RALPH LAUREN RL 4802 Allen Large Round Flush Mount Installation Guide
- June 4, 2024
- ralph lauren
Table of Contents
RL 4802 Allen Large Round Flush Mount
Installation Guide
ASSEMBLY INSTRUCTIONS
TO assemble safety cables:
- Join fixture safety cables with safety cables from the ceiling.
- Wrap both safety cables around the cable lock nut.
- Insert screws into both holes on the cable lock nut, and secure screws with a screwdriver.
- Push the cable lock nut into the outlet box.
NOTICE:
This light fixture should be installed in accordance with all applicable,
local installation codes, and by a person familiar with the construction and
operation of it, as well as the hazards involved. Inspect items and contents
carefully. If any damage or defect is found, do not install it.
Retain all packaging material until installation is complete and approved.
-
Carefully remove all parts from the box.
-
Remove the mounting plate (B) from the fixture body (E) by loosening nuts (F).
-
Affix mounting plate (B) onto the outlet box and secure with mounting screws (D).
-
Connect the hot wire (BLACK) from the fixture to the hot wire from the outlet box (usually BLACK). Fasten them together with a plastic wire connector (A) provided and wrap the connection with electrical tape.
-
Connect the neutral wire (WHITE) from the fixture to the wire from the outlet box (usually WHITE).
DO NOT REVERSE THE HOT AND NEUTRAL CONNECTIONS SAFETY WILL BE COMPROMISED. -
Connect the ground wire from the fixture (bare copper) to the ground wire from the outlet box (usually green or copper in color).
IT IS IMPERATIVE THAT THIS FIXTURE BE GROUNDED. -
Attach the fixture body (E) onto the mounting plate (B), let the rods (C) pass through the holes on the fixture body (E), and secure with nuts (F).
-
Insert bulbs (not included) into the socket.
-
Attach plastic washer (H), and diffuser (I) to the nipple (G) and secure with metal washer (J), and finial (K).
-
Installation is complete, turn on the power at the fuse or circuit breaker.
Care Instructions: Clean only with a soft dry cloth or feather duster. Do not use abrasive or chemical agents.