HINKLEY 28814 Wall Mount Interior Lighting Instruction Manual

June 13, 2024
HINKLEY

HINKLEY 28814 Wall Mount Interior Lighting

HINKLEY-28814-Wall-Mount-Interior-Lighting-product

Product Information

The HINKLEY Drawing 1 is a mounting fixture that is designed for both indoor and outdoor use. It comes with assembly instructions and is item number 28814. The fixture is manufactured by HINKLEY, located at 33000 Pin Oak Parkway Avon Lake, OH 44012. For any inquiries, you can contact HINKLEY at 800.446.5539 or 440.653.5500. More information can be found on their website at hinkley.com.

  • Safety Warning
    • Please read the wiring and grounding instructions provided in HINKLEY I.S. 18.
    • It is important to turn off the power supply during installation.
    • If new wiring is needed, it is recommended to consult a qualified electrician or local authorities to ensure compliance with code requirements.
  • Wiring Instructions for Indoor Fixtures
    • Connect the positive supply wire (A) to the positive fixture lead (B) using an appropriately sized twist-on connector. The positive supply wire is typically black or the smooth, unmarked side of the two-conductor cord.
    • Connect the negative supply wire (C) to the negative fixture lead (D). The negative supply wire is typically white or the ribbed, marked side of the two-conductor cord.
    • Refer to the grounding instructions below for completing all electrical connections.
  • Wiring Instructions for Outdoor Fixtures
    • Connect the positive supply wire (A) to the positive fixture lead (B) using an appropriately sized twist-on connector. The positive supply wire is typically black or the smooth, unmarked side of the two-conductor cord.
    • Connect the negative supply wire (C) to the negative fixture lead (D). The negative supply wire is typically white or the ribbed, marked side of the two-conductor cord.
    • Cover the open end of connectors with silicone sealant to create a watertight seal.
    • If installing a wall mount fixture, use caulk to seal gaps between the fixture mounting plate (backplate) and the wall. This helps prevent water from entering the outlet box. If the wall surface is lap siding, use caulk and a fixture mounting platform specially designed for this purpose.
    • Refer to the grounding instructions below for completing all electrical connections.

Grounding Instructions

For Flush Mount Fixtures:

  • Fasten the fixture ground wire (E), typically copper or green plastic coated, to the fixture mounting strap (M) using the ground screw (S). Refer to Drawing 1 for visual reference.

Note: On straps for screw-supported fixtures, first install the two mounting screws in the strap. Any remaining tapped hole may be used for the ground screw.

For Chain Hung Fixtures:

  • Loop the fixture ground wire (E), typically copper or green plastic coated, under the head of the ground screw (S) on the fixture mounting strap (M).
  • Connect the loose end of the fixture ground wire directly to the ground wire of the building system using appropriately sized twist-on connectors. Refer to Drawing 2 for visual reference

Assembly Instructions

start here

  1. Find a clear area in which you can work.
  2. Unpack fixture and glass from carton.
  3. Carefully review instructions prior to assembly.

DRAWING Mounting

DRAWING 1 – Mounting

DRAWING Installation

DRAWING 2-Cage Installation

  1. Release mounting plate (3) by removing the screws (2) on the side of the backplate (1)
  2. Use screws (4) (not provided) to secure mounting plate (3) to junction box (9)
  3. If needed use appropriate additional support (5) to support the mounting plate (3)
  4. Make wiring connections using IS-18
  5. Secure backplate (1) to mounting plate (3) using the previously removed screws (2)
  6. Lamp fixture using appropriate bulb (7)
  7. Secure cap (8) to fixture

SAFETY WARNING: READ WIRING AND GROUNDING INSTRUCTIONS (I.S. 18) AND ANY ADDITIONAL DIRECTIONS. TURN THE POWER SUPPLY DURING INSTALLATION. IF NEW WIRING IS REQUIRED, CONSULT A QUALIFIED ELECTRICIAN OR LOCAL AUTHORITIES FOR CODE REQUIREMENTS.

Wiring instructions

Indoor Fixtures

  1. Connect positive supply wire (A) (typically black or the smooth, unmarked side of the two-conductor cord) to positive fixture lead (B) with an appropriately sized twist on the connector – see Drawings 1 or 2.
  2. Connect negative supply wire (C) (typically white or the ribbed, marked side of the two-conductor cord) to negative fixture lead (D).
  3. Please refer to the grounding instructions below to complete all electrical connections

Outdoor Fixtures

  1. Connect positive supply wire (A) (typically black or the smooth unmarked side of the two-conductor cord) to positive fixture lead (B) with an appropriately sized twist on connector — see Drawings 2 or 3.
  2. Connect negative supply wire (C) (typically white or the ribbed, marked side of the two-conductor cord) to negative fixture lead (D).
  3. Cover the open end of connectors with silicone sealant to form a watertight seal. If installing a wall mount fixture, use caulk to seal gaps between the fixture mounting plate (backplate) and the wall. This will help prevent water from entering the outlet box. If the wall surface is lap siding, use caulk and a fixture mounting platform specially.
  4. Please refer to the grounding instructions below to complete all electrical connections.

Drawing 1 – Flush Mount

Drawing 2 – Chain Hung

Grounding Instructions

  • Flush Mount Fixtures
    • For positive grounding in a 3-wire electrical system, fasten the fixture ground wire (E) (typically copper or green plastic coated) to the fixture mounting strap (M) with the ground screw (S) – see Drawing 1.
    • Note: On straps for screw-supported fixtures, first install the two mounting screws in the strap. Any remaining tapped hole may be used for the ground screw.
  • Chain Hung Fixtures
    • Loop fixture ground wire (E) (typically copper or green plastic coated) under the head of the ground screw (S) on the fixture mounting strap (M) and connect to the loose end of the fixture ground wire directly to the ground wire of the building system with appropriately sized twist-on connectors – see Drawing 2.
  • Post-Mount Fixtures
    • Connect fixture ground wire (E) (typically copper or green plastic coated) to the power supply ground with an appropriately sized twist-on connector inside the post. Cover the open end of the connector with silicone sealant to form a watertight seal – see Drawing 3.

Drawing 3 – Post-Mount

  • 33000 Pin Oak Parkway Avon Lake,
  • OH 44012 800.446.5539 /
  • 440.653.5500
  • hinkley.com.
  • Item No: 28814

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals