renogy.com
/contact-us.
Icon
:DUQLQJ(YHQW
%DWWHURYHUYROWDJHDODUP
6KXWGRZQWKHLQYHUWHUFKDUJHU’LVFRQQHFWDOOFDEOHV&KHFNWKHEDWWHU
YROWDJH,IWKHEDWWHULVGDPDJHGUHSODFHLW
%DWWHUORZYROWDJHDODUP & KDUJHWKHEDWWHULPPHGLDWHO &
KHFNWKHEDWWHUYROWDJHWRFRQIRUPZKHWKHUWKHEDWWHULVGDPDJHG,I
WKHEDWWHULVGDPDJHGUHSODFHLW
05: Over-temperature alarm
& KHFNZKHWKHUIDQWKHUPDOFRQWUROLVEORFNHGDQGDHFWKHDWGLVVLSDWLRQ &
KHFNZKHWKHUWKHIDQVDUHUXQQLQJ,IWKHDUHQRWUXQQLQJWKHIDQV
QHHGWURXEOHVKRRWLQJ&RQWDFWRXUFXVWRPHUVHUYLFHWKURXJKrenogy.com/ contact-us/.
‘ HFUHDVHWKHDPELHQWWHPSHUDWXUHDQGWKHORDGSRZHU 4. Shut down the inverter
charger and restart it when its temperature
decreases.
07: Overload alarm 5HGXFHWKHTXDQWLWDQGSRZHURIWKHORDG
88: The inverter transformer is phased in reverse
6KXWGRZQWKHLQYHUWHUFKDUJHU’LVFRQQHFWWKH$&LQSXWDQGFKHFN whether the AC input
wiring is correct.
7KHIUHTXHQFRIPDLQSRZHULVRXWRIUDQJH
6KXWGRZQWKHLQYHUWHUFKDUJHU’LVFRQQHFWWKH$&LQSXWSRZHU&KHFNWKDW
WKH$&LQSXWLVZLWKLQWKHUDWHGIUHTXHQFUDQJHRI+]WR+]
:KHQWKHLQYHUWHUFKDUJHUQHHGVWURXEOHVKRRWLQJWKH)$8/7LQGLFDWRURIWKHLQYHUWHUFKDUJHU
DQGWKH(55LQGLFDWRURIWKHZLUHGUHPRWHFRQWURODUHVROLGUHGZKLOHWKHEX]]HUEHHSVORQJDQG
WKH/&’GLVSODVWKH)$8/7FRGH7URXEOHVKRRWIDOXWVDFFRUGLQJWRWKHIROORZLQJWDEOH
For more technical support, contact our custom service through renogy.com
/contact-us/.
Icon
ERROR
:DUQLQJ(YHQW
02: Short circuit of the inverter charger
6KXWGRZQWKHLQYHUWHUFKDUJHU&KHFNZKHWKHUWKHORDGLVVKRUWFLUFXLWHG,I it is, replace
the load and restart the inverter charger.
92
:DUQLQJ)DXOW&RGHV
Icon
ERROR ERROR
ERROR
ERROR ERROR ERROR
ERROR
:DUQLQJ(YHQW
%DWWHUKLJKYROWDJH 6KXWGRZQWKHLQYHUWHU’LVFRQQHFWDOOFDEOHVFRQQHFWHGWRLW&KHFNWKH
EDWWHUYROWDJH,IWKHEDWWHULVGDPDJHGUHSODFHLW
%DWWHUORZYROWDJH & KDUJHWKHEDWWHULPPHGLDWHO &
KHFNWKHEDWWHUYROWDJHWRFRQ¿UPZKHWKHUWKHEDWWHULVGDPDJHG,I
WKHEDWWHULVGDPDJHGUHSODFHLW
7KHKHDWVLQNRILQYHUWHUFKDUJHULVRYHUKHDWHG &
KHFNZKHWKHUIDQWKHUPDOFRQWUROLVEORFNHGDQGDHFWKHDWGLVVLSDWLRQ &
KHFNZKHWKHUWKHIDQVDUHUXQQLQJ,IWKHDUHQRWUXQQLQJWKHIDQV
QHHGWURXEOHVKRRWLQJ&RQWDFWRXUFXVWRPHUVHUYLFHWKURXJKrenogy.com/ contact-us/. ‘
HFUHDVHWKHDPELHQWWHPSHUDWXUHDQGWKHORDGSRZHU 4. Shut down the inverter charger
and restart it when its temperature decreases.
06: The output voltage of inverter charger is too high or too low Shut down
the inverter charger and restart it. If the fault still persists, contact our
custom service through renogy.com/contact-us/.
07: Inverter charger overloaded 5HGXFHWKHTXDQWLWDQGSRZHURIWKHORDG
98: The transformer of inverter charger is overheated &
KHFNZKHWKHUIDQWKHUPDOFRQWUROLVEORFNHGDQGDHFWKHDWGLVVLSDWLRQ &
KHFNZKHWKHUWKHIDQVDUHUXQQLQJ,IWKHDUHQRWUXQQLQJWKHIDQV
QHHGWURXEOHVKRRWLQJ&RQWDFWRXUFXVWRPHUVHUYLFHWKURXJKrenogy.com/ contact-us/. ‘
HFUHDVHWKHDPELHQWWHPSHUDWXUHDQGWKHORDGSRZHU 4. Shut down the inverter charger
and restart it when its temperature decreases.
99: Slow start failure of the inverter charger If the inverter fails to start
slowly, contact our custom service through renogy.com/contact-us/.
93
7HFKQLFDO6SHFL¿FDWLRQV
7HFKQLFDO6SHFL¿FDWLRQV
,QYHUWHU6SHFL¿FDWLRQV
Rated Output Power
3000W
6XUJH3RZHUVHFRQG
9000W
6XUJH3RZHUVHFRQGV
4500W
6XUJH3RZHUVHFRQGV
3600W
Nominal Output Voltage RMS
120V AC (100V to 120V AC, 5V intervals)
Outuput Frequency
+]±+]RU+]±+]
2XWSXW:DYH)RUP
Pure Sine Wave
Output Overload
/RDG (± )DXOW7XUQRRXWSXWDIWHUVHFRQGV
/RDG± )DXOW7XUQRRXWSXWDIWHUVHFRQGV
/RDG±
)DXOW7XUQRRXWSXWDIWHUVHFRQGV
Nominal Input Voltage
12V DC
Input Voltage Range
11V to 16V DC (±0.3V)
/RZ’&:DUQLQJ9ROWDJH
11V DC (±0.3V)
/RZ’&&XWR9ROWDJH
10.5V DC (±0.3V)
Short Circuit Protection
Software Protection
1RPLQDO(FLHQF
!3HDN
No Load Power Consumption
Normal: < 30W
Nominal Input Voltage Input Voltage Range Input Frequency Range ,QSXW:DYH)RUP
Power Factor 2SWLPDO(FLHQF Output Current
94
&KDUJHU6SHFL¿FDWLRQV 120V AC
90V to 138V AC Generator: 40 to 70 Hz; Utility: 50(±5) Hz or 60(±6) Hz
Sine Wave (Utility or Generator) 0.9 to 1 ! 5A to 75A
&RQ¿JXUDEOH$LQWHUYDOV
7HFKQLFDO6SHFL¿FDWLRQV
Short Circuit Protection
Output Overload
Overcharge Protection Shutdown
&KDUJHU6SHFL¿FDWLRQV &LUFXLW%UHDNHU
/RDG± )DXOW7XUQRRXWSXWDIWHUVHFRQGV
/RDG± )DXOW7XUQRRXWSXWDIWHUVHFRQG
16V for 12V DC
Transfer Time /LQH0RGH(FLHQF Transfer Relay Rating
7UDQVIHU6ZLWFK6SHFL¿FDWLRQV 10 ms !
$0D[LPXP%SDVV
*HQHUDO6SHFL¿FDWLRQV
Battery Types
Gel, AGM, SLA, Flooded, Calcium, Li, User Mode
Operating Temperature Range
-4°F to 104°F or -20°C to 40°C
Storage Temperature
-22°F to 158°F or -30°C to 70°C
Humidity
WR
Noise
G%
Dimensions
20.1 x 11.2 x 7.6 in / 510 x 285 x 193 mm
:HLJKW
OEV.J
&HUWL¿FDWLRQV
ETL listed to CSA Standard C22.2 No. 107.1 and UL458 with marine supplement
FCC part 15 Class A
List Dimensions :LUH/HQJWK
:LUHG5HPRWH&RQWURO 2.8 x 4.3 x 1.3 in / 70 x 110 x 31.8 mm Approx 16.4 ft
NOTE z 3URGXFWVSHFL¿FDWLRQVDUHVXEMHFWWRFKDQJHZLWKRXWIXUWKHUQRWLFH
95
Dimensions
Dimensions
12.99 in [330 mm]
0.35 in [9 mm]
8.89 in [266 mm]
Pure Sine Wave Inverter Charger
12.99 in [330 mm] 14.99 in [380.8 mm] 7.58 in [192.7 mm] 20.07 in [510 mm] NOTE z Dimension tolerance: ±0.2 in (0.5 mm)
0.28 in [7 mm] 9.76 in [248 mm] 0.51 in [13 mm] 11.22 in [285 mm]
96
Maintenance
Inspection
Maintenance
Cleaning
Storage
Inspection
)RURSWLPXPSHUIRUPDQFHLWLVUHFRPPHQGHGWRSHUIRUPWKHVHWDVNVUHJXODUO z Ensure the
inverter charger is installed in a clean, dry and ventilated area. z
(QVXUHWKHUHLVQRGDPDJHRUZHDURQWKHFDEOHV z
(QVXUHWKH¿UPQHVVRIWKHFRQQHFWRUVDQGFKHFNLIWKHUHDUHDQORRVHGDPDJHGRUEXUQW
connections. z
0DNHVXUHWKH$&,19LQGLFDWRU&+*LQGLFDWRUDQG)$8/7LQGLFDWRUDUHLQSURSHUFRQGLWLRQ z
(QVXUHWKHUHLVQRFRUURVLRQLQVXODWLRQGDPDJHRUGLVFRORUDWLRQPDUNVRIRYHUKHDWLQJRU
EXUQLQJ z If the inverter charger is dirty, use a damp cloth to clean the
outside of the device to prevent
GXVWDQGGLUWIURPDFFXPXODWLQJ%HIRUHWKHLQYHUWHUFKDUJHULVSRZHUHGRQPDNHVXUHLWLV
completely dry after cleaning. z 0DNHVXUHWKHYHQWLODWLRQKROHVDUHQRWEORFNHG
WARNING
z 5LVNRIHOHFWULFVKRFN0DNHVXUHWKDWDOOSRZHUVXSSOLHVDUHWXUQHGREHIRUHWRXFKLQJ
terminals on the inverter charger.
Cleaning
)ROORZWKHVWHSVEHORZWRFOHDQWKHLQYHUWHUFKDUJHUUHJXODUO z
‘LVFRQQHFWDOOFDEOHVFRQQHFWHGWRWKHLQYHUWHUFKDUJHU z
:HDUSURSHUSURWHFWLYHHTXLSPHQWDQGXVHLQVXODWHGWRROVGXULQJRSHUDWLRQ%HFDUHIXOZKHQ
WRXFKLQJEDUHWHUPLQDOVRIFDSDFLWRUVDVWKHPDUHWDLQKLJKOHWKDOYROWDJHVHYHQDIWHU
power is removed. z Wipe the housing of the inverter charger and connector
contacts with a dry cloth or
nonPHWDOOLFEUXVK,ILWLVVWLOOGLUW\RXFDQXVHKRXVHKROGFOHDQHUV z
0DNHVXUHWKHYHQWLODWLRQKROHVDUHQRWEORFNHG z
‘UWKHLQYHUWHUFKDUJHUZLWKDFOHDQFORWKDQGNHHSWKHDUHDDURXQGWKHLQYHUWHUFKDUJHU
clean and dry. z
0DNHVXUHWKHLQYHUWHUFKDUJHULVFRPSOHWHOGUEHIRUHUHFRQQHFWLQJLWWRWKHEDWWHUDQG$&
input.
Storage
)ROORZWKHWLSVEHORZWRHQVXUHWKDWWKHLQYHUWHUFKDUJHULVVWRUHGZHOO z
‘LVFRQQHFWDOOFDEOHVFRQQHFWHGWRWKHLQYHUWHUFKDUJHU z
%DSSOLQJGLHOHFWULFJUHDVHWRHDFKFRQQHFWRUFRQWDFWWKHGLHOHFWULFJUHDVHUHSHOV
moisture and protects the connector contacts from corrosion. z Store the
inverter charger in a well-ventilated, dry, and clean environment with the
temperature between -22°F to 158°F or -30°C to 70°C.
97
Emergency Responses
Fire Flooding
Emergency Responses
Smell
Noise
,QWKHHYHQWRIDQWKUHDWWRKHDOWKRUVDIHWDOZDVEHJLQZLWKWKHVWHSVEHORZEHIRUH
addressing other suggestions.
z ,PPHGLDWHOFRQWDFWWKH¿UHGHSDUWPHQWRURWKHUUHOHYDQWHPHUJHQFUHVSRQVHWHDP z
1RWLIDOOSHRSOHZKRPLJKWEHDHFWHGDQGHQVXUHWKDWWKHFDQHYDFXDWHWKHDUHD
WARNING z 2QOSHUIRUPWKHVXJJHVWHGDFWLRQVEHORZLILWLVVDIHWRGRVR
Fire
‘LVFRQQHFWDOOFDEOHVFRQQHFWHGWRWKHLQYHUWHUFKDUJHU
3XWRXWWKH¿UHZLWKD¿UHH[WLQJXLVKHU$FFHSWDEOH¿UHH[WLQJXLVKHUVLQFOXGHZDWHU&22, and
$%&
WARNING z ‘RQRWXVHWSH’ÀDPPDEOHPHWDO¿UHH[WLQJXLVKHUV
Flooding
,IWKHLQYHUWHUFKDUJHULVVXEPHUJHGLQZDWHUVWDDZDIURPWKHZDWHU
‘LVFRQQHFWDOOFDEOHVFRQQHFWHGWRWKHLQYHUWHUFKDUJHU
Smell
‘LVFRQQHFWDOOFDEOHVFRQQHFWHGWRWKHLQYHUWHUFKDUJHU 2. Ensure that nothing is in
contact with the inverter charger. 3. Ventilate the room.
Noise
‘LVFRQQHFWDOOFDEOHVFRQQHFWHGWRWKHLQYHUWHUFKDUJHU
0DNHVXUHQRIRUHLJQREMHFWVDUHVWXFNLQWKHIDQRIWKHLQYHUWHUFKDUJHURUWKHULQJWHUPLQDO
NOTE z 7KHQRUPDOQRLVHYDOXHRIWKHLQYHUWHUFKDUJHULVOHVVWKDQG%GXULQJRSHUDWLRQ
98
Technical Support
Technical Support
For additional support, contact the Renogy technical support team through
renogy.com/contactus+DYHWKHIROORZLQJLQIRUPDWLRQDYDLODEOHZKHQFRQWDFWLQJ5HQRJ z
Owner name z Contact information z 2UGHUQXPEHU z Purchase channel z
6HULDOQXPEHU z %ULHIGHVFULSWLRQRIWKHLVVXH
5HQRJRHUVSUHPLXPVHUYLFHVZRUOGZLGH
North America $VLD3DFL¿F Europe
US www.renogy.com UK XNUHQRJFRP AU au.renogy.com FR fr.renogy.com ES es.renogy.com
CN www.renogy.cn CA ca.renogy.com JP UHQRJMS DE de.renogy.com KR NUUHQRJFRP
99
FCC Statement
7KLVGHYLFHFRPSOLHVZLWK3DUWRIWKH)&&5XOHV)&&,’$13%560/3*2SHUDWLRQLV
VXEMHFWWRWKHIROORZLQJWZRFRQGLWLRQV (1) This device may not cause harmful
interference. (2) This device must accept any interference received, including
interference that may cause
undesired operation.
7KLVHTXLSPHQWKDVEHHQWHVWHGDQGIRXQGWRFRPSOZLWKWKHOLPLWVIRUD&ODVV$GLJLWDO
GHYLFHSXUVXDQWWR3DUWRIWKH)&&5XOHV7KHVHOLPLWVDUHGHVLJQHGWRSURYLGHUHDVRQDEOH
SURWHFWLRQDJDLQVWKDUPIXOLQWHUIHUHQFHLQDUHVLGHQWLDOLQVWDOODWLRQ7KLVHTXLSPHQWJHQHUDWHV
XVHVDQGFDQUDGLDWHUDGLRIUHTXHQFHQHUJDQGLIQRWLQVWDOOHGDQGXVHGLQDFFRUGDQFHZLWK
the instructions, may cause harmful interference to radio communications.
However, there is no
JXDUDQWHHWKDWLQWHUIHUHQFHZLOOQRWRFFXULQDSDUWLFXODULQVWDOODWLRQ,IWKLVHTXLSPHQWGRHVFDXVH
KDUPIXOLQWHUIHUHQFHWRUDGLRRUWHOHYLVLRQUHFHSWLRQZKLFKFDQEHGHWHUPLQHGEWXUQLQJWKH
HTXLSPHQWRDQGRQWKHXVHULVHQFRXUDJHGWRWUWRFRUUHFWWKHLQWHUIHUHQFHERQHRUPRUHRI the
following measures: (1) Orient or relocate the receiving antenna.
,QFUHDVHWKHVHSDUDWLRQEHWZHHQWKHHTXLSPHQWDQGUHFHLYHU
&RQQHFWWKHHTXLSPHQWLQWRDQRXWOHWRQDFLUFXLWGLHUHQWIURPWKDWWRZKLFKWKHUHFHLYHULV
connected. (4) Consult the dealer or an experienced radio/TV technician for
help.
FCC Radiation Exposure Statement
7KLVHTXLSPHQWFRPSOLHVZLWK)&&UDGLDWLRQH[SRVXUHOLPLWVVHWIRUWKIRUDQXQFRQWUROOHG
HQYLURQPHQW7KLVHTXLSPHQWVKRXOGEHLQVWDOOHGDQGRSHUDWHGZLWKPLQLPXPGLVWDQFHFP
EHWZHHQWKHUDGLDWRU RXUERG
100
RENOGY.COM
Visit renogy.com to find relevant documentation or get more support via
“Contact Us”. Renogy reserves the right to change the contents of this manual
without notice.
Join the Renogy Power Plus Community by downloading the DC Home App.
Find your e-warranty here, and more.
References
- Solar Power Kits & Equipment for Sale | Renogy Australia
- Renogy® Canada solar off-grid items, Canadian solar panels
- Renogy bietet alle Produkte für netzunabhängige Solarsysteme anRenogy DE
- Renogy® Official- offer all off grid solar system products
- Renogy® Official- offer all off grid solar system products
- Contact Us | Renogy Solar Panels & Complete Solar Kits
- Contact Us | Renogy Solar Panels & Complete Solar Kits
- RENOGY如果新能源 | 让每个人拥有独立清洁的能源
- Renogy® Official- offer all off grid solar system products
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>